Skip to main content
International Journal of Molecular Sciences logoLink to International Journal of Molecular Sciences
. 2016 Feb 6;17(2):219. doi: 10.3390/ijms17020219

A Classic Near-Infrared Probe Indocyanine Green for Detecting Singlet Oxygen

Cheng-Yi Tang 1,2,, Feng-Yao Wu 1,, Min-Kai Yang 1, Yu-Min Guo 1, Gui-Hua Lu 1,2, Yong-Hua Yang 1,2,*
Editor: Michael R Hamblin
PMCID: PMC4783951  PMID: 26861313

Abstract

The revelation of mechanisms of photodynamic therapy (PDT) at the cellular level as well as singlet oxygen (1O2) as a second messengers requires the quantification of intracellular 1O2. To detect singlet oxygen, directly measuring the phosphorescence emitted from 1O2 at 1270 nm is simple but limited for the low quantum yield and intrinsic efficiency of 1O2 emission. Another method is chemically trapping 1O2 and measuring fluorescence, absorption and Electron Spin Resonance (ESR). In this paper, we used indocyanine green (ICG), the only near-infrared (NIR) probe approved by the Food and Drug Administration (FDA), to detect 1O2 in vitro. Once it reacts with 1O2, ICG is decomposed and its UV absorption at 780 nm decreases with the laser irradiation. Our data demonstrated that ICG could be more sensitive and accurate than Singlet Oxygen Sensor Green reagent® (SOSG, a commercialized fluorescence probe) in vitro, moreover, ICG functioned with Eosin Y while SOSG failed. Thus, ICG would reasonably provide the possibility to sense 1O2 in vitro, with high sensitivity, selectivity and suitability to most photosensitizers.

Keywords: singlet oxygen (1O2), indocyanine green (ICG)

1. Introduction

Singlet oxygen (1O2), a highly reactive oxygen species (ROS), plays a crucial role in photodynamic therapy (PDT) by causing oxidative damage to proteins, DNA and lipids [1,2,3]. In addition, 1O2 is proposed to be a second messenger in cell signaling transduction [4]. Nevertheless, the detailed molecular mechanisms of PDT at the cellular level as well as 1O2 as a second messenger are not fully understood yet, partly due to limitations of quantification of intracellular 1O2 such as short half-life and high reactivity. Therefore, development of high sensitivity methods for detecting 1O2 in vivo is an appealing challenge [5,6,7,8].

Directly measuring the light emission at ca. 1270 nm of 1O2 is frequently used for 1O2 detection and characterization, but this method is limited for the low quantum yield (ca. 10−7) [9] and the intrinsic low efficiency of singlet-oxygen emission, especially in physiological environments where the lifetime of 1O2 is fairly short (3.1 μs) [10]. Chemical trapping of 1O2 is also applied extensively, and the detecting methods include fluorescence, absorption and Electron Spin Resonance (ESR). Fluorescence probes for 1O2 have drawn much attention, including DPAX or DMAX [11], ATTA-Eu3+ [12] and Singlet Oxygen Sensor Green reagent® (SOSG). They use an anthracene moiety to trap 1O2 that quenches the fluorescence of the fluorophore through an electron transfer reaction. Once it trapps 1O2, the resultant oxygen adduct fails to be a functional intramolecular electron donor, and the fluorescence is recovered. For example, SOSG emits nattier blue fluorescence at 395 and 416 nm, under excitation at 372 and 393 nm. Upon reaction with 1O2, the immediate product SOSG endoperoxide (SOSG-EP) exhibits green fluorescence, with excitation and emission peak at 504 and 525 nm, respectively [13]. These probes are convenient, highly sensitive and widely used, especially SOSG, which has been broadly used in recent studies [14,15,16,17]. However, fluorescence probes have several drawbacks. One is the lack of specificity when used with some photosensitizers. Many 1O2 sensitizers have a pronounced absorption band in the visible spectrum. If there is overlap with the emission peak of fluorophores of the probe, the signal produced by reaction with 1O2 will be diminished or even eliminated. False-negative signals arise in these situations to camouflage the signal enhancement evoked by 1O2. For instance, xanthene dyes such as rose bengal and eosin Y exhibit intense absorption bands in 525 nm, which happens to be the emission peak wavelength of SOSG-EP [18]. In this paper, we clarified the interference of eosin Y on SOSG to detect 1O2. Moreover, compared with ESR and absorption measurement, fluorescence signals are more unstable and temporal to detect.

In consideration of remedying these defects, we focused on developing new 1O2 probes. Serendipitously, we discovered for the first time that UV absorption of indocyanine green (ICG) at 780 nm decreased under 660 nm laser irradiation in chlorin e6 (Ce6) solution. As another tricarbocyanine, ICG is the only near-infrared (NIR) probe approved by the Food and Drug Administration (FDA) and has been used in clinical therapy for over 30 years with a high safety record [19]. ICG is a negatively charged and amphiphilic tricarbocyanine, with an absorption peak at ~807  nm and an emission peak at ~822  nm [20]. In this paper, we conducted systematic experiments to substantiate that ICG can function as an 1O2 probe. Once irradiated under 660 nm laser light, Ce6 can produce 1O2, which decomposes ICG through the break of alkene (double bond in a polymethine chain) hypothetically (Supplementary Material, Figure S1) [21]. This probe is safe, sensitive and broadly suited for most photosensitizers. To better evaluate its detecting ability, we chose the commercialized 1O2 probe SOSG as a reference probe.

2. Results and Discussion

The feasibility of ICG to detect 1O2 produced by Ce6 was assessed (Figure 1). The intensity of maximum absorption (at 780 nm) of ICG solution (25 μg/mL) slightly decreased after each laser irradiation (Figure 1a). This indicated that ICG was sufficiently stable under 660 nm laser irradiation in the medium. In contrast, absorption of Ce6 (5 μg/mL) at 400 and 650 nm significantly reduced under laser irradiation as expected (Figure 1b). This indicated that Ce6 completely decomposed after 15 min laser irradiation. The UV absorption spectra of mixed solution of ICG and Ce6 was also examined with and without laser irradiation, respectively (Figure 1c,d). Ce6 had no influence on absorption of ICG at 780 nm (Figure 1c). The solution was exposed to laser irradiation, then the absorption of ICG at 780 nm significantly reduced after each instance of laser irradiation (Figure 1d). The decrease of UV absorption was accordant with the visible bleaching of the green color of ICG as the picture denoted (Figure 1d), which was attributed to the decomposition of ICG by 1O2 generated by Ce6. The absorption decline of ICG was correlated positively with the time of laser irradiation, which can be explained by the increment of amount produced by Ce6 under continuous laser irradiation [22]. Therefore, we proposed that it was feasible to use ICG as a singlet oxygen probe.

Figure 1.

Figure 1

Feasibility of ICG to detect 1O2. (a) ICG under laser irradiation; (b) Ce6 under laser irradiation; (c) ICG, Ce6 and ICG with Ce6; (d) ICG with Ce6 under laser irradiation.

The sensitivity of ICG towards 1O2 was assessed by using ICG to detect different concentrations of 1O2 (Figure 2 and Table S1 (Supplementary Material)). The 1O2 concentration was proportional to Ce6 concentration and laser irradiation time [22]. Both of the decreases in UV absorption of ICG and increase in fluorescence intensity of SOSG displayed a concentration-dependent manner, which further confirmed that ICG could function as an 1O2 probe. There were significant differences of ICG absorption intensity between each adjacent Ce6 concentration group (p < 0.05); however, SOSG failed to distinguish high Ce6 concentration groups (2.5 and 5 μg/mL) (p > 0.05). Therefore, it was assumed that ICG was more accurate than SOSG.

Figure 2.

Figure 2

Sensitivity of ICG to 1O2 produced by Ce6. (a) UV absorbance of ICG with Ce6 after each 10-s laser irradiation (nine times in total); (b) fluorescence intensity of SOSG with Ce6 after each 10-s laser irradiation (nine times in total). (Mean ± SD, n = 3)

To verify the high accuracy of ICG for 1O2 detection, we used ICG and SOSG to detect 1O2 produced by Ce6 at both high and low concentration with consistent laser irradiation time (Figure 3 and Table S2 (Supplementary Material)). The decrease in absorbance of ICG was correlated positively with an increase of Ce6 concentration from 2 to 5 μg/mL, as demonstrated above, and the differences among the four groups were significant (p < 0.05) (Figure 3a). However, there were no significant differences between the SOSG fluorescence intensity of each adjacent concentration group after laser irradiation (Figure 3b). This result confirmed the higher detecting accuracy of ICG than SOSG. In addition, it indicated that ICG has a wider detection scope than SOSG, hence we compared the detecting performance of ICG with SOSG at very low 1O2 concentration (Figure 3c,d). The mixed solutions of ICG or SOSG with Ce6 at 0.31625 μg/mL were prepared, and all the samples were under 10-s laser irradiation. The results showed that the ICG absorption decreased significantly after laser irradiation (p < 0.05), but there was no significant increase of fluorescence intensity of SOSG. Our data denoted that ICG could detect a wider range of 1O2 concentration and perform more accurately than SOSG.

Figure 3.

Figure 3

Accuracy of ICG to detect 1O2. (a) UV absorbance of ICG with different Ce6 concentrations after 30 s laser irradiation (*, p < 0.05); (b) fluorescence intensity of SOSG with different Ce6 concentrations after 30 s laser irradiation; (c) absorbance of ICG with the lowest Ce6 concentration after 10 s laser irradiation (*, p < 0.05); (d) fluorescence intensity of SOSG with the lowest Ce6 concentration after 10 s of laser irradiation. (Mean ± SD, n = 3).

To demonstrate that ICG could detect a broader range of photosensitizers than SOSG, we chose Eosin Y as the photosensitizer and scanned the absorption and emission spectra of mixed solutions of Eosin Y with either ICG or SOSG, respectively (Figure S2, Supplementary Material). Eosin Y had no influence on absorption of ICG at 780 nm, like Ce6 did. In contrast, it exhibited a fluorescence emission peak at 525 nm, overlapped with the detection range of SOSG.

We compared the sensitivity of ICG and SOSG on 1O2 produced by Eosin Y. ICG was sufficiently stable under 532 nm laser irradiation (Figure S3a, Supplementary Material), and the absorption decrease of ICG at 780 nm with an increasing amount of 1O2 was significant (Figure S3b, Supplementary Material). The decrease in UV absorption displayed a concentration-dependent manner (Figure 4a). There were significant differences of ICG absorption intensity between each adjacent Eosin Y concentration group (p < 0.05). In contrast, SOSG failed to exhibit similar increments of fluorescence intensity under laser irradiation as SOSG and Ce6 mixture did (Figure 4b). This was tentatively explained by fluorescence resonance energy transfer (FRET), that is the energy emitted by SOSG-EP was absorbed by Eosin Y spontaneously, so the fluorescence measured is mostly from Eosin Y itself. One piece of evidence is the high molar extinction value of Eosin Y at 525 nm, the emission peak of SOSG (Figure S4, Supplementary Material). Moreover, the fluorescence intensity of SOSG before laser irradiation displayed an Eosin Y concentration-dependent manner. Considering the emission peak of Eosin Y at 525 nm, this fluorescence increment could be explained by the concentration-dependent increase of its emission at 525 nm (Figure S2, Supplementary Material). Another corroborative piece of evidence was the fluorescence intensity variation of Eosin Y upon 532 nm laser irradiation, which exhibited similar tendency and value to that of mixtures with SOSG (Figure S5, Supplementary Material). Finally, considering the intracellular environment is complicated and other reactive species like reactive oxygen species (ROS) and biological antioxidants like ascorbic acid (Vc) may influence the function of ICG, we examined its selectivity (Figure S6, Supplementary Material). Results showed that neither Vc nor H2O2 had a significant effect on the absorbance of ICG in the absence of 1O2, therefore, ICG possessed a high sensitivity towards 1O2.

Figure 4.

Figure 4

Comparison of sensitivity of ICG and SOSG on 1O2 produced by Eosin Y. (a) UV absorbance of ICG with Eosin Y after each 30-s 532 nm laser irradiation (six times in total); (b) fluorescence intensity of SOSG with Eosin Y after each 30-s laser irradiation (six times in total). (Mean ± SD, n = 3).

3. Materials and Methods

3.1. Materials

UV absorption spectra of ICG were measured with UV spectrophotometer (Shimadzu, UV-2450, Kyoto, Japan). The UV absorption of ICG (at 780 nm) and the fluorescence of SOSG (λexem = 504/525 nm) were measured by a microplate reader. Laser irradiation was performed by two laser devices (660 nm, 1 w/cm2 and 532 nm, 0.1 w/cm2). Ce6, ICG and Eosin Y were purchased from Sigma-Aldrich Co. LLC (Shanghai, China). SOSG was purchased from Life Technologies (Shanghai, China).

3.2. Feasibility of ICG to Detect 1O2

Samples of ICG (25 μg/mL), Ce6 (6 μg/mL) and their mixture were prepared. The solvent is water. Absorption of each sample was measured with or without 660 nm laser irradiation. Laser irradiation was performed five times in total and 3 min each time.

3.3. Sensitivity of ICG to Detect 1O2

The mixed solutions of ICG (25 μg/mL) or SOSG (6 μg/mL) with different concentrations of Ce6 (0.3125, 0.625, 1.25, 2.5 and 5 μg/mL) were prepared and exposed under ten times of 660 nm laser irradiation (10 s each time). The UV absorption of ICG (at 780 nm) and the fluorescence of SOSG (λexem = 504/525 nm) were measured after each irradiation by a microplate Reader.

3.4. Accuracy of ICG to Detect 1O2

The mixed solutions of ICG (25 μg/mL) or SOSG (6 μg/mL) with four Ce6 concentrations (2, 3, 4 and 5 μg/mL) were prepared. Afterwards, the absorbance of ICG (at 780 nm) and fluorescence intensity of SOSG (λexem = 504/525 nm) were measured before and after 30-s 660 nm laser irradiation, respectively. The mixed solutions of ICG or SOSG with Ce6 (0.31625 μg/mL) were prepared, and all samples were under 10-s 660 nm laser irradiation before the absorbance of ICG (at 780 nm) and fluorescence intensity of SOSG (λexem = 504/525 nm) were measured.

3.5. Comparison of Sensitivity of ICG and SOSG on 1O2 Produced by Eosin Y

The water solutions of ICG (25 μg/mL) or SOSG (6 μg/mL) with five concentrations of Eosin Y (0.31255, 0.625, 1.25, 2.5 and 5 μg/mL) were prepared and exposed under six times of 532 nm laser irradiation (30 s each time). The UV absorption of ICG (at 780 nm) and the fluorescence of SOSG (λexem = 504/525 nm) were measured after each irradiation by a microplate reader.

3.6. Disturbance of Eosin Y on Absorption Spectrum of ICG

Samples of ICG (25 μg/mL), Eosin Y (2.5 μg/mL) and their mixture were prepared. UV absorption spectra of each sample were scanned. Similarly, samples of SOSG (6 μg/mL), Eosin Y (2.5 μg/mL) and their mixture were prepared. Fluorescence spectrum was scanned (λexem = 504/525 nm).

3.7. Feasibility of ICG to Detect 1O2 Produced by Eosin Y

Samples of ICG (25 μg/mL), Eosin Y (2.5 μg/mL) and their mixture were prepared. The solvent is water. Absorption of each sample was measured with or without 532 nm laser irradiation, respectively. Laser irradiation was performed five times in total and 3 min each time.

3.8. Tentative Explanation of Eosin Y Interference

Different concentrations of Eosin Y water solution (0.3125, 0.625, 1.25, 2.5 and 5 μg/mL) were prepared and exposed under six times of 532 nm laser irradiation (30 s each time). The fluorescence of Eosin Y (λexem = 504/525 nm) was measured after each irradiation.

3.9. The Selectivity of ICG

The mixed solutions of SOSG (6 μg/mL) and VitC (4.4 μg/mL) or H2O2 (3.4 μg/mL) with and without Ce6 (2.5 μg/mL) were prepared. The same set of solutions in which SOSG was substituted with ICG (20 μg/mL) were prepared. All of the mixed solutions without Ce6 were placed at 25 °C for 10 min before the absorbance of ICG was examined. Similarly, mixed solutions with Ce6 were irradiated by laser light for 90 s to produce 1O2 before the SOSG fluorescence and ICG absorption were measured.

4. Conclusions

To detect 1O2, directly measuring the phosphorescence emitted from 1O2 at 1270 nm is simple but limited for the low quantum yield and intrinsic efficiency of 1O2 emission. SOSG, a commercialized fluorescence probe, is widely used but unsuitable for photosensitizers whose absorption bands overlap the emission band of SOSG endoperoxide. In our paper, the results show that ICG, an NIR probe approved by the FDA, could be more sensitive and accurate than SOSG for 1O2 detection in vitro. In addition, ICG is water soluble, non-toxic and suitable for most photosensitizers. Therefore, ICG would have application prospects in detecting 1O2 in vitro.

Acknowledgments

This work was financially supported by the Program for Changjiang Scholars and Innovative Research Team in University (IRT_14R27) and the National Natural Science Foundation of China (NSFC).

Supplementary Materials

Supplementary materials can be found at http://www.mdpi.com/1422-0067/17/2/219/s1.

Author Contributions

Cheng-Yi Tang, Feng-Yao Wu and Yong-Hua Yang contributed to the experiment design and management. Cheng-Yi Tang, Feng-Yao Wu and Min-Kai Yang performed the experiments. Cheng-Yi Tang, Yu-Min Guo and Gui-Hua Lu participated in the data analyses. Cheng-Yi Tang wrote the manuscript. All authors carefully checked and approved the manuscript.

Conflicts of Interest

The authors declare no conflict of interest.

References

  • 1.Weishaupt K.R., Gomer C.J., Dougherty T.J. Identification of singlet oxygen as the cytotoxic agent in photoinactivation of a murine tumor. Cancer Res. 1976;36:2326–2329. [PubMed] [Google Scholar]
  • 2.Dolmans D.E.J.G.J., Dai F., Jain R.K. Timeline: Photodynamic therapy for cancer. Nat. Rev. Cancer. 2003;3:380–387. doi: 10.1038/nrc1071. [DOI] [PubMed] [Google Scholar]
  • 3.Henderson B.W., Waldow S.M., Mang T.S., Potter W.R., Malone P.B., Dougherty T.J. Tumor destruction and kinetics of tumor cell death in two experimental mouse tumors following photodynamic therapy. Cancer Res. 1985;45:572–576. [PubMed] [Google Scholar]
  • 4.Apel K., Hirt H. Reactive oxygen species: Metabolism, oxidative stress, and signal transduction. Annu. Rev. Plant Biol. 2004;55:373–399. doi: 10.1146/annurev.arplant.55.031903.141701. [DOI] [PubMed] [Google Scholar]
  • 5.Chengzhou Z., Guohai Y., He L., Dan D., Yuehe L. Electrochemical sensors and biosensors based on nanomaterials and nanostructures. Anal. Chem. 2015;87:230–249. doi: 10.1021/ac5039863. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Ariga K., Yamauchi Y., Ji Q., Yonamine Y., Hill J.P. Research update: Mesoporous sensor nanoarchitectonics. APL Mater. 2014;2:219. doi: 10.1063/1.4868177. [DOI] [Google Scholar]
  • 7.Ming L., Cushing S.K., Nianqiang W. Plasmon-enhanced optical sensors: A review. Analyst. 2014;140:386–406. doi: 10.1039/c4an01079e. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Shinsuke I., Jan L., Wim V.R., Daisuke I., Kosuke M., Hill J.P., Ariga K. Porphyrin-based sensor nanoarchitectonics in diverse physical detection modes. Phys. Chem. Chem. Phys. 2014;16:9713. doi: 10.1039/c3cp55431g. [DOI] [PubMed] [Google Scholar]
  • 9.Claude S., Reinhard S. Physical mechanisms of generation and deactivation of singlet oxygen. Chem. Rev. 2003;103:1685–1757. doi: 10.1021/cr010371d. [DOI] [PubMed] [Google Scholar]
  • 10.Ogilby P.R. Singlet oxygen: There is indeed something new under the sun. Chem. Soc. Rev. 2010;39:3181–3209. doi: 10.1039/b926014p. [DOI] [PubMed] [Google Scholar]
  • 11.Umezawa N., Tanaka K., Urano Y., Kikuchi K., Higuchi T., Nagano T. Novel fluorescent probes for singlet oxygen. Angew. Chem. Int. Ed. 1999;38:2899–2901. doi: 10.1002/(SICI)1521-3773(19991004)38:19&#x0003c;2899::AID-ANIE2899&#x0003e;3.0.CO;2-M. [DOI] [PubMed] [Google Scholar]
  • 12.Song B., Wang G., Yuan J. A new europium chelate-based phosphorescence probe specific for singlet oxygen. Chem. Commun. 2005;28:3553–3555. doi: 10.1039/b503980k. [DOI] [PubMed] [Google Scholar]
  • 13.Ragàs X., Jiménez-Banzo A., Sánchez-García D., Batllori X., Nonell S. Singlet oxygen photosensitisation by the fluorescent probe singlet oxygen sensor green. Chem. Commun. 2009;20:2920–2922. doi: 10.1039/b822776d. [DOI] [PubMed] [Google Scholar]
  • 14.Flors C., Fryer M.J., Waring J., Reeder B., Bechtold U., Mullineaux P.M., Nonell S., Wilson M.T., Baker N.R. Imaging the production of singlet oxygen in vivo using a new fluorescent sensor, singlet oxygen sensor greenr. J. Exp. Bot. 2006;57:1725–1734. doi: 10.1093/jxb/erj181. [DOI] [PubMed] [Google Scholar]
  • 15.Price M., Reiners J.J., Santiago A.M., Kessel D. Monitoring singlet oxygen and hydroxyl radical formation with fluorescent probes during photodynamic therapy. Photochem. Photobiol. 2009;85:1177–1181. doi: 10.1111/j.1751-1097.2009.00555.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Luo Q., Gu Y., Li X. Optics in health care and biomedical optics IV; Proceedings of the SPIE—The International Society for Optical Engineering; Beijing, China. 12–20 October 2010; [Google Scholar]
  • 17.De Melo L.S., Gomes A.S., Saska S., Nigoghossian K., Messaddeq Y., Ribeiro S.J., de Araujo R.E. Singlet oxygen generation enhanced by silver-pectin nanoparticles. J. Fluoresc. 2012;22:1633–1638. doi: 10.1007/s10895-012-1107-4. [DOI] [PubMed] [Google Scholar]
  • 18.Derosa M.C., Crutchley R.J. Photosensitized singlet oxygen and its applications. Coord. Chem. Rev. 2002;s233–s234:351–371. doi: 10.1016/S0010-8545(02)00034-6. [DOI] [Google Scholar]
  • 19.Ogawa M., Kosaka N., Choyke P.L., Kobayashi H. In vivo molecular imaging of cancer with a quenching near-infrared fluorescent probe using conjugates of monoclonal antibodies and indocyanine green. Cancer Res. 2009;69:1268–1272. doi: 10.1158/0008-5472.CAN-08-3116. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Schaafsma B.E., Mieog J.S., Merlijn H., van der Velde J.R., Kuppen P.J., Löwik C.W., Frangioni J.V., van de Velde C.J., Vahrmeijer A.L. The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery. J. Surg. Oncol. 2011;104:323–332. doi: 10.1002/jso.21943. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Engel E., Schraml R., Maisch T., Kobuch K., König B., Szeimies R.M., Hillenkamp J., Bäumler W., Vasold R. Light-induced decomposition of indocyanine green. Investig. Ophthalmol. Vis. Sci. 2008;49:1777–1783. doi: 10.1167/iovs.07-0911. [DOI] [PubMed] [Google Scholar]
  • 22.Weissleder R. Clearer vision for in vivo imaging. Nat. Biotechnol. 2001;19:316–317. doi: 10.1038/86684. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials


Articles from International Journal of Molecular Sciences are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES