Skip to main content
Journal of Clinical Sleep Medicine : JCSM : Official Publication of the American Academy of Sleep Medicine logoLink to Journal of Clinical Sleep Medicine : JCSM : Official Publication of the American Academy of Sleep Medicine
. 2016 Apr 15;12(4):555–564. doi: 10.5664/jcsm.5690

Obstructive Sleep Apnea Syndrome in Company Workers: Development of a Two-Step Screening Strategy with a New Questionnaire

Michiel M Eijsvogel 1,, Sytske Wiegersma 2, Winfried Randerath 3, Johan Verbraecken 4, Esther Wegter-Hilbers 5, Job van der Palen 6
PMCID: PMC4795283  PMID: 26518703

Abstract

Study Objectives:

To develop and evaluate a screening questionnaire and a two-step screening strategy for obstructive sleep apnea syndrome (OSAS) in healthy workers.

Methods:

This is a cross-sectional study of 1,861 employees comprising healthy blue- and white-collar workers in two representative plants in the Netherlands from a worldwide consumer electronic company who were approached to participate. Employees were invited to complete various sleep questionnaires, and undergo separate single nasal flow recording and home polysomnography on two separate nights.

Results:

Of the 1,861 employees, 249 provided informed consent and all nasal flow and polysomnography data were available from 176 (70.7%). OSAS was diagnosed in 65 (36.9%). A combination of age, absence of insomnia, witnessed breathing stops, and three-way scoring of the Berlin and STOPBANG questionnaires best predicted OSAS. Factor analysis identified a six-factor structure of the resulting new questionnaire: snoring, snoring severity, tiredness, witnessed apneas, sleep quality, and daytime well-being. Subsequently, some questions were removed, and the remaining questions were used to construct a new questionnaire. A scoring algorithm, computing individual probabilities of OSAS as high, intermediate, or low risk, was developed. Subsequently, the intermediate risk group was split into low and high probability for OSAS, based on nasal flow recording. This two-step approach showed a sensitivity of 63.1%, and a specificity of 90.1%. Specificity is important for low prevalence populations.

Conclusion:

A two-step screening strategy with a new questionnaire and subsequent nasal flow recording is a promising way to screen for OSAS in a healthy worker population.

Clinical Trial Registration:

Development and validation of a screening instrument for obstructive sleep apnea syndrome in healthy workers. Netherlands Trial Register (www.trailregister.nl), number: NTR2675.

Citation:

Eijsvogel MM, Wiegersma S, Randerath W, Verbraecken J, Wegter-Hilbers E, van der Palen J. Obstructive sleep apnea syndrome in company workers: development of a two-step screening strategy with a new questionnaire. J Clin Sleep Med 2016;12(4):555–564.

Keywords: home recording, polysomnography, questionnaire, screening, sleep apnea syndrome

INTRODUCTION

Obstructive sleep apnea syndrome (OSAS) is a prevalent and treatable disease with often impaired daytime performance and increased cardiovascular and metabolic risks. Recently, increasing awareness for these consequences is reflected in a growing interest in screening for OSAS.13 Screening for OSAS can be important in a hospital setting (preoperative patients), primary care, work environment or in specific groups such as commercial drivers.2

BRIEF SUMMARY

Current Knowledge/Study Rationale: In community screening for obstructive sleep apnea syndrome (OSAS) a single or combination of easy to apply test(s) with a high specificity is needed to identify correctly the large numbers of subjects without OSAS and keep the false positive rate as low as possible to avoid unnecessary costly further investigations. A pilot study was performed to develop such a tool with the intention to screen more than 10.000 employees as convincing studies for this type of screening are lacking.

Study Impact: We demonstrated that a combined questionnaire with three outcomes (OSAS unlikely, possible, likely) and applying nasal flow only for the intermediate outcome could make such a screening feasible.

In the hospital setting, the pretest prevalence for any disease is higher than in primary care and the primary goal of hospital-based screening is mostly to “rule in” the disease.4 In community screening for diseases with relative low prevalence and no fatal outcome, the goal is to “rule out” disease. The large group of subjects with no disease should be correctly identified and in subjects with positive test results, the false positive rate should be as low as possible to avoid unnecessary costly further investigations (like polysomnography [PSG]). This can be achieved by a test with a high specificity, mostly at the expense of reduced sensitivity, so accepting some missed cases. In addition, a confirmation test (in OSAS a sleep study) in subjects with positive test results should be performed. The argument to do community screening is as follows: it is better to screen realistically and diagnose at least a relevant proportion of patients out of a large group of healthy people than not to screen at all. In our study, we focused on this community type of screening.

Screening can be costly, especially in the case of low prevalence rates, and only low-burden methods will result in a sufficient response rate.2,5 In a systematic review on screening questionnaires for OSAS, only 20 of 4,105 studies were considered valid for inclusion, due to different study population (sleep clinic or hospital), methodological aspects (no PSG as gold standard, no clearly defined apnea hypopnea index (AHI), and insufficient data to draw a 2 × 2 table).5 Finally, only 10 of these studies were analyzed. From these only three studies were done in the general population using two different questionnaires.5 The most used questionnaire in the general population and in primary care is the Berlin questionnaire (BerlinQ) with five PSG validated studies published.

Using an AHI ≥ 5 as a definition for OSAS, sensitivity varies between 36% and 86%, whereas the specificity varies between 70–84%.69 In a meta-analysis looking at studies on screening for OSAS in a preoperative setting, improved accuracy was noted when questionnaires, body measurements, morphometric data, and oximetry were combined.10 Most questionnaires result in a dichotomous answer: high or low probability for OSAS; questionnaires with three possible outcomes (high – intermediate – low probability) allow application of an extra test for the intermediate result. In such a so-called two-step strategy, Gurubhagavatula et al.11 performed additional oximetry in the intermediate group among commercial drivers, resulting in a sensitivity of 74% and high specificity of 89%.

As part of their social responsibility, Philips NV Netherlands planned to screen their workers in The Netherlands (13,500) for OSAS. Given the large numbers, the paucity of literature in occupational population-based screening, and the financial consequences, a screening strategy was developed, using a combination of existing questionnaires. In order to validate this strategy, factor analysis was performed, together with PSG as the gold standard, in a sample of employees. In advance, it was decided to develop a two-step strategy including nasal flow (NFlow) recording.

METHODS

Study Design

After obtaining informed consent, a set of diagnostic questionnaires were completed by all participants, whereas NFlow recording and home-based PSG (as gold standard) were performed in all employees as well, without knowledge of the outcome of the applied questionnaires and recordings. The Medical Ethical Committee Twente at Enschede, The Netherlands, approved this study, which is registered at Netherlands Trial Register (www.trailregister.nl) number NTR2675.

Study Population and Sample Size

A total of 1,861 employees comprising healthy blue- and white-collar workers in two representative plants from Philips were approached through the regular Philips communication channels (newsletter, Email, website). Subsequently, workers received a letter at home explaining the aim of the study (to find a proper screening tool for OSAS, which is prevalent and often under diagnosed), the study outline (online questionnaires and two separate nights of sleep recording at home), and the possible benefit (stating that for most employees the investigation will not have any advantages, because only a minority will have OSAS). A reminder was sent out 1 week later. After returning the informed consent form by post, these employees received a personal username and password and were invited to fill in the online questionnaires.

Questionnaires

All questionnaires were translated into Dutch by the Philips Translation Services, with forward and backward translation by two different translators, and were administered as a computer-based questionnaire. Factor analysis was performed for the BerlinQ, STOP Questionnaire (STOPQ) and Athens Insomnia Scale (AIS) separately, to assess their validity in the Dutch language, and will be reported elsewhere.

The Berlin questionnaire (BerlinQ) has 11 dichotomous and polytomous items on snoring, wake time, sleepiness, blood pressure, and obesity, and is organized in three different categories. Subjects scoring positive on two or more of these categories are considered at high risk and subjects who score positive on none or only on one of these categories are considered at low risk for OSAS. The first category is positive when two or more positive responses are obtained on items 1–5, the second category is positive when two or more positive responses are given on items 6–8, and the third category is positive with at least one positive response on items 10–11 is obtained.6

The STOPBANG questionnaire (STOPBANGQ) has eight dichotomous items, which can be divided into two parts.12 The first part or STOP questionnaire consists of four items: snoring, tiredness, observed apneas, and blood pressure. The second part (BANG) consists of also four items: body mass index (BMI), age, neck circumference, and sex. Subjects are considered at high risk when three or more of the eight items are scored positive and at low risk for OSAS with a score of less than three positive items.

The Athens Insomnia Scale (AIS) can be used to assess insomnia and can be useful to distinguish between different causes of sleepiness.14 It consists of eight questions. The questions can be scored using a four-point scale, ranging from 0 (“no problem at all”) to 3 (“very serious problem”). The total score of the AIS-8 ranges from 0 to 24. Subjects with a score of 6 or higher are considered to be at high risk of having insomnia. We used the very high cutoff score of 10 to exclude severe insomnia from our study population (see definition of OSAS). For an estimated prevalence of 10%, the negative predictive value (NPV) for this score is 94%.14,15

The Epworth Sleepiness Scale (ESS) is an 8-point self-completed questionnaire to assess the tendency to fall asleep in eight different daytimes conditions, with a score of 0–3 per item and a total scoring range of 0–24, with a cutoff value of ≥ 10.16

The Pittsburgh Sleep Quality Index is a self-rated questionnaire that assesses sleep quality over the past month, and can distinguish between good and poor sleepers.17 Nineteen questions generate five subgroups of information: sleep quality, sleep latency, sleep duration, sleep efficiency, and sleep disturbances and two additional subgroups consisting of use of sleep medication and daytime functioning. These seven groups are each scored by severity (0–3), leading to a total score range of 0–21. The normal cutoff value is > 5.

Nasal Flow Recording

All participating employees were asked to undergo 1 night of home NFlow recording (RU-Sleeping; Philips Respironics, Murrysville, PA, USA).3,18 NFlow is measured by pressure transduction with a nasal cannula connected to a small recording unit. Respiratory events are scored by the device when the peak-to-peak nasal pressure waveform initially fall at least below 50% of the baseline value and remained below at least 75% of the baseline value for a minimum of 10 sec. If a given hour had three “not valid” periods (at least 12 min without valid airflow), then that hour of the recording was discarded, marked as “ERR” and did not count toward the respiratory event index. At the end of the workday, the portable device with nasal cannula was provided with verbal and written instruction. The next morning, the device was collected at the workplace and read out. For a valid recording, a minimum of 4 h recording without “error” reading was needed.

Polysomnography

Home PSG was performed with the Alice PDx (Philips Respironics) and further analyzed with Polysmith (Neurotronics, Gainesville, FL) software. At the end of the workday, trained nurses supervised by a registered polysomnographic technologist applied the PSG electrodes and sensors. Electroencephalography was carried out with F4-M1, C4-M1, and O2-M1 derivations, together with nasal airflow (cannula), thoracic and abdominal movements (based on respiratory induction plethysmography, chin electromyography, vertical and horizontal eye movements, heart rate, and finger oximetry were measured as well. Sensor choice, settings and scoring were performed according to the American Academy of Sleep Medicine (AASM) 2007 rules.19 The alternative hypopnea definition (≥ 50% NFlow amplitude drop with ≥ 3% O2 desaturation or arousal) was applied. Registered polysomnographic technologists from the Nederlands Slaap Instituut (http://nederlandsslaapinstituut.nl) performed the home PSG, and analyzed the data.

OSAS Definition

The applied definition of OSAS was based on AHI, symptoms, and the absence of severe insomnia (AIS > 10). An AHI ≥ 15 was defined as OSAS and an AHI of 5–14 was only defined as OSAS, if severe insomnia was absent and symptoms (daytime sleepiness or at least two minor symptoms) were present as described in the AASM and the Dutch OSAS guideline.20,21 Information about symptoms was obtained from the questionnaires (Table 1).

Table 1.

Obstructive sleep apnea syndrome symptoms and related questions in questionnaires.

graphic file with name jcsm.12.4.555.t01.jpg

Additional Measurements

Medical history (concerning previously diagnosed OSAS, cardiovascular disease, hypertension), and anthropometric measurements such as neck circumference, blood pressure, body weight and height, and age were obtained during a 20-min one-to-one consultation by occupational nurses from the health advisory company, HumanCapitalCare (Eindhoven, The Netherlands). No specific resting time protocol was used for blood pressure measurement.

Statistical Analysis

Development of Questionnaire and Two-Step Screening Strategy

Based on factor analyzes and multivariate logistic regression a set of questions was selected that best predicted the presence or absence of OSAS in a healthy workers population. Many of these questions were derived from the BerlinQ and the STOPBANGQ. In contrast to routine two-way outcome scoring, these questionnaires were also scored leading to a three-way outcome: high, intermediate, and low risk for OSAS. For the BerlinQ categories and STOPBANGQ items the following scoring was used respectively for low, intermediate, and high risk: 0, 1–2, 3 categories and one or less, two to four, and five or more positive answers.

The questions selected formed the so-called Philips questionnaire (PhilipsQ). By multivariate logistic regression analysis, a scoring algorithm was constructed to compute individual probabilities of OSAS. These probabilities were divided into a high, intermediate, and low risk for OSAS. For employees ending up in the intermediate risk category according to this PhilipsQ, results from the NFlow measurement with a cut off NFlow value of 15 events/h were used to finally classify these employees into either high or low risk for OSAS.

Factor Analysis

Factor analysis was based on item response theory (IRT) instead of Classical Test Theory (CTT), which has several advantages over CTT.22,23 IRT enables to conduct factor analysis on variables that are not continuous, an aspect often ignored when factor analysis is applied.13,2426 Furthermore, IRT can deal with missing data and scales that contain items with different response formats, which is an important advantage, because the PhilipsQ contains both dichotomous and polytomous items and consists of several introductory and follow-up items that result in many missing data.22,23,27 Finally, IRT offers detailed insight in the psychometric characteristics.27

Factor analysis was performed in two steps; first, the factor structures of the three questionnaires used in the PhilipsQ (the BerlinQ, STOPQ, and AIS) were analyzed. Second, factor analysis was performed on the PhilipsQ to assess if the observed responses could be explained by an underlying structure and to assess the psychometric properties of the items.

The exploratory factor analysis was conducted with oblique cf-parsimax rotation, which minimizes variable and factor complexity and results in a simple, easily interpretable factor structure, using Mplus software (version 5.2, 2007, Muthén & Muthen, Los Angeles, CA, USA).28 For the BerlinQ, the AIS, and the PhilipsQ, Samejima's graded response model for ordered categorical (ordinal) variables was fitted.29 For the STOPQ, a two-parameter logistic model for binary variables was used. Item parameters were estimated using a mean-adjusted weighted least squares estimator.30 Based on the table of critical values of Stevens, factor loadings greater than 0.364 were considered significant.31 Model fit was assessed based on chi-square statistics, the root mean square error of approximation (RMSEA), the comparative fit index (CFI), and the Tucker Lewis index (TLI), using recommendations for adequate fit given by Hu and Bentler.32 Good model fit is considered as empirical evidence that an underlying structure is present, beneath the observed responses on the items.23

RESULTS

Baseline Data

Of the invited 1,861 employees 249 gave informed consent. Finally, 241 employees (12.9%) completed all questionnaires. Due to further refusal to participate or prior diagnosis of OSAS, 196 appointments for PSG and NFlow recording on 2 separate night were made; 196 home PSGs were performed, of whom 186 were valid (six battery failures in the first group of employees) and four PSGs showed incomplete data due to a memory bug. Of the 196 appointments for NFlow three employees did not show up. Eight employees had incomplete data (< 4 h), hence 185 flow-measurements were valid for analysis. In 176 employees, complete data from questionnaires, physical measurements, NFlow recordings, and PSGs were obtained for analysis (Figure 1).

Figure 1. Flow chart subjects: from invitation to performing two complete sleep recording nights.

Figure 1

Eighty-six employees (48.8%) did have an AHI ≥ 5, whereas 65 employees (36.9%) received a diagnosis of OSAS (Table 2). Significant differences between no OSAS and OSAS were found for age, BMI, neck circumference, AHI, oxygen de-saturation index, mean saturation of oxygen, arousal index, wake after sleep onset, sleep efficiency, non rapid eye movement (NREM)1, NREM3, rapid eye movement, NFlow index, STOPQ high risk and STOPBANGQ high risk. In employees with an AHI ≥ 5 or with OSAS, the STOPQ and the STOP-BANGQ, but not the BerlinQ was significantly more positive (high risk for OSAS) compared to employees with respectively an AHI < 5 or without OSAS (Table 2).

Table 2.

Morphometric, questionnaire, single nasal flow recording and polysomnography characteristics of all employees categorized by apnea-hypopnea index or obstructive sleep apnea syndrome.

graphic file with name jcsm.12.4.555.t02.jpg

Descriptive Statistics Questionnaire

Comparison of fit indices indicated that a seven-factor model had a significantly (p < 0.01) better fit than models with fewer factors: χ2 (98) = 114.62, CFI = 0.999, TLI = 0.998, RMSEA = 0.027. However, this model did not result in an interpretable factor solution. Therefore, the six-factor model, also demonstrating a good fit (χ2 (114) = 159.33, CFI = 0.998, TLI = 0.996, RMSEA = 0.041), was which resulted in a more interpretable solution. The factor solution for the PhilipsQ is shown in Table 3. Factor 1 contains only one item, which represents “snoring.” Factor 2 consists of four items and seems to represent “snoring severity.” Factor 3 represents “tiredness,” reflected by three items on tiredness and one item on daytime well-being. Factor 4, “observed apneas,” contains two items on observed apneas and one item with regard to the frequency of nodding off while driving. Five items reflect factor 5, “sleep quality.” Factor 6, “daytime well-being,” consists of six items with regard to tiredness and functioning during the daytime and an additional item on blood pressure. The item nodding off while driving did not load on any of the factors.

Table 3.

Factor loadings of Philips Questionnaire items.

graphic file with name jcsm.12.4.555.t03.jpg

Logistic Regression Analysis

Multivariate logistic regression analysis identified a number of variables as predictors for OSAS, shown in Table 4. As can be seen we used a novel, three-way scoring for the BerlinQ and STOPBANGQ as the normal two-way scoring (not shown) was less predictive than the three-way scoring.

Table 4.

Variables predicting obstructive sleep apnea syndrome.

graphic file with name jcsm.12.4.555.t04.jpg

A new questionnaire (PhilipsQ) was constructed from these best predictive questions and questionnaires (see supplemental material).

With the predictive factors, an algorithm can be written to compute the individual estimated probability (p) that a subject will have OSAS: p(OSAS) = 1 / (1+e-X), where X = −6.322 + 2.828 × AIS + 2.745 × STOPBANGQ High + 0.965 × STOP-BANGQ Intermediate + 4.640 × BerlinQ High + 1.584 × BerlinQ Intermediate + 0.790 × Age + 0.810 × BerlinQ Q-5. Exploratory logistic regression analyzes, testing different cutoff values of OSAS probabilities, led to the final cutoff values of 35% for low probability of OSAS and 55% for high probability of OSAS. In the second step, for employees with a probability between 35% and 55% the NFlow index with a cutoff of ≥ 15 breathing stops (> 10 sec) per hour was added to finally classify these employees into high or low risk as well. The decision to use these cutoff values was based on our preference to have primarily a high specificity for screening purposes; the test characteristics of the low, high, and intermediate + NFlow steps of the PhilipsQ and final two-step strategy is presented in Table 5. As can been seen, the sensitivity and specificity of the two-step strategy is 63.1% and 90.1% respectively. The area under the curve of the receiver operator characteristic curve is 0.81 (confidence interval 0.75–0.88).

Table 5.

Test characteristics Philips questionnaire and two-step strategy.

graphic file with name jcsm.12.4.555.t05.jpg

To translate these test characteristics into outcome in screening populations with different prevalences, the NPV and positive predictive values (PPV) were calculated (Table 6). To read this table, an example for 20% prevalence is given: in a screening population with an estimated prevalence of OSAS of 20%, 29.1% will need NFlow recording for the intermediate outcome of the PhilipsQ; finally, 20.5% will have a high probability for OSAS and will be referred to a sleep clinic, whereas OSAS will be confirmed in about two thirds (61.5%) of the referred persons. In those with a negative outcome of the two-step strategy, 90.7% should be correctly identified as negative for OSAS.

Table 6.

Outcome two-step screening strategy according to prevalence of obstructive sleep apnea syndrome.

graphic file with name jcsm.12.4.555.t06.jpg

A current practice is to use the BerlinQ or STOPBANGQ questionnaire, also in a low- prevalence setting as in community screening, and refer the cases with high-risk outcome for further testing. In this study we used these questionnaires as well. The sensitivity and specificity of the BerlinQ was 46.2% and 69.4% and for the STOPBANGQ 80.0% and 55.0%, respectively. The prevalence in our sample (due to self-selection) was high: 36.9%. However, for testing in a low prevalence setting in, for instance, 1,000 subjects and prevalence of 10%, the PPV is very low for both questionnaires (Berlin and STOP-BANG), due to many false positives compared to our two-step strategy (Table 7). A higher NPV and a small reduction in true positive rate (3.7%) for our two-step strategy, compared to 4.6% and 5.1% for the Berlin and STOPBANG questionnaire, respectively) was also observed. After completion of the screening all subjects with positive test results (true and false positives) should be referred for diagnostic sleep studies.

Table 7.

Estimated outcome of three screening strategies in 1,000 subjects and a 10% prevalence of OSAS.

graphic file with name jcsm.12.4.555.t07.jpg

DISCUSSION

Our study, investigating a two-step strategy to detect OSAS in a healthy workers population, demonstrated a sensitivity of 63.1%, and specificity of 90.1%. Most questionnaires used to screen for OSAS in low-prevalence groups use a high versus low risk outcome and have a limited sensitivity and specificity.69 It has been shown that the limited sensitivity and specificity can be improved with three-way scoring (high, low, intermediate risk of OSAS).11 This allows application of an extra test for subjects ending up in the intermediate risk group. The new PhilipsQ was constructed from the most predictive questions of a number of established OSAS and sleep questionnaires.

The high odds ratio of the AIS scoring is due to the used definition of OSAS, in which employees with an AIS score ≥ 10 were excluded as having OSAS. Only seven employees in the three-way scoring of the BerlinQ were at high risk (three positive categories), explaining the very high odds ratio of the variable “BerlinQ High vs. Low.” In the multivariate analysis, age was almost contributing statistically (0.052), and we decided to retain this variable in the overall formula to predict the individual probability of OSAS. The BerlinQ question five about breathing stops was not contributing statistically significantly, but left in the prediction as a separate variable because it was shown before as a predictive question in literature and guidelines.6,12

Factor analysis of the 21 questions in the PhilipsQ showed a six-factor structure as best interpretable, consisting of the following factors: snoring, snoring severity, tiredness, observed apneas, sleep quality, and daytime well-being. The question “nodding off while driving” (PhilipsQ question eight) did not load on any factor and therefore, it was not included in the final PhilipsQ. It was shown before that “nodding off while driving” is a conflicting question. Netzer et al.6 reported a reduction of the Cronbach α from 0.86 to 0.63 due to this question in category II of the BerlinQ. The related question “nodding off frequency” (PhilipsQ question nine) was therefore removed as well.

We constructed a scoring algorithm to compute individual probabilities of OSAS. These probabilities were divided into high, intermediate, and low risk. The intermediate group could be split into low and high probability for OSAS, based on NFLow with a cutoff of ≥ 15. This two-step strategy has a sensitivity of 63.1%, and specificity of 90.1%. Depending on the prevalence of OSAS in screening populations, a NPV of at least 90.7% for a prevalence ranging from 5% to 20% can be anticipated. For the much smaller group of subjects with a positive test, the PPV varies from 25% to 61%; these subjects with positive test results should than be referred for a diagnostic sleep study. The PhilipsQ is constructed of body measurements (BMI, age, neck circumference, sex) and questions from the BerlinQ, STOPQ, and AIS. These questionnaires are translated into many languages, which enables its implementation outside the Dutch language. Internal consistency for the different questionnaires used within the PhilipsQ has been published in the literature. For the BerlinQ, the Cronbach α for the category I questions (PhilipsQ questions 1–5) is 0.92, whereas it is 0.63 for category II questions (PhilipsQ questions 6–9) (or 0.86 when leaving out PhilipsQ questions 8).6 Leaving out question eight in the free available PhilipsQ was therefore done after this study. For the STOPQ (PhilipsQ questions 10–13) and AIS (PhilipsQ questions 14–21), Cronbach α is 0.92 and 0.89, respectively.12,14

In line with our study, Cowan et al.33 found no discriminating properties in the normal (two-way) scoring of the BerlinQ, in contrast to the STOPQ and STOPBANGQ. Several prediction models for OSAS, combining morphometric data, have been published in patients referred to a sleep clinic. The Multivariate Apnea Risk (MAP) and the Sleep Apnea Clinical Score (SACS) are such examples.34,35 Evaluating these and other models for OSAS (AHI ≥ 10) in referred patients showed a sensitivity range of 76% to 96% and a specificity range of 13% to 54%.38 These authors concluded that clinical prediction models are not sufficiently accurate to discriminate between patients with and without OSAS.36 Takegami et al.37 tested a four- variable prediction model (sex, blood pressure, BMI, snoring) for OSAS (AHI ≥ 15) in employees during a health check, and reported a sensitivity of 93% and a specificity of 66%.37 In this study, the study population was obscured with referred patients, and oximetry and type III portable monitoring was used instead of PSG. In a dataset from the Sleep Heart Health Study, Caffo et al.38 recently published (modern ensemble learning) algorithms for predicting OSAS with a RDI ≥ 7. They found BMI, age, snoring frequency, waist circumference, and snoring loudness as the variables with the largest impact on prediction performance.38 Except for waist circumference (not measured) the same variables in our predicting algorithm where included.

However, Caffo et al. did not investigate a two-step strategy, probably explaining the moderate specificity of 70%. However, Gurubhagavatula et al.11 applied such two-step screening strategy based on the multivariable apnea prediction index and oximetry in commercial drivers, which resulted in a sensitivity of 74% and a specificity of 89% for OSAS (AHI ≥ 5).11 These results were quite similar to our data. This somewhat higher sensitivity could be explained by using an AHI > 5 instead of our OSAS definition or as the authors stated, possibly due to regression toward the mean (due to strategy validation in the same development cohort). In a primary care setting, Chai-Coetzer et al.39 developed a two-step strategy to select OSAS, with a four-item questionnaire (waist circumference, breathing stops (BerlinQ, Q-5), snoring, and age) combined with oximetry to select severe OSAS (AHI ≥ 30). They reported a sensitivity of 88% and specificity of 82% in the validation group. Their OSAS50 screening questionnaire had a two-way result with a scoring range of 0–10 instead of an algorithm.39

A limitation of our study was that only 12.9% of the invited employees gave informed consent. However, a low participation rate and self-selection are inherent to community- based studies in healthy employees, especially when there is a substantial study burden to the participants (five questionnaires and 2 nights of sleep monitoring). Employees with sleep related complaints were probably more willing to participate, explaining the extremely high prevalence of OSAS (36.9%). On the upside, this self-selection resulted in a sufficient number of employees with OSAS that allowed a reasonable assessment of sensitivity and specificity of our two-step strategy. Our study is not unique in this respect, as another study in commercial drivers reported the same limitations; complete datasets (questionnaires, PSG, and oximetry data) were obtained in 9.4% with an observed prevalence for OSAS of 28%.11

Another limitation, and also related to self-selection is that NPV and PPV could not be determined accurately in a healthy workers population, because these parameters depend on the true prevalence of OSAS in the population studied. Therefore, we estimated NPV and PPV for several hypothetical prevalences. Finally, another drawback is the lack of a validation group. Instead of splitting our group, we decided to use all the employees for the estimation sample to obtain the best predictive statistics. A new validation study will be set up in the future.

One could argue about excluding severe insomnia in our definition of OSAS. Nevertheless, insomnia is one of the major sleep disorders with daytime symptoms that can result in false-positive test results in OSAS questionnaires, especially in the presence of benign snoring, which occurs in 30% to 50% of the adult population.6 However, coexistence of OSAS and insomnia and its possible interaction is a subject of recent interest.40,41 However, for screening for OSAS in a large population, we preferred to avoid this group of persons with overt insomnia, especially in mild OSAS. For this purpose, we used the AIS, which has a simple scale constructed just as the ESS. Instead of the widely used cutoff value of 6, we used the cutoff value of 10, with a NPV and PPV of 94% and 88%, respectively.15 This resulted in 13 of 176 employees with overt insomnia according to the AIS (mean score 12.6 ± 1). Four employees with insomnia had an AHI ≥ 5. Two of them had an AHI > 15 and these would be missed if our two-step strategy was applied.

We used nasal flow, instead of oximetry, simply because Philips NV funded this study and could easily provide a large number of Philips Respironics NFlow recorders (RU-sleeping, Philips Respironics). Three different single NFlow devices (SleepCheck, Flow Wizard, RU-sleeping) and one NFlow-oximetry combined device (ApneaLink) have been tested against PSG, all with high agreement for OSAS.18,39,42,43 In two studies, oximetry and NFlow recording did have equivalent accuracy for diagnosing OSAS in the home setting.43,44 Chai-Coetzer et al.39 reported less data loss (3%) (with oximetry) compared to NFlow (9%). We found 8 of 184 (4.3%) invalid NFlow recordings. The RU-sleeping flow recorder, used in this study, is a small easy to use recorder, which can even be sent by post and applied after reading the included instruction.

The sensitivity of 63.1% found in our study can perhaps be interpreted as moderate. However, in a healthy, almost asymptomatic population, this is probably the best result. Almost two thirds of the true OSAS employees could be identified with this relatively simple two-step strategy. Due to large numbers of subjects without having the disease in this setting, the primary goal in screening is often to correctly exclude subjects without the disease. Hence, a test strategy with a high specificity (here 90%), and therefore high numbers of true negatives and few false positives is essential.

The cost savings of our two-step strategy will be substantial for community screening compared with a quick questionnaire only; for the STOPBANGQ and BerlinQ this amounts to a difference of 324 (405 − 81) and 256 (337 − 81) diagnostic sleep studies (PSG or portable monitoring in clinic or at home), respectively, minus the extra costs for the cheap single channel NFlow recording at home in the intermediate group of the PhilipsQ, which have to be done in 27.2% or 272 subjects in the given example in 1,000 subjects with 10% OSAS prevalence (Tables 6 and 7).

In conclusion, a two-step screening strategy with the Phil-ipsQ and subsequent nasal flow recording is a promising way to screen for OSAS in a large group of healthy workers.

DISCLOSURE STATEMENT

Home sleep recording by the Netherlands Slaap Instituut (http://nederlandsslaapinstituut.nl) and data-collection by HumanCapitalCare (www.humancapitalcare.nl) was sponsored by Philips NV, Eindhoven, The Netherlands. The Department of Research Methodology, Measurement and Data Analysis, of the University of Twente, Enschede, The Netherlands received a grant of Philips NV, Eindhoven, the Netherlands for support in performing the statistical analyses. Philips NV Netherland had no access to employee data or study results, and was not involved in manuscript preparation or writing. Dr. Randerath has received research support and participated in speaking engagements for Weinmann, ResMed, Inspire, and Respironics and has consulted for Weinmann.

Dr. Verbraecken is on the speakers bureau of Philips. Dr. Eijsvogel consults for Linde. The other authors have indicated no financial conflicts of interest. The study was performed at the Medisch Spectrum Twente Hospital, Pulmonary and Sleep Department Haaksbergerstraat 55. 7513 ER Enschede, The Netherlands. There was no off-label or investigational use.

ACKNOWLEDGMENTS

The authors are indebted to Piet-Hein van Mechelen (chairman Dutch Sleep Apnea organization (http://www.apneuvereniging.nl) for practical study coordination and support. We thank Reindert P.J. van Steenwijk, Pulmonary and Sleep Physician, Academic Medical Centrum, Amsterdam, for critical review of the manuscript.

ABBREVIATIONS

AHI

apnea-hypopnea index

AIS

Athens Insomnia Scale

BerlinQ

Berlin questionnaire

BMI

body mass index

CFI

Comparative Fit Index

ESS

Epworth sleepiness scale

IRT

item response theory

NFlow

nasal flow

NREM

non rapid eye movement

NPV

negative predictive value

OSAS

obstructive sleep apnea syndrome

PhilipsQ

Philips questionnaire

Q–number

question with specific number

PSG

polysomnography

PPV

positive predictive value

RMSEA

Root Mean Square Error of Approximation

STOPBANGQ

STOPBANG questionnaire

STOPQ

STOP questionnaire

TLI

Tucker Lewis Index

jcsm.12.4.555s1.pdf (161.9KB, pdf)

REFERENCES

  • 1.Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S. The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med. 1993;328:1230–5. doi: 10.1056/NEJM199304293281704. [DOI] [PubMed] [Google Scholar]
  • 2.Baumel MJ, Maislin G, Pack AI. Population and occupational screening for obstructive sleep apnea: are we there yet? Am J Respir Crit Care Med. 1997;155:9–14. doi: 10.1164/ajrccm.155.1.9001281. [DOI] [PubMed] [Google Scholar]
  • 3.Seetho IW, Wilding JP. Screening for obstructive sleep apnoea in obesity and diabetes--potential for future approaches. Eur J Clin Invest. 2013;43:640–55. doi: 10.1111/eci.12083. [DOI] [PubMed] [Google Scholar]
  • 4.Boyko EJ. Ruling out or ruling in disease with the most sensitive or specific diagnostic test: short cut or wrong turn? Med Decis Making. 1994;14:175–9. doi: 10.1177/0272989X9401400210. [DOI] [PubMed] [Google Scholar]
  • 5.Abrishami A, Khajehdehi A, Chung F. A systematic review of screening questionnaires for obstructive sleep apnea. Can J Anaesth. 2010;57:423–38. doi: 10.1007/s12630-010-9280-x. [DOI] [PubMed] [Google Scholar]
  • 6.Netzer NC, Stoohs RA, Netzer CM, Clark K, Strohl KP. Using the Berlin Questionnaire to identify patients at risk for the sleep apnea syndrome. Ann Intern Med. 1999;131:485–91. doi: 10.7326/0003-4819-131-7-199910050-00002. [DOI] [PubMed] [Google Scholar]
  • 7.Hrubos-Strom H, Randby A, Namtvedt SK, et al. A Norwegian population-based study on the risk and prevalence of obstructive sleep apnea. The Akershus Sleep Apnea Project (ASAP) J Sleep Res. 2011;20:162–70. doi: 10.1111/j.1365-2869.2010.00861.x. [DOI] [PubMed] [Google Scholar]
  • 8.Kang K, Park KS, Kim JE, et al. Usefulness of the Berlin Questionnaire to identify patients at high risk for obstructive sleep apnea: a population-based door-to-door study. Sleep Breath. 2013;17:803–10. doi: 10.1007/s11325-012-0767-2. [DOI] [PubMed] [Google Scholar]
  • 9.Simpson L, Hillman DR, Cooper MN, et al. High prevalence of undiagnosed obstructive sleep apnoea in the general population and methods for screening for representative controls. Sleep Breath. 2013;17:967–73. doi: 10.1007/s11325-012-0785-0. [DOI] [PubMed] [Google Scholar]
  • 10.Ramachandran SK, Josephs LA. A meta-analysis of clinical screening tests for obstructive sleep apnea. Anesthesiology. 2009;110:928–39. doi: 10.1097/ALN.0b013e31819c47b6. [DOI] [PubMed] [Google Scholar]
  • 11.Gurubhagavatula I, Maislin G, Nkwuo JE, Pack AI. Occupational screening for obstructive sleep apnea in commercial drivers. Am J Respir Crit Care Med. 2004;170:371–6. doi: 10.1164/rccm.200307-968OC. [DOI] [PubMed] [Google Scholar]
  • 12.Chung F, Yegneswaran B, Liao P, et al. STOP questionnaire: a tool to screen patients for obstructive sleep apnea. Anesthesiology. 2008;108:812–21. doi: 10.1097/ALN.0b013e31816d83e4. [DOI] [PubMed] [Google Scholar]
  • 13.Gilley WF, Uhlig GE. Factor analysis and ordinal data. Education. 1993;114:258–64. [Google Scholar]
  • 14.Soldatos CR, Dikeos DG, Paparrigopoulos TJ. Athens Insomnia Scale: validation of an instrument based on ICD-10 criteria. J Psychosom Res. 2000;48:555–60. doi: 10.1016/s0022-3999(00)00095-7. [DOI] [PubMed] [Google Scholar]
  • 15.Soldatos CR, Dikeos DG, Paparrigopoulos TJ. The diagnostic validity of the Athens Insomnia Scale. J Psychosom Res. 2003;55:263–7. doi: 10.1016/s0022-3999(02)00604-9. [DOI] [PubMed] [Google Scholar]
  • 16.Johns MW. Reliability and factor analysis of the Epworth Sleepiness Scale. Sleep. 1992;15:376–81. doi: 10.1093/sleep/15.4.376. [DOI] [PubMed] [Google Scholar]
  • 17.Buysse DJ, Reynolds CF, III, Monk TH, Berman SR, Kupfer DJ. The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res. 1989;28:193–213. doi: 10.1016/0165-1781(89)90047-4. [DOI] [PubMed] [Google Scholar]
  • 18.Grover SS, Pittman SD. Automated detection of sleep disordered breathing using a nasal pressure monitoring device. Sleep Breath. 2008;12:339–45. doi: 10.1007/s11325-008-0181-y. [DOI] [PubMed] [Google Scholar]
  • 19.Iber C, Ancoli-Israel S, Chesson A, Quan SF for the American Academy of Sleep Medicine. 1st ed. Westchester, IL: American Academy of Sleep Medicine; 2007. The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications. [Google Scholar]
  • 20.Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force. Sleep. 1999;22:667–89. [PubMed] [Google Scholar]
  • 21.Eijsvogel M, Schimsheimer R, Vos P, et al. Diagnostiek en behandeling van het obstructief slaapapneu syndroom bij volwassenen. van Zuiden. 2009 [Google Scholar]
  • 22.Hays RD, Morales LS, Reise SP. Item response theory and health outcomes measurement in the 21st century. Med Care. 2000;38:1128–42. doi: 10.1097/00005650-200009002-00007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.van den Berg SM, Glas CA, Boomsma DI. Variance decomposition using an IRT measurement model. Behav Genet. 2007;37:604–16. doi: 10.1007/s10519-007-9156-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Bartholomew DJ, Steele F, Moustaki I, Galbraith JI. Boca Raton, FL: Chapman & Hall/CRC; 2008. Analysis of multivariate social science data. [Google Scholar]
  • 25.Jöreskog KG, Moustaki I. Factor analysis of ordinal variables: a comparison of three approaches. Multivar Behav Res. 2001;36:347–87. doi: 10.1207/S15327906347-387. [DOI] [PubMed] [Google Scholar]
  • 26.Vermunt JK, Magidson J. Factor analysis with categorical indicators: a comparison between traditional and letent class approaches. In: Van der Ark A, Croon MA, Sijtsma K, editors. New developments in categorical data analysis for the social and behavioural sciences. Mahwah, NJ: Lawrence Erlbaum Associates; 2005. pp. 41–62. [Google Scholar]
  • 27.Siemons L, Ten Klooster PM, Taal E, et al. Validating the 28-Tender Joint Count using item response theory. J Rheumatol. 2011;38:2557–64. doi: 10.3899/jrheum.110436. [DOI] [PubMed] [Google Scholar]
  • 28.Sass DA, Schmitt TA. A comparative investigation of rotation criteria within exploratory factor analysis. Multivar Behav Res. 2010;45:73–103. doi: 10.1080/00273170903504810. [DOI] [PubMed] [Google Scholar]
  • 29.Samejima F. Estimation of latent ability using a response pattern of graded scores. Psychometrika Monograph Supplement. 1969;34:1–100. [Google Scholar]
  • 30.Asparouhov T, Muthen B. Computationally efficient estimation of multilevel high-dimensional latent variable models. Proceedings of the 2007 JSM meeting; Salt Lake City. Utah. 2007. pp. 2531–5. Section on Statistics in Epidemiology. [Google Scholar]
  • 31.Stevens JP. Hillsdale, NJ: Erlbaum; 1980. Applied multivariate statistics for the social sciences. [Google Scholar]
  • 32.Hu L, Bentler PM. Cutoff criteria for fit indexes in covariance structure analysis: Conventional criteria versus new alternatives. Structural Equation Modeling: A Multidisciplinary Journal. 1999;6:1–55. [Google Scholar]
  • 33.Cowan DC, Allardice G, Macfarlane D, et al. Predicting sleep disordered breathing in outpatients with suspected OSA. BMJ Open. 2014;4:e004519. doi: 10.1136/bmjopen-2013-004519. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Flemons WW, Whitelaw WA, Brant R, Remmers JE. Likelihood ratios for a sleep apnea clinical prediction rule. Am J Respir Crit Care Med. 1994;150:1279–85. doi: 10.1164/ajrccm.150.5.7952553. [DOI] [PubMed] [Google Scholar]
  • 35.Maislin G, Pack AI, Kribbs NB, et al. A survey screen for prediction of apnea. Sleep. 1995;18:158–66. doi: 10.1093/sleep/18.3.158. [DOI] [PubMed] [Google Scholar]
  • 36.Rowley JA, Aboussouan LS, Badr MS. The use of clinical prediction formulas in the evaluation of obstructive sleep apnea. Sleep. 2000;23:929–38. doi: 10.1093/sleep/23.7.929. [DOI] [PubMed] [Google Scholar]
  • 37.Takegami M, Hayashino Y, Chin K, et al. Simple four-variable screening tool for identification of patients with sleep-disordered breathing. Sleep. 2009;32:939–48. [PMC free article] [PubMed] [Google Scholar]
  • 38.Caffo B, Diener-West M, Punjabi NM, Samet J. A novel approach to prediction of mild obstructive sleep disordered breathing in a population-based sample: the Sleep Heart Health Study. Sleep. 2010;33:1641–8. doi: 10.1093/sleep/33.12.1641. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Chai-Coetzer CL, Antic NA, Rowland LS, et al. A simplified model of screening questionnaire and home monitoring for obstructive sleep apnoea in primary care. Thorax. 2011;66:213–9. doi: 10.1136/thx.2010.152801. [DOI] [PubMed] [Google Scholar]
  • 40.Beneto A, Gomez-Siurana E, Rubio-Sanchez P. Comorbidity between sleep apnea and insomnia. Sleep Med Rev. 2009;13:287–93. doi: 10.1016/j.smrv.2008.09.006. [DOI] [PubMed] [Google Scholar]
  • 41.Luyster FS, Buysse DJ, Strollo PJ., Jr Comorbid insomnia and obstructive sleep apnea: challenges for clinical practice and research. J Clin Sleep Med. 2010;6:196–204. [PMC free article] [PubMed] [Google Scholar]
  • 42.Rofail LM, Wong KK, Unger G, Marks GB, Grunstein RR. The utility of single-channel nasal airflow pressure transducer in the diagnosis of OSA at home. Sleep. 2010;33:1097–1105. doi: 10.1093/sleep/33.8.1097. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.de Almeida FR, Ayas NT, Otsuka R, et al. Nasal pressure recordings to detect obstructive sleep apnea. Sleep Breath. 2006;10:62–9. doi: 10.1007/s11325-005-0042-x. [DOI] [PubMed] [Google Scholar]
  • 44.Rofail LM, Wong KK, Unger G, Marks GB, Grunstein RR. Comparison between a single-channel nasal airflow device and oximetry for the diagnosis of obstructive sleep apnea. Sleep. 2010;33:1106–14. doi: 10.1093/sleep/33.8.1106. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

jcsm.12.4.555s1.pdf (161.9KB, pdf)

Articles from Journal of Clinical Sleep Medicine : JCSM : Official Publication of the American Academy of Sleep Medicine are provided here courtesy of American Academy of Sleep Medicine

RESOURCES