Abstract
A simple and rapid procedure has been developed for the complexometric titration of serum calcium and magnesium using “plasmocorinth B” as indicator. Both determinations can be carried out from the same 0.5 ml. sample. The method is in good agreement with the established calcium and magnesium methods.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- COPELAND B. E. Standard deviation; a practical means for the measurement and control of the precision of clinical laboratory determinations. Am J Clin Pathol. 1957 May;27(5):551–558. doi: 10.1093/ajcp/27.5.551. [DOI] [PubMed] [Google Scholar]
- DAVIS S. A flame photometric method for the determination of plasma magnesium after hydroxyquinoline precipitation. J Biol Chem. 1955 Oct;216(2):643–651. [PubMed] [Google Scholar]
- ORANGE M., RHEIN H. C. Microestimation of magnesium in body fluids. J Biol Chem. 1951 Mar;189(1):379–386. [PubMed] [Google Scholar]
- TSAO M. U. Colorimetric determination of serum calcium. J Biol Chem. 1952 Nov;199(1):251–257. [PubMed] [Google Scholar]
- VALLEE B. L. Simultaneous determination of sodium, potassium, calcium, magnesium and strontium by a new multichannel flame-spectrometer. Nature. 1954 Dec 4;174(4440):1050–1051. doi: 10.1038/1741050a0. [DOI] [PubMed] [Google Scholar]