Skip to main content
PLOS ONE logoLink to PLOS ONE
. 2016 Mar 21;11(3):e0152088. doi: 10.1371/journal.pone.0152088

Comparing the Curative Effects between Femtosecond Laser-Assisted Cataract Surgery and Conventional Phacoemulsification Surgery: A Meta-Analysis

Xinyi Chen 1, Kailin Chen 1, Jiliang He 2, Ke Yao 1,*
Editor: James Fielding Hejtmancik3
PMCID: PMC4801419  PMID: 26999612

Abstract

Purpose

To compare the outcomes of femtosecond laser-assisted cataract surgery (FLACS) with those of conventional phacoemulsification surgery (CPS) for age-related cataracts.

Methods

A comprehensive literature search of PubMed, EMBASE, and the Cochrane Controlled Trials Register was conducted to identify randomized controlled trials (RCT) and comparative cohort studies comparing FLACS with CPS. Endothelial cell loss percentage (ECL%), central corneal thickness (CCT), corrected and uncorrected distant visual acuity (CDVA and UDVA), and mean absolute error (MAE) of refraction were used as primary outcomes. Secondary outcomes included surgically induced astigmatism (SIA), mean effective phacoemulsification time (EPT), phacoemulsification power and circularity of the capsulorhexis.

Results

Nine RCTs and fifteen cohort studies including 4,903 eyes (2,861 in the FLACS group and 2,072 in the CPS group) were identified. There were significant differences between the two groups in ECL% at one week, about one month and three months postoperatively, in CCT at one day, about one month postoperatively and at the final follow-up, in CDVA at one week postoperatively, and in UDVA at the final follow-up. Significant differences were also observed in MAE, EPT, phacoemulsification power, and the circularity of capsulorhexis. However, no significant differences were observed in CDVA at one week postoperatively or in surgically induced astigmatism.

Conclusions

Compared to CPS, FLACS is a safer and more effective method for reducing endothelial cell loss and postoperative central corneal thickening as well as achieving better and faster visual rehabilitation and refractive outcomes. However, there is no difference in final CDVA and surgically induced astigmatism between the two groups.

Introduction

Cataract is the leading cause of reversible blindness worldwide, and it can be effectively treated with cataract surgery. With the development of improved equipment and technology over the past few years, cataract surgery is now one of the safest and most successful major surgical procedures performed worldwide. [1] Phacoemulsification is currently the predominant surgical technique employed in developed countries. [2,3] Although conventional phacoemulsification surgery (CPS) provides good visual acuity and rarely causes complications, patients still expect to achieve more rapid visual rehabilitation and experience fewer traumas.

The use of femtosecond lasers in cataract surgery has recently become popular. Femtosecond laser technology was initially used to create the flap in laser-assisted in situ keratomileusis (LASIK). [4] After being expanded to cataract surgery, femtosecond laser technology was used to perform lens fragmentation, anterior capsulotomy, and self-sealing corneal incisions. [5] Femtosecond laser-assisted cataract surgery (FLACS) offers numerous advantages over current surgical techniques. Studies have shown that use of FLACS leads to more accurate capsulorhexis than the manual procedure in CPS. [6,7] The quality of capsulorhexis has an effect on intraocular lens (IOL) position [8] and on the predictability in the IOL power calculation [5,9], thus affecting the visual and refractive outcomes. Previous studies have shown that the pre-treatment of cataracts with lasers using FLACS leads to a reduced IOL tilt and improved biometry predictability. [7,10,11] The corneal endothelium plays an important role in maintaining corneal transparency and normal thickness [12], and phacoemulsification time and energy are known to directly cause endothelial cell loss. [1315] Many recent studies have found that FLACS helps to reduce effective phacoemulsification time (EPT) and the required phacoemulsification energy, thereby diminishing corneal endothelial injury. [16,17] Injury reduction of corneal endothelial cells contributes to shorten the recovery period and improve visual outcomes. [1,6] Based on the advantages of FLACS over CPS, some researchers have even predicted that the femtosecond laser will become the standard method of cataract extraction within ten years. [18]

The laser in FLACS is helpful for performing the self-sealing corneal incision, accurate capsulorhexis, and nuclear fragmentation. Notwithstanding the benefits of FLACS, many studies have compared the two techniques from several perspectives with varying results. Nevertheless, some ophthalmologists still doubt about the benefit from FLACS. [19]

There has only been one recently published meta-analysis [20] comparing the efficacy and safety of CPS and FLACS. The study included nine randomized controlled trials (RCTs) and concluded that FLACS resulted in significantly lower central corneal thickness (CCT) at one day follow-up, achieved a better corrected distant visual acuity (CDVA) at one week and six months postoperatively, and reduced phacoemulsification energy and EPT. However, because of the small sample size in this meta-analysis, the presence of bias and significant heterogeneity could not be ruled out. In addition, conducting a double blind RCT (i.e., in which patients and surgeons do not know which technique will be used before the operation) is sometimes unethical and difficult to carry out in clinical trials. A prospective randomized intraindividual cohort study [17] was also included in this RCT meta-analysis. To address the issue of small sample size and to provide more reliable and convincing evidence, a meta-analysis evaluating the differences in outcomes between FLACS and CPS was performed, with high-quality clinical cohort studies included.

Materials and Methods

The meta-analysis was performed according to generally accepted methods. [21,22]

Search strategy

PubMed, EMBASE, and the Cochrane Controlled Trials Register were searched for articles dated up to July 2015. A full-text search was conducted using the following terms: femtosecond OR femtolaser AND cataract. No restriction was placed on the language of the publication. The reference sections of the relevant reviews and original articles were also scanned for potential trials that may have been missed in the primary searches.

Inclusion and exclusion criteria

Only reports of RCTs and comparative cohort studies comparing the outcomes of FLACS and CPS for age-related cataracts were included. Participants in the trials were patients with decreased visual acuity secondary to cataracts and no other eye disorders capable of compromising vision (e.g., amblyopia, glaucoma, diabetic retinopathy, or macular degeneration). At least one of the outcome measures in each included study was required.

Screening process

Two independent reviewers (XY.C and KL.C) first conducted a preliminary review of the titles and abstracts; then, the full articles were analyzed to select the studies that met our predefined criteria. Disagreement between two reviewers was resolved through careful discussion—involving a third reviewer when necessary—until a consensus was reached.

Quality assessment

Cochrane Collaboration’s tool for risk of bias [23] was used by two independent reviewers to evaluate the quality of the included RCTs. In short, the domains of sequence generation, allocation concealment, and selective outcome reporting were each addressed in the tool by a single entry for each study. The blinding of participants and personnel, the blinding of outcome assessment, and incomplete outcome data were also included in this tool. All of these parameters were graded as low risk of bias, high risk of bias, or unclear risk of bias, which indicated either a lack of information or uncertainty over the potential for bias.

The Newcastle-Ottawa Scale (NOS) [24] was used for quality assessment of the cohort study. This scale uses a total of nine stars: four in patient selection, two in comparability, and three in outcome assessment. A score ≥ 7 indicates good quality.

Two independent reviewers conducted this process, and discussion was used to resolve discrepancies.

Data extraction

A standard form was used to extract the data, including the authors of each study, country and year of publication, study design, numbers, age and sex of patients, eye sample size, left-right eye proportion, follow-up duration and withdrawals. A second reviewer double-checked all data.

Outcome measures

The measured outcomes included endothelial cell loss percentage, central corneal thickness, corrected distant visual acuity and uncorrected distant visual acuity, mean absolute error of refraction, surgically induced astigmatism, mean effective phacoemulsification time, phacoemulsification power, and circularity of the capsulorhexis.

For those studies that only reported absolute values for endothelial cell loss (ECL) count at the baseline and endpoint, endothelial cell loss percentage (ECL%) and the SD of the ECL% (SDECL%) were calculated as follows:

ECL=ECDbaseline-ECDendpoint;SDECL=SDbaseline2+SDendpoint2-2ρSDbaselineSDendpoint

where ρ=σpre2-σpost2-σ22σpreσpost;

ECL%=ECL×100%ECDbaseline,SDECL%=SDECLECDbaseline

For studies reporting visual outcomes not in the logMAR system but rather in the Snellen system: [25]

BCVAlogMAR=logBCVASnellen,SDlogMAR=log e×SDSnellen(whenBCVASnellen1)

Statistical analysis

All statistical analyses were performed using RevMan software (version 5.3; Cochrane Collaboration, Oxford, United Kingdom). The weighted mean difference (WMD) with a 95% CI was calculated for the continuous outcomes. A p-value of less than 0.05 was considered statistically significant. Statistical heterogeneity was tested using the chi-square and I2. Fixed-effects models were used unless significant evidence of statistical heterogeneity or clinical diversity was found. However, for results showing significant heterogeneity (I2 > 50%), a random-effects meta-analysis was performed. Publication bias was measured using a Begg funnel plot. A sensitivity analysis was conducted to assess whether the results were affected by the excessive weight of a single study. The sensitivity analysis was performed by a one-study-removed analysis to assess how the results would change if a single study were omitted. [26]

Results

Literature search

The flowchart in Fig 1 shows the literature search process. After duplicates were removed, the titles and abstracts of 639 potentially relevant articles were scanned and 605 studies were excluded. Thirty-four full-text articles were then assessed for eligibility. Nine of them were excluded because the data were not relevant to our outcomes of interest, and one of them was excluded because it focused on another, different research question. Finally, 24 articles [911,16,17,2745] meeting all of the predefined criteria were included in this meta-analysis.

Fig 1. Flow diagram of the literature search in this meta-analysis.

Fig 1

Characteristics of included studies

In the present meta-analysis, nine included studies were random clinical trials, and the other fifteen included studies were comparative cohort studies. Table 1 shows the characteristics of the 24 studies. The quality assessment of the RCTs is displayed in S1 Fig and that of the comparative cohort studies is shown in S1 Table. Overall, 4,903 eyes (2,861 assigned to the FLACS group and 2,072 assigned to the CPS group were analyzed. The mean age of the patients in these included studies ranged from 55 to 73 years. Four studies were completed in Australia, one in Singapore, one in India, and the remainder in Europe. Fifteen of these studies reported that approximately 44.2% of patients were male. The follow-up duration ranged from three weeks to six months.

Table 1. Characteristics of included studies.

FLACS, femtosecond laser-assisted cataract surgery; CPS, conventional phacoemulsification surgery; RCT, randomized controlled trial; NA, not available.

Study ID Country Study design Age Sex (Male: Female) No. of patients No. of eyes Follow-up
FLACS CPS FLACS CPS FLACS CPS FLACS CPS
Abell 2013a Australia cohort 72.5±10.5 53:47 33:43 100 76 100 76 4 weeks
Takacs 2012 Hungary RCT 65.81±12.42 66.93±0.99 10:28 15:23 38 38 38 38 1 month
Chee 2015 Singapore cohort 64.5±9.86 65.5±9.39 NA NA NA NA 794 420 6 weeks
Nagy 2011 Hungary RCT 65±13 68±15 15:39 17:40 53 52 54 57 1 week
Filkorn 2012 Hungary RCT 65.18±12.6 64.37±12.37 NA NA 77 57 77 57 9 weeks
Conrad-Hengerer 2013 Germany cohort 70.9 70.9 27:46 27:46 73 73 73 73 3 months
Conrad-Hengerer 2014a Germany cohort 72±10 73±10 NA NA 400 400 400 400 NA
Ecsedy 2011 Hungary cohort 58.85±15.27 66.85±11.77 8:12 5:15 20 20 20 20 1 month
Conrad-Hengerer 2012 Germany cohort 70±11 72±8 30:27 28:24 57 52 57 52 4 weeks
Abell 2014 Australia cohort 72.5±10.1 220:270 NA NA 405 215 6 months
Reddy 2013 India RCT 58.5±11.6 61.3±9.7 30:26 37:26 56 63 56 63 1 day
Krarup 2014 Denmark cohort NA NA NA NA 47 47 47 47 3 months
Nagy 2014 Hungary RCT 70.4±11.57 62.27±13.41 NA NA 20 20 20 20 3 months
Mastropasqua 2014a Italy RCT 70.2±2.9 70.5±3.2 NA NA 30 30 30 30 180 days
Schargus 2015 Germany RCT 71.8 71.8 15:22 15:22 37 37 37 37 6 months
Conrad-Hengerer 2014b Germany RCT 71.3 71.3 46:58 46:58 104 104 104 104 6 months
Schultz 2015 Germany cohort 70.96±9.89 69.94±10.48 25:25 23:27 50 50 50 50 3 days
Packer 2014 Germany cohort 67.75±11.29 69.42±12.56 45:43 24:38 55 31 88 62 1 month
Nagy 2012 Hungary cohort 55.17±17.25 62±14.27 7:5 5:8 12 13 12 13 2 months
Mastropasqua 2014b Italy RCT 69.3±3.4; 69.2±2.7 69.1±3.9 NA NA 30+30 30 30+30 30 180 days
Lawless 2012 Australia cohort NA NA NA NA NA NA 61 29 12 weeks
Abell 2013b Australia cohort 72.8±10.5 71.8±10.8 69:81 23:28 150 51 150 51 3 weeks
Daya 2014 UK cohort 64.7±8.5 64.1±8.9 NA NA NA NA 108 108 NA
Kranitz 2011 Hungary cohort 63.78±13.97 71.69±11.34 5:15 6:14 20 20 20 20 1 year

Primary outcomes

Endothelial cell loss percentage

There were seven studies reporting endothelial cell loss percentage at different time points. The mean ECL% in the FLACS group was significantly lower than that in the CPS group at one week (WMD: -2.93, 95% CI: -5.63 to -0.24, P = .03), approximately one month (WMD: -2.07, 95% CI: -2.94 to -1.19, P < .001), and three months (WMD: -4.67, 95% CI: -7.81 to -1.54, P = .003) postoperatively (Fig 2).

Fig 2. Forest plot comparison of ECL% after treatment with FLACS and CPS.

Fig 2

(A) One week. (B) Three to four weeks. (C) Three months postoperatively.

Central corneal thickness

There were four studies reporting central corneal thickness at different time points. The thickness of the central cornea in the FLACS group was significantly lower than in the CPS group at one day (WMD: -16.63, 95% CI: -23.40 to -9.86, P < .001), approximately one month (WMD: -8.69, 95% CI: -15.58 to -1.80, P = .01), and three to six months (WMD: -6.00, 95% CI: -11.41 to -0.60, P = .03) postoperatively. (Fig 3)

Fig 3. Forest plot comparison of CCT after treatment with FLACS and CPS.

Fig 3

(A) One day. (B) Three to four weeks. (C) Three to six months postoperatively.

Visual outcomes

The corrected distant visual acuity was compared between the two groups at one week, one month, and at more than one month postoperatively (at the end of the follow-up period). The forest plots in Fig 4 shows that the CDVA in the FLACS group was significantly better than in the CPS group one week postoperatively (WMD: -0.03, 95% CI: -0.06 to -0.01, P = .01), and no significant differences of CDVA between the two groups one month postoperatively and at the end of the follow-up period (WMD: -0.01, 95% CI: -0.04 to 0.02, P = .54; WMD: -0.01, 95% CI: -0.01 to 0.00, 95% CI: -0.04 to 0.02, P = .07). However, the uncorrected distant visual acuity at the end of the follow-up period after FLACS appeared to be significantly better than after CPS (WMD: -0.07, 95% CI: -0.14 to 0.00, P = .05) based on a random-effects model (Fig 5).

Fig 4. Forest plot comparison of CDVA after treatment with FLACS and CPS.

Fig 4

(A) One week. (B) One month. (C) Final follow-up

Fig 5. Forest plot comparison of UDVA at final follow-up after treatment with FLACS and CPS.

Fig 5

Refractive outcomes

The mean absolute error of refraction is the difference between predicted and achieved postoperative spherical equivalent refraction, so mean absolute error (MAE) was used to analyze refractive outcomes. Six studies (including 1,696 eyes) compared the MAE after FLACS and CPS. The forest plot of the comparison in Fig 6 shows that the MAE of FLACS is significantly lower than that of CPS (WMD: -0.03, 95% CI: -0.06 to -0.01, P = .05).

Fig 6. Forest plot comparison of MAE of spherical equivalent refraction after treatment with FLACS and CPS.

Fig 6

Secondary outcomes

Surgically induced astigmatism

Only two studies (including 100 eyes) compared surgically induced astigmatism (SIA) after FLACS and CPS. An analysis of these data showed no significant difference between the two groups (WMD: 0.05, 95% CI: -0.03 to 0.12, P = .26, I2 = 0%), as shown in S2 Fig.

Effective phacoemulsification time

Ten studies (including 1,174 eyes in the FLACS group and 1,027 eyes in the CPS group) compared effective phacoemulsification time during surgery. There was a significant difference between the two groups in favor of the FLACS group (WMD: -2.13, 95% CI: -2.60 to -1.66, P < .001, I2 > 50%), as shown in S3 Fig.

Phacoemulsification power

Two studies compared cumulative dissipated energy (CDE) and three studies compared mean phacoemulsification power (MP) between the FLACS and the CPS groups. Two subgroups (CDE and MP) were added to assess phacoemulsification power, as shown in S4 Fig. Seventy-seven eyes in the FLACS group and seventy-seven eyes in the CPS group showed that FLACS required significantly less cumulative dissipated energy (WMD: -2.23, 95% CI: -3.79 to -0.67, P = .005, I2 = 0%). Despite the high heterogeneity, studies reporting MP showed that the mean phacoemulsification power in the FLACS group was significantly lower than in the CPS group (WMD: -7.09, 95% CI: -7.64 to -6.55, P < .001, I2 > 50%). Therefore, the overall effect in phacoemulsification power favored FLACS (WMD: -6.57, 95% CI: -7.08 to -6.05, P < .001, I2 > 50%).

Circularity of capsulorhexis

Circularity is a parameter used for determining the regularity of capsulorhexis shape according to the following formula: circularity = 4π (area/perimeter2). Circularity values of 1.0 indicate a perfect circle. Four studies reported the circularity of capsulorhexis using the random effects model. The FLACS group had a significantly higher quality of circularity compared with the CPS group (WMD: 0.06, 95% CI: 0.03 to 0.09, P < .001, I2 > 50%), as shown in S5 Fig.

Heterogeneity and publication bias

Some of the secondary outcomes displayed great heterogeneity. The heterogeneities of EPT, mean phacoemulsification power, and circularity were significant, and manually dropping eligible studies did not provide good results. No significant publication bias was demonstrated in the funnel plot.

Discussion

The results of the present meta-analysis provide evidence that FLACS is safer, more accurate, causes fewer traumas, and achieves better visual outcomes than CPS. There were statistically significant differences in ECL%, CCT, CDVA at one day after surgery, UDVA at the end of the follow-up period, MAE, mean EPT, phacoemulsification power, and circularity of capsulorhexis between the FLACS and the CPS groups. However, no significant difference was found in surgically induced astigmatism between the two groups.

The CPS group had lost more endothelial cells than the FLACS group at one week, approximately one month, and three months postoperatively. Various factors can affect endothelial alterations including ultrasound time [46] and energy [47], irrigating solution [48], and the surgeon’s experience. Phacoemulsification time and energy are the most significant factors influencing endothelial cell damage. [13,14] In the present meta-analysis, both effective phacoemulsification time and phacoemulsification power favored the FLACS group. In addition, there was a direct relationship between endothelial cell loss and ultrasound power and time. [49] In contrast to the manual process of capsulorhexis and lens fragmentation in CPS, FLACS cataract pre-treatment reduces the amounts of potentially injurious ultrasound energy and time spent on lens emulsification. This means that the harmful effects of CPS on the endothelium are greater than those of FLACS. In addition, there is limited regenerative capacity of the corneal endothelium, a process that involves the self-repair of the endothelium through cell enlargement and migration. [12] That is, once the self-repair capacity of endothelium has been exceeded, long-term injury not only impacts the function of the endothelium but also its ability to withstand further injury. Therefore, when observing the different results at different time-points, it can be deduced that the reduction in EPT and phacoemulsification power not only contributes to reduced endothelial cell loss but also to the preservation of endothelial function and resistance to injury.

There was an increase in central corneal thickness in both groups, which reflects the development of central corneal edema after surgery. The corneal endothelium is responsible for maintaining corneal transparency and normal thickness. [12] Central corneal thickening always accompanies endothelial cell loss. When endothelial cell density significantly decreases, corneal edema may develop. [12] The central cornea in the CPS group was thicker than in the FLACS group at one day, one month, and three to six months postoperatively, suggesting that endothelial pump function was impaired, leading to corneal swelling. In addition, reduced corneal edema leads to faster visual recovery after IOL implantation. [17] This latter point is verified by our observation that the CDVA of patients in the FLACS group was much better at one week after surgery. However, a sensitivity analysis showed that if the final follow-up data from Abell’s 2014 study was excluded, the between-group differences became non-significant (WMD: 0.10, 95% CI: -9.33 to 9.52, P = .98, I2 = 0%). We infer that this is because the central corneas of patients in our CPS group were a little bit thicker than those of our FLACS group preoperatively, whereas in other articles, preoperative corneal thickness was nearly the same in both groups. Therefore, more experiments and additional data are required.

Visual rehabilitation is the most concerning problem for patients undergoing cataract surgery. FLACS leads to a better UDVA for patients at the final follow-up. CDVA is one of the best parameters for evaluating the quality and efficiency of a surgical technique. [46] Although there was no difference between the groups in the long-term comparison, the CDVA of the FLACS group was significantly better one week postoperatively, indicating that patients with FLACS can achieve rapid vision recovery, which is consistent with the central corneal thickness results. However, patients in both groups had excellent postoperative CDVA at the end of the follow-up period; this is why a significant difference was not observed between the CDVA values of the groups.

In the present meta-analysis, we observed that patients in the FLACS group obtained better circularity of capsulorhexis and experienced less mean absolute error than predicted. Previous studies have concluded that the type and shape of the capsulorhexis have a major effect on the IOL position. [9] The femtosecond laser-assisted capsulorhexis contributes to a more uniform shape, a more predictable size, and a more precise position. The improved capsulorhexis generally leads to a smaller variability in the actual IOL position compared to the precalculated one, which is expressed by a smaller MAE.

Besides the benefits and advantages of FLACS, financial issues should also be taken into consideration on the way of generalizing this new technology.[3] Some practitioners, especially well-skilled surgeons, still prefer CPS because they can also bring the patients good outcomes without the assistance of laser. And the extra dollars may affect their judgments on the choice of surgery procedure. However, as a clinician, better outcome consideration ranks above all else. Just like Australian patients’ free to extra FLACS costs, as the benefits of FLACS are proved, more and more insurance systems are thinking about covering these costs and then the cost considerations will mitigate. [18,19] As CPS gradually replaced extracapsular cataract extraction (ECCE), costs may decrease with the improvement and matureness of the technology. [19,50] And the wide adoption can amortize the capital costs. Therefore, FLACS will be more cost-effective and become a new option for surgeons and patients.

Inevitably, the present meta-analysis has several limitations. First, the limitations stem from the clinical trial itself. In some cases, it is not necessarily ethical for patients not to know which type of operation they will be undergoing. Cohort studies, which are not as reliable as RCTs, were therefore included in this meta-analysis. Second, these data were extracted from several trials, so it is difficult to unify the characteristics of patients, surgical conditions, surgeons, and data collection, all of which result in heterogeneity. Third, each of these studies solely focused on their particular fields of interest so that each outcome in this meta-analysis was derived from different studies.

Conclusions

In conclusion, compared to conventional phacoemulsification surgery, femtosecond laser-assisted cataract surgery is safer and more effective in reducing endothelial cell loss and postoperative central corneal thickening and achieving better visual and refractive outcomes. However, there are no differences in SIA between the groups. Further studies with more outcomes and larger patient populations are needed to support our results.

Supporting Information

S1 PRISMA Checklist. PRISMA Checklist.

(DOC)

S1 Table. Quality assessment of cohort studies on the Newcastle-Ottawa Scale.

(PDF)

S1 Fig. Risk of bias graph.

Review authors' judgments about each methodological quality item presented as percentages across included RCTs.

(TIF)

S2 Fig. Forest plot comparison of SIA after treatment with FLACS and CPS.

(TIF)

S3 Fig. Forest plot comparison of EPT after treatment with FLACS and CPS.

(TIF)

S4 Fig. Forest plot comparison of phacoemulsification power after treatment with FLACS and CPS.

(TIF)

S5 Fig. Forest plot comparison of circularity of capsulorhexis after treatment with FLACS and CPS.

(TIF)

Data Availability

All relevant data are within the paper and its Supporting Information files.

Funding Statement

This study was supported by Key Program of National Natural Science Foundation of China (No.81130018); Zhejiang Key Laboratory Fund of China (2011E10006) and Project of National Clinical Key Discipline of Chinese Ministry of Health.

References

  • 1.Roberts TV, Lawless M, Chan CC, Jacobs M, Ng D, Bali SJ, et al. Femtosecond laser cataract surgery: technology and clinical practice. Clinical & experimental ophthalmology. 2013;41(2):180–6. 10.1111/j.1442-9071.2012.02851.x . [DOI] [PubMed] [Google Scholar]
  • 2.Tabin G, Chen M, Espandar L. Cataract surgery for the developing world. Current opinion in ophthalmology. 2008;19(1):55–9. 10.1097/ICU.0b013e3282f154bd . [DOI] [PubMed] [Google Scholar]
  • 3.Uy HS, Edwards K, Curtis N. Femtosecond phacoemulsification: the business and the medicine. Current opinion in ophthalmology. 2012;23(1):33–9. 10.1097/ICU.0b013e32834cd622 . [DOI] [PubMed] [Google Scholar]
  • 4.Nordan LT, Slade SG, Baker RN, Suarez C, Juhasz T, Kurtz R. Femtosecond laser flap creation for laser in situ keratomileusis: six-month follow-up of initial U.S. clinical series. Journal of refractive surgery (Thorofare, NJ: 1995). 2003;19(1):8–14. . [DOI] [PubMed] [Google Scholar]
  • 5.Chen M, Swinney C, Chen M. Comparing the intraoperative complication rate of femtosecond laser-assisted cataract surgery to traditional phacoemulsification. International journal of ophthalmology. 2015;8(1):201–3. 10.3980/j.issn.2222-3959.2015.01.34 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.He L, Sheehy K, Culbertson W. Femtosecond laser-assisted cataract surgery. Current opinion in ophthalmology. 2011;22(1):43–52. 10.1097/ICU.0b013e3283414f76 . [DOI] [PubMed] [Google Scholar]
  • 7.Kranitz K, Takacs A, Mihaltz K, Kovacs I, Knorz MC, Nagy ZZ. Femtosecond laser capsulotomy and manual continuous curvilinear capsulorrhexis parameters and their effects on intraocular lens centration. Journal of refractive surgery (Thorofare, NJ: 1995). 2011;27(8):558–63. 10.3928/1081597X-20110623-03 . [DOI] [PubMed] [Google Scholar]
  • 8.Norrby S. Sources of error in intraocular lens power calculation. Journal of cataract and refractive surgery. 2008;34(3):368–76. 10.1016/j.jcrs.2007.10.031 . [DOI] [PubMed] [Google Scholar]
  • 9.Filkorn T, Kovacs I, Takacs A, Horvath E, Knorz MC, Nagy ZZ. Comparison of IOL power calculation and refractive outcome after laser refractive cataract surgery with a femtosecond laser versus conventional phacoemulsification. Journal of refractive surgery (Thorofare, NJ: 1995). 2012;28(8):540–4. Epub 2012/07/13. 10.3928/1081597x-20120703-04 . [DOI] [PubMed] [Google Scholar]
  • 10.Chee SP, Yang Y, Ti SE. Clinical outcomes in the first two years of femtosecond laser-assisted cataract surgery. American journal of ophthalmology. 2015;159(4):714–9. Epub 2015/01/31. 10.1016/j.ajo.2015.01.016 . [DOI] [PubMed] [Google Scholar]
  • 11.Kranitz K, Mihaltz K, Sandor GL, Takacs A, Knorz MC, Nagy ZZ. Intraocular lens tilt and decentration measured by Scheimpflug camera following manual or femtosecond laser-created continuous circular capsulotomy. Journal of refractive surgery (Thorofare, NJ: 1995). 2012;28(4):259–63. 10.3928/1081597X-20120309-01 . [DOI] [PubMed] [Google Scholar]
  • 12.Ho JW, Afshari NA. Advances in cataract surgery: preserving the corneal endothelium. Current opinion in ophthalmology. 2015;26(1):22–7. 10.1097/ICU.0000000000000121 . [DOI] [PubMed] [Google Scholar]
  • 13.Cho YK, Chang HS, Kim MS. Risk factors for endothelial cell loss after phacoemulsification: comparison in different anterior chamber depth groups. Korean journal of ophthalmology: KJO. 2010;24(1):10–5. 10.3341/kjo.2010.24.1.10 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Walkow T, Anders N, Klebe S. Endothelial cell loss after phacoemulsification: relation to preoperative and intraoperative parameters. Journal of cataract and refractive surgery. 2000;26(5):727–32. . [DOI] [PubMed] [Google Scholar]
  • 15.Hayashi K, Hayashi H, Nakao F, Hayashi F. Risk factors for corneal endothelial injury during phacoemulsification. Journal of cataract and refractive surgery. 1996;22(8):1079–84. . [DOI] [PubMed] [Google Scholar]
  • 16.Abell RG, Kerr NM, Vote BJ. Toward zero effective phacoemulsification time using femtosecond laser pretreatment. Ophthalmology. 2013;120(5):942–8. Epub 2013/03/08. 10.1016/j.ophtha.2012.11.045 . [DOI] [PubMed] [Google Scholar]
  • 17.Conrad-Hengerer I, Al Juburi M, Schultz T, Hengerer FH, Dick HB. Corneal endothelial cell loss and corneal thickness in conventional compared with femtosecond laser-assisted cataract surgery: three-month follow-up. Journal of cataract and refractive surgery. 2013;39(9):1307–13. Epub 2013/07/23. 10.1016/j.jcrs.2013.05.033 . [DOI] [PubMed] [Google Scholar]
  • 18.Ranka M, Donnenfeld ED. Femtosecond laser will be the standard method for cataract extraction ten years from now. Survey of ophthalmology. 2015;60(4):356–60. Epub 2015/04/05. 10.1016/j.survophthal.2015.02.001 . [DOI] [PubMed] [Google Scholar]
  • 19.Lipner M. Forgoing the femtosecond laser. Eye World. 2015. [Google Scholar]
  • 20.Chen X, Xiao W, Ye S, Chen W, Liu Y. Efficacy and safety of femtosecond laser-assisted cataract surgery versus conventional phacoemulsification for cataract: a meta-analysis of randomized controlled trials. Scientific reports. 2015;5:13123 10.1038/srep13123 . [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Egger M, Smith GD, Phillips AN. Meta-analysis: principles and procedures. Bmj. 1997;315(7121):1533–7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Pogue J, Yusuf S. Overcoming the limitations of current meta-analysis of randomised controlled trials. Lancet. 1998;351(9095):47–52. 10.1016/S0140-6736(97)08461-4 . [DOI] [PubMed] [Google Scholar]
  • 23.Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, et al. The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. Bmj. 2011;343:d5928 10.1136/bmj.d5928 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. European journal of epidemiology. 2010;25(9):603–5. 10.1007/s10654-010-9491-z . [DOI] [PubMed] [Google Scholar]
  • 25.Chen C, Zhu M, Sun Y, Qu X, Xu X. Bimanual microincision versus standard coaxial small-incision cataract surgery: meta-analysis of randomized controlled trials. European journal of ophthalmology. 2015;25(2):119–27. 10.5301/ejo.5000521 . [DOI] [PubMed] [Google Scholar]
  • 26.Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. Bmj. 1997;315(7109):629–34. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Abell RG, Allen PL, Vote BJ. Anterior chamber flare after femtosecond laser-assisted cataract surgery. Journal of cataract and refractive surgery. 2013;39(9):1321–6. Epub 2013/07/16. 10.1016/j.jcrs.2013.06.009 . [DOI] [PubMed] [Google Scholar]
  • 28.Abell RG, Kerr NM, Howie AR, Mustaffa Kamal MA, Allen PL, Vote BJ. Effect of femtosecond laser-assisted cataract surgery on the corneal endothelium. Journal of cataract and refractive surgery. 2014;40(11):1777–83. Epub 2014/09/14. 10.1016/j.jcrs.2014.05.031 . [DOI] [PubMed] [Google Scholar]
  • 29.Conrad-Hengerer I, Hengerer FH, Al Juburi M, Schultz T, Dick HB. Femtosecond laser-induced macular changes and anterior segment inflammation in cataract surgery. Journal of refractive surgery (Thorofare, NJ: 1995). 2014;30(4):222–6. Epub 2014/04/08. 10.3928/1081597x-20140321-01 . [DOI] [PubMed] [Google Scholar]
  • 30.Conrad-Hengerer I, Hengerer FH, Schultz T, Dick HB. Effect of femtosecond laser fragmentation on effective phacoemulsification time in cataract surgery. Journal of refractive surgery (Thorofare, NJ: 1995). 2012;28(12):879–83. Epub 2012/12/13. 10.3928/1081597x-20121116-02 . [DOI] [PubMed] [Google Scholar]
  • 31.Conrad-Hengerer I, Schultz T, Jones JJ, Hengerer FH, Dick B. Cortex removal after laser cataract surgery and standard phacoemulsification: a critical analysis of 800 consecutive cases. Journal of refractive surgery (Thorofare, NJ: 1995). 2014;30(8):516–20. Epub 2014/06/28. 10.3928/1081597x-20140624-01 . [DOI] [PubMed] [Google Scholar]
  • 32.Daya SM, Nanavaty MA, Espinosa-Lagana MM. Translenticular hydrodissection, lens fragmentation, and influence on ultrasound power in femtosecond laser-assisted cataract surgery and refractive lens exchange. Journal of cataract and refractive surgery. 2014;40(1):37–43. Epub 2013/11/26. 10.1016/j.jcrs.2013.07.040 . [DOI] [PubMed] [Google Scholar]
  • 33.Ecsedy M, Mihaltz K, Kovacs I, Takacs A, Filkorn T, Nagy ZZ. Effect of femtosecond laser cataract surgery on the macula. Journal of refractive surgery (Thorofare, NJ: 1995). 2011;27(10):717–22. Epub 2011/09/01. 10.3928/1081597x-20110825-01 . [DOI] [PubMed] [Google Scholar]
  • 34.Krarup T, Holm LM, la Cour M, Kjaerbo H. Endothelial cell loss and refractive predictability in femtosecond laser-assisted cataract surgery compared with conventional cataract surgery. Acta ophthalmologica. 2014;92(7):617–22. Epub 2014/06/04. 10.1111/aos.12406 . [DOI] [PubMed] [Google Scholar]
  • 35.Lawless M, Bali SJ, Hodge C, Roberts TV, Chan C, Sutton G. Outcomes of femtosecond laser cataract surgery with a diffractive multifocal intraocular lens. Journal of refractive surgery (Thorofare, NJ: 1995). 2012;28(12):859–64. Epub 2012/12/13. 10.3928/1081597x-20121115-02 . [DOI] [PubMed] [Google Scholar]
  • 36.Mastropasqua L, Toto L, Mastropasqua A, Vecchiarino L, Mastropasqua R, Pedrotti E, et al. Femtosecond laser versus manual clear corneal incision in cataract surgery. Journal of refractive surgery (Thorofare, NJ: 1995). 2014;30(1):27–33. Epub 2014/05/28. . [DOI] [PubMed] [Google Scholar]
  • 37.Mastropasqua L, Toto L, Mattei PA, Vecchiarino L, Mastropasqua A, Navarra R, et al. Optical coherence tomography and 3-dimensional confocal structured imaging system-guided femtosecond laser capsulotomy versus manual continuous curvilinear capsulorhexis. Journal of cataract and refractive surgery. 2014;40(12):2035–43. Epub 2014/12/03. 10.1016/j.jcrs.2014.05.032 . [DOI] [PubMed] [Google Scholar]
  • 38.Nagy ZZ, Dunai A, Kranitz K, Takacs AI, Sandor GL, Hecz R, et al. Evaluation of femtosecond laser-assisted and manual clear corneal incisions and their effect on surgically induced astigmatism and higher-order aberrations. Journal of refractive surgery (Thorofare, NJ: 1995). 2014;30(8):522–5. Epub 2014/10/18. 10.3928/1081597x-20140711-04 . [DOI] [PubMed] [Google Scholar]
  • 39.Nagy ZZ, Ecsedy M, Kovacs I, Takacs A, Tatrai E, Somfai GM, et al. Macular morphology assessed by optical coherence tomography image segmentation after femtosecond laser-assisted and standard cataract surgery. Journal of cataract and refractive surgery. 2012;38(6):941–6. Epub 2012/05/26. 10.1016/j.jcrs.2012.02.031 . [DOI] [PubMed] [Google Scholar]
  • 40.Nagy ZZ, Kranitz K, Takacs AI, Mihaltz K, Kovacs I, Knorz MC. Comparison of intraocular lens decentration parameters after femtosecond and manual capsulotomies. Journal of refractive surgery (Thorofare, NJ: 1995). 2011;27(8):564–9. Epub 2011/06/22. 10.3928/1081597x-20110607-01 . [DOI] [PubMed] [Google Scholar]
  • 41.Packer M, Solomon JD. Impact of crystalline lens opacification on effective phacoemulsification time in femtosecond laser-assisted cataract surgery. American journal of ophthalmology. 2014;157(6):1323–4. Epub 2014/06/03. 10.1016/j.ajo.2014.02.025 . [DOI] [PubMed] [Google Scholar]
  • 42.Reddy KP, Kandulla J, Auffarth GU. Effectiveness and safety of femtosecond laser-assisted lens fragmentation and anterior capsulotomy versus the manual technique in cataract surgery. Journal of cataract and refractive surgery. 2013;39(9):1297–306. Epub 2013/08/31. 10.1016/j.jcrs.2013.05.035 . [DOI] [PubMed] [Google Scholar]
  • 43.Schargus M, Suckert N, Schultz T, Kakkassery V, Dick HB. Femtosecond laser-assisted cataract surgery without OVD: a prospective intraindividual comparison. Journal of refractive surgery (Thorofare, NJ: 1995). 2015;31(3):146–52. Epub 2015/03/10. 10.3928/1081597x-20150220-01 . [DOI] [PubMed] [Google Scholar]
  • 44.Schultz T, Joachim SC, Tischoff I, Dick HB. Histologic evaluation of in vivo femtosecond laser-generated capsulotomies reveals a potential cause for radial capsular tears. European journal of ophthalmology. 2015;25(2):112–8. Epub 2014/08/07. 10.5301/ejo.5000484 . [DOI] [PubMed] [Google Scholar]
  • 45.Takacs AI, Kovacs I, Mihaltz K, Filkorn T, Knorz MC, Nagy ZZ. Central corneal volume and endothelial cell count following femtosecond laser-assisted refractive cataract surgery compared to conventional phacoemulsification. Journal of refractive surgery (Thorofare, NJ: 1995). 2012;28(6):387–91. Epub 2012/05/17. 10.3928/1081597x-20120508-02 . [DOI] [PubMed] [Google Scholar]
  • 46.Crema AS, Walsh A, Yamane Y, Nose W. Comparative study of coaxial phacoemulsification and microincision cataract surgery. One-year follow-up. Journal of cataract and refractive surgery. 2007;33(6):1014–8. 10.1016/j.jcrs.2007.02.035 . [DOI] [PubMed] [Google Scholar]
  • 47.Zetterstrom C, Laurell CG. Comparison of endothelial cell loss and phacoemulsification energy during endocapsular phacoemulsification surgery. Journal of cataract and refractive surgery. 1995;21(1):55–8. . [DOI] [PubMed] [Google Scholar]
  • 48.Hayashi K, Nakao F, Hayashi F. Corneal endothelial cell loss following phacoemulsification using the Small-Port Phaco. Ophthalmic surgery. 1994;25(8):510–3. . [PubMed] [Google Scholar]
  • 49.Dick HB, Kohnen T, Jacobi FK, Jacobi KW. Long-term endothelial cell loss following phacoemulsification through a temporal clear corneal incision. Journal of cataract and refractive surgery. 1996;22(1):63–71. . [DOI] [PubMed] [Google Scholar]
  • 50.Glasser DB. Is the Femtosecond Laser Worth It? American journal of ophthalmology. 2012;154(2):217–8. 10.1016/j.ajo.2012.03.024 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

S1 PRISMA Checklist. PRISMA Checklist.

(DOC)

S1 Table. Quality assessment of cohort studies on the Newcastle-Ottawa Scale.

(PDF)

S1 Fig. Risk of bias graph.

Review authors' judgments about each methodological quality item presented as percentages across included RCTs.

(TIF)

S2 Fig. Forest plot comparison of SIA after treatment with FLACS and CPS.

(TIF)

S3 Fig. Forest plot comparison of EPT after treatment with FLACS and CPS.

(TIF)

S4 Fig. Forest plot comparison of phacoemulsification power after treatment with FLACS and CPS.

(TIF)

S5 Fig. Forest plot comparison of circularity of capsulorhexis after treatment with FLACS and CPS.

(TIF)

Data Availability Statement

All relevant data are within the paper and its Supporting Information files.


Articles from PLoS ONE are provided here courtesy of PLOS

RESOURCES