Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 1964 Nov;17(6):644–648. doi: 10.1136/jcp.17.6.644

An automated method for serum magnesium estimation

D N Whitmore 1, D I K Evans 1
PMCID: PMC480847  PMID: 14227433

Abstract

An automated method for magnesium determination in serum is described using conventional AutoAnalyser equipment. The method gives results comparable with those obtained by the flame photometer. The method may prove particularly useful with subnormal serum magnesium levels.

Full text

PDF
644

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. ALCOCK N., MACINTYRE I., RADDE I. The determination of magnesium in biological fluids and tissues by flame spectrophotometry. J Clin Pathol. 1960 Nov;13:506–510. doi: 10.1136/jcp.13.6.506. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. BOOTH C. C., BABOURIS N., HANNA S., MACINTYRE I. Incidence of hypomagnesaemia in intestinal malabsorption. Br Med J. 1963 Jul 20;2(5350):141–144. doi: 10.1136/bmj.2.5350.141. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. CARR C. W., WOODS K. R. Studies on the binding of small ions in protein solutions with the use of membrane electrodes. V. The binding of magnesium ions in solutions of various proteins. Arch Biochem Biophys. 1955 Mar;55(1):1–8. doi: 10.1016/0003-9861(55)90536-1. [DOI] [PubMed] [Google Scholar]
  4. COPELAND B. E., SUNDERMAN F. W. Studies in serum electrolytes. XVIII. The magnesium-binding property of the serum proteins. J Biol Chem. 1952 May;197(1):331–341. [PubMed] [Google Scholar]
  5. HANNA S. Plasma magnesium in health and disease. J Clin Pathol. 1961 Jul;14:410–414. doi: 10.1136/jcp.14.4.410. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. HILL J. B. An automated fluorometric method for the determination of serum magnesium. Ann N Y Acad Sci. 1962 Oct 31;102:108–117. doi: 10.1111/j.1749-6632.1962.tb13630.x. [DOI] [PubMed] [Google Scholar]
  7. HILL J. B., KESSLER G. An automated determination of glucose utilizing a glucose oxidase-peroxidase system. J Lab Clin Med. 1961 Jun;57:970–980. [PubMed] [Google Scholar]
  8. IRVING E. A., WATTS P. S. Estimation of calcium and magnesium in blood serum by the cathode-ray polarograph. Biochem J. 1961 May;79:429–432. doi: 10.1042/bj0790429. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Irons L. I., Perkins D. J. Studies on the interaction of magnesium, calcium and strontium ions with native and chemically modified human serum albumin. Biochem J. 1962 Jul;84(1):152–156. doi: 10.1042/bj0840152. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. PRASAD A. S., FLINK E. B., McCOLLISTER R. Ultrafiltration studies on serum magnesium in normal and diseased states. J Lab Clin Med. 1961 Oct;58:531–541. [PubMed] [Google Scholar]
  11. SCHACHTER D. The fluorometric estimation of magnesium in serum and in urine. J Lab Clin Med. 1959 Nov;54:763–768. [PubMed] [Google Scholar]
  12. SILVERMAN S. H., GARDNER L. I. Ultrafiltration studies on serum magnesium. N Engl J Med. 1954 Jun 3;250(22):938–941. doi: 10.1056/NEJM195406032502204. [DOI] [PubMed] [Google Scholar]
  13. Soffer L. J., Dantes D. A., Grossman E. B., Sobotka H., Jacobs M. D. ULTRAFILTRABLE MAGNESIUM IN HYPERTHYROIDISM. J Clin Invest. 1939 Sep;18(5):597–601. doi: 10.1172/JCI101073. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. WIEME R. J., VAN RAEPENBUSCH F. R. Automatic determination of calcium in blood and urine using Corinth Ca. Clin Chim Acta. 1962 Nov;7:883–887. doi: 10.1016/0009-8981(62)90077-3. [DOI] [PubMed] [Google Scholar]
  15. WILKINSON R. H. A micro-method for serum calcium and serum magnesium. J Clin Pathol. 1957 May;10(2):126–135. doi: 10.1136/jcp.10.2.126. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group

RESOURCES