Abstract
Ninety-four patients with patent ductus arteriosus, whose ages ranged from 28 weeks gestation to 8 years, were assessed by suprasternal cross-sectional echocardiography. A further group of 37 cases without a patent ductus arteriosus were assessed by the same technique. The appearances of the ductus via this approach varied according to the ventriculoarterial connections. Reliable assessment of patency was possibly in 87 cases. In seven cases where the ductal lumen was less than 2 mm in size, a false negative diagnosis was made. In the 37 patients without a patent ductus arteriosus, no false positive diagnoses were made. Suprasternal cross-sectional echocardiography enables a reliable assessment of ductal patency, provided the lumen falls within the range of lateral resolution of the equipment being used.
Full text
PDF









Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Gittenberger-de Groot A. C. Persistent ductus arteriosus: most probably a primary congenital malformation. Br Heart J. 1977 Jun;39(6):610–618. doi: 10.1136/hrt.39.6.610. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sahn D. J., Allen H. D. Real-time cross-sectional echocardiographic imaging and measurement of the patent ductus arteriosus in infants and children. Circulation. 1978 Aug;58(2):343–354. doi: 10.1161/01.cir.58.2.343. [DOI] [PubMed] [Google Scholar]
- Sahn D. J., Vaucher Y., Williams D. E., Allen H. D., Goldberg S. J., Friedman W. F. Echocardiographic detection of large left to right shunts and cardiomyopathies in infants and children. Am J Cardiol. 1976 Jul;38(1):73–79. doi: 10.1016/0002-9149(76)90065-5. [DOI] [PubMed] [Google Scholar]
- Santos M. A., Moll J. N., Drumond C., Araujo W. B., Romao N., Reis N. B. Development of the ductus arteriosus in right ventricular outflow tract obstruction. Circulation. 1980 Oct;62(4):818–822. doi: 10.1161/01.cir.62.4.818. [DOI] [PubMed] [Google Scholar]
- Silverman N. H., Lewis A. B., Heymann M. A., Rudolph A. M. Echocardiographic assessment of ductus arteriosus shunt in premature infants. Circulation. 1974 Oct;50(4):821–825. doi: 10.1161/01.cir.50.4.821. [DOI] [PubMed] [Google Scholar]
- Stevenson J. G., Kawabori I., Guntheroth W. G. Noninvasive detection of pulmonary hypertension in patent ductus arteriosus by pulsed Doppler echocardiography. Circulation. 1979 Aug;60(2):355–359. doi: 10.1161/01.cir.60.2.355. [DOI] [PubMed] [Google Scholar]