Abstract
Between June 1978 and January 1982, 115 patients underwent 122 subclavian artery-pulmonary artery shunts using polytetrafluoroethylene (PTFE Impra) grafts. Forty-six of the patients had a ductus dependent pulmonary circulation, the patency of which was maintained by an infusion of prostaglandin E2 in 29 cases. There were nine hospital deaths, four of which were related to shunt failure. Five patients underwent a second shunt procedure within one week of the first. There were two cases of late graft occlusion. Twelve shunts were considered to have failed. The actuarial estimate of shunt patency was 90% (+/- 3%) at two years for all patients and 74% (+/- 10%) for neonates. There was no statistically significant difference in two year shunt patency between 4 mm grafts (88 +/- 5%) and 6 mm grafts (96 +/- 3%). The modified Blalock shunt using a PTFE graft is an effective pulmonary-systemic shunt with a good short term patency.
Full text
PDF




Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Browdie D. A., Norberg W., Agnew R., Altenburg B., Ignacio R., Hamilton C. The use of prostaglandin E1 and Blalock-Taussig shunts in neonates with cyanotic congenital heart disease. Ann Thorac Surg. 1979 Jun;27(6):508–513. doi: 10.1016/s0003-4975(10)63359-0. [DOI] [PubMed] [Google Scholar]
- Currarino G., Engle M. A. The effects of ligation of the subclavian artery on the bones and soft tissues of the arms. J Pediatr. 1965 Nov;67(5):808–811. doi: 10.1016/s0022-3476(65)80370-5. [DOI] [PubMed] [Google Scholar]
- Donahoo J. S., Roland J. M., Kan J., Gardner T. J., Kidd B. S. Prostaglandin E1 as an adjunct to emergency cardiac operation in neonates. J Thorac Cardiovasc Surg. 1981 Feb;81(2):227–231. [PubMed] [Google Scholar]
- Elliott R. B., Starling M. B., Neutze J. M. Medical manipulation of the ductus arteriosus. Lancet. 1975 Jan 18;1(7899):140–142. doi: 10.1016/s0140-6736(75)91432-4. [DOI] [PubMed] [Google Scholar]
- Gazzaniga A. B., Lamberti J. J., Siewers R. D., Sperling D. R., Dietrick W. R., Arcilla R. A., Replogle R. L. Arterial prosthesis of microporous expanded polytetrafluoroethylene for construction of aorta-pulmonary shunts. J Thorac Cardiovasc Surg. 1976 Sep;72(3):357–363. [PubMed] [Google Scholar]
- HARRIS A. M., SEGEL N., BISHOP J. M. BLALOCK-TAUSSIG ANASTOMOSIS FOR TETRALOGY OF FALLOT. A TEN-TO-FIFTEEN YEAR FOLLOW-UP. Br Heart J. 1964 Mar;26:266–267. doi: 10.1136/hrt.26.2.266. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jennings R. B., Jr, Innes B. J., Brickman R. D. Use of microporous expanded polytetrafluoroethylene grafts for aorta-pulmonary shunts in infants with complex cyanotic heart disease. A report of seven cases. J Thorac Cardiovasc Surg. 1978 Oct;76(4):489–494. [PubMed] [Google Scholar]
- KLINNER W., PASINI M., SCHAUDIG A. [Anastomosis between systemic and pulmonary arteries with the aid of plastic prostheses in cyanotic heart diseases]. Thoraxchirurgie. 1962 Jul;10:68–75. doi: 10.1055/s-0028-1096482. [DOI] [PubMed] [Google Scholar]
- Kirklin J. W., Blackstone E. H., Pacifico A. D., Brown R. N., Bargeron L. M., Jr Routine primary repair vs two-stage repair of tetralogy of Fallot. Circulation. 1979 Aug;60(2):373–386. doi: 10.1161/01.cir.60.2.373. [DOI] [PubMed] [Google Scholar]
- Miyamoto K., Zavanella C., Lewin A. N., Subramanian S. Aorta-pulmonary artery shunts with expanded polytetrafluoroethylene (PTFE) tube. Ann Thorac Surg. 1979 May;27(5):413–417. doi: 10.1016/s0003-4975(10)63337-1. [DOI] [PubMed] [Google Scholar]
- Oblath R. W., Buckley F. O., Jr, Green R. M., Schwartz S. I., DeWeese J. A. Prevention of platelet aggregation and adherence to prosthetic vascular grafts by aspirin and dipyridamole. Surgery. 1978 Jul;84(1):37–44. [PubMed] [Google Scholar]
- Stephenson L. W., Friedman S., Edmunds L. H., Jr Staged surgical management of tetralogy of Fallot in infants. Circulation. 1978 Nov;58(5):837–841. doi: 10.1161/01.cir.58.5.837. [DOI] [PubMed] [Google Scholar]
- de Leval M. R., McKay R., Jones M., Stark J., Macartney F. J. Modified Blalock-Taussig shunt. Use of subclavian artery orifice as flow regulator in prosthetic systemic-pulmonary artery shunts. J Thorac Cardiovasc Surg. 1981 Jan;81(1):112–119. [PubMed] [Google Scholar]