Skip to main content
European Journal of Dentistry logoLink to European Journal of Dentistry
. 2016 Apr-Jun;10(2):259–263. doi: 10.4103/1305-7456.178295

Dimensional stability of two solder index materials

Amir Ali Reza Khaledi 1, Soheil Pardis 2, Negar Pourhatami 3, Zahra Hashemi Ardakani 1,
PMCID: PMC4813447  PMID: 27095908

Abstract

Objectives:

This study aimed to compare the dimensional accuracy of two indexing materials, an acrylic resin (GC pattern resin) and a castable composite (Bredent). The effect of time lapse until investment was also investigated.

Materials and Methods:

Two standardized brass dies 15 mm apart were prepared and then 20 identical coping-bar assemblies were designed and fabricated by a rapid prototyping device. Each bar was sectioned at the center, and indices were fabricated from an acrylic resin or castable composite (n = 10 per group). The distances between the reference points were measured with a digital microscope at ×80 magnifications at 15 min, 60 min, and 24 h after indexing. Data were statically analyzed using repeated-measure ANOVA (α = 0.05).

Results:

The distance between the reference points without the coping being joined was considered as the baseline measurement (control group). The mean distance was 19.30 ± 0.04 mm between the reference points where the copings were not joined. When indexed with acrylic resin, the mean ± standard deviation (SD) dimensions were 19.27 ± 0.087 mm (15 min), 19.25 ± 0.09 mm (60 min), and 18.98 ± 0.1 mm (24 h). The mean ± SD dimensions for composite were 19.29 ± 0.087 mm (15 min), 19.28 ± 0.08 mm (60 min), and 19.26 ± 0.08 mm (24 h). All tested groups showed significant differences compared to the control group except when it was indexed with composite and where the distances were measured after 15 and 60 min (P > 0.05).

Conclusions:

The most accurate indexed-assemblies belonged to castable composite at 15 and 60 min.

Keywords: Acrylic resin, composite, dimensional stability, indexing, solder

INTRODUCTION

One of the critical prognostic factors is the accurate fit of a fixed partial denture (FPD) framework.[1,2] An inadequate fit can result from both laboratory and clinical causes. Slight instabilities in the fit of frameworks are common, especially when magnification is used as an aid in evaluation.[3]

Researchers have attempted more accurately to determine the accuracy of this fit by using different measurement methods such as photogrammetry, laser digitizers, and coordinate measurement devices.[4,5,6] Framework fit has been determined for different methods of fabrication including cast and machined frameworks. Although suggestions state that machined and cast frameworks have a comparable fit, casting is a common technique for fabricating frameworks.[6,7] Thus, sectioning and soldering methods are frequently used to improve the fit of a framework.[8] The segmental/solder assembly procedure is as follows: Casting the segments of the full-arch framework, clinically evaluating the fit of each segment, incrementally indexing, and then soldering these segments before progressing to full-arch fit evaluation. This protocol provides an alternate fabrication procedure to casting as a single piece.[9]

Relating or indexing materials are used to connect the individual parts of a sectioned casting intraorally before the casting is transferred to the laboratory for investing and soldering.[3,9]

Although several researchers[10,11,12] proposed plaster or stone indices for investment soldering, others[13,14] recommended sticky wax. Patterson[15] described a technique that used self-cure acrylic resin. Another guideline[16] suggested two self-cure acrylic resins - Duralay or Caulk's “Orthodontic” resin.

Harper and Nicholls[17] evaluated the three-dimensional discrepancy caused by different indexing materials. They specified that zinc oxide eugenol bite registration material was the most accurate indexing technique, followed by plaster and Duralay resin, and sticky wax as the least precise. Moon et al.[18] reported the least discrepancy with a plaster nonremoval technique followed by Duralay resin. These researchers[17,18] stated that assembled units should be invested as quickly as possible, and that thin resin indices were more accurate than thick resin indices. Others[3,19,20,21,22] determined the contraction of indexing resins and reported that the accuracy of resin indices decreased significantly with time.

Although there is information on the adverse effects of increased time lapse between indexing with acrylic resins and investment of an assembly of components for FPD,[3] similar data are lacking for composite materials and its comparison to resin index. There seems to be a need to assess the dimensional accuracy of solder index materials and to weigh the possible clinical importance of the polymerization effect. Therefore, the purpose of this study was to compare the relative dimensional accuracy of two commonly used materials, an acrylic resin, and a castable composite, for indexing prostheses assemblies and the effect of time lapse until investment for soldering.

MATERIALS AND METHODS

For this experimental study, two machined brass dies were designed and prepared (CNC 350, Arix Co., Tainan Hesin, Taiwan) to simulate a full coverage metal crown preparation with a chamfer margin around the entire circumference. Preparations were standardized at a height of 5.5 mm, width of 6 mm at the margin, a convergence angle of 6°, 0.7 mm chamfer width, chamfer radius of 2 mm, and anti-rotation surface. Dies were secured 15 mm apart to represent the distance for a three-unit FPD in a cast made by the stone of Type IV (whipmix GmbH, Dortmund, Germany).

A laser scanner (3shape D 810; 3shape, Copenhagen K, Denmark) was used to digitize the dies. The data were transmitted to a software program (3shape CAD design software; 3shape, Copenhagen K, Denmark). Two copings were designed with a bar. In addition, parallel cylindrical rods with discrete pinpoint indentations at the centers of rods were generated on the occlusal surfaces of the copings. Next, 20 identical wax patterns were produced by a rapid prototyping device (Solidscape, D76+, Solidscape Inc., Merrimack, NH, USA).

All wax patterns were invested and casted with nickel-chromium (Ni-Cr) alloy (4 All, Ivoclar-Vivadent, Schann, Germany). The internal surfaces of the copings were examined by binocular loupes (HEINE HR-C 2.5 X, HEINE, Herrsching, Germany) and disclosing pastes (FiT checker; GC Corporation) to remove nodules and pressure spots. The copings were subsequently placed on the master dies, and then for baseline measurement (control), the distance between two indentations was measured and recorded by a digital microscope (AM 413 Fit Dino-Lite Pro; Dino-light, Taipei, Taiwan) mounted on a desktop stand. The digital microscope was connected to a computer and photographs were taken at × 80 magnification. Then, the bars were sectioned carefully at the center by a disk (Keystone GmbH, Werner-von-Siemens, Germany) which produced a gap distance of 0.5 mm. A new disk was used for each individual bar.

Half of the specimens (n = 10) were indexed by a castable composite (Bredent, America Inc.) and the others by acrylic resin (GC Pattern, America, Inc.). The pattern resin was prepared by adding the powder to the monomer according to the manufacturer's recommendation, and the composite resin index was set with a visible-light source (600 mW/cm2, Coltolux 50, Swiss). The coping-bar assemblies were seated on the abutments with firm finger pressure until the indices were polymerized. Each specimen in each of the two groups (n = 10 per each group) was subjected to measurement for 3 times (at 1 min, then at 15 min, and finally after 24 h). In other words on the same specimen of the two tested groups for each period, 10 measurements were performed. Afterward, the mean value of ten measurements for each period was calculated. The same microscope and software were utilized to measure the distances between indentations at 15, 60 min, and 24 h after indexing.

Statistical analysis

Data were analyzed by SPSS 18 software (SPSS Inc., Chicago, IL, USA). Several-sample repeated measure ANOVA (RM-ANOVA) was applied to assess the effects of the material on the dimensional stability over time (α = 0.05).

RESULTS

RM-ANOVA showed a significant interaction effect between materials and time (P < 0.001). Therefore, sub-group analysis was performed. In this context, two materials were compared by Student's t-test at each time point. One-sample RM-ANOVA/Sidak test was used for within-material analysis.

The mean distance between indentations as a reference point was 19.30 ± 0.04 mm before the bar sectioning (baseline measurement). Less distance was caused by both composite and acrylic resin materials than measurements which lacked indexing materials. All tested groups had significant differences in comparison with the control group except when it was indexed with composite and where the distances were measured after 15 and 60 min.

According to Table 1, there was a significantly greater mean dimensional stability of acrylic resin specimens after 15 and 60 min than the specimens after 24 h (P < 0.001). However, there was no significant difference between 15 and 60 min (P = 0.073).

Table 1.

Mean±standard deviation distance (mm) between tested materials

graphic file with name EJD-10-259-g001.jpg

In composite specimens, there was a significantly greater mean dimensional stability after 15 min compared with 24 h (P = 0.002). Likewise, this difference was significant after 60 min and 24 h (P = 0.003). However, the mean dimensional stability after 15 and 60 min did not show any significant differences (P = 0.13).

The mean dimensional stability of acrylic resin and composite did not exhibit a significant difference after 15 min (P = 0.49). Similarly, this difference between acrylic resin and composite was not significant after 60 min (P = 0.36). However, the mean dimensional stability of composite resin was greater than acrylic resin (P < 0.001), after 24 h. Figure 1 demonstrates mean profiles of distances between reference points of the tested groups.

Figure 1.

Figure 1

Mean profiles of distances between reference points of the tested groups

DISCUSSION

Few studies have compared the accuracy of composite materials with acrylic resins and the time lapse between indexing with composite and investing. Thus, this study evaluated the relative accuracy of a castable composite and a pattern resin used to make soldering indexes for FPD or for implant-supported prostheses at 3 time periods. The results showed that soldering index made with castable composite was more accurate than pattern resin. However, castable composite, as an indexing material, should be invested preferably within 60 min.

Mojon et al.[20] assessed standard mixes of two self-cure resins and observed a 7.9% ±1.4% polymerization contraction for Duralay resin and a 6.5% ±0.5% contraction for Palavit G at 24 h. Another study reported that a 3 mm thick Duralay soldering index was dramatically more accurate than a 6 mm thick index.[18] In agreement with our study, Moon et al.[18] suggested that FPD units slated for soldering and indexed with acrylic resin material should be invested as soon as possible, preferably, within 1 h. Dixon et al.[21] concluded that the mean linear difference for 10 samples over a 24-h time interval was 0.373 mm. They also attributed such errors to polymerization contraction and possible dimensional change after polymerization that was related to stress release in the polymerized resin.

Ness et al.[22] determined that self-cure acrylic resin (Duralay) was less accurate in pattern fabrication than methyl methacrylate or ethyl methacrylate self-cure acrylic resins.

Cho and Chee[19] compared the dimensional accuracy and also the setting time of two self-cure resins (Duralay and GC pattern) and one light polymerizing resin (Unifast) used to connect castings for soldering. They obtained measurements immediately after polymerization of the materials. Although Duralay showed acceptable clinical results, one disadvantage was a prolonged setting time (7 min) compared to GC pattern (3 min). Therefore, GC pattern was used as indexing material in our study. In their study, the authors did not evaluate the dimensional accuracy of the tested indexing materials at other periods. However, in agreement with the current study, they found that all indexing materials immediately after polymerization resulted in a contraction of the distance between the resin-connected castings compared with the true distance. This difference was attributed to polymerization contraction of the indexing materials.[19]

In some previous studies, a gap distance of approximately 0.24 mm was considered for indexing and soldering of frameworks. Therefore, the resulted dimensional changes were considered too small to have a clinical significance.[3,18,19,21] These insignificant amounts of dimensional changes could be attributed to the small gap distances prepared in the laboratory (0.24 mm). However, due to the discrepancies in the framework's fit, their sectioning, and indexing protocol are occasionally mandatory in the clinic. Solder gap distances that range from 0.1 to 0.76 mm have been advocated for use,[21] because in most clinical situations, usually very narrow gap distances cannot be achieved easily. It is difficult to generate delicate gap distances in the clinic due to the number of insertions and removals of the disk along with vibration by the operator's hand and the disks. Therefore, a gap of 0.5 mm was chosen for this study. Further research is recommended to determine the clinical significance of this amount of gap distance.

The results of our study indicated that it is more efficient to select visible-light cure composites to index casting for solder because of the decreased setting time and dimensional accuracy of composite after 15, 60 min, and 24 h compared to acrylic resin. Faster setting time and dimensional stability during the indexing procedure could improve efficiency and productivity.

CONCLUSIONS

Within the limitation of the present study it could be concluded that:

  • Castable composite-indexed assemblies were more accurate in all tested periods of time compared to pattern acrylic resin

  • Castable composite as an indexing material should be invested preferably within 60 min

  • Because of the rapid setting time, it appeared more efficient to select composite as an indexing material.

Financial support and sponsorship

The Vice-Chancellor of Shiraz University of Medical Sciences for supporting this research (Grant#7015).

Conflicts of interest

There are no conflicts of interest

Acknowledgment

The authors would like to express their appreciation to the Vice-Chancellor of Shiraz University of Medical Sciences for supporting this research (Grant#7015). This article was based on the thesis by Dr. Pour Hatami. The authors also thank Dr. Vosoghi of the Dental Research Development Center of the School of Dentistry for statistical analysis.

REFERENCES

  • 1.Patil A, Singh K, Sahoo S, Suvarna S, Kumar P, Singh A. Comparative assessment of marginal accuracy of grade II titanium and Ni-Cr alloy before and after ceramic firing: An in vitro study. Eur J Dent. 2013;7:272–7. doi: 10.4103/1305-7456.115409. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Demir N, Ozturk AN, Malkoc MA. Evaluation of the marginal fit of full ceramic crowns by the microcomputed tomography (micro-CT) technique. Eur J Dent. 2014;8:437–44. doi: 10.4103/1305-7456.143612. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.McDonnell T, Houston F, Byrne D, Gorman C, Claffey N. The effect of time lapse on the accuracy of two acrylic resins used to assemble an implant framework for soldering. J Prosthet Dent. 2004;91:538–40. doi: 10.1016/s0022-3913(02)52728-1. [DOI] [PubMed] [Google Scholar]
  • 4.Jemt T, Rubenstein JE, Carlsson L, Lang BR. Measuring fit at the implant prosthodontic interface. J Prosthet Dent. 1996;75:314–25. doi: 10.1016/s0022-3913(96)90491-6. [DOI] [PubMed] [Google Scholar]
  • 5.Tan KB, Rubenstein JE, Nicholls JI, Yuodelis RA. Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. Int J Prosthodont. 1993;6:346–63. [PubMed] [Google Scholar]
  • 6.Riedy SJ, Lang BR, Lang BE. Fit of implant frameworks fabricated by different techniques. J Prosthet Dent. 1997;78:596–604. doi: 10.1016/s0022-3913(97)70011-8. [DOI] [PubMed] [Google Scholar]
  • 7.Jemt T, Bäck T, Petersson A. Photogrammetry – An alternative to conventional impressions in implant dentistry. A clinical pilot study? Int J Prosthodont. 1999;12:363–8. [PubMed] [Google Scholar]
  • 8.Wee AG, Aquilino SA, Schneider RL. Strategies to achieve fit in implant prosthodontics: A review of the literature. Int J Prosthodont. 1999;12:167–78. [PubMed] [Google Scholar]
  • 9.Rubenstein JE, Lowry MB. A comparison of two solder registration materials: A three-dimensional analysis. J Prosthet Dent. 2006;95:379–91. doi: 10.1016/j.prosdent.2006.02.013. [DOI] [PubMed] [Google Scholar]
  • 10.Hollenback GM, Smith DD, Shell JS. The accuracy of dental appliances assembled by soldering. II. J Calif Dent Assoc. 1966;42:124–8. [PubMed] [Google Scholar]
  • 11.Stackhouse JA., Jr Assembly of dental units by soldering. J Prosthet Dent. 1967;18:131–9. doi: 10.1016/s0022-3913(67)80055-6. [DOI] [PubMed] [Google Scholar]
  • 12.Fusayama T, Wakumoto S, Hosoda H. Accuracy of fixed partial dentures made by various soldering techniques and one-piece casting. J Prosthet Dent. 1964;14:334–42. [Google Scholar]
  • 13.Ryge G. Dental soldering procedures. Dent Clin North Am. 1958;2:747–57. [Google Scholar]
  • 14.Steinman R. Warpage produced by soldering with dental solders and gold alloys. J Prosthet Dent. 1954;4:384–95. [Google Scholar]
  • 15.Patterson JC., Jr A technique for accurate soldering. J Prosthet Dent. 1972;28:552–6. doi: 10.1016/0022-3913(72)90068-6. [DOI] [PubMed] [Google Scholar]
  • 16.Jelenko JF & Co. Crown and Bridge Construction: A Handbook of Dental Laboratory Procedures. 5th ed. New York: Jelenko JF and Co; 1963. [Google Scholar]
  • 17.Harper RJ, Nicholls JI. Distortions in indexing methods and investing media for soldering and remount procedures. J Prosthet Dent. 1979;42:172–9. doi: 10.1016/0022-3913(79)90169-0. [DOI] [PubMed] [Google Scholar]
  • 18.Moon PC, Eshleman JR, Douglas HB, Garrett SG. Comparison of accuracy of soldering indices for fixed prostheses. J Prosthet Dent. 1978;40:35–8. doi: 10.1016/0022-3913(78)90155-5. [DOI] [PubMed] [Google Scholar]
  • 19.Cho GC, Chee WW. Efficient soldering index materials for fixed partial dentures and implant substructures. J Prosthet Dent. 1995;73:424–7. doi: 10.1016/s0022-3913(05)80069-1. [DOI] [PubMed] [Google Scholar]
  • 20.Mojon P, Oberholzer JP, Meyer JM, Belser UC. Polymerization shrinkage of index and pattern acrylic resins. J Prosthet Dent. 1990;64:684–8. doi: 10.1016/0022-3913(90)90296-o. [DOI] [PubMed] [Google Scholar]
  • 21.Dixon DL, Breeding LC, Lindquist TJ. Linear dimensional variability and tensile strengths of three solder index materials. J Prosthet Dent. 1992;67:726–9. doi: 10.1016/0022-3913(92)90180-i. [DOI] [PubMed] [Google Scholar]
  • 22.Ness EM, Nicholls JI, Rubenstein JE, Smith DE. Accuracy of the acrylic resin pattern for the implant-retained prosthesis. Int J Prosthodont. 1992;5:542–9. [PubMed] [Google Scholar]

Articles from European Journal of Dentistry are provided here courtesy of Dental Investigations Society

RESOURCES