Abstract
Twenty five patients who had undergone conventional coronary arteriography and left ventriculography for suspected coronary artery disease had left ventriculography performed by digital subtraction angiography as outpatients; there were no complications requiring admission to hospital. A catheter was introduced percutaneously and positioned in the superior vena cava; 40-50 ml of contrast medium was injected at 16-18 ml/s. Left ventriculograms were recorded in the 30 degrees right anterior oblique projection. Diagnostic images were recorded in each case. Left ventricular wall movement was assessed as normal in nine patients, globally hypokinetic in 10, and aneurysmal in six. In each case there was agreement between the two methods. Ejection fraction varied between 17% and 78%. It is concluded that digital subtraction angiography provides a reliable assessment of overall left ventricular function and distinguishes between those patients with a potentially resectable lesion and those with global impairment of function.
Full text
PDF




Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Dodge H. T. Determination of left ventricular volume and mass. Radiol Clin North Am. 1971 Dec;9(3):459–467. [PubMed] [Google Scholar]
- Engels P. H., Ludwig J. W., Verhoeven L. A. Left ventricle evaluation by digital video subtraction angiocardiography. Radiology. 1982 Aug;144(3):471–474. doi: 10.1148/radiology.144.3.7048415. [DOI] [PubMed] [Google Scholar]
- Higgins C. B., Norris S. L., Gerber K. H., Slutsky R. A., Ashburn W. L., Baily N. Quantitation of left ventricular dimensions and function by digital video subtraction angiography. Radiology. 1982 Aug;144(3):461–469. doi: 10.1148/radiology.144.3.7048414. [DOI] [PubMed] [Google Scholar]
- Kruger R. A., Mistretta C. A., Houk T. L., Riederer S. J., Shaw C. G., Goodsitt M. M., Crummy A. B., Zwiebel W., Lancaster J. C., Rowe G. G. Computerized fluoroscopy in real time for noninvasive visualization of the cardiovascular system. Preliminary studies. Radiology. 1979 Jan;130(1):49–57. doi: 10.1148/130.1.49. [DOI] [PubMed] [Google Scholar]
- Meaney T. F., Weinstein M. A., Buonocore E., Pavlicek W., Borkowski G. P., Gallagher J. H., Sufka B., MacIntyre W. J. Digital subtraction angiography of the human cardiovascular system. AJR Am J Roentgenol. 1980 Dec;135(6):1153–1160. doi: 10.2214/ajr.135.6.1153. [DOI] [PubMed] [Google Scholar]
- Mistretta C. A., Crummy A. B., Strother C. M. Digital angiography: a perspective. Radiology. 1981 May;139(2):273–276. doi: 10.1148/radiology.139.2.7012918. [DOI] [PubMed] [Google Scholar]
- Nichols A. B., Martin E. C., Fles T. P., Stugensky K. M., Balancio L. A., Casarella W. J., Weiss M. B. Validation of the angiographic accuracy of digital left ventriculography. Am J Cardiol. 1983 Jan 1;51(1):224–230. doi: 10.1016/s0002-9149(83)80040-x. [DOI] [PubMed] [Google Scholar]
- Ovitt T. W. Intravenous angiography utilizing digital video subtraction techniques. Am J Cardiol. 1982 Apr 1;49(5):1365–1367. doi: 10.1016/0002-9149(82)90073-x. [DOI] [PubMed] [Google Scholar]
- Sasayama S., Nonogi H., Kawai C., Fujita M., Eiho S., Kuwahara M. Automated method for left ventricular volume measurement by cineventriculography with minimal doses of contrast medium. Am J Cardiol. 1981 Oct;48(4):746–753. doi: 10.1016/0002-9149(81)90154-5. [DOI] [PubMed] [Google Scholar]
- Tobis J. M., Nalcioglu O., Johnston W. D., Seibert A., Roeck W., Iseri L. T., Elkayam U., Henry W. L. Correlation of 10-milliliter digital subtraction ventriculograms compared with standard cineangiograms. Am Heart J. 1983 Jun;105(6):946–952. doi: 10.1016/0002-8703(83)90395-2. [DOI] [PubMed] [Google Scholar]

