Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1984 Mar;51(3):275–279. doi: 10.1136/hrt.51.3.275

Radionuclide measurement of left ventricular ejection fraction in infants and children.

E J Baker, S V Ellam, M N Maisey, M J Tynan
PMCID: PMC481498  PMID: 6696805

Abstract

The left ventricular ejection fraction was measured in 60 infants and children with congenital heart disease by both the equilibrium gated radionuclide technique and biplane left ventricular cineangiography. The median age of the patients studied was 2.25 years, and 17 were less than 1 year old. The correlation coefficient for the two sets of measurements was good and did not deteriorate in subgroups under 1 year old and with a large left to right shunt. In those infants with a right to left shunt the correlation was weak. Equilibrium gated radionuclide angiography is a valid and clinically valuable method of measuring left ventricular function in infants and children with congenital heart disease.

Full text

PDF
275

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Askenazi J., Ahnberg D. S., Korngold E., LaFarge C. G., Maltz D. L., Treves S. Quantitative radionuclide angiocardiography: detection and quantitation of left to right shunts. Am J Cardiol. 1976 Mar 4;37(3):382–387. doi: 10.1016/0002-9149(76)90287-3. [DOI] [PubMed] [Google Scholar]
  2. Berger H. J., Matthay R. A., Pytlik L. M., Gottschalk A., Zaret B. L. First-pass radionuclide assessment of right and left ventricular performance in patients with cardiac and pulmonary disease. Semin Nucl Med. 1979 Oct;9(4):275–295. doi: 10.1016/s0001-2998(79)80014-8. [DOI] [PubMed] [Google Scholar]
  3. Burow R. D., Strauss H. W., Singleton R., Pond M., Rehn T., Bailey I. K., Griffith L. C., Nickoloff E., Pitt B. Analysis of left ventricular function from multiple gated acquisition cardiac blood pool imaging. Comparison to contrast angiography. Circulation. 1977 Dec;56(6):1024–1028. doi: 10.1161/01.cir.56.6.1024. [DOI] [PubMed] [Google Scholar]
  4. Dodge H. T., Sandler H., Baxley W. A., Hawley R. R. Usefulness and limitations of radiographic methods for determining left ventricular volume. Am J Cardiol. 1966 Jul;18(1):10–24. doi: 10.1016/0002-9149(66)90191-3. [DOI] [PubMed] [Google Scholar]
  5. Folland E. D., Hamilton G. W., Larson S. M., Kennedy J. W., Williams D. L., Ritchie J. L. The radionuclide ejection fraction: a comparison of three radionuclide techniques with contrast angiography. J Nucl Med. 1977 Dec;18(12):1159–1166. [PubMed] [Google Scholar]
  6. Graham T. P., Jr, Jarmakani J. M., Canent R. V., Jr, Morrow M. N. Left heart volume estimation in infancy and childhood. Reevaluation of methodology and normal values. Circulation. 1971 Jun;43(6):895–904. doi: 10.1161/01.cir.43.6.895. [DOI] [PubMed] [Google Scholar]
  7. Hoffman J. I., Christianson R. Congenital heart disease in a cohort of 19,502 births with long-term follow-up. Am J Cardiol. 1978 Oct;42(4):641–647. doi: 10.1016/0002-9149(78)90635-5. [DOI] [PubMed] [Google Scholar]
  8. Kennedy J. W., Baxley W. A., Figley M. M., Dodge H. T., Blackmon J. R. Quantitative angiocardiography. I. The normal left ventricle in man. Circulation. 1966 Aug;34(2):272–278. doi: 10.1161/01.cir.34.2.272. [DOI] [PubMed] [Google Scholar]
  9. Maisey M. N., Brennand-Roper D. A., Wainwright R. J. Nuclear medicine in clinical cardiology. Br Med Bull. 1980 Sep;36(3):237–241. doi: 10.1093/oxfordjournals.bmb.a071647. [DOI] [PubMed] [Google Scholar]
  10. Parrish M. D., Graham T. P., Jr, Born M. L., Jones J. Radionuclide evaluation of right and left ventricular function in children: validation of methodology. Am J Cardiol. 1982 Apr 1;49(5):1241–1247. doi: 10.1016/0002-9149(82)90050-9. [DOI] [PubMed] [Google Scholar]
  11. Tynan M., Reid D. S., Hunter S., Kaye H. H., Osme S., Urquhart W., Davies P. Ejection phase indices of left ventricular performance in infants, children, and adults. Br Heart J. 1975 Feb;37(2):196–202. doi: 10.1136/hrt.37.2.196. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Upton M. T., Rerych S. K., Newman G. E., Bounous E. P., Jr, Jones R. H. The reproducibility of radionuclide angiographic measurements of left ventricular function in normal subjects at rest and during exercise. Circulation. 1980 Jul;62(1):126–132. doi: 10.1161/01.cir.62.1.126. [DOI] [PubMed] [Google Scholar]
  13. Wackers F. J., Berger H. J., Johnstone D. E., Goldman L., Reduto L. A., Langou R. A., Gottschalk A., Zaret B. L. Multiple gated cardiac blood pool imaging for left ventricular ejection fraction: validation of the technique and assessment of variability. Am J Cardiol. 1979 Jun;43(6):1159–1166. doi: 10.1016/0002-9149(79)90148-6. [DOI] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES