Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1984 Oct;52(4):462–464. doi: 10.1136/hrt.52.4.462

Pulmonary artery velocity patterns in ductus arteriosus.

N Wilson, D F Dickinson, S J Goldberg, O Scott
PMCID: PMC481660  PMID: 6477786

Abstract

In 12 patients with ductus arteriosus a characteristic velocity pattern in the pulmonary artery was identified using pulsed Doppler echocardiography. This pattern, which was absent in 52 normal control subjects and 200 consecutive patients with cardiac lesions other than ductus, consisted of a pandiastolic velocity directed away from the transducer. This pattern is thought to represent the diastolic component of flow into the pulmonary tree which occurs as a result of the left to right shunt.

Full text

PDF
462

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Allen H. D., Goldberg S. J., Valdes-Cruz L. M., Sahn D. J. Use of echocardiography in newborns with patent ductus arteriosus: a review. Pediatr Cardiol. 1982;3(1):65–70. doi: 10.1007/BF02082335. [DOI] [PubMed] [Google Scholar]
  2. BURNARD E. D. A murmur that may arise from the ductus arteriosus in the human baby. Proc R Soc Med. 1959 Jan;52(1):77–78. [PMC free article] [PubMed] [Google Scholar]
  3. Daniëls O., Hopman J. C., Stoelinga G. B., Busch H. J., Peer P. G. Doppler flow characteristics in the main pulmonary artery and the LA/Ao ratio before and after ductal closure in healthy newborns. Pediatr Cardiol. 1982;3(2):99–104. doi: 10.1007/BF02312956. [DOI] [PubMed] [Google Scholar]
  4. Kececioglu-Draelos Z., Goldberg S. J., Areias J., Sahn D. J. Verification and clinical demonstration of the echo Doppler series effect and vortex shed distance. Circulation. 1981 Jun;63(6):1422–1428. doi: 10.1161/01.cir.63.6.1422. [DOI] [PubMed] [Google Scholar]
  5. Sahn D. J., Allen H. D. Real-time cross-sectional echocardiographic imaging and measurement of the patent ductus arteriosus in infants and children. Circulation. 1978 Aug;58(2):343–354. doi: 10.1161/01.cir.58.2.343. [DOI] [PubMed] [Google Scholar]
  6. Serwer G. A., Armstrong B. E., Anderson P. A. Nonivasive detection of retrograde descending aortic flow in infants using continuous wave doppler ultrasonography. Implications for diagnosis of aortic run-off lesions. J Pediatr. 1980 Sep;97(3):394–400. doi: 10.1016/s0022-3476(80)80188-0. [DOI] [PubMed] [Google Scholar]
  7. Smallhorn J. F., Huhta J. C., Anderson R. H., Macartney F. J. Suprasternal cross-sectional echocardiography in assessment of patient ducts arteriosus. Br Heart J. 1982 Oct;48(4):321–330. doi: 10.1136/hrt.48.4.321. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Stevenson J. G., Kawabori I., Guntheroth W. G. Noninvasive detection of pulmonary hypertension in patent ductus arteriosus by pulsed Doppler echocardiography. Circulation. 1979 Aug;60(2):355–359. doi: 10.1161/01.cir.60.2.355. [DOI] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES