Abstract
Emission computed tomography with thallium-201 was compared with planar imaging in its ability to detect myocardial infarctions of various sizes four weeks after the onset. Tomography was performed after planar imaging at rest in 160 patients with a first myocardial infarction, in whom infarct size was prospectively estimated by the peak value of creatine kinase activity at the time of the acute episode and in 39 patients without infarction. The planar images and the transaxial, short axial, and long axial tomograms were interpreted qualitatively. Tomography was significantly more sensitive than planar imaging in detecting anterior (87% v 96%), inferior (73% v 97%), and non-transmural (47% v 87%) infarcts. The increased sensitivity was confined to detecting small infarcts as assessed by the peak creatine kinase value (44% v 89% when peak creatine kinase activity was less than or equal to 1000 IU/l). The overall sensitivity was 96% for tomography and 78% for planar imaging. The specificity was similar (92%) with the two techniques. Thus emission computed tomography can improve the detection rate of small infarcts that cannot be identified on planar images, by showing the three dimensional distribution of thallium-201, and increases the diagnostic value of thallium-201 scintigraphy.
Full text
PDF






Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Austen W. G., Edwards J. E., Frye R. L., Gensini G. G., Gott V. L., Griffith L. S., McGoon D. C., Murphy M. L., Roe B. B. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation. 1975 Apr;51(4 Suppl):5–40. doi: 10.1161/01.cir.51.4.5. [DOI] [PubMed] [Google Scholar]
- Bailey I. K., Griffith L. S., Rouleau J., Strauss W., Pitt B. Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease. Circulation. 1977 Jan;55(1):79–87. doi: 10.1161/01.cir.55.1.79. [DOI] [PubMed] [Google Scholar]
- Borrello J. A., Clinthorne N. H., Rogers W. L., Thrall J. H., Keyes J. W., Jr Oblique-angle tomography: a restructuring algorithm for transaxial tomographic data. J Nucl Med. 1981 May;22(5):471–473. [PubMed] [Google Scholar]
- Botvinick E. H., Taradash M. R., Shames D. M., Parmley W. W. Thallium-20 1 myocardial perfusion scintigraphy for the clinical clarification of normal, abnormal and equivocal electrocardiographic stress tests. Am J Cardiol. 1978 Jan;41(1):43–51. doi: 10.1016/0002-9149(78)90130-3. [DOI] [PubMed] [Google Scholar]
- Budinger T. F. Physical attributes of single-photon tomography. J Nucl Med. 1980 Jun;21(6):579–592. [PubMed] [Google Scholar]
- Hamilton G. W., Trobaugh G. B., Ritchie J. L., Williams D. L., Weaver W. D., Gould K. L. Myocardial imaging with intravenously injected thallium-201 in patients with suspected coronary artery disease: analysis of technique and correlation with electrocardiographic, coronary anatomic and ventriculographic findings. Am J Cardiol. 1977 Mar;39(3):347–354. doi: 10.1016/s0002-9149(77)80087-8. [DOI] [PubMed] [Google Scholar]
- Henning H., Schelbert H. R., Righetti A., Ashburn W. L., O'Rourke R. A. Dual myocardial imaging with technetium-99m pyrophosphate and thallium-201 for detecting, localizing and sizing acute myocardial infarction. Am J Cardiol. 1977 Aug;40(2):147–155. doi: 10.1016/0002-9149(77)90001-7. [DOI] [PubMed] [Google Scholar]
- Jaszczak R. J., Whitehead F. R., Lim C. B., Coleman R. E. Lesion detection with single-photon emission computed tomography (SPECT) compared with conventional imaging. J Nucl Med. 1982 Feb;23(2):97–102. [PubMed] [Google Scholar]
- Kambara H., Ishii Y. Thallium-201 Myocardial scintigraphy: quantification and its image processing. Jpn Circ J. 1981 Jan;45(1):120–126. doi: 10.1253/jcj.45.120. [DOI] [PubMed] [Google Scholar]
- Maublant J., Cassagnes J., Le Jeune J. J., Mestas D., Veyre A., Jallut H., Meyniel G. A comparison between conventional scintigraphy and emission tomography with thallium-201 in the detection of myocardial infarction: concise communication. J Nucl Med. 1982 Mar;23(3):204–208. [PubMed] [Google Scholar]
- Mueller T. M., Marcus M. L., Ehrhardt J. C., Chaudhuri T., Abboud F. M. Limitations of thallium-201 myocardial perfusion scintigrams. Circulation. 1976 Oct;54(4):640–646. doi: 10.1161/01.cir.54.4.640. [DOI] [PubMed] [Google Scholar]
- Murphy P. H., Thompson W. L., Moore M. L., Burdine J. A. Radionuclide computed tomography of the body using routine radiopharmaceuticals. I. System characterization. J Nucl Med. 1979 Feb;20(2):102–107. [PubMed] [Google Scholar]
- Niess G. S., Logic J. R., Russell R. O., Jr, Rackley C. E., Rogers W. J. Usefulness and limitations of thallium-201 myocardial scintigraphy in delineating location and size of prior myocardial infarction. Circulation. 1979 May;59(5):1010–1019. doi: 10.1161/01.cir.59.5.1010. [DOI] [PubMed] [Google Scholar]
- Perez-Gonzalez J., Botvinick E. H., Dunn R., Rahimtoola S., Ports T., Chatterjee K., Parmley W. W. The late prognostic value of acute scintigraphic measurement of myocardial infarction size. Circulation. 1982 Nov;66(5):960–971. doi: 10.1161/01.cir.66.5.960. [DOI] [PubMed] [Google Scholar]
- Ritchie J. L., Larsson S., Israelson A., Schnell P. O., Holmgren A., Williams D. L., Thorell J. I. Single photon tomographic imaging of a standard heart phantom with 201T1: a gamma camera based system. Eur J Nucl Med. 1982;7(6):254–259. doi: 10.1007/BF00251476. [DOI] [PubMed] [Google Scholar]
- Ritchie J. L., Williams D. L., Harp G., Stratton J. L., Caldwell J. H. Transaxial tomography with thallium-201 for detecting remote myocardial infarction. Comparison with planar imaging. Am J Cardiol. 1982 Dec;50(6):1236–1241. doi: 10.1016/0002-9149(82)90455-6. [DOI] [PubMed] [Google Scholar]
- Ritchie J. L., Zaret B. L., Strauss H. W., Pitt B., Berman D. S., Schelbert H. R., Ashburn W. L., Berger H. J., Hamilton G. W. Myocardial imaging with thallium-201: a multicenter study in patients with angina pectoris or acute myocardial infarction. Am J Cardiol. 1978 Sep;42(3):345–350. doi: 10.1016/0002-9149(78)90926-8. [DOI] [PubMed] [Google Scholar]
- Ryan W., Karliner J. S., Gilpin E. A., Covell J. W., DeLuca M., Ross J., Jr The creatine kinase curve area and peak creatine kinase after acute myocardial infarction: usefulness and limitations. Am Heart J. 1981 Feb;101(2):162–168. doi: 10.1016/0002-8703(81)90660-8. [DOI] [PubMed] [Google Scholar]
- Sammel N. L., Stuckey J. G., Brandt P. W., Norris R. M. Comparison of enzymic with cineangiocardiographic estimations of myocardial infarct size. Br Heart J. 1980 Jun;43(6):609–616. doi: 10.1136/hrt.43.6.609. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schuler G., Schwarz F., Hofmann M., Mehmel H., Manthey J., Mäurer W., Rauch B., Herrmann H. J., Kübler W. Thrombolysis in acute myocardial infarction using intracoronary streptokinase: assessment by thallium-201 scintigraphy. Circulation. 1982 Sep;66(3):658–664. doi: 10.1161/01.cir.66.3.658. [DOI] [PubMed] [Google Scholar]
- Silverman K. J., Becker L. C., Bulkley B. H., Burow R. D., Mellits E. D., Kallman C. H., Weisfeldt M. L. Value of early thallium-201 scintigraphy for predicting mortality in patients with acute myocardial infarction. Circulation. 1980 May;61(5):996–1003. doi: 10.1161/01.cir.61.5.996. [DOI] [PubMed] [Google Scholar]
- Tamaki N., Mukai T., Ishii Y., Fujita T., Yamamoto K., Minato K., Yonekura Y., Tamaki S., Kambara H., Kawai C. Comparative study of thallium emission myocardial tomography with 180 degrees and 360 degrees data collection. J Nucl Med. 1982 Aug;23(8):661–666. [PubMed] [Google Scholar]
- Tamaki N., Mukai T., Ishii Y., Yonekura Y., Kambara H., Kawai C., Torizuka K. Clinical evaluation of thallium-201 emission myocardial tomography using a rotating gamma camera: comparison with seven-pinhole tomography. J Nucl Med. 1981 Oct;22(10):849–855. [PubMed] [Google Scholar]
- Tamaki S., Murakami T., Kadota K., Kambara H., Yui Y., Nakajima H., Suzuki Y., Nohara R., Takatsu Y., Kawai C. Effects of coronary artery reperfusion on relation between creatine kinase-MB release and infarct size estimated by myocardial emission tomography with thallium-201 in man. J Am Coll Cardiol. 1983 Dec;2(6):1031–1038. doi: 10.1016/s0735-1097(83)80326-x. [DOI] [PubMed] [Google Scholar]
- Tamaki S., Nakajima H., Murakami T., Yui Y., Kambara H., Kadota K., Yoshida A., Kawai C., Tamaki N., Mukai T. Estimation of infarct size by myocardial emission computed tomography with thallium-201 and its relation to creatine kinase-MB release after myocardial infarction in man. Circulation. 1982 Nov;66(5):994–1001. doi: 10.1161/01.cir.66.5.994. [DOI] [PubMed] [Google Scholar]
- Uthurralt N., Parodi O., Severi S., Davies G., Maseri A. Thallium-201 scintigraphy for diagnosis of old myocardial infarction: comparison with electrocardiographic, ventriculographic, and coronary arteriographic findings. Br Heart J. 1980 May;43(5):527–534. doi: 10.1136/hrt.43.5.527. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wackers F. J., Becker A. E., Samson G., Sokole E. B., van der Schoot J. B., Vet A. J., Lie K. I., Durrer D., Wellens H. Location and size of acute transmural myocardial infarction estimated from thallium-201 scintiscans. A clinicopathological study. Circulation. 1977 Jul;56(1):72–78. doi: 10.1161/01.cir.56.1.72. [DOI] [PubMed] [Google Scholar]
- Wackers F. J., Schoot J. B., Sokole E. B., Samson G., Niftrik G. J., Lie K. I., Durrer D., Wellens H. J. Noninvasive visualization of acute myocardial infarction in man with thallium-201. Br Heart J. 1975 Jul;37(7):741–744. doi: 10.1136/hrt.37.7.741. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wackers F. J., Sokole E. B., Samson G., Schoot J. B., Lie K. I., Liem K. L., Wellens H. J. Value and limitations of thallium-201 scintigraphy in the acute phase of myocardial infarction. N Engl J Med. 1976 Jul 1;295(1):1–5. doi: 10.1056/NEJM197607012950101. [DOI] [PubMed] [Google Scholar]
- Williams D. L., Ritchie J. L., Harp G. D., Caldwell J. H., Hamilton G. W. In vivo simulation of thallium-201 myocardial scintigraphy by seven-pinhole emission tomography. J Nucl Med. 1980 Sep;21(9):821–828. [PubMed] [Google Scholar]