Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1985 Jun;53(6):640–644. doi: 10.1136/hrt.53.6.640

Increased blood velocities in the heart and great vessels of patients with congenital heart disease. An assessment of their significance in the absence of valvar stenosis.

S J Goldberg, N Wilson, D F Dickinson
PMCID: PMC481828  PMID: 4005087

Abstract

During a previous investigation and during routine clinical Doppler echocardiography velocities distal to normal valves were found to be increased in patients with congenital heart disease. To investigate this observation the velocity proximal and distal to cardiac valves was recorded in 56 patients with congenital heart disease. No detectable pressure gradient had been found across these valves at catheterisation and no velocity gradient greater than 20 cm/s was found across them by range gated Doppler echocardiography. In 82% of the patients, however, the blood velocity across one or more valves exceeded normal limits. Increased velocities were found at the tricuspid inflow (55%), pulmonary artery (38%), mitral inflow (34%), and ascending aorta (11%). Factors predisposing to the presence of increased velocities in these areas were increased flow through the valve and decreased compliance of the receiving chamber. This study shows the necessity for recording velocity both proximal and distal to a valve before a gradient is calculated according to the modified Bernouilli equation.

Full text

PDF
640

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Hatle L. Noninvasive assessment and differentiation of left ventricular outflow obstruction with Doppler ultrasound. Circulation. 1981 Aug;64(2):381–387. doi: 10.1161/01.cir.64.2.381. [DOI] [PubMed] [Google Scholar]
  2. Holen J., Aaslid R., Landmark K., Simonsen S. Determination of pressure gradient in mitral stenosis with a non-invasive ultrasound Doppler technique. Acta Med Scand. 1976;199(6):455–460. doi: 10.1111/j.0954-6820.1976.tb06763.x. [DOI] [PubMed] [Google Scholar]
  3. Kececioglu-Draelos Z., Goldberg S. J., Areias J., Sahn D. J. Verification and clinical demonstration of the echo Doppler series effect and vortex shed distance. Circulation. 1981 Jun;63(6):1422–1428. doi: 10.1161/01.cir.63.6.1422. [DOI] [PubMed] [Google Scholar]
  4. Loeber C. P., Goldberg S. J., Allen H. D. Doppler echocardiographic comparison of flows distal to the four cardiac valves. J Am Coll Cardiol. 1984 Aug;4(2):268–272. doi: 10.1016/s0735-1097(84)80212-0. [DOI] [PubMed] [Google Scholar]
  5. Simon A. L., Reis R. L. The angiographic features of bicuspid and unicommissural aortic stenosis. Am J Cardiol. 1971 Sep;28(3):353–358. doi: 10.1016/0002-9149(71)90127-5. [DOI] [PubMed] [Google Scholar]
  6. Stevenson J. G., Kawabori I., Dooley T., Guntheroth W. G. Diagnosis of ventricular septal defect by pulsed Doppler echocardiography. Sensitivity, specificity and limitations. Circulation. 1978 Aug;58(2):322–326. doi: 10.1161/01.cir.58.2.322. [DOI] [PubMed] [Google Scholar]
  7. Wilson N., Dickinson D. F., Goldberg S. J., Scott O. Pulmonary artery velocity patterns in ductus arteriosus. Br Heart J. 1984 Oct;52(4):462–464. doi: 10.1136/hrt.52.4.462. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Wilson N., Goldberg S. J., Dickinson D. F., Scott O. Normal intracardiac and great artery blood velocity measurements by pulsed Doppler echocardiography. Br Heart J. 1985 Apr;53(4):451–458. doi: 10.1136/hrt.53.4.451. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES