Abstract
Specifications recommended for electrocardiographs omit any reference to phase characteristics and place undue emphasis on an extended amplitude response. This does not, however, ensure faithful reproduction of the electrocardiogram and may result in less effective attenuation of unwanted noise than can be achieved with modern filters. The separate effects of phase and amplitude response on electrocardiographic signals were compared, and it was shown that distortion of the electrocardiogram by equipment with an inadequate phase response may cause changes resembling those seen in ischaemic heart disease. Case reports are presented in which distortion produced by commercial equipment impeded diagnosis. Specifications recommended as standard for electrocardiographs should be modified to include phase response and allow greater attenuation of frequencies below 0.5 Hz.
Full text
PDF







Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Balasubramanian V., Lahiri A., Green H. L., Stott F. D., Raftery E. B. Ambulatory ST segment monitoring. Problems, pitfalls, solutions, and clinical application. Br Heart J. 1980 Oct;44(4):419–425. doi: 10.1136/hrt.44.4.419. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Berson A. S., Pipberger H. V. The low-frequency response of electrocardiographs, a frequent source of recording errors. Am Heart J. 1966 Jun;71(6):779–789. doi: 10.1016/0002-8703(66)90599-0. [DOI] [PubMed] [Google Scholar]
- Bragg-Remschel D. A., Anderson C. M., Winkle R. A. Frequency response characteristics of ambulatory ECG monitoring systems and their implications for ST segment analysis. Am Heart J. 1982 Jan;103(1):20–31. doi: 10.1016/0002-8703(82)90524-5. [DOI] [PubMed] [Google Scholar]
- Favret A. G., Caputo A. F. Evaluation of autocorrelation techniques for detection of the fetal electrocardiogram. IEEE Trans Biomed Eng. 1966 Jan;13(1):37–43. doi: 10.1109/tbme.1966.4502398. [DOI] [PubMed] [Google Scholar]
- Golden D. P., Jr, Wolthuis R. A., Hoffler G. W. A spectral analysis of the normal resting electrocardiogram. IEEE Trans Biomed Eng. 1973 Sep;20(5):366–372. doi: 10.1109/TBME.1973.324231. [DOI] [PubMed] [Google Scholar]
- Longini R. L., Giolma J. P., Wall C., 3rd, Quick R. F. Filtering without phase shift. IEEE Trans Biomed Eng. 1975 Sep;22(5):432–433. doi: 10.1109/tbme.1975.324517. [DOI] [PubMed] [Google Scholar]
- Lynn P. A. Transversal resonator digital filters: fast and flexible online processors for biological signals. Med Biol Eng Comput. 1983 Nov;21(6):718–730. doi: 10.1007/BF02464035. [DOI] [PubMed] [Google Scholar]
- Richardson J. M., Murthy V. K., Haywood L. J. Effect of random frequency modulation on ECG power spectra. IEEE Trans Biomed Eng. 1979 Feb;26(2):109–112. doi: 10.1109/tbme.1979.326519. [DOI] [PubMed] [Google Scholar]
- Tayler D., Vincent R. Signal distortion in the electrocardiogram due to inadequate phase response. IEEE Trans Biomed Eng. 1983 Jun;30(6):352–356. doi: 10.1109/tbme.1983.325137. [DOI] [PubMed] [Google Scholar]
- Wagner J. W. A simple test for phase characteristics of chart recorders. IEEE Trans Biomed Eng. 1979 Sep;26(9):505–508. doi: 10.1109/tbme.1979.326431. [DOI] [PubMed] [Google Scholar]