Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1985 Oct;54(4):367–374. doi: 10.1136/hrt.54.4.367

New technique for showing the relation of tomographic myocardial perfusion images obtained with thallium-201 to the coronary arteries.

C J Gibson, E E Laird, E D Williams, A Rajathurai, B Mittra, D Rankin
PMCID: PMC481912  PMID: 3876840

Abstract

A new technique has been developed for presenting myocardial tomograms that allows the observer to perceive the shape of the thallium-201 distribution directly. The surface of the myocardium was found by applying an interactive thresholding technique to a set of conventional transverse slices. Computer graphics techniques were used to display a shaded image of that surface on a television screen, showing the three dimensional shape of the myocardial surface from any chosen aspect. A set of normal preserved coronary arteries was digitised, and using scaling and transformation techniques these arteries were mapped on to the myocardial tomograms and a shaded surface image produced with superimposed coronary arteries. This provided a familiar anatomical framework for locating perfusion defects. Its value in identifying various diseased vessels was confirmed by a comparison of the tomographic findings with the angiographic findings in five individual cases.

Full text

PDF
367

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Berger B. C., Watson D. D., Taylor G. J., Craddock G. B., Martin R. P., Teates C. D., Beller G. A. Quantitative thallium-201 exercise scintigraphy for detection of coronary artery disease. J Nucl Med. 1981 Jul;22(7):585–593. [PubMed] [Google Scholar]
  2. Buell U., Kleinhans E., Seiderer M., Strauer B. E. Quantitative assessment of thallium-201 images. Cardiovasc Radiol. 1979 Sep;2(3):183–193. doi: 10.1007/BF02552063. [DOI] [PubMed] [Google Scholar]
  3. Burow R. D., Pond M., Schafer A. W., Becker L. "Circumferential profiles:" a new method for computer analysis of thallium-201 myocardial perfusion images. J Nucl Med. 1979 Jul;20(7):771–777. [PubMed] [Google Scholar]
  4. Francisco D. A., Collins S. M., Go R. T., Ehrhardt J. C., Van Kirk O. C., Marcus M. L. Tomographic thallium-201 myocardial perfusion scintigrams after maximal coronary artery vasodilation with intravenous dipyridamole. Comparison of qualitative and quantitative approaches. Circulation. 1982 Aug;66(2):370–379. doi: 10.1161/01.cir.66.2.370. [DOI] [PubMed] [Google Scholar]
  5. Gibson C. J. A new method for the three-dimensional display of tomographic images. Phys Med Biol. 1983 Oct;28(10):1153–1157. doi: 10.1088/0031-9155/28/10/007. [DOI] [PubMed] [Google Scholar]
  6. Hampton J. R. Coronary artery bypass grafting for the reduction of mortality: an analysis of the trials. Br Med J (Clin Res Ed) 1984 Nov 3;289(6453):1166–1170. doi: 10.1136/bmj.289.6453.1166. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Houston A. S., Elliott A. T., Stone D. L. Factorial phase imaging: a new concept in the analysis of first-pass cardiac studies. Phys Med Biol. 1982 Oct;27(10):1269–1277. doi: 10.1088/0031-9155/27/10/007. [DOI] [PubMed] [Google Scholar]
  8. Iskandrian A. S., Wasserman L. A., Anderson G. S., Hakki H., Segal B. L., Kane S. Merits of stress thallium-201 myocardial perfusion imaging in patients with inconclusive exercise electrocardiograms: correlation with coronary arteriograms. Am J Cardiol. 1980 Oct;46(4):553–558. doi: 10.1016/0002-9149(80)90502-0. [DOI] [PubMed] [Google Scholar]
  9. King M. A., Schwinger R. B., Doherty P. W., Penney B. C. Two-dimensional filtering of SPECT images using the Metz and Wiener filters. J Nucl Med. 1984 Nov;25(11):1234–1240. [PubMed] [Google Scholar]
  10. Laird E. E., Rajathurai A., Williams E. D., Mittra B., Rankin D. Quantitative analysis of rotating gamma camera thallium-201 scintigrams of myocardium. Nucl Med Commun. 1984 Sep;5(9):577–586. doi: 10.1097/00006231-198409000-00007. [DOI] [PubMed] [Google Scholar]
  11. McCarthy D. M., Blood D. K., Sciacca R. R., Cannon P. J. Single dose myocardial perfusion imaging with thallium-201: application in patients with nondiagnostic electrocardiographic stress tests. Am J Cardiol. 1979 May;43(5):899–906. doi: 10.1016/0002-9149(79)90351-5. [DOI] [PubMed] [Google Scholar]
  12. Myers M. J., Sokole E. B., de Bakker J. A comparison of rotating slant hole collimator and rotating camera for single photon emission tomography of the heart. Phys Med Biol. 1983 May;28(5):581–588. doi: 10.1088/0031-9155/28/5/010. [DOI] [PubMed] [Google Scholar]
  13. Okada R. D., Boucher C. A., Kirshenbaum H. K., Kushner F. G., Strauss H. W., Block P. C., McKusick K. A., Pohost G. M. Improved diagnostic accuracy of thallium-201 stress test using multiple observers and criteria derived from interobserver analysis of variance. Am J Cardiol. 1980 Oct;46(4):619–624. doi: 10.1016/0002-9149(80)90512-3. [DOI] [PubMed] [Google Scholar]
  14. Rigo P., Bailey I. K., Griffith L. S., Pitt B., Burow R. D., Wagner H. N., Jr, Becker L. C. Value and limitations of segmental analysis of stress thallium myocardial imaging for localization of coronary artery disease. Circulation. 1980 May;61(5):973–981. doi: 10.1161/01.cir.61.5.973. [DOI] [PubMed] [Google Scholar]
  15. Strauss H. W., Pitt B. Evaluation of cardiac function and structure with radioactive tracer techniques. Circulation. 1978 Apr;57(4):645–654. doi: 10.1161/01.cir.57.4.645. [DOI] [PubMed] [Google Scholar]
  16. Tamaki N., Mukai T., Ishii Y., Yonekura Y., Kambara H., Kawai C., Torizuka K. Clinical evaluation of thallium-201 emission myocardial tomography using a rotating gamma camera: comparison with seven-pinhole tomography. J Nucl Med. 1981 Oct;22(10):849–855. [PubMed] [Google Scholar]
  17. Tamaki N., Yonekura Y., Mukai T., Fujita T., Nohara R., Kadota K., Kambara H., Kawai C., Torizuka K., Ishii Y. Segmental analysis of stress thallium myocardial emission tomography for localization of coronary artery disease. Eur J Nucl Med. 1984;9(3):99–105. doi: 10.1007/BF00253509. [DOI] [PubMed] [Google Scholar]
  18. Totty W. G., Vannier M. W. Complex musculoskeletal anatomy: analysis using three dimensional surface reconstruction. Radiology. 1984 Jan;150(1):173–177. doi: 10.1148/radiology.150.1.6689757. [DOI] [PubMed] [Google Scholar]
  19. Trobaugh G. B., Wackers F. J., Sokole E. B., DeRouen T. A., Ritchie J. L., Hamilton G. W. Thallium-201 myocardial imaging: an interinstitutional study of observer variability. J Nucl Med. 1978 Apr;19(4):359–363. [PubMed] [Google Scholar]
  20. Vannier M. W., Marsh J. L., Warren J. O. Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation. Radiology. 1984 Jan;150(1):179–184. doi: 10.1148/radiology.150.1.6689758. [DOI] [PubMed] [Google Scholar]
  21. Wainwright R. J. Scintigraphic anatomy of coronary artery disease in digital thallium-201 myocardial images. Br Heart J. 1981 Nov;46(5):465–477. doi: 10.1136/hrt.46.5.465. [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Wainwrwight R. J., Maisey M. N., Sowton E. Segmental quantitative analysis of digital thallium-201 myocardial scintigrams in diagnosis of coronary artery disease. Comparison with rest and exercise electrocardiography and coronary arteriography. Br Heart J. 1981 Nov;46(5):478–485. doi: 10.1136/hrt.46.5.478. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES