Abstract
A comparison was made in 7 dogs of the results obtained by 6 different apex cardiographic transducers applied before, during, and after controlled infusion of angiotensin and isoprenaline. The electrocardiogram, internal phonocardiogram, aortic and left ventricular pressure using a Telco micromanometer, and apex cardiogram were recorded simultaneously on magnetic tape and paper. Digital computer techniques were used to derive various measurements. The comparison of the 6 transducer systems was made expecially with respect to measurements derived from the normalised derivative, calculated using total as well as developed pressure or displacement. Measurements derived from left ventricular pressure were very reproducible. Differences in results of 'contractility' indices varied between 0.5 and 1.9 per cent. Indices from the apex cardiogram using 6 different transducer systems showed variations up to 20 per cent, with mean values varying between 3.2 and 8.1 per cent. There was a systematic deviation for one transducer system, which was responsible for a significant part of the observed variability. It may be concluded that in order to assure maximal reproducibility, technical characteristics of the apex cardiograph transducer should be taken into account and an optimal recording technique should be used.
Full text
PDF










Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- BENCHIMOL A., DIMOND E. G. THE NORMAL AND ABNORMAL APEXCARDIOGRAM. ITS PHYSIOLOGIC VARIATION AND ITS RELATION TO INTRACARDIAC EVENTS. Am J Cardiol. 1963 Sep;12:368–381. doi: 10.1016/0002-9149(63)90232-7. [DOI] [PubMed] [Google Scholar]
- Denef B., De Geest H., Kesteloot H. Influence of changes in myocardial contractility on the height and slope of the calibrated apex cardiogram. Am J Cardiol. 1973 Oct;32(5):662–669. doi: 10.1016/s0002-9149(73)80060-8. [DOI] [PubMed] [Google Scholar]
- Denef B., Popeye R., Geest H. D., Kesteloot H. On the clinical value of calibrated displacement apexcardiography. Circulation. 1975 Mar;51(3):541–551. doi: 10.1161/01.cir.51.3.541. [DOI] [PubMed] [Google Scholar]
- Falsetti H. L., Mates R. E., Greene D. G., Bunnell I. L. Vmax as an index of contractile state in man. Circulation. 1971 Apr;43(4):467–479. doi: 10.1161/01.cir.43.4.467. [DOI] [PubMed] [Google Scholar]
- Fincker J. L., Arnold P., Brandt C., Vergnes R., Meyer P. La dérivée première du cardiogramme apexien. Technique et résultats chez les sujets normaux. Arch Mal Coeur Vaiss. 1971 Aug;64(8):1194–1210. [PubMed] [Google Scholar]
- Ginn W. M., Sherwin R. W., Harrison W. K., Baker B. M. Apexcardiography: use in coronary heart disease and reproducibility. Am Heart J. 1967 Feb;73(2):168–180. doi: 10.1016/0002-8703(67)90145-7. [DOI] [PubMed] [Google Scholar]
- Johnson J. M., Siegel W., Blomqvist G. Characteristics of transducers used for recording the apexcardiogram. J Appl Physiol. 1971 Nov;31(5):796–800. doi: 10.1152/jappl.1971.31.5.796. [DOI] [PubMed] [Google Scholar]
- Kesteloot H., Willems J., van Vollenhoven E. On the physical principles and methodology of mechanocardiography. Acta Cardiol. 1969;24(2):147–160. [PubMed] [Google Scholar]
- Mason D. T., Spann J. F., Jr, Zelis R. Quantification of the contractile state of the intact human heart. Maximal velocity of contractile element shortening determined by the instantaneous relation between the rate of pressure rise and pressure in the left ventricle during isovolumic systole. Am J Cardiol. 1970 Sep;26(3):248–257. doi: 10.1016/0002-9149(70)90791-5. [DOI] [PubMed] [Google Scholar]
- Mirsky I., Pasternac A., Ellison R. C. General index for the assessment of cardiac function. Am J Cardiol. 1972 Oct;30(5):483–491. doi: 10.1016/0002-9149(72)90038-0. [DOI] [PubMed] [Google Scholar]
- Motomura M., Omae M., Uehata H., Kumata T., Yaginuma T. An apex cardiographic index "(peak DA-DT)-A" for the assessment of left ventricular function. Jpn Circ J. 1973 Nov;37(11):1355–1359. doi: 10.1253/jcj.37.1355. [DOI] [PubMed] [Google Scholar]
- Nilsson K., Thulesius O. A combined microphone for simultaneous recording of pulse and heart sounds. Biomed Eng. 1973 Oct;8(10):424–passim. [PubMed] [Google Scholar]
- Reale A. Evaluation of the contractile state of the human heart from the first derivative of the apexcardiogram. Circulation. 1967 Dec;36(6):933–941. doi: 10.1161/01.cir.36.6.933. [DOI] [PubMed] [Google Scholar]
- Spodick D. H. On experts and expertise: the effect of variability in observer performance. Am J Cardiol. 1975 Oct 31;36(5):592–596. doi: 10.1016/0002-9149(75)90156-3. [DOI] [PubMed] [Google Scholar]
- Tricot R., Cavailles J., Veber G. Utilisation d'un capteur à variation d'inductance pour l'enregistrement des phénomènes mécaniques cardiaques. Arch Mal Coeur Vaiss. 1966 May;59(5):805–816. [PubMed] [Google Scholar]
- Van de Werf F., Piessens J., De Geest H., Kesteloot H. Normalized first derivative ofthe left apex cardiogram in assessment of left ventricular function. Am J Cardiol. 1976 Jun;37(7):1059–1064. doi: 10.1016/0002-9149(76)90424-0. [DOI] [PubMed] [Google Scholar]
- Vetter W. R., Sullivan R. W., Hyatt K. H. Assessment of quantitative apex cardiography. A noninvasive index of left ventricular function. Am J Cardiol. 1972 May;29(5):667–671. doi: 10.1016/0002-9149(72)90168-3. [DOI] [PubMed] [Google Scholar]
- Wayne H. H. The apexcardiogram in ischemic heart disease. Calif Med. 1972 Jan;116(1):12–20. [PMC free article] [PubMed] [Google Scholar]
- Willems J. L., De Geest H., Kesteloot H. A new approach to the recording of low frequency precordial vibrations. Acta Cardiol. 1971;26(3):263–276. [PubMed] [Google Scholar]
- Willems J. L., De Geest H., Kesteloot H. On the value of apex cardiography for timing intracardiac events. Am J Cardiol. 1971 Jul;28(1):59–66. doi: 10.1016/0002-9149(71)90035-x. [DOI] [PubMed] [Google Scholar]
- Willems J. L., Kesteloot H., De Geest H. Influence of acute hemodynamic changes on the apex cardiogram in dogs. Am J Cardiol. 1972 Apr;29(4):504–513. doi: 10.1016/0002-9149(72)90440-7. [DOI] [PubMed] [Google Scholar]
- Willems J. L., Kyle M. C., Pillsbury H. C. First derivative of the apex cardiogram and systolic time intervals in evaluation of myocardial contractility in man. Am J Cardiol. 1975 Dec;36(7):873–879. doi: 10.1016/0002-9149(75)90076-4. [DOI] [PubMed] [Google Scholar]