Doppler echocardiography in the study of patients with mitral disc valve prostheses.

S Nitter-Hauge
PMCID: PMC482315  PMID: 6689922

Abstract

A combination of M mode and Doppler echocardiography was used to study patients with mitral disc valve prostheses. The probe used in these investigations consisted of a circular Doppler crystal mounted around the M mode crystal in the same plane. Because of the strong echoes produced by the prosthesis the transducer (probe) could be angled for optimum Doppler signals without losing the M mode echocardiographic recording of the prosthesis. With this equipment mean and maximum blood velocities and Doppler amplitude signals could be measured simultaneously with M mode echocardiography. A depth indication line in the M mode recording ensured that the Doppler signal was recorded in the region of interest. The Doppler ultrasound technique was also used separately in both the pulsed wave and the continuous wave mode. The data show the usefulness of this technique in patients with normally functioning valve prostheses and in three patients with valve malfunction due to thrombus formation. The data in the latter three cases seem to indicate that the Doppler technique provides valuable information in addition to that obtained by M mode echocardiography in recognising mitral valve prosthetic malfunction.

Full text

PDF
61

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bourdillon P. D., Sharratt G. P. Malfunction of Björk-Shiley valve prosthesis in tricuspid position. Br Heart J. 1976 Nov;38(11):1149–1153. doi: 10.1136/hrt.38.11.1149. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Brubakk A. O., Angelsen B. A., Hatle L. Diagnosis of valvular heart disease using transcutaneous Doppler ultrasound. Cardiovasc Res. 1977 Sep;11(5):461–469. doi: 10.1093/cvr/11.5.461. [DOI] [PubMed] [Google Scholar]
  3. Clements S. D., Jr, Perkins J. V. Malfunction of a Bjork-Shiley prosthetic heart valve in the mitral position producing an abnormal echocardiographic pattern. J Clin Ultrasound. 1978 Oct;6(5):334–336. doi: 10.1002/jcu.1870060512. [DOI] [PubMed] [Google Scholar]
  4. Copans H., Lakier J. B., Kinsley R. H., Colsen P. R., Fritz V. U., Barlow J. B. Thrombosed Björk-Shiley mitral prostheses. Circulation. 1980 Jan;61(1):169–174. doi: 10.1161/01.cir.61.1.169. [DOI] [PubMed] [Google Scholar]
  5. Gibson T. C., Starek P. J., Moos S., Craige E. Echocardiographic and phonocardiographic characteristics of the lillehei-kaster mitral valve prosthesis. Circulation. 1974 Mar;49(3):434–440. doi: 10.1161/01.cir.49.3.434. [DOI] [PubMed] [Google Scholar]
  6. Holen J., Nitter-Hauge S. Evaluation of obstructive characteristics of mitral disc valve implants with ultrasound doppler techniques. Acta Med Scand. 1977;201(5):429–434. doi: 10.1111/j.0954-6820.1977.tb15725.x. [DOI] [PubMed] [Google Scholar]
  7. Holen J., Simonsen S., Frøysaker T. An ultrasound Doppler technique for the noninvasive determination of the pressure gradient in the Björk-Shiley mitral valve. Circulation. 1979 Mar;59(3):436–442. doi: 10.1161/01.cir.59.3.436. [DOI] [PubMed] [Google Scholar]
  8. Johnson M. L., Holmes J. H., Paton B. C. Echocardiographic determination of mitral disc valve excursion. Circulation. 1973 Jun;47(6):1274–1280. doi: 10.1161/01.cir.47.6.1274. [DOI] [PubMed] [Google Scholar]
  9. Kawai N., Segal B. L., Linhart J. W. Delayed opening of Beall mitral prosthetic valve detected by echocardiography. Chest. 1975 Feb;67(2):239–241. doi: 10.1378/chest.67.2.239. [DOI] [PubMed] [Google Scholar]
  10. Nitter-Hauge S., Froysaker T., Hall K. V. Clinical and haemodynamic results following mitral valve replacement with the new Lillehei-Kaster pivoting disc valve prosthesis. Scand J Thorac Cardiovasc Surg. 1977;11(1):15–24. doi: 10.3109/14017437709167808. [DOI] [PubMed] [Google Scholar]
  11. Nitter-Hauge S., Hall K. V., Froysaker T. Mitral valve replacement. A comparative clinical and haemodynamic study of the new Lillehei-Kaster and Björk-Shiley prostheses. Scand J Thorac Cardiovasc Surg. 1977;11(2):111–117. [PubMed] [Google Scholar]
  12. Oliva P. B., Johnson M. L., Pomerantz M., Levene A. Dysfunction of the Beall mitral prosthesis and its detection by cinefluoroscopy and echocardiography. Am J Cardiol. 1973 Mar;31(3):393–396. doi: 10.1016/0002-9149(73)90275-0. [DOI] [PubMed] [Google Scholar]
  13. Pfeifer J., Godlschlager N., Sweatman T., Gerbode F., Selzer A. Malfunction of mitral ball valve prosthesis due to thrombus. Report of 2 cases with notes on early clinical diagnosis. Am J Cardiol. 1972 Jan;29(1):95–99. doi: 10.1016/0002-9149(72)90422-5. [DOI] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES