Abstract
Echocardiographic dimensions in infants (less than 2 months) with pulmonary hypertension, associated with coarctation of the aorta in 21, total anomalous venous return in 10, and left-to-right shunts in 14 were compared with 10 infants with respiratory distress syndrome, seven with transient tachypnoea of the newborn, 20 normal children, and with each other. Distinguishing features of total anomalous pulmonary venous return were very significantly lower left atrial and left ventricular dimensions. Right ventricular enlargement was maximal in patients with coarctation of the aorta and total anomalous pulmonary venous return. Left ventricular end-diastolic dimension in coarctation of the aorta was not significantly different from normal but the left ventricular end-systolic dimension was significantly lower, suggesting a hypercontractile left ventricle. Similar findings were observed in patients with left-to-right shunts. M-mode echocardiograms are hence valuable in differentiating conditions which may present with intractable congestive cardiac failure in the newborn and also distinguishing them from common respiratory disease of the neonate.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Aziz K. U., Paul M. H., Bharati S., Lev M., Shannon K. Echocardiographic features of total anomalous pulmonary venous drainage into the coronary sinus. Am J Cardiol. 1978 Jul;42(1):108–113. doi: 10.1016/0002-9149(78)90993-1. [DOI] [PubMed] [Google Scholar]
- Bloom K. R., Rodrigues L., Swan E. M. Echocardiographic evaluation of left-to-right shunt in ventricular septal defect and persistent ductus arteriosus. Br Heart J. 1977 Mar;39(3):260–265. doi: 10.1136/hrt.39.3.260. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bove K. E., Geiser E. A., Meyer R. A. The left ventricle in anomalous pulmonary venous return. Morphometric analysis of 36 fatal cases in infancy. Arch Pathol. 1975 Oct;99(10):522–528. [PubMed] [Google Scholar]
- Brown O. R., Harrison D. C., Popp R. L. An improved method for echographic detection of left atrial enlargement. Circulation. 1974 Jul;50(1):58–64. doi: 10.1161/01.cir.50.1.58. [DOI] [PubMed] [Google Scholar]
- Godman M. J., Tham P., Kidd B. S. Echocardiography in the evaluation of the cyanotic newborn infant. Br Heart J. 1974 Feb;36(2):154–166. doi: 10.1136/hrt.36.2.154. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Graham T. P., Jr, Jarmakani J. M., Canent R. V., Jr Left heart volume characteristics with a right ventricular volume overload. Total anomalous pulmonary venous connection and large atrial septal defect. Circulation. 1972 Feb;45(2):389–396. doi: 10.1161/01.cir.45.2.389. [DOI] [PubMed] [Google Scholar]
- Halliday H., Hirschfeld S., Riggs T., Liebman J., Fanaroff A., Bormuth C. Respiratory distress syndrome: echocardiographic assessment of cardiovascular function and pulmonary vascular resistance. Pediatrics. 1977 Oct;60(4):444–449. [PubMed] [Google Scholar]
- Hirschfeld S., Meyer R., Schwartz D. C., Korfhagen J., Kaplan S. Measurement of right and left ventricular systolic time intervals by echocardiography. Circulation. 1975 Feb;51(2):304–309. doi: 10.1161/01.cir.51.2.304. [DOI] [PubMed] [Google Scholar]
- Meyer R. A., Stockert J., Kaplan S. Echographic determination of left ventricular volumes in pediatric patients. Circulation. 1975 Feb;51(2):297–303. doi: 10.1161/01.cir.51.2.297. [DOI] [PubMed] [Google Scholar]
- Paquet M., Gutgesell H. Echocardiographic features of total anomalous pulmonary venous connection. Circulation. 1975 Apr;51(4):599–605. doi: 10.1161/01.cir.51.4.599. [DOI] [PubMed] [Google Scholar]
- Riggs T., Hirschfeld S., Bormuth C., Fanaroff A., Liebman J. Neonatal circulatory changes: an echocardiographic study. Pediatrics. 1977 Mar;59(3):338–344. [PubMed] [Google Scholar]
- Rudolph A. M. The changes in the circulation after birth. Their importance in congenital heart disease. Circulation. 1970 Feb;41(2):343–359. doi: 10.1161/01.cir.41.2.343. [DOI] [PubMed] [Google Scholar]
- Sasse L., Bozio A., Davignon A. Letter: Interpreting the echocardiogram in TAPVC. Circulation. 1976 Jun;53(6):1041–1042. doi: 10.1161/01.cir.53.6.1041. [DOI] [PubMed] [Google Scholar]
- Wing J. P., Findlay W. A., Sahn D. J., McDonald G., Allen H. D., Goldberg S. J. Serial echocardiographic profiles in infants and children with coarctation of the aorta. Am J Cardiol. 1978 Jun;41(7):1270–1277. doi: 10.1016/0002-9149(78)90885-8. [DOI] [PubMed] [Google Scholar]