Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1980 Dec;44(6):692–698. doi: 10.1136/hrt.44.6.692

Differential atrial filling after Mustard and Senning repairs. Detection by transcutaneous Doppler ultrasound.

R K Wyse, F J Macartney, J Rohmer, J Ottenkamp, A G Brom
PMCID: PMC482467  PMID: 7459153

Abstract

The dominance of Mustard's operation for transposition of the great arteries has been challenged by the recent revival of Senning's repair because it promises better long-term results in terms of venous obstruction and atrial haemodynamics. These hypotheses were tested by recording jugular venous flow waveforms transcutaneously in 24 postoperative patients with simple complete transposition using a bidirectional Doppler blood velocimeter. Eight patients had undergone Mustard's operation and 16 the Senning alternative; all had previously had a postoperative cardiac catheterisation. Both groups of patients had similar left ventricular, pulmonary arterial, and systemic venous atrial pressures. No child showed any evidence at catheterisation of either mitral regurgitation or of superior vena caval pathway obstruction. These two findings were endorsed by the transcutaneous Doppler recordings. Jugular venous flow in normal children exhibits two maxima, one of atrial filling during ventricular systole, the other of ventricular filling occurs once the tricuspid valve has opened. Both operative procedures diminished the size of the former phase, but the Mustard did so more. After Mustard's operation forward flow during the atrial filling phase was absent in approximately half the cardiac cycles recorded, and severely diminished in the rest. By contrast, there was approximately a 90 per cent appearance of atrial filling waves after Senning's operation which also provided significantly better atrial function than Mustard's procedure in terms of peak velocity of blood entering the atrium and total atrial filling. It is therefore concluded that both procedures compromise atrial volume and compliance but Senning's repair to a much lesser extent.

Full text

PDF
692

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. BLALOCK A., HANLON C. R. The surgical treatment of complete transposition of the aorta and the pulmonary artery. Surg Gynecol Obstet. 1950 Jan;90(1):1-15, illust. [PubMed] [Google Scholar]
  2. Danielson G. K., Mair D. D., Ongley P. A., Wallace R. B., McGoon D. C. Repair of transposition of the great arteries of transposition of venous return. Surgical considerations and results of operation. J Thorac Cardiovasc Surg. 1971 Jan;61(1):96–103. [PubMed] [Google Scholar]
  3. Froysaker T. Anomalies of the superior vena caval flow pattern in patients with tricuspid insufficiency. Scand J Thorac Cardiovasc Surg. 1972;6(3):234–245. doi: 10.3109/14017437209134805. [DOI] [PubMed] [Google Scholar]
  4. Kalmanson D., Veyrat C., Chiche P. Le retour veineux droit enregistré par voie transcutanée au niveau de la veine jugulaire interne chez le sujet normal. Interprétation physiologique des courbes. Bull Mem Soc Med Hop Paris. 1968;119(11):873–889. [PubMed] [Google Scholar]
  5. Kalmanson D., Veyrat C., Chiche P. Variations physiologiques du retour veineux enregistré par voie transcutanée au niveau de la veine jugulaire interne variations extra-respiratoires. Arch Mal Coeur Vaiss. 1969 Oct;62(10):1386–1403. [PubMed] [Google Scholar]
  6. MULLER O., SHILLINGFORD J. The blood flow in the right atrium and superior vena cava in tricuspid incompetence. Br Heart J. 1955 Apr;17(2):163–168. doi: 10.1136/hrt.17.2.163. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. MUSTARD W. T. SUCCESSFUL TWO-STAGE CORRECTION OF TRANSPOSITION OF THE GREAT VESSELS. Surgery. 1964 Mar;55:469–472. [PubMed] [Google Scholar]
  8. Quaegebeur J. M., Brom A. G. The trousers-shaped baffle for use in the Mustard operation. Ann Thorac Surg. 1978 Mar;25(3):240–242. doi: 10.1016/s0003-4975(10)63531-x. [DOI] [PubMed] [Google Scholar]
  9. Quaegebeur J. M., Rohmer J., Brom A. G. Revival of the Senning operation in the treatment of transposition of the great arteries. Preliminary report on recent experience. Thorax. 1977 Oct;32(5):517–524. doi: 10.1136/thx.32.5.517. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. SENNING A. Surgical correction of transposition of the great vessels. Surgery. 1959 Jun;45(6):966–980. [PubMed] [Google Scholar]
  11. Silove E. D., Taylor J. F. Haemodynamics after Mustard's operation for transposition of the great arteries. Br Heart J. 1976 Oct;38(10):1037–1046. doi: 10.1136/hrt.38.10.1037. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Sivaciyan V., Ranganathan N. Transcutaneous doppler jugular venous flow velocity recording. Circulation. 1978 May;57(5):930–939. doi: 10.1161/01.cir.57.5.930. [DOI] [PubMed] [Google Scholar]
  13. Stark J., Silove E. D., Taylor J. F., Graham G. R. Obstruction to systemic venous return following the Mustard operation for transposition of the great arteries. J Thorac Cardiovasc Surg. 1974 Nov;68(5):742–749. [PubMed] [Google Scholar]
  14. Stark J., de Leval M. R., Waterston D. J., Graham G. R., Bonham-Carter R. E. Corrective surgery of transposition of the great arteries in the first year of life. Results in 63 infants. J Thorac Cardiovasc Surg. 1974 May;67(5):673–681. [PubMed] [Google Scholar]
  15. Wyse R. K., Haworth S. G., Taylor J. F., Macartney F. J. Obstruction of superior vena caval pathway after Mustard's repair. Reliable diagnosis by transcutaneous Doppler ultrasound. Br Heart J. 1979 Aug;42(2):162–167. doi: 10.1136/hrt.42.2.162. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES