Abstract
Three hundred and fifteen transvenous pacing leads of various modern designs have been assessed over a period of three years. Of these, 103 were implanted in the atrium and 212 in the ventricle. Screw-in leads in the right atrial appendage and short tined leads in the ventricle have resulted in the virtual elimination of lead displacement, and a very low incidence of other lead related problems. In two lead systems it has been found advantageous to have both leads constructed of urethane.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bisping H. J., Kreuzer J., Birkenheier H. Three-year clinical experience with a new endocardial screw-in lead with introduction protection for use in the atrium and ventricle. Pacing Clin Electrophysiol. 1980 Jul;3(4):424–435. doi: 10.1111/j.1540-8159.1980.tb05251.x. [DOI] [PubMed] [Google Scholar]
- Brenner A. S., Wagner G. S., Anderson S. T., Rosati R. A., Morris J. J., Jr Transvenous, transmediastinal, and transthoracic ventricular pacing: a comparison after complete two-year follow-up. Circulation. 1974 Mar;49(3):407–414. doi: 10.1161/01.cir.49.3.407. [DOI] [PubMed] [Google Scholar]
- Brewster G. M., Evans A. L. Displacement of pacemaker leads--a 10-year survey. Br Heart J. 1979 Sep;42(3):266–270. doi: 10.1136/hrt.42.3.266. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Citron P., Smyth N. P., Kleinert M., Kahn A. R. Clinical experience with a new transvenous atrial lead. Chest. 1978 Feb;73(2):193–197. doi: 10.1378/chest.73.2.193. [DOI] [PubMed] [Google Scholar]
- Geddes J. S., Webb S. W., Clements I. P. Clinical experience with transvenous atrial pacing. Br Heart J. 1978 Jun;40(6):589–595. doi: 10.1136/hrt.40.6.589. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kleinert M., Bock M., Wilhemi F. Clinical use of a new transvenous atrial lead. Am J Cardiol. 1977 Aug;40(2):237–242. doi: 10.1016/0002-9149(77)90014-5. [DOI] [PubMed] [Google Scholar]
- Kruse I., Rydén L., Ydse B. Clinical and electrophysiological characteristics of a transvenous atrial lead. Br Heart J. 1979 Nov;42(5):595–602. doi: 10.1136/hrt.42.5.595. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mond H., Sloman G. The small-tined pacemaker lead--absence of dislodgement. Pacing Clin Electrophysiol. 1980 Mar;3(2):171–177. doi: 10.1111/j.1540-8159.1980.tb04326.x. [DOI] [PubMed] [Google Scholar]
- Moss A. J. Therapeutic uses of permanent pervenous atrial pacemakers: A review. J Electrocardiol. 1975;8(4):373–380. doi: 10.1016/s0022-0736(75)80013-6. [DOI] [PubMed] [Google Scholar]
- Parsonnet V., Bilitch M., Furman S., Fisher J. D., Escher D. J., Myers G., Cassady E. Early malfunction of transvenous pacemaker electrodes. A three-center study. Circulation. 1979 Sep;60(3):590–596. doi: 10.1161/01.cir.60.3.590. [DOI] [PubMed] [Google Scholar]
- Smyth N. P., Basu A. P., Bacos J. M., Massumi R. A., Keshishian J. M., Baker N. R. Permanent transvenous synchronous cardiac pacing. Chest. 1971 May;59(5):493–497. doi: 10.1378/chest.59.5.493. [DOI] [PubMed] [Google Scholar]
- Stertzer S. H., DePasquale N. P., Bruno M. S., Cohn L. J. Right ventricular apexangiography for precise placement of transvenous electrode catheters. Chest. 1976 Feb;69(2):222–223. doi: 10.1378/chest.69.2.222. [DOI] [PubMed] [Google Scholar]
- Sutton R., Citron P. Electrophysiological and haemodynamic basis for application of new pacemaker technology in sick sinus syndrome and atrioventricular block. Br Heart J. 1979 May;41(5):600–612. doi: 10.1136/hrt.41.5.600. [DOI] [PMC free article] [PubMed] [Google Scholar]