Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1977 Feb;39(2):198–202. doi: 10.1136/hrt.39.2.198

Experience with counterpulsation in cardiac surgical patients.

G H Smith, W E Morgan
PMCID: PMC483216  PMID: 836735

Abstract

At Sheffield Regional Cardiothoracic Unit, the AVCO intra-aortic balloon pump has been used on 25 occasions in 21 months. Of the 25 patients, 12 survived and left hospital. The procedure is particularly beneficial in patients who have suffered some failure of myocardial protection during operation and to those who are suffering from acute ischaemia or the sequelae of myocardial infarction. The place of preoperative counterpulsation is discussed. Patients with long-standing cardiac disease who have emergency surgery benefit less from counterpulsation. Those patients with chronic ischaemic damage to the heart have nothing to gain from the use of counterpulsation.

Full text

PDF
198

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Buckley M. J., Mundth E. D., Daggett W. M., Gold H. K., Leinbach R. C., Austen W. G. Surgical management of ventricular septal defects and mitral regurgitation complicating acute myocardial infarction. Ann Thorac Surg. 1973 Dec;16(6):598–609. doi: 10.1016/s0003-4975(10)65041-2. [DOI] [PubMed] [Google Scholar]
  2. Dunkman W. B., Leinbach R. C., Buckley M. J., Mundth E. D., Kantrowitz A. R., Austen W. G., Sanders C. A. Clinical and hemodynamic results of intraaortic balloon pumping and surgery for cardiogenic shock. Circulation. 1972 Sep;46(3):465–477. doi: 10.1161/01.cir.46.3.465. [DOI] [PubMed] [Google Scholar]
  3. Fixler D. E., Archie J. P., Ullyot D. J., Buckberg G. D., Hoffman J. I. Effects of acute right ventricular systolic hypertension on regional myocardial blood flow in anesthetized dogs. Am Heart J. 1973 Apr;85(4):491–500. doi: 10.1016/0002-8703(73)90493-6. [DOI] [PubMed] [Google Scholar]
  4. Gill C. C., Wechsler A. S., Newman G. E., Oldham H. N., Jr Augmentation and redistribution of myocardial blood flow during acute ischemia by intraaortic balloon pumping. Ann Thorac Surg. 1973 Nov;16(5):445–453. doi: 10.1016/s0003-4975(10)65018-7. [DOI] [PubMed] [Google Scholar]
  5. Kantrowitz A., Phillips S. J., Butner A. N., Tjonneland S., Haller J. D. Technique of femoral artery cannulation for phase-shift balloon pumping. J Thorac Cardiovasc Surg. 1968 Aug;56(2):219–220. [PubMed] [Google Scholar]
  6. Powell W. J., Jr, Daggett W. M., Magro A. E., Bianco J. A., Buckley M. J., Sanders C. A., Kantrowitz A. R., Austen W. G. Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption, and coronary blood flow in dogs. Circ Res. 1970 Jun;26(6):753–764. doi: 10.1161/01.res.26.6.753. [DOI] [PubMed] [Google Scholar]
  7. Scheidt S., Wilner G., Mueller H., Summers D., Lesch M., Wolff G., Krakauer J., Rubenfire M., Fleming P., Noon G. Intra-aortic balloon counterpulsation in cardiogenic shock. Report of a co-operative clinical trial. N Engl J Med. 1973 May 10;288(19):979–984. doi: 10.1056/NEJM197305102881901. [DOI] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES