Abstract
A calibration unit and a capillary-damped pick-up, of funnel type, intended for apex cardiograms and other non-invasive cardiac pulse curves are presented. The physical properties of a recording system, suitable for non-invasive cardiac diagnostic techniques, are reviewed. In 4 identical recording units consisting of a funnel with and without capillary damping, connected via air transmission to a transducer, the overamplification in the underdamped systems varied between 2-4 and 4-3, and in the capillary-damped systems between 1-1 and 1-2. The capillary damping gave an approximately linear relation between phase shift and frequency in the high frequency range with a calculated delay of about 4ms. The low frequency time constant in the systems varied between 1-9 and 4-6 s, depending on the amplifier setting used, which for sine curves of frequency 0-5 and 2 Hz means an apparent prematurity for their maxima and minima varying between 53 and 1 ms, this being larger with lower frequency time constants and lower frequency curves.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Broman H., Kvasnicka J., Liander B., Varnauskas E. A computerized system for optimal filtering of left ventricular pressure data. IEEE Trans Biomed Eng. 1975 Jul;22(4):287–292. doi: 10.1109/tbme.1975.324446. [DOI] [PubMed] [Google Scholar]
- Denef B., Popeye R., Geest H. D., Kesteloot H. On the clinical value of calibrated displacement apexcardiography. Circulation. 1975 Mar;51(3):541–551. doi: 10.1161/01.cir.51.3.541. [DOI] [PubMed] [Google Scholar]
- Johnson J. M., Siegel W., Blomqvist G. Characteristics of transducers used for recording the apexcardiogram. J Appl Physiol. 1971 Nov;31(5):796–800. doi: 10.1152/jappl.1971.31.5.796. [DOI] [PubMed] [Google Scholar]
- Kastor J. A., Aronow S., Nagle R. E., Garber T., Walker H. Air leaks as a source of distortion in apexcardiography. Chest. 1970 Feb;57(2):163–171. doi: 10.1378/chest.57.2.163. [DOI] [PubMed] [Google Scholar]
- Kesteloot H., Willems J., van Vollenhoven E. On the physical principles and methodology of mechanocardiography. Acta Cardiol. 1969;24(2):147–160. [PubMed] [Google Scholar]
- Nilsson K., Thulesius O. A combined microphone for simultaneous recording of pulse and heart sounds. Biomed Eng. 1973 Oct;8(10):424–passim. [PubMed] [Google Scholar]
- Reale A. Evaluation of the contractile state of the human heart from the first derivative of the apexcardiogram. Circulation. 1967 Dec;36(6):933–941. doi: 10.1161/01.cir.36.6.933. [DOI] [PubMed] [Google Scholar]
- Sutton G. C., Craige E. Quantitation of precordial movement. I. Normal subjects. Circulation. 1967 Mar;35(3):476–482. doi: 10.1161/01.cir.35.3.476. [DOI] [PubMed] [Google Scholar]
- Sutton G. C., Prewitt T. A., Craige E. Relationship between quantitated precordial movement and left ventricular function. Circulation. 1970 Feb;41(2):179–190. doi: 10.1161/01.cir.41.2.179. [DOI] [PubMed] [Google Scholar]