Abstract
In order to investigate the functional effects of mitral valve surgery, echocardiograms showing left ventricular dimension were recorded and digitised in 14 normal subjects and 129 patients after mitral valve surgery. Measurements were made of peak rate of increase of dimension (dD/dt) and duration of rapid filling, studies on left ventriculograms in 36 patients having shown close correlation between these values and changes in cavity volume. In 14 patients with mitral stenosis, peak dD/dt was reduced to 7-2 +/ 1-5 cm/s, and filling period prolonged to 330 +/- 65 ms, compared with normal (16-0 +/- 3-2 cm/s, and 160 +/- 50 ms, respectively), and after mitral valvotomy, these values improved significantly (10-4 +/- 2-7 cm/s and 245 +/- 55 ms). Characteristic abnormalities were found in 67 patients with mitral prostheses. Values for the Björk-Shiley (10-5 +/- 4-2 cm/s and 180 +/- 80 ms) and Hancock (10-3 +/- 3-7 cm/s, 245 +/- 80 ms) values were similar, and both superior to the Starr-Edwards (7-4 +/- 3-0 cm/s, 295 +/- 105 ms). Results after mitral valve repair in 30 cases were not significantly different from normal (14-4 +/- 5-0 cm/s, 170 +/- 50 ms). Values outside the 95 per cent confidence limits for the valve in question allowed diagnosis of value malfunction in 18 cases. The method is value in comparing different operative procedures and in following up patients after mitral valve surgery.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Burggraf G. W., Craige E. Echocardiographic studies of left ventricular wall motion and dimensions after valvular heart surgery. Am J Cardiol. 1975 Apr;35(4):473–480. doi: 10.1016/0002-9149(75)90829-2. [DOI] [PubMed] [Google Scholar]
- Bök K. Mitral valve replacement with the Björk-Shiley tilting disc valve. A clinical and haemodynamic study in patients with isolated mitral valve lesions. Scand J Thorac Cardiovasc Surg Suppl. 1974;(12):1–28. [PubMed] [Google Scholar]
- Edler I. Ultrasoundcardiography in mitral valve stenosis. Am J Cardiol. 1967 Jan;19(1):18–31. doi: 10.1016/0002-9149(67)90258-5. [DOI] [PubMed] [Google Scholar]
- Effert S. Pre- and postoperative evaluation of mitral stenosis by ultrasound. Am J Cardiol. 1967 Jan;19(1):59–65. doi: 10.1016/0002-9149(67)90262-7. [DOI] [PubMed] [Google Scholar]
- Feigenbaum H., Linback R. E., Nasser W. K. Hemodynamic studies before and after instrumental mitral commissurotomy. A reappraisal of the pathophysiology of mitral stenosis and the efficacy of mitral valvotomy. Circulation. 1968 Aug;38(2):261–276. doi: 10.1161/01.cir.38.2.261. [DOI] [PubMed] [Google Scholar]
- GOODALE F., Jr, SANCHEZ G., FRIEDLICH A. L., SCANNELL J. G., MYERS G. S. Correlation of pulmonary arteriolar resistance with pulmonary vascular changes in patients with mitral stenosis before and after valvulotomy. N Engl J Med. 1955 Jun 9;252(23):979–983. doi: 10.1056/NEJM195506092522303. [DOI] [PubMed] [Google Scholar]
- Gibson D. G., Brown D. Measurement of instantaneous left ventricular dimension and filling rate in man, using echocardiography. Br Heart J. 1973 Nov;35(11):1141–1149. doi: 10.1136/hrt.35.11.1141. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hultgren H., Hubis H., Shumway N. Cardiac function following mitral valve replacement. Am Heart J. 1968 Mar;75(3):302–312. doi: 10.1016/0002-8703(68)90086-0. [DOI] [PubMed] [Google Scholar]
- McIntosh C. L., Michaelis L. L., Morrow A. G., Itscoitz S. B., Redwood D. R., Epstein S. E. Atrioventricular valve replacement with the Hancock porcine xenograft: a five year clinical experience. Surgery. 1975 Dec;78(6):768–775. [PubMed] [Google Scholar]
- Miller H. C., Gibson D. G., Stephens J. D. Role of echocardiography and phonocardiography in diagnosis of mitral paraprosthetic regurgitation with Starr-Edwards prostheses. Br Heart J. 1973 Dec;35(12):1217–1225. doi: 10.1136/hrt.35.12.1217. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Morrow A. G., Oldham H. N., Elkins R. S., Braunwald E. Prosthetic replacement of the mitral valve. Preoperative and postoperative clinical and hemodynamic assessments in 100 patients. Circulation. 1967 May;35(5):962–979. doi: 10.1161/01.cir.35.5.962. [DOI] [PubMed] [Google Scholar]
- Prewitt T., Gibson D., Brown D., Sutton G. The 'rapid filling wave' of the apex cardiogram. Its relation to echocardiographic and cineangiographic measurements of ventricular filling. Br Heart J. 1975 Dec;37(12):1256–1262. doi: 10.1136/hrt.37.12.1256. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Reis R. L., Glancy D. L., O'Brien K., Epstein S. E., Morrow A. G. Clinical and hemodynamic assessments of fabric-covered Starr-Edwards prosthetic valves. J Thorac Cardiovasc Surg. 1970 Jan;59(1):84–91. [PubMed] [Google Scholar]
- Sandler H., Dodge H. T. The use of single plane angiocardiograms for the calculation of left ventricular volume in man. Am Heart J. 1968 Mar;75(3):325–334. doi: 10.1016/0002-8703(68)90089-6. [DOI] [PubMed] [Google Scholar]
- Venco A., Gibson D. G., Brown D. J. Relation between apex cardiogram and changes in left ventricular pressure and dimension. Br Heart J. 1977 Feb;39(2):117–125. doi: 10.1136/hrt.39.2.117. [DOI] [PMC free article] [PubMed] [Google Scholar]