Abstract
The effect of permanent pacing on chronic complete atrioventricular block complicated by cardiac failure was studied in 6 patients by measurement of indirect left atrial pressure 15 minutes after institution of pacing and again 3 to 12 months later. In addition, 21 patients with complete heart block and clinical plus radiological evidence of cardiac failure at the time of pacing 3 to 6 years earlier were also reviewed. Only 1 of 6 patients studied haemodynamically improved and 1 died in cardiac failure. Of 21 patients assessed clinically, 10 had improved and 8 had died after a mean follow-up of 53 months. In the absence of syncope, pacing was of little symptomatic benefit but still may be justified to prolong survival. Both studies indicated a particularly poor prognosis for patients known to have coronary artery disease. No reliable means were found of determining the prognosis in the individual patient with cardiac failure before pacing.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bernstein V., Rotem C. E., Peretz D. I. Permanent pacemakers: 8-year follow-up study. Incidence and management of congestive cardiac failure and perforations. Ann Intern Med. 1971 Mar;74(3):361–369. doi: 10.7326/0003-4819-74-3-361. [DOI] [PubMed] [Google Scholar]
- Bevegård S., Jonsson B., Karlöf I., Lagergren H., Sowton E. Effect of changes in ventricular rate on cardiac output and central pressures at rest and during exercise in patients with artificial pacemakers. Cardiovasc Res. 1967 Jan;1(1):21–33. doi: 10.1093/cvr/1.1.21. [DOI] [PubMed] [Google Scholar]
- Davidson D. M., Braak C. A., Preston T. A., Judge R. D. Permanent ventricular packing. Effect on long-term survival, congestive heart failure, and subsequent myocardial infarction and stroke. Ann Intern Med. 1972 Sep;77(3):345–351. doi: 10.7326/0003-4819-77-3-345. [DOI] [PubMed] [Google Scholar]
- Gobel F. L., Medina J. R., Guenter C. A., Wang Y. Immediate hemodynamic response of patients with atrioventricular block and cardiac failure to transvenous pacing. Circulation. 1969 Jan;39(1):64–71. doi: 10.1161/01.cir.39.1.64. [DOI] [PubMed] [Google Scholar]
- JUDGE R. D., WILSON W. S., SIEGEL J. H. HEMODYNAMIC STUDIES IN PATIENTS WITH IMPLANTED CARDIAC PACEMAKERS. N Engl J Med. 1964 Jun 25;270:1391–1395. doi: 10.1056/NEJM196406252702605. [DOI] [PubMed] [Google Scholar]
- LEVINE S. A., MILLER H., PENTON G. B. Some clinical features of complete heart block. Circulation. 1956 Jun;13(6):801–824. doi: 10.1161/01.cir.13.6.801. [DOI] [PubMed] [Google Scholar]
- SAMET P., BERNSTEIN W. H., MEDOW A., NATHAN D. A. EFFECT OF ALTERATIONS IN VENTRICULAR RATE ON CARDIAC OUTPUT IN COMPLETE HEART BLOCK. Am J Cardiol. 1964 Oct;14:477–482. doi: 10.1016/0002-9149(64)90031-1. [DOI] [PubMed] [Google Scholar]
- SOWTON E. HAEMODYNAMIC STUDIES IN PATIENTS WITH ARTIFICIAL PACEMAKERS. Br Heart J. 1964 Nov;26:737–746. doi: 10.1136/hrt.26.6.737. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Siddons H. Deaths in long-term paced patients. Br Heart J. 1974 Dec;36(12):1201–1209. doi: 10.1136/hrt.36.12.1201. [DOI] [PMC free article] [PubMed] [Google Scholar]