Abstract
BACKGROUND--Measurement of variables of metabolic gas exchange during exercise is widely used to assess the severity of heart failure. The variables derived however, are potentially dependent on motivation of the patient and duration of exercise. METHODS--The data from exercise tests in 23 patients with exertional breathlessness were analysed to derive the following three common indices of exercise tolerance: anaerobic threshold, extrapolated maximum oxygen consumption, and the ventilation to carbon dioxide production slope. The data were reanalysed with the data points from the first 90% of subsequent exercise, the first 75%, and finally the data up to the point where a respiratory gas exchange ratio of 1 was reached. RESULTS--The mean (SEM) anaerobic threshold was lower when computed from 90% of the data points than from 100% (13.2 (1.0) ml/kg/min v 12.5 (1.0), p < 0.001) and lower still from 75% (11.4 (0.7), p = 0.006 v 90%). Extrapolated maximum oxygen consumption was unchanged when computed from 90% of the data, but higher when computed from 75% (25.4 (2.1) ml/kg/min at 100% v 28.6 (2.1) at 75%, p < 0.001). The slope of the ventilation to carbon dioxide production ratio became progressively shallower measured from 90% and 75% of eventual exercise: 32.3 (1.5) from 100% v 30.0 (1.5) from 90%, p < 0.001; and 28.3 from 75%, p < 0.001 v 90%. At a respiratory gas exchange ratio of 1, extrapolated oxygen consumption was unchanged from the final calculation, anaerobic threshold was lower than at 100% of exercise (11.8 (0.9), p = 0.005) and the ventilation to carbon dioxide production slope was shallower (27.5 (1.4), p < 0.001). CONCLUSIONS--Anaerobic threshold tends to overestimate severity of exercise limitation and extrapolated maximum oxygen consumption and the ventilation to carbon dioxide production slope tend to underestimate severity. Extrapolated maximum oxygen consumption is the most reliable of the three measures, and is independent of effort provided that patients are encouraged to exercise to the point where the respiratory gas exchange ratio exceeds 1.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Buller N. P., Poole-Wilson P. A. Extrapolated maximal oxygen consumption: a new method for the objective analysis of respiratory gas exchange during exercise. Br Heart J. 1988 Feb;59(2):212–217. doi: 10.1136/hrt.59.2.212. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Buller N. P., Poole-Wilson P. A. Mechanism of the increased ventilatory response to exercise in patients with chronic heart failure. Br Heart J. 1990 May;63(5):281–283. doi: 10.1136/hrt.63.5.281. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Clark A. L., Coats A. J. Exercise hyperventilation chronic congestive heart failure and its relation to functional capacity and hemodynamics. Am J Cardiol. 1993 Apr 15;71(11):1007–1008. doi: 10.1016/0002-9149(93)90927-5. [DOI] [PubMed] [Google Scholar]
- Clark A. L., Poole-Wilson P. A., Coats A. J. Relation between ventilation and carbon dioxide production in patients with chronic heart failure. J Am Coll Cardiol. 1992 Nov 15;20(6):1326–1332. doi: 10.1016/0735-1097(92)90244-h. [DOI] [PubMed] [Google Scholar]
- Cowley A. J., Fullwood L., Stainer K., Hampton J. R. Exercise tolerance in patients with heart failure--how should it be measured? Eur Heart J. 1991 Jan;12(1):50–54. doi: 10.1093/oxfordjournals.eurheartj.a059824. [DOI] [PubMed] [Google Scholar]
- Davies N. J., Denison D. M. The measurement of metabolic gas exchange and minute volume by mass spectrometry alone. Respir Physiol. 1979 Feb;36(2):261–267. doi: 10.1016/0034-5687(79)90029-x. [DOI] [PubMed] [Google Scholar]
- Franciosa J. A., Baker B. J., Seth L. Pulmonary versus systemic hemodynamics in determining exercise capacity of patients with chronic left ventricular failure. Am Heart J. 1985 Oct;110(4):807–813. doi: 10.1016/0002-8703(85)90461-2. [DOI] [PubMed] [Google Scholar]
- Lipkin D. P., Perrins J., Poole-Wilson P. A. Respiratory gas exchange in the assessment of patients with impaired ventricular function. Br Heart J. 1985 Sep;54(3):321–328. doi: 10.1136/hrt.54.3.321. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lipkin D. P., Perrins J., Poole-Wilson P. A. Respiratory gas exchange in the assessment of patients with impaired ventricular function. Br Heart J. 1985 Sep;54(3):321–328. doi: 10.1136/hrt.54.3.321. [DOI] [PMC free article] [PubMed] [Google Scholar]
- MITCHELL J. H., SPROULE B. J., CHAPMAN C. B. The physiological meaning of the maximal oxygen intake test. J Clin Invest. 1958 Apr;37(4):538–547. doi: 10.1172/JCI103636. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Metra M., Dei Cas L., Panina G., Visioli O. Exercise hyperventilation chronic congestive heart failure, and its relation to functional capacity and hemodynamics. Am J Cardiol. 1992 Sep 1;70(6):622–628. doi: 10.1016/0002-9149(92)90202-a. [DOI] [PubMed] [Google Scholar]
- Metra M., Raddino R., Dei Cas L., Visioli O. Assessment of peak oxygen consumption, lactate and ventilatory thresholds and correlation with resting and exercise hemodynamic data in chronic congestive heart failure. Am J Cardiol. 1990 May 1;65(16):1127–1133. doi: 10.1016/0002-9149(90)90326-v. [DOI] [PubMed] [Google Scholar]
- Rodrigues E. A., Maddahi J., Brown H., Pantaleo N., Freeman M., Koerner S., Waxman A., Berman D. S. Responses of left and right ventricular ejection fractions to aerobic and anaerobic phases of upright and supine exercise in normal subjects. Am Heart J. 1989 Aug;118(2):319–324. doi: 10.1016/0002-8703(89)90192-0. [DOI] [PubMed] [Google Scholar]
- Simonton C. A., Higginbotham M. B., Cobb F. R. The ventilatory threshold: quantitative analysis of reproducibility and relation to arterial lactate concentration in normal subjects and in patients with chronic congestive heart failure. Am J Cardiol. 1988 Jul 1;62(1):100–107. doi: 10.1016/0002-9149(88)91372-0. [DOI] [PubMed] [Google Scholar]
- Sullivan M. J., Higginbotham M. B., Cobb F. R. Exercise training in patients with chronic heart failure delays ventilatory anaerobic threshold and improves submaximal exercise performance. Circulation. 1989 Feb;79(2):324–329. doi: 10.1161/01.cir.79.2.324. [DOI] [PubMed] [Google Scholar]
- Sullivan M. J., Higginbotham M. B., Cobb F. R. Increased exercise ventilation in patients with chronic heart failure: intact ventilatory control despite hemodynamic and pulmonary abnormalities. Circulation. 1988 Mar;77(3):552–559. doi: 10.1161/01.cir.77.3.552. [DOI] [PubMed] [Google Scholar]
- Whipp B. J. Ventilatory control during exercise in humans. Annu Rev Physiol. 1983;45:393–413. doi: 10.1146/annurev.ph.45.030183.002141. [DOI] [PubMed] [Google Scholar]
- Wilson J. R., Mancini D. M., Ferraro N., Egler J. Effect of dichloroacetate on the exercise performance of patients with heart failure. J Am Coll Cardiol. 1988 Dec;12(6):1464–1469. doi: 10.1016/s0735-1097(88)80010-x. [DOI] [PubMed] [Google Scholar]
- Yeh M. P., Gardner R. M., Adams T. D., Yanowitz F. G., Crapo R. O. "Anaerobic threshold": problems of determination and validation. J Appl Physiol Respir Environ Exerc Physiol. 1983 Oct;55(4):1178–1186. doi: 10.1152/jappl.1983.55.4.1178. [DOI] [PubMed] [Google Scholar]