Abstract
Introduction.
Secondhand smoke remains a health concern for individuals living in multiunit housing, where smoke has been shown to easily transfer between units. Building-wide smoke-free policies are a logical step for minimizing smoke exposure in these settings. This evaluation sought to determine whether buildings with smoke-free policies have less secondhand smoke than similar buildings without such policies. Furthermore, this study assessed potential secondhand smoke transfer between apartments with and without resident smokers.
Methods.
Fine particulate matter (PM2.5), airborne nicotine, and self-reported smoking activity were recorded in 15 households with resident smokers and 17 households where no one smoked in 5 Boston Housing Authority developments. Of these, 4 apartment pairs were adjacent apartments with and without resident smokers. Halls between apartments and outdoor air were also monitored to capture potential smoke transfer and to provide background PM2.5 concentrations.
Results.
Households within buildings with smoke-free policies showed lower PM2.5 concentrations compared to buildings without these policies (median: 4.8 vs 8.1 µg/m3). Although the greatest difference in PM2.5 between smoking-permitted and smoke-free buildings was observed in households with resident smokers (14.3 vs 7.0 µg/m3), households without resident smokers also showed a significant difference (5.1 vs 4.0 µg/m3). Secondhand smoke transfer to smoke-free apartments was demonstrable with directly adjacent households.
Conclusion.
This evaluation documented instances of secondhand smoke transfer between households as well as lower PM2.5 measurements in buildings with smoke-free policies. Building-wide smoke-free policies can limit secondhand smoke exposure for everyone living in multiunit housing.
Introduction
The Surgeon General reports that there is no risk-free level of exposure to secondhand smoke and that it can cause premature death and disease in nonsmokers.1 Previous research has demonstrated that levels of fine particulate matter (PM2.5) in the air are three times higher in smoke-permitted homes than in smoke-free homes and that confining smoking to certain living spaces does not offer protection from secondhand smoke.2–4 Children living in multiunit housing have more exposure to secondhand smoke than those living in free-standing homes.5 Furthermore, people living in multiunit housing have little control over their exposure to secondhand smoke since much of the air entering their apartments originates somewhere else in the building.6,7 Low-income urban populations are especially susceptible to these issues. For example, in Boston, both the prevalence of smoking (34.4% vs. 20.6%) and current asthma symptoms (19.2% vs. 9.0%) are significantly higher among public housing residents compared with other residents.8 Therefore, interventions that specifically influence the public housing setting could address health disparities. Digenis-Bury et al.8 demonstrated that public housing residents in Boston were more likely to have children, less likely to have completed high school or college, and more likely to be unemployed or unable to work compared with other Boston residents. Models controlling for gender, age, race/ethnicity, level of education, and income revealed higher rates of hypertension, asthma, and diabetes among Boston public housing residents (prevalence odds ratio: 1.5–1.8). Many of these disparities can exacerbate vulnerability to secondhand smoke exposure.
In September 2012, in an effort to protect vulnerable residents from exposure to secondhand smoke, the Boston Housing Authority (BHA) implemented a smoke-free policy throughout its entire public housing portfolio, which houses 27,000 people in 14,000 units in 64 developments. The policy development process took place over several years, entailing resident involvement and signing of lease addenda acknowledging the policy change. Informational summits were held, residents were surveyed about their level of support for the policy change, and free on-site tobacco cessation counseling was offered to public housing residents and staff. In part because Americans spend the majority of their time in their own homes, smoke-free policies can have meaningful impact on smoke exposure and may thus experience greater reductions in personal exposure.1,9,10
Multiple environmental markers exist for the assessment of secondhand smoke; fine particulate matter is one measurable environmental marker, which can estimate secondhand smoke exposure magnitude, duration, and frequency.1,11 Aerosol monitors measure these PM2.5 particles, which have diameters less than 2.5 µm and are easily drawn deep into the lungs where they can damage the cardiovascular system.12,13 These monitors have been used to investigate secondhand smoke in multiunit housing communities.14,15 The specificity of nicotine sampling, conducted alongside aerosol monitoring, supports the conclusion that observed particulates originated primarily from tobacco smoke in settings with active smoking.4 Studies with real-time aerosol monitoring and nicotine sampling taking place concurrently have validated aerosol monitoring as a method of measuring secondhand smoke.16 The BHA smoke-free policy presents a unique ecological opportunity for assessing changes in indoor air quality.
The purpose of this evaluation is two-fold: to assess whether there are measurable differences in aerosol levels in BHA buildings with and without smoke-free policies in place and to compare coincident and temporal trends in aerosol levels in the homes of smoking and nonsmoking residents in order to understand how secondhand smoke may transfer between them. This cross-sectional analysis will further describe how smoke-free policies benefit both smoking and nonsmoking populations.
Methods
Sampling Plan
Prior to the portfolio-wide smoke-free policy implementation in September 2012, multiple smoke-free pilot sites were in place. We identified five BHA developments from which we could create pairs of comparable building type (3-story walk-up, mid-rise, and high-rise) with and without smoke-free policies in place prior to September 2012. One development had 3-story walk-up entry entryways with and without smoke-free policies in place prior to September 2012 and served as its own paired grouping. Although two midrise developments were not subject to the pending smoke-free policy due to separate funding and management structures, one already had a building-wide smoke-free policy in place and the other did not. The remaining two high-rise developments transitioned to having a building-wide smoke-free policy as of September 30, 2012 (Table 1). All sampling occurred from August to December 2012, and each sampling event was categorized according to the policy of record on the date of sampling. Household units within each development were selected based on volunteer interest (provided they were adults who comprehended English). We sought to enroll 40 households—20 with and 20 without smoking residents—from these five housing developments and paired them by proximity. Ideal pairs were directly adjacent, but nonadjacent neighbor pairs (with and without smoking residents) who shared a hallway or stairwell were also included. On six occasions, unoccupied units were used in place of nonsmoking households if these locations afforded closer proximity to a household with smoking residents. A smoking household was defined as one that contained at least one smoking resident who agreed to participate in data collection regardless of his or her development’s smoke-free policy. These households were designated smoking whether or not the resident smoker(s) abided by the development’s smoke-free policy. A nonsmoking household was defined as one that contained no smokers residing in the home as reported by the study participant, regardless of the development’s smoke-free policy.
Table 1.
Characteristics of Areas Sampled for Particulate Matter
Smoke-free policy | Development | Building type | Residential type | Proximity | Area sampled for particulate matter | |||
---|---|---|---|---|---|---|---|---|
Units by resident smoking status | Public areas | |||||||
Yes | A | 3-Story | Family | Nonadjacent | Smoker | Nonsmoker | Hall | Outdoor |
Yes | A | 3-Story | Family | Nonadjacent | Smoker | Unoccupied unit | Hall | Outdoor |
Yes | A | 3-Story | Family | Nonadjacent | Smoker | Unoccupied unit | Hall | Outdoor |
No | A | 3-Story | Family | Nonadjacent | Smoker | Unoccupied unit | Hall | Outdoor |
No | B | High-rise | Elderly/disabled | Nonadjacent | Smoker | Nonsmoker | Hall | Outdoor |
No | B | High-rise | Elderly/disabled | Nonadjacent | Smoker | Unoccupied unit | Hall | Outdoor |
No | B | High-rise | Elderly/disabled | Nonadjacent | Smoker | Nonsmoker | Hall | Outdoor |
No | C | High-rise | Elderly/disabled | Adjacent | Smoker | Unoccupied unit | Hall | Outdoor |
No | C | High-rise | Elderly/disabled | Nonadjacent | Smoker | Nonsmoker | Hall | Outdoor |
No | C | High-rise | Elderly/disabled | Nonadjacent | Smoker | Unoccupied unit | Hall | Outdoor |
Yes | D | Mid-rise | Family | Adjacent | Smoker | Nonsmoker | Hall | Outdoor |
Yes | D | Mid-rise | Family | Adjacent | Smoker | Nonsmoker | Hall | – |
Yes | D | Mid-rise | Family | Nonadjacent | Smoker | Nonsmoker | Hall | Outdoor |
No | E | Mid-rise | Family | Adjacent | Smoker | Nonsmoker | Hall | Outdoor |
No | E | Mid-rise | Family | Nonadjacent | Smoker | Nonsmoker | Hall | Outdoor |
No | E | Mid-rise | Family | Nonadjacent | – | Two nonsmokers | Hall | Outdoor |
Developments B and C transitioned to having a building-wide smoke-free policy as of September 30, 2012.
Participant Recruitment
Participants were recruited through community meetings, community liaisons, and door knocking. Each participant gave oral consent to participate in the air quality study, and our confidentiality agreement included protecting residents from being reported to BHA even if they had smoked in designated smoke-free spaces. Participation included keeping a resident log of events, which would affect air quality (e.g., cooking, open windows, lit candles or cigarettes, etc.) during the air sampling period and allowing both the PM2.5 monitor and passive nicotine sampler to be placed in the home for a 72-hr sampling period. Participants received $25 gift cards as compensation. Approval of human subjects research was granted by the Boston University Medical Center Institutional Review Board.
Equipment
Co-calibrated DUSTTRAK, DUSTTRAK II, and SidePak aerosol monitors (models 8520, 8530, and AM510, TSI, Inc.) were used to measure PM2.5 concentrations in the air. The aerosol monitors were set to record measurements (PM2.5 concentration in mg/m3) at 1-min intervals, which were the average of the previous 60 s of sampling. Manufacturer-specified flow rates were used: 1.7L/min for model 8520, 1.0L/min for model 8530, and 1.7L/min for the SidePak model. We used the size selective inlets provided by the manufacturer of the DUSTTRAK and SidePak. We conducted side-by-side comparisons between all the devices which were used in this study prior to them being deployed. We recorded PM2.5 concurrently for 72hr in each of four settings: smoking home, nonsmoking or unoccupied neighboring unit, common entryways or hallway, and outdoors sample. Monitors were connected to an electrical source and placed in the primary living space of the home away from windows or vents. If a table or shelf was unavailable, static-free plastic tubing 4 ft in length was attached to the monitor inlet and affixed to a position closer to breathing level. In all instances, the monitor keypad was locked during the sampling period to prevent tampering or accidental termination.
We placed passive nicotine samplers in all of these same settings to confirm the presence of tobacco smoke. Both positive (double concurrent sampling) and negative (unopened sampler) controls were submitted alongside the other environmental samplers for processing at the University of California at Berkeley.
Data Analysis
Particulate matter aerosol data were downloaded from the PM2.5 monitors using TSI TrakPro software (version 4.5.1.0, TSI Inc.) and imported into SAS (version 9.1.3, SAS Institute), where they were analyzed alongside resident log information. PM2.5 concentration values were limited to those between 0 µg/m3 and the 99th percentile in order to eliminate extreme outliers. Our calibration factors (0.366 for indoor PM2.5 data and 0.635 for outdoor PM2.5 data) were based on a separate dataset of concurrent aerosol monitoring and gravimetric analysis in BHA public housing.15 These calibration factors control for differences in humidity, which affects the particle size distribution in these settings.
Data from these monitors were used to make four analyses: (a) comparisons of median PM2.5 levels between smoke-permitted and smoke-free buildings, (b) comparisons of median PM2.5 levels between smoker-occupied and nonsmoker-occupied settings, (c) correlations of nicotine concentrations with PM2.5 levels to support evidence that PM2.5 levels contained tobacco-related contamination, and (d) real-time instances of smoke transfer between smoker-occupied and nonsmoker-occupied households.
The primary outcome of interest was the median PM2.5 level in a given setting.14 We tested whether levels differed between smoke-permitted and smoke-free buildings. Buildings were considered smoke-free if that was their policy of record at the time of sampling. We also compared PM2.5 levels in homes with and without smoking residents during hours in which smoking participants reported smoking occurrences on their resident log compared with hours in which no smoking occurrences were reported. We used the Wilcoxon–Mann–Whitney test to determine whether these nonparametrically distributed sample populations were significantly different from each other.
Real-time instances of smoke transfer from smoking to nonsmoking households were initially explored graphically. This transpired when the resident log documented cigarette use in the smoking household at a time corresponding with increased PM2.5 measurements, and when minutes later, an increase in PM2.5 levels was measured in the home without smoking residents in the absence of any other type of documented air contaminant. We also assessed air quality in common entryways or shared hallways where smoking was not permitted and expected to see intermediate measurements between those recorded in the homes of smoking and nonsmoking residents.
Finally, we used passive nicotine samplers to absorb ambient nicotine in all of the same settings where the PM2.5 monitors were placed in order to confirm that higher levels of particulate matter in the air were correlated with elevated environmental tobacco smoke levels. Nicotine concentrations were calculated based on the duration of deployment. We used the Spearman rank correlation coefficient to determine whether PM2.5 levels correlated with nicotine concentration absorbed by passive nicotine samplers, where r s = 1 is perfect positive correlation.
Results
PM2.5 levels were sampled from 32 households in 5 BHA developments; 15 of these were inhabited by smokers, 11 by nonsmokers, and 6 were unoccupied units used as nonsmoking proxies (Table 1). Households with smoking residents averaged 2.0 inhabitants including 0.5 children per unit with a median age of 38.5 years (range: 1–74). Households without smoking residents averaged 1.6 inhabitants including 0.5 children per unit with a median age of 24.5 years (range: 5–76). Both household types had an average of three-and-a-half rooms (excluding kitchens and bathrooms). Continuous PM2.5 data were collected for an average of 78.1hr in smoking households and 77.0hr in nonsmoking households.
The five housing developments included two high-rise, two mid-rise, and one 3-story walk-up building. Four of the 16 sampling pairs included a nonsmoking or unoccupied unit directly adjacent to the enrolled smoking household (Table 1). One sampling pair in Development D did not include an outdoor site due to equipment malfunction. In one sampling pair in Development E, an eligible smoking participant could not be recruited, so instead an additional nonsmoking household was included within this smoke-permitted building. These values contributed to the pooled nonsmoking PM2.5 samples but could not be used to inform us about smoke transfer between households. Median PM2.5 concentrations for each sampled setting revealed that households with resident smokers had the highest levels (10.6 µg/m3), followed by outdoor spaces (8.3 µg/m3), hallways/shared entryways (5.1 µg/m3), and lastly nonsmoking/unoccupied units (4.8 µg/m3); these distributions were significantly different (p < .0001).
Comparisons of Median PM2.5 Levels Between Smoke-Permitted and Smoke-Free Buildings
Figure 1 shows the differences in PM2.5 distributions between buildings with smoke-permitted and smoke-free policies in place. Pooled PM2.5 data from both smoking and nonsmoking/unoccupied units showed buildings with smoke-free policies in place had lower PM2.5 concentrations at each quartile, with a median of 4.8 µg/m3 compared with 8.1 µg/m3 in buildings with smoke-permitted policies. The differences are most striking at the 75th percentile: 10.2 µg/m3 compared with 19.8 µg/m3.
Figure 1.
PM2.5 distributions by smoke-free policy.
Comparisons of Median PM2.5 Levels Between Smoker-Occupied and Nonsmoker-Occupied Settings
These differences were also demonstrated when apartments with smoking residents and those without smoking residents were pooled separately. Median PM2.5 concentrations in apartments with smoking residents were lower in buildings with smoke-free policies (14.3 vs. 7.0 µg/m3). Unoccupied apartments or those with no resident smokers also had lower median PM2.5 concentrations in buildings with smoke-free policies in place (5.1 vs. 4.0 µg/m3). All differences were significant using the Wilcoxon-Mann-Whitney test (p < .0001).
Median PM2.5 levels measured in both the smoking and adjacent nonsmoking households during hours in which the participant smoker reported smoking compared with hours during which no smoking was reported showed significant differences (Table 2). The households with smoking participants demonstrated sharp differences in PM2.5 levels between those hours with reported smoking (29.6 µg/m3) and those without (9.2 µg/m3, p < .0001). Nonsmoking households located directly adjacent to these smoking participants also experienced differences in PM2.5 levels during hours in which their smoking neighbor reported smoking (5.9 µg/m3) compared with hours in which no smoking was reported (3.3 µg/m3, p < .0001). This relationship is not observed with nonadjacent pairs of smoking and nonsmoking/unoccupied households, in which a small, statistically significant difference in PM2.5 levels was observed during smoking hours (4.0 µg/m3) and nonsmoking hours (4.4 µg/m3). This opposing relationship explains the nonsignificant difference in PM2.5 levels when all nonsmokers are combined. Common areas also showed a significant, but small magnitude difference in PM2.5 levels in hours with reported smoking (5.9 µg/m3) compared with hours in which no smoking was reported (5.1 µg/m3).
Table 2.
Comparisons of PM2.5 (µg/m3) Aerosol Levels Measured During Hours When Smokers Self-Reported Smoking or Nonsmoking
Area observed | Smoking or nonsmoking hours reported by smoker | 25th Percentile | Median | 75th Percentile | 90th Percentile | pa |
---|---|---|---|---|---|---|
Smokers | Nonsmoking hours | 3.7 | 9.2 | 23.4 | 92.6 | <.0001 |
Smoking hours | 8.1 | 29.6 | 113.1 | 230.2 | ||
All nonsmokers | Nonsmoking hours | 2.6 | 4.4 | 7.7 | 15.0 | .581 |
Smoking hours | 2.2 | 4.0 | 8.1 | 16.1 | ||
Nonsmokers living adjacent to smoker | Nonsmoking hours | 2.2 | 3.3 | 8.8 | 27.1 | <.0001 |
Smoking hours | 2.6 | 5.9 | 24.2 | 64.8 | ||
Nonsmokers not living adjacent to smoker | Nonsmoking hours | 2.9 | 4.4 | 7.7 | 12.4 | <.0001 |
Smoking hours | 2.2 | 4.0 | 7.7 | 12.1 | ||
Common areas | Nonsmoking hours | 2.9 | 5.1 | 8.8 | 15.7 | <.0001 |
Smoking hours | 2.9 | 5.9 | 10.2 | 16.1 |
aWilcoxon–Mann–Whitney test.
Correlations of Nicotine Concentrations With PM2.5 Levels to Support Evidence That PM2.5 Levels Contained Tobacco-Related Contamination
Smoking households had the highest mean nicotine concentrations (3.07 µg/m3) compared with common areas (0.43 µg/m3), nonsmoking/unoccupied households (0.04 µg/m3), and outdoor settings (0.02 µg/m3, which was the lowest concentration detected by these nicotine samplers; data not shown in tables). Higher PM2.5 levels were correlated with higher nicotine concentrations in all sampling settings (r s = .58, p < .0001), but particularly so within smoking households (r s = .90, p < .0001).
Real-Time Instances of Smoke Transfer Between Smoker-Occupied and Nonsmoker-Occupied Households
In Figure 2, we display an instance consistent with tobacco smoke from a smoking participant infiltrating an adjacent unoccupied unit some minutes later. Arrows indicate times at which smoking was self-reported, and the unoccupied unit’s PM2.5 levels show a steady increase shortly thereafter. There was no other known source of air contamination in this unoccupied unit. Note the different y-axis scales of the smoking and nonsmoking household PM2.5 levels. The smoking household’s PM2.5 levels of higher amplitude show more dynamic response to the smoking events, with higher peaks followed by sharper declines. In contrast, the unoccupied unit shows gradual increases at lower amplitude, which are sustained longer. Specific instances such as these with clear occurrences of smoke transfer corroborated by resident log were rare.
Figure 2.
Overlay of two real-time PM2.5 axes: levels in smoker’s unit and adjacent unoccupied unit.
Discussion
This evaluation demonstrates that indoor air pollution is lower in apartments covered by building-wide smoke-free policies compared to apartments in buildings without these policies. These findings lend support to the potential effectiveness of residential smoke-free policies in multiunit housing and bolster existing evidence indicating that smoke cannot be confined to designated smoking areas within buildings. Segregating smokers and nonsmokers by entire buildings with different smoking policies is not a favorable alternative to removing the source throughout the property because it increases the smoke exposure to both smoking and nonsmoking residents in those smoking-permitted buildings.
In buildings with smoke-free policies in place, households with resident smokers had over 50% lower median PM2.5 concentrations. This difference suggests that smoke-free policies may reduce indoor smoking and exposure to secondhand smoke. Differences were even more striking at the higher percentiles, consistent with the episodic nature of smoking-associated increases in secondhand smoke-related pollutants. Even small magnitude changes in annual aerosol exposure (i.e., 10 µg/m3) are associated with health impacts and increased risk of all-cause mortality.18–21 Of note, the U.S. Environmental Protection Agency’s health-based PM2.5 annual standard is 12 µg/m3.22 The 3-day sampling period medians in this evaluation cannot be directly correlated with annual means, but it is possible that these differences cumulated over a longer time period might have meaningful health implications.
We attribute the higher PM2.5 concentrations in smoking-permitted households directly to tobacco smoke. Ambient nicotine concentrations showed the strongest correlation in smoking homes where aerosol levels were also the highest. Using self-reported instances of smoking to classify each hour as a “smoking hour” or “nonsmoking hour” was another measure of the direct impact smoking had on aerosol levels. Smoking households, directly adjacent units, and shared hallways or stairwells all showed significantly higher aerosol levels during hours in which smoking was reported. Classifying a whole hour as smoking or nonsmoking created a conservative estimate for imprecise reporting of the time of smoking events and built in a “lag time” for smoke to transfer to other areas.
Similar to previous studies that measured PM2.5 in multiunit housing, we observed significantly higher aerosol levels in smoking compared with nonsmoking households.14,15 These apartments with resident smokers had more than twice the PM2.5 concentration of nonsmoking/unoccupied units regardless of whether some of these smokers may have chosen to smoke outside their homes. Our findings, embedded in building-wide policy differences, underscore the importance of building-wide smoke-free policies since households with self-imposed smoke-free policies in smoking-permitted buildings demonstrated higher levels of PM2.5 than did nonsmoking households in buildings with smoke-free policies in place. We attribute this, in part, to smoke transfer within the building.
We acknowledge that our survey of air quality was limited to concurrent sampling in four settings for each sampling period in the five housing developments. We cannot account for contaminants that may have transferred from a nonparticipating smoker in the same vicinity as our grouped smoking/nonsmoking pairs. Therefore, evidence of peaks in PM2.5 in nonsmoking/unoccupied units in response to documented smoking activity represents an underestimate of smoke transfer. We relied on self-reported logs of smoking activity, which is susceptible to variably precise record-keeping, which we addressed by broadening each smoking event to an hour. Although we chose building pairs that were of similar building style and construction, there are still inter-building differences which account for changes in how air is transferred between spaces. Additionally, sampling occurred during warm and cold weather periods of variable humidity, which may affect monitor performance and human behavior (e.g., opening/closing windows, smoking frequency, etc.). Furthermore, this cross-sectional survey has limited generalizability due to its use of a convenience sample and the fact that PM2.5 itself is not specific to secondhand smoke.
Despite advances in smoke-free policy adoption in public places, exposure to secondhand smoke in the home continues to impose a risk to vulnerable populations who live in multiunit housing. The department of Housing and Urban Development has urged housing authorities to adopt complete smoke-free policies across the country, and BHA is one of the first large housing authorities to implement this far-reaching policy recommendation.23 The implications of this evaluation are that the implementation of a smoke-free policy would reduce secondhand smoke in multiunit housing.
Funding
The project was supported in part by the cooperative agreement with the Centers for Disease Control and Prevention (#1U58DP002478-01). Portions of this project’s work involve the Communities Putting Prevention to Work initiative supported by CDC funding. DEL was supported by grants from the Flight Attendants Medical Research Institute, the Harvard School of Public Health/National Cancer Institute (P50-CA148596), and the National Heart, Lung, and Blood Institute (R01-HL112212).
Declaration of Interests
None declared.
Acknowledgments
The authors would like to acknowledge the Boston Public Health Commissions environmental health officers for assistance with using the DUSTTRAK monitors, the Boston Housing Authority for support in recruiting participants throughout the five developments, Brian King for technical support throughout the study period, Shannon O’Malley and Rashida Taher of the Boston Public Health Commission for data collection assistance, and Charles Perrino for nicotine sampler analysis. The findings and conclusions in this paper are those of the authors and do not necessarily represent the funders’ official positions.
References
- 1. USDHHS. The health consequences of involuntary exposure to tobacco smoke: a report of the surgeon general. Atlanta, GA: Department of Health and Human Services; 2006. http://www.surgeongeneral.gov/library/reports/secondhandsmoke/fullreport.pdf [PubMed] [Google Scholar]
- 2. Bohac DL, Hewett MJ, Kapphahn KI, et al. Secondhand smoke exposure in the nonsmoking section: how much protection? Nicotine Tob Res. 2013;15:1265–1272. 10.1093/ntr/nts263 [DOI] [PubMed] [Google Scholar]
- 3. Cains T, Sannata S, Poulos R, Ferson MJ, Stewart BW. Designated “no smoking” areas provide from partial to no protection from environmental tobacco smoke. Tobac Contr. 2004;13:17–22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Leaderer BP, Hammond SK. Evaluation of vapor-phase nicotine and respirable suspended particle mass as markers for environmental tobacco smoke. Environ Sci Tech. 1991;25(4):770–777. [Google Scholar]
- 5. Wilson KM, Klein JD, Blumkin AK, Gottlieb M, Winickoff JP. Tobacco-smoke exposure in children who live in multiunit housing. Pediatrics. 2011;127(1):85–92. [DOI] [PubMed] [Google Scholar]
- 6. Hewett MJ, Sandell SD, Anderson J, Niebuhr M. Secondhand smoke in apartment buildings: renter and owner or manager perspectives. Nicotine Tob Res. 2007;9(Suppl. 1:S39–S47 [DOI] [PubMed] [Google Scholar]
- American Lung Association, Environmental Protection Agency, Consumer Product Safety Commission, American Medical Association. Indoor air pollution: an introduction for health professionals. 1996. http://www.epa.gov/iaq/pdfs/indoor_air_pollution.pdf Accessed August 11, 2014.
- 8. Digenis-Bury EC, Brooks DR, Chen L, Ostrem M, Horsburgh CR. Use of a population-based survey to describe the health of Boston public housing residents. Am J Publ Health. 2008;98(1):85–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Klepeis NE, Nelson WC, Ott, et al. The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants. J Expo Anal Environ Epidemiol. 2001;11(3):231–252. [DOI] [PubMed] [Google Scholar]
- 10. Hyland A, Higbee C, Travers MJ, et al. Smoke-free homes and smoking cessation and relapse in a longitudinal population of adults. Nicotine Tob Res. 2009;11(6):614–618. doi:10.1093/ntr/ntp022 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Jaakkola MS, Jaakkola JJK. Assessment of exposure to environmental tobacco smoke. Eur Respir J. 1997;10(10):2384–2397. [DOI] [PubMed] [Google Scholar]
- 12. EPA. 2013. PM2.5 NAAQS implementation. U.S. Environmental Protection Agency http://www.epa.gov/ttn/naaqs/pm/pm25_index.html Accessed June 09, 2013.
- 13. Marshall J. PM 2.5. Proc Natl Acad Sci USA. 2013;110(22):–8756. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. King BA, Travers MJ, Cummings KM, Mahoney MC, Hyland AJ. Secondhand smoke transfer in multiunit housing. Nicotine Tob Res. 2010;12(11):1133–1141. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Van Deusen A, Hyland A, Travers MJ, et al. Secondhand smoke and particulate matter exposure in the home. Nicotine Tob Res. 2009;11(6) :635–641. [DOI] [PubMed] [Google Scholar]
- 16. Repace JL, Lowrey AH. An enforceable indoor air quality standard for environmental tobacco smoke in the workplace. Risk Anal. 1993;13(4):463–475. http://www.ncbi.nlm.nih.gov/pubmed/8234955 [DOI] [PubMed] [Google Scholar]
- 17. Arku RE, Adamkiewicz G, Vallarino J, Spengler JD, Levy DE. Seasonal variability in environmental tobacco smoke exposure in public housing developments. Indoor Air. 2014. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. Eftim SE, Samet JM, Janes H, McDermott A, Dominici F. Fine particulate matter and mortality: A comparison of the six cities and American Cancer Society cohorts with a medicare cohort. Epidemiology (Cambridge, Mass.). 2008;19(2):209–216. [DOI] [PubMed] [Google Scholar]
- 19. Lepeule J, Laden F, Dockery D, Schwartz J. Chronic exposure to fine particles and mortality: an extended follow-up of the Harvard Six Cities study from 1974 to 2009. Environ Health Perspect. 2012;120(7):965–970. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20. Pope CA., III Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution. JAMA. 2002;287(9):1132–1141. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Puett RC, Hart JE, Yanosky JD, et al. Chronic fine and coarse particulate exposure, mortality, and coronary heart disease in the Nurses’ Health Study. Environ Health Perspect. 2009;117(11):1697–1701. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. EPA. 2013. National ambient air quality standards for particulate matter. Pub. L. No. 40 CFR Parts 50, 51, 52, 53, and 58. Environmental Protection Agency http://www.gpo.gov/fdsys/pkg/FR-2013-01-15/pdf/2012-30946.pdf
- 23. HUD. 2012. Notice: PIH-2012-25 (pp. 1–3). http://portal.hud.gov/hudportal/documents/huddoc?id=12-25pihn.pdf [Google Scholar]