Abstract
Occasional sphygmomanometric readings are not an effective way of evaluating the effect of treatment in patients with hypoadrenergic orthostatic hypotension. A novel non-invasive portable device (Portapres) was used to monitor 24 hour continuous finger blood pressure before and during chronic volume expansion in a 66 year old woman with severe orthostatic hypotension. In both conditions pressures while she was standing were lowest in the morning. Her tolerance to standing and walking increased during the day and, as a consequence of a higher upright mean blood pressure, was improved after treatment. Mean blood pressure during sleep was increased after treatment. Continuous 24 hour non-invasive finger blood pressure monitoring is a promising technique for the evaluation of the effect of treatment in patients with autonomic failure. It provides information about situations in daily life that cannot be obtained by laboratory tests or conventional sphygmomanometric measurements.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bevan A. T., Honour A. J., Stott F. H. Direct arterial pressure recording in unrestricted man. Clin Sci. 1969 Apr;36(2):329–344. [PubMed] [Google Scholar]
- Hoeldtke R. D., Streeten D. H. Treatment of orthostatic hypotension with erythropoietin. N Engl J Med. 1993 Aug 26;329(9):611–615. doi: 10.1056/NEJM199308263290904. [DOI] [PubMed] [Google Scholar]
- Imholz B. P., Langewouters G. J., van Montfrans G. A., Parati G., van Goudoever J., Wesseling K. H., Wieling W., Mancia G. Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording. Hypertension. 1993 Jan;21(1):65–73. doi: 10.1161/01.hyp.21.1.65. [DOI] [PubMed] [Google Scholar]
- Mann S., Altman D. G., Raftery E. B., Bannister R. Circadian variation of blood pressure in autonomic failure. Circulation. 1983 Sep;68(3):477–483. doi: 10.1161/01.cir.68.3.477. [DOI] [PubMed] [Google Scholar]
- Ten Harkel A. D., Van Lieshout J. J., Wieling W. Treatment of orthostatic hypotension with sleeping in the head-up tilt position, alone and in combination with fludrocortisone. J Intern Med. 1992 Aug;232(2):139–145. doi: 10.1111/j.1365-2796.1992.tb00563.x. [DOI] [PubMed] [Google Scholar]
- Wieling W., ten Harkel A. D., van Lieshout J. J. Spectrum of orthostatic disorders: classification based on an analysis of the short-term circulatory response upon standing. Clin Sci (Lond) 1991 Aug;81(2):241–248. doi: 10.1042/cs0810241. [DOI] [PubMed] [Google Scholar]
- Zachariah P. K., Krier J., Schwartz G. L. Orthostatic hypotension and ambulatory blood pressure monitoring. J Hypertens Suppl. 1991 Dec;9(8):S78–S80. [PubMed] [Google Scholar]
- di Rienzo M., Grassi G., Pedotti A., Mancia G. Continuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure. Hypertension. 1983 Mar-Apr;5(2):264–269. doi: 10.1161/01.hyp.5.2.264. [DOI] [PubMed] [Google Scholar]
- van Lieshout J. J., ten Harkel A. D., Wieling W. Physical manoeuvres for combating orthostatic dizziness in autonomic failure. Lancet. 1992 Apr 11;339(8798):897–898. doi: 10.1016/0140-6736(92)90932-s. [DOI] [PubMed] [Google Scholar]