Abstract
Antibody-drug conjugates (ADCs) are a class of immunotherapeutic agents that enable the delivery of cytotoxic drugs to target malignant cells. Because various cancers and tumour vascular endothelia strongly express anti-human tissue factor (TF), we prepared ADCs consisting of a TF-specific monoclonal antibody (mAb) linked to the anticancer agent (ACA) monomethyl auristatin E (MMAE) via a valine-citrulline (Val-Cit) linker (human TF ADC). Identifying the most efficient drug design in advance is difficult because ADCs have complicated structures. The best method of assessing ADCs is to examine their selectivity and efficiency in releasing and distributing the ACA within tumour tissue. Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) can be used to directly detect the distributions of native molecules within tumour tissues. Here, MALDI-IMS enabled the identification of the intratumour distribution of MMAE released from the ADC. In conclusion, MALDI-IMS is a useful tool to assess ADCs and facilitate the optimization of ADC design.
Antibody-drug conjugates (ADCs) are a class of immunotherapeutic agents that enable the delivery of cytotoxic drugs to target malignant cells. ADCs passively accumulate in solid tumour tissue through the enhanced permeability and retention effect1 and actively accumulate in target malignant cells because of the specific antibody-antigen binding2. The selection of a suitable monoclonal antibody (mAb), an anticancer agent (ACA), and a linker have supported the clinical success of ADCs3. The ADC strategy should be confined to highly toxic ACAs and not applied to ordinary ACAs, such as taxane, adriamycin, and others, because fewer than four ACA molecules should be conjugated to the mAb to prevent a decrease in the affinity of the mAb when too many ACA molecules are attached4. Monomethyl auristatin E (MMAE) is one of the most useful and potent ACAs for the clinical development of novel ADCs5,6. MMAE inhibits cell division by blocking the polymerization of tubulin.
In our laboratory, we have created an anti-human tissue factor (TF) mAb attached to valine-citrulline (Val-Cit)-MMAE (human TF ADC) and have reported its antitumour effect against xenografts of a human pancreatic cancer cell line, BxPC-37. The Val-Cit-MMAE has been designed for maximum serum stability and efficient release into the tumour environment8. Once human TF ADC binds to the target malignant cells, it is internalized by endocytosis, and MMAE is theoretically released into the tumour environment through the action of the lysosomal enzymes on the linker. TF is a transmembrane glycoprotein involved in the initiation of the extrinsic pathway of blood coagulation9, is expressed in various types of cancer, and plays a role in cancer progression, angiogenesis, tumour growth, and metastasis10. Because pancreatic cancer tissue expresses high levels of TF, it is a useful target antigen for this condition11,12,13.
To optimize the efficacy of an ADC against TF-positive solid tumours, a preclinical pharmacological evaluation of the ADC should be performed to determine whether the human TF ADC has been optimally designed. Regarding antitumour effects, ACAs must penetrate the tumour tissue efficiently and be retained there at a high and biologically active concentration14,15. For such analyses, high-performance liquid chromatography (HPLC) or liquid chromatography mass spectrometry (LC-MS) is generally used. However, these techniques do not provide information about the drug distribution in a specific target area, although they allow optimization of the drug design to a certain extent, enabling more efficiently targeted delivery. Autoradiography can be used to examine the tissue distribution of radiolabelled small molecules16. However, this method cannot distinguish between a radiolabelled drug conjugated to an ADC and free radiolabelled drug released from the ADCs17.
There are two types of matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS): One type can detect larger molecules18, although it is currently difficult to directly ionize high-molecular weight proteins, such as mAbs. The other type, which was used in our study, is specifically designed for low-molecular weight substances, such as ACAs. Although it is difficult to determine the distribution of ADCs from a technical standpoint, MALDI-IMS is a useful analytical tool for verifying whether the ADCs release their cytotoxic agent within the tumour tissues as designed. Mass spectrometry (MS) and tandem MS (MS/MS) do not require labelling reagents, and MALDI-IMS can provide accurate maps of the target molecules in tissue specimens directly19.
In this study, we investigated the efficiency of MMAE release from human TF ADCs within tumour tissue and the spatial distribution of the released MMAE therein by using MALDI-IMS. The imaging data were acquired using a mass microscope capable of analysing low-molecular weight compounds. The MMAE was imaged with accurate mass at a pixel size between 10 and 20 μm.
Results
Visualization of MMAE based on the MMAE-specific MS/MS fragment m/z 496.3 using MALDI-IMS
For the application of MALDI to MMAE analysis, α-cyano-4-hydroxycinnamic acid (CHCA) in 75% acetonitrile, 0.02% trifluoroacetic acid, 2.0-mM sodium acetate and a 1/1000 dilution of aniline were used for crystallization. The chemical formula of MMAE is C39H67N5O7, and its monoisotopic mass is 717.504. Three positive-ion peaks derived from MMAE were observed by MS analysis: single-charge hydrogen, and the sodium and potassium adducts, denoted as [M + H]+, [M + Na]+, and [M + K]+, respectively (Fig. 1a). The main fragment at m/z 496.3 was observed when m/z 740.4 was used as a precursor ion in the MS/MS analysis (Fig. 1b). The validation of the MMAE distribution in each sample was performed in MS/MS mode, and m/z 496.3 was selected as an assigned MMAE-specific fragment peak. The results of the MS and MS/MS analyses of MMAE were summarized in Table 1.
Table 1. MS and MS/MS of MMAE.
MS | MMAE | |
---|---|---|
m/z | ||
(a) | ||
[M + H]+ | 718.4 | |
[M + Na]+ | 740.4 | |
[M + K]+ | 756.4 | |
(b) | ||
Precursor ion | [M + H]+ | 321.2 |
506.3 | ||
687.4 | ||
[M + Na]+ | 496.3 | |
682.3 | ||
722.4 | ||
[M + K]+ | 512.2 | |
544.3 | ||
698.3 |
(a) The three positive-ion peaks derived from MMAE were observed by MS analysis: single-charge hydrogen and sodium and potassium adducts, denoted as [M + H]+, [M + Na]+, and [M + K]+, respectively. (b) MS/MS fragments of MMAE determined from each of the three positive-ion peaks of MMAE.
Semi-quantitative analysis of MMAE using MALDI-IMS
MMAE was semi-quantitatively detected at different concentrations with IMS (Fig. 2a). Then, 0.2-mg/kg MMAE alone was injected intravenously into the tail vein of the BxPC-3 xenograft model. The 5.0-mg/mL CHCA solution was applied by pinpoint spray gun to the tissue sections. The signals originating from the MMAE were detected in the tumour tissues at 3, 24, and 72 h after the administration of MMAE alone. The MMAE signal decreased in a time-dependent manner (Fig. 2b). Tissue sections serial to those used for MALDI-IMS were also quantified using LC-MS/MS (Fig. 2c), and the results were consistent with the IMS data from MMAE.
Selective detection of MMAE alone over MMAE conjugated to mAb using MALDI-IMS
We prepared the human TF ADC and its control ADC, which did not bind the TF antigen, and the drug-to-antibody ratio (DAR) of the ADCs was 2–4 (Fig. 3a). The ADCs were crystallized with the CHCA solution. MALDI-IMS was performed on the ADC sample and on MMAE alone in MS mode (Fig. 3b,c). The signal intensity of MMAE increased in a concentration-dependent manner, and the signal intensity obtained from 1.0 μL of 1.0-μM MMAE alone was significantly higher than that from 1.0 μL of 1.0-μM human TF ADC and the control ADC (Tukey-Kramer, P < 0.01). The MALDI analysis was capable of distinguishing between MMAE alone and ADCs conjugated with MMAE.
Visualization of MMAE released from ADCs in tumour tissues through MALDI-IMS
The signals originating from the MMAE released from ADCs were detected in the tumour tissues at 3, 24, and 72 h after the administration of the ADCs. The MMAE signal detected following the accumulation of the human TF ADC in the tumour tissue was greatest 24 h after administration, compared with the control ADC at the same time (Tukey-Kramer, P < 0.01, Fig. 4a,b). Tissue sections serial to those for MALDI-IMS were also quantified with LC-MS/MS (Fig. 4c), and the results were consistent with the IMS data from MMAE.
High-resolution MALDI-IMS of MMAE in tumour tissues
To determine the characteristics of the MMAE distribution 24 h after the injection of the ADCs, MMAE was imaged at a pixel size of 10 μm. After 24 h, the released MMAE was present at a significantly higher concentration in the cancerous part after the injection of the human TF ADC, compared with the control ADC (Fig. 5a,b). The proportion of areas in the cancerous parts that contained MMAE after the injection of human TF ADC after 24 h was higher than that in the stroma parts (Student’s t-test, P = 0.003). Haematoxylin and eosin (H&E) staining revealed the histology of the BxPC-3 tumour tissue, which was composed of cancerous and stroma parts. Anti-mouse CD31 immunohistochemistry revealed the distribution of vascular endothelial cells in the BxPC-3 tumour tissue sections. CD31 was expressed in the stroma parts. Anti-rat IgG immunohistochemistry revealed that the anti-human TF mAb or its corresponding ADC was observed mainly in the cancerous parts. In contrast, the control mAb or its corresponding ADC was observed mainly in the stroma parts (Fig. 5c).
Discussion
Nearly 50 individual ADCs are currently being examined in clinical trials, and 62% of the ACAs used for the ADCs are auristatin analogues, such as MMAE and monomethyl auristatin F (MMAF)20. Optimized linker design is required to release ACAs selectively at tumour sites. To improve the therapeutic window of an ADC, efforts have been made to improve linker technology over the past decade. We conducted quantitative and a semi-quantitative analyses of MMAE in BxPC-3 subcutaneous tumours by using LC-MS/MS and MALDI-IMS, respectively.
Unlike a pharmacological study using conventional tools, such as HPLC and LC/MS, MALDI-IMS can provide additional information about the distribution of MMAE in tumour tissues. Despite recent progress in MALDI techniques, it remains difficult to ionize macromolecular proteins21,22. The MALDI-IMS technique used in our study is specifically designed for low-molecular weight substances. Although we attempted to directly ionize the mAb and ADC in the tumour tissue by selective fragmentation with different proteases, it was difficult to determine MMAE alone, mAb, and ADC. However, our MALDI-IMS technique is valuable for optimizing the ADC. The present study clearly showed that MALDI-IMS can be used to visualize only free MMAE without interference from MMAE conjugated to mAb. Thus, MALDI-IMS is a novel evaluation method for the semi-quantitative determination of the intratumour distributions of MMAE released by ADCs.
The selection of a proper rational matrix is important to ionize MMAE using MALDI. We tested several matrixes, including 2, 5-dihydroxybenzoic acid, 9-aminoacridine, sinapine acid and CHCA, and found that CHCA was the optimal matrix for the IMS analysis of MMAE in tumour tissue. A CHCA solution containing 2.0-mM sodium acetate and aniline promoted the ionization of MMAE to create sodium adducts. According to the MS/MS peak in the present study–m/z 496.3, which was selected as an MMAE-specific fragment peak–MMAE can be observed with high reliability and accuracy in tumour tissues. MALDI-IMS was able to detect 1.0 fmol of MMAE, although the signal intensity was low. However, some aspects of the ionization uncertainty might not be captured by MALDI classification and are otherwise difficult to quantify. Further studies examining the adequacy of quantification using MALDI-IMS are needed.
The laser beam diameter used corresponded to a spatial resolution of 10 μm. This resolution allowed us to discriminate between the cancerous and cancer stroma parts of tumour tissue. However, cellular-level investigations remain impossible because the diameters of cells are typically 5 to 25 μm. Thus, improved resolution is needed to investigate whether MMAE is located within the tumour cells. However, MALDI-IMS represents a step forward, revealing the accumulation of MMAE released from human TF ADCs in the cancerous part. This distinctive accumulation of MMAE is reasonable given the high antitumour effects of human TF ADCs against the TF-positive BxPC-3 tumour.
In conclusion, MALDI-IMS is expected to be a powerful tool for design optimization of ADCs in the preclinical stage.
Materials and Methods
ADCs
Previously, we have developed several clones of anti-human TF mAb. Clone 1849 rat IgG2b has a high affinity for the TF antigen, whereas clone 372 rat IgG2b does not bind the TF antigen at all. Thus, we used clone 372 as an isotype-control mAb. The Val-Cit-MMAE consisted of a maleimide serving as the connection to the mAbs, PEG12 (Quanta BioDesign, CA, USA) to increase the polarity, a Val-Cit dipeptide to trigger cleavage by intracellular proteases, and a para-amino benzyl carbamate (PABC) as a self-immolative spacer for efficient MMAE release. MMAE (Medchem Express, NJ, USA) was dissolved in dimethyl sulfoxide (10 mM) and stored at −80 °C. The ADCs were produced by reducing the inter-chain disulfide bonds. The DAR of the ADCs was 2–4, as determined by the colourimetric measurement of thiol groups in biological samples using Ellman’s reagent, DTNB.
Pancreatic cancer cell line BxPC-3 xenograft model
The human pancreatic cancer cell line BxPC-3 was obtained from the American Type Culture Collection (Manassas, VA). BxPC-3 cells were maintained at 37 °C in a humidified atmosphere with 5% CO2 and grown in RPMI-1640 medium (Wako, Osaka, Japan) containing 10% foetal bovine serum (FBS; Gibco, Grand Island, NY), 100-U/mL penicillin, 100-μg/mL streptomycin, and 0.25-μg/mL amphotericin B (Wako).
Six-week-old female BALB/c nude mice (CLEA Japan, Tokyo, Japan) were used. The anesthetized mice were subcutaneously inoculated with 1.0 × 106 BxPC-3 cells suspended in 100 μL of phosphate-buffered saline (PBS) on the right back. The mice were injected with the agents (MMAE alone, human TF ADC, or control ADC) when the tumour volume (TV) reached 350 ± 150 mm3 (5 mice per group, N = 5). The TV was calculated using the following formula and the length (L) and width (W) of the subcutaneous tumour: TV = (L × V2)/2. The mice were maintained in cages under specific pathogen-free conditions, provided with standard food, and given free access to sterilized water.
To evaluate the distribution of MMAE in the tumour tissue, 0.2-mg/kg MMAE alone and 10-mg/kg ADCs were injected intravenously into the tail vein. The tumour tissue samples were surgically removed from a xenograft model at 3, 24, or 72 h after the administration of the agents. The samples were wrapped in gauze, frozen in dry ice powder, and stored in a −80 °C freezer until further analysis. For analysis, the samples were sectioned at a thickness of 10 μm and transferred to an indium tin oxide (ITO)-coated glass slide (Sigma, St. Louis, MO), and the tissue sections were dried before matrix coating. Continuous sections were stained with H&E (Muto Pure Chemicals, Tokyo, Japan) and immunohistochemistry.
The study was approved by the Committee for Animal Experimentation of the National Cancer Center, Tokyo, Japan. All animal procedures were performed in accordance with the Guidelines for the Care and Use of Experimental Animals established by the Committee. These guidelines meet the ethical standards required by law and also comply with the guidelines for the use of experimental animals in Japan.
MALDI-IMS using mass microscopy
The IMS analysis was performed using an atmospheric pressure MALDI-ion trap (IT)-time-of-flight (TOF) mass spectrometer (prototype Mass Microscope; Shimadzu, Kyoto, Japan). The MALDI-IMS used in our study is specifically designed for detecting low-molecular weight analytes (with a mass detection range from m/z 50 to m/z 5,000).
For the application of MALDI to MMAE imaging, CHCA (Nacalai, Kyoto, Japan) in 75% acetonitrile, 0.02% trifluoroacetic acid, 2.0-mM sodium acetate and a 1/1000 dilution of aniline were used. To determine the definition of the MS and the MS/MS analysis of MMAE, 1.0 μL of a 10-mg/mL CHCA solution was used for the ionization of an MMAE standard (1.0 μL) onto an ITO slide. The mass spectrum was obtained by summing the signal intensities in the measurement areas. The CHCA on the tissue section was applied with a pinpoint spray gun (GSI Creos, Tokyo, Japan). Then, a 5.0-mg/mL CHCA solution was used for the ionization of the tissue samples. The total amount of CHCA per ITO slide was 30–35 mg.
MS and MS/MS analyses were performed in positive-ion mode within a mass range of m/z 150–770 for MMAE, with spatial resolutions of 10 and 20 μm. The laser was modulated to 80–160 shots/spectrum with a frequency of 400–800 Hz, and the laser power was set to 50–65 using the Mass Microscope operation software. The MS/MS analysis was performed with the collision-induced dissociation (CID) function of the quadruple ion trap cell on the Mass Microscope. The m/z 496.3 fragment ion was generated when [M + Na]+ was used as a precursor ion in the MS/MS analysis. The MMAE distribution mapping was performed using BioMap (Novartis, Basel, Switzerland) with the m/z 496.3 fragment ion signal obtained by MS/MS analysis. The non-treated BxPC-3 tumour tissues were used as a negative control to determine the baseline of the MS/MS analysis. The IMS data are shown as pseudo-colour images (Red-Purple). The baseline intensity had a value of 3; therefore, the minimum intensity was set to 4. To achieve a visible IMS signal, the maximum intensity was set to 10. The ratio [%] of the areas occupied by MMAE [μm2] to the whole measurement areas [μm2] in the tumour tissues was measured with ImageJ software23.
LC-MS/MS
The samples were analysed using a liquid chromatograph tandem mass spectrometer API3200 LC-MS/MS system (AB SCIEX, Framingham, MA). The analytical column, a reversed-phase LC column (4.0 μm polar, 80 Å; 50 × 3.0 mm, Synergi; Shimazu), was heated to 40 °C. The injection volume was 10 μm, and the flow rate was 0.4 mL/min. The autosampler was equipped with a cooling stack set at 4 °C. Acetonitrile and a 0.1% (w/v) formic acid solution were used as the mobile phases. For the gradient elution, the mobile phase composition was as follows: 5% acetonitrile for 1.0 min, increased to 40% for 2.0 min, increased to 100% for 2.0 min, maintained at 100% for 2.0 min, and then decreased back to 5.0% for 2.0 min. The mobile phase was introduced into the spectrometer via electrospray ionization in positive-ion mode under multiple reaction monitoring (MRM) conditions. The MRM transitions were used for MMAE (m/z 718.4/152.2) and MMAF as an internal standard (m/z 732.4/170.3). The standard curve had a linear range from 0.10 nM to 100 nM. Samples from the non-treated BxPC-3 tumour tissues were used as a negative control.
Immunohistochemistry
The 10-μm frozen sections were fixed with 4% paraformaldehyde (Wako) for 10 min. To block endogenous peroxidase, 3% hydrogen peroxide for 20 min was used. After being blocked with 3% skim milk in PBS for 30 min, the sections were incubated with an anti-rat IgG goat antibody (Histostar; MBL, Nagoya, Japan) for mAb/ADC according to the manufacturer’s instructions. The continuous sections were incubated with an anti-mouse CD31 goat antibody for vascular endothelial cells (10 μg/mL; R&D Systems, Minneapolis, MN) for 1 h at room temperature. After being washed with PBS, the sections were incubated with a horseradish peroxidase (HRP)-conjugated anti-goat IgG antibody (Jackson IR, West Grove, PA) according to the manufacturer’s instructions. Counterstaining was performed using haematoxylin. Negative controls included the replacement of the primary antibody by PBS and isotype antibodies.
Statistics
Measured differences were considered significant at P < 0.05. For the quantification of MMAE using LC-MS/MS, statistical significance was determined using the Tukey-Kramer multiple comparison test. To distinguish between MMAE alone and MMAE conjugated to a mAb, statistical significance was determined using the Tukey-Kramer multiple comparison test. For the high-resolution MALDI-IMS of MMAE in tumour tissues, statistical significance was determined using the two-sided Student’s t-test. The bar graph data were expressed as the mean ± standard deviation (SD). The error bars indicated the SD. The statistical analyses were performed using Statcal QC (The publisher OMS, Saitama, Japan).
Additional Information
How to cite this article: Fujiwara, Y. et al. Imaging mass spectrometry for the precise design of antibody-drug conjugates. Sci. Rep. 6, 24954; doi: 10.1038/srep24954 (2016).
Acknowledgments
We thank S. Saijou, F. Furuya, and S. Hanaoka for assistance in producing the anti-human TF mAb. We also thank Mrs. M. Nakayama for her secretarial support. This work was supported by the National Cancer Center Research and Development Fund (26-A-14 for Y.M., 26-A-12 for M.Y.); the Third Term Comprehensive Control Research for Cancer from the Ministry of Health, Labour, and Welfare of Japan (Y.M.); a Grant-in-Aid for Scientific Research on Priority Areas from the Ministry of Education, Culture, Sports, Science, (Y.M.); and Practical Research for Innovative Cancer Control (15ck0106114h0002) from the Japan Agency for Medical Research and Development, AMED (M.Y.).
Footnotes
Author Contributions Y.M. provided the original concept for the research. Y.F. and M.Y. designed the study. Y.F., M.F. and S.M. performed the experiments. Y.F., M.F., S.M., Y.K., M.Y. and Y.M. discussed the results and wrote the paper.
References
- Matsumura Y. & Maeda H. A new concept for macromolecular therapeutics in cancer chemotherapy: mechanism of tumoritropic accumulation of proteins and the antitumor agent smancs. Cancer Res 46, 6387–92 (1986). [PubMed] [Google Scholar]
- Hellstrom K. E., Hellstrom I. & Brown J. P. Human tumor-associated antigens identified by monoclonal antibodies. Springer Semin Immunopathol 5, 127–46 (1982). [DOI] [PubMed] [Google Scholar]
- Sievers E. L. & Senter P. D. Antibody-drug conjugates in cancer therapy. Annu Rev Med 64, 15–29 (2013). [DOI] [PubMed] [Google Scholar]
- Junutula J. R. et al. Site-specific conjugation of a cytotoxic drug to an antibody improves the therapeutic index. Nat Biotechnol 26, 925–32 (2008). [DOI] [PubMed] [Google Scholar]
- Thudium K. et al. American Association of Pharmaceutical Scientists National Biotechnology Conference Short Course: Translational Challenges in Developing Antibody-Drug Conjugates: May 24, 2012, San Diego, CA. MAbs 5, 5–12 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zolot R. S., Basu S. & Million R. P. Antibody-drug conjugates. Nat Rev Drug Discov 12, 259–60 (2013). [DOI] [PubMed] [Google Scholar]
- Koga Y. et al. Antitumor effect of anti-tissue factor antibody-MMAE conjugate in human pancreatic tumor xenografts. Int J Cancer 137, 1257–1466 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sanderson R. J. et al. In vivo drug-linker stability of an anti-CD30 dipeptide-linked auristatin immunoconjugate. Clin Cancer Res 11, 843–52 (2005). [PubMed] [Google Scholar]
- Chu A. J. Tissue factor, blood coagulation, and beyond: an overview. Int J Inflam 2011, 367284 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
- van den Berg Y. W., Osanto S., Reitsma P. H. & Versteeg H. H. The relationship between tissue factor and cancer progression: insights from bench and bedside. Blood 119, 924–32 (2012). [DOI] [PubMed] [Google Scholar]
- Flossel C., Luther T., Muller M., Albrecht S. & Kasper M. Immunohistochemical detection of tissue factor (TF) on paraffin sections of routinely fixed human tissue. Histochemistry 101, 449–53 (1994). [DOI] [PubMed] [Google Scholar]
- Nitori N. et al. Prognostic significance of tissue factor in pancreatic ductal adenocarcinoma. Clin Cancer Res 11, 2531–9 (2005). [DOI] [PubMed] [Google Scholar]
- Khorana A. A. et al. Tissue factor expression, angiogenesis, and thrombosis in pancreatic cancer. Clin Cancer Res 13, 2870–5 (2007). [DOI] [PubMed] [Google Scholar]
- Minchinton A. I. & Tannock I. F. Drug penetration in solid tumours. Nat Rev Cancer 6, 583–92 (2006). [DOI] [PubMed] [Google Scholar]
- Kim M., Gillies R. J. & Rejniak K. A. Current advances in mathematical modeling of anti-cancer drug penetration into tumor tissues. Front Oncol 3, 278 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Solon E. G. Use of radioactive compounds and autoradiography to determine drug tissue distribution. Chem Res Toxicol 25, 543–55 (2012). [DOI] [PubMed] [Google Scholar]
- Xie H., Audette C., Hoffee M., Lambert J. M. & Blattler W. A. Pharmacokinetics and biodistribution of the antitumor immunoconjugate, cantuzumab mertansine (huC242-DM1), and its two components in mice. J Pharmacol Exp Ther 308, 1073–82 (2004). [DOI] [PubMed] [Google Scholar]
- Mainini V. et al. Detection of high molecular weight proteins by MALDI imaging mass spectrometry. Mol Biosyst 9, 1101–7 (2013). [DOI] [PubMed] [Google Scholar]
- Yasunaga M. et al. The significance of microscopic mass spectrometry with high resolution in the visualisation of drug distribution. Sci Rep 3, 3050 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stacy Shifflett Shord, S. J. S., Hong Zhao, Brian Booth, Nam Atiqur Rahman. Regulatory considerations for clinical pharmacology during development of antibody-drug conjugates. J Clin Oncol 33, 2015 (suppl; abstr 2569) (2015).
- Furuichi Y. et al. Imaging mass spectrometry reveals fiber-specific distribution of acetylcarnitine and contraction-induced carnitine dynamics in rat skeletal muscles. Biochim Biophys Acta 1837, 1699–1706 (2014). [DOI] [PubMed] [Google Scholar]
- Aichler M. & Walch A. MALDI Imaging mass spectrometry: current frontiers and perspectives in pathology research and practice. Lab Invest 95, 422–31 (2015). [DOI] [PubMed] [Google Scholar]
- Schneider C. A., Rasband W. S. & Eliceiri K. W. NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9, 671–5 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]