Abstract
OBJECTIVE--To determine the prevalence of pseudoaneurysm formation after aortic (left ventricular outflow tract) homograft implantation and to evaluate predisposing factors. METHODS--Echocardiographic data were analysed in 30 patients for evidence of pseudoaneurysm formation after homograft implantation. Pseudoaneurysm was characterised as a perfused echo-free space between the homograft and the native aortic wall communicating with the left ventricular outflow tract. Clinical data were analysed for potential predisposing factors for pseudoaneurysm formation. RESULTS--Pseudoaneurysms were found in 22 of 30 patients. Mean age, length of follow up after surgery, aortic systolic pressure gradient (15 (SD 12) v 10 (4) mm Hg), aortic root diameter, and size of the homografts were comparable in patients with and without pseudoaneurysm. preoperative infection, operating techniques, and whether first or reoperation did not affect pseudoaneurysm formation. However, pseudoaneurysms were often localised at the site of an abscess or a paravalvular leak after eradicated prosthetic valve endocarditis. CONCLUSIONS--(1) Doppler echocardiography demonstrates that pseudoaneurysm formation is common after aortic homograft implantation. (2) A prospective study is needed to clarify the prognostic importance of pseudoaneurysms. (3) The high incidence of pseudoaneurysm formation may lead to an improvement of surgical technique (application of fibrin glue).
Full text
PDF




Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- BARRATT-BOYES B. G. HOMOGRAFT AORTIC VALVE REPLACEMENT IN AORTIC INCOMPETENCE AND STENOSIS. Thorax. 1964 Mar;19:131–150. doi: 10.1136/thx.19.2.131. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Barbetseas J., Crawford E. S., Safi H. J., Coselli J. S., Quinones M. A., Zoghbi W. A. Doppler echocardiographic evaluation of pseudoaneurysms complicating composite grafts of the ascending aorta. Circulation. 1992 Jan;85(1):212–222. doi: 10.1161/01.cir.85.1.212. [DOI] [PubMed] [Google Scholar]
- Barratt-Boyes B. G., Roche A. H., Subramanyan R., Pemberton J. R., Whitlock R. M. Long-term follow-up of patients with the antibiotic-sterilized aortic homograft valve inserted freehand in the aortic position. Circulation. 1987 Apr;75(4):768–777. doi: 10.1161/01.cir.75.4.768. [DOI] [PubMed] [Google Scholar]
- Blackstone E. H., Kirklin J. W. Death and other time-related events after valve replacement. Circulation. 1985 Oct;72(4):753–767. doi: 10.1161/01.cir.72.4.753. [DOI] [PubMed] [Google Scholar]
- Haydock D., Barratt-Boyes B., Macedo T., Kirklin J. W., Blackstone E. Aortic valve replacement for active infectious endocarditis in 108 patients. A comparison of freehand allograft valves with mechanical prostheses and bioprostheses. J Thorac Cardiovasc Surg. 1992 Jan;103(1):130–139. [PubMed] [Google Scholar]
- Ivert T. S., Dismukes W. E., Cobbs C. G., Blackstone E. H., Kirklin J. W., Bergdahl L. A. Prosthetic valve endocarditis. Circulation. 1984 Feb;69(2):223–232. doi: 10.1161/01.cir.69.2.223. [DOI] [PubMed] [Google Scholar]
- Jaffe W. M., Coverdale H. A., Roche A. H., Brandt P. W., Ormiston J. A., Barratt-Boyes B. G. Doppler echocardiography in the assessment of the homograft aortic valve. Am J Cardiol. 1989 Jun 15;63(20):1466–1470. doi: 10.1016/0002-9149(89)90009-x. [DOI] [PubMed] [Google Scholar]
- Kirklin J. K., Pacifico A. D., Kirklin J. W. Surgical treatment of prosthetic valve endocarditis with homograft aortic valve replacement. J Card Surg. 1989 Dec;4(4):340–347. doi: 10.1111/j.1540-8191.1989.tb00301.x. [DOI] [PubMed] [Google Scholar]
- Kirklin J. K., Smith D., Novick W., Naftel D. C., Kirklin J. W., Pacifico A. D., Nanda N. C., Helmcke F. R., Bourge R. C. Long-term function of cryopreserved aortic homografts. A ten-year study. J Thorac Cardiovasc Surg. 1993 Jul;106(1):154–166. [PubMed] [Google Scholar]
- Kouchoukos N. T., Marshall W. G., Jr, Wedige-Stecher T. A. Eleven-year experience with composite graft replacement of the ascending aorta and aortic valve. J Thorac Cardiovasc Surg. 1986 Oct;92(4):691–705. [PubMed] [Google Scholar]
- Matsuki O., Robles A., Gibbs S., Bodnar E., Ross D. N. Long-term performance of 555 aortic homografts in the aortic position. Ann Thorac Surg. 1988 Aug;46(2):187–191. doi: 10.1016/s0003-4975(10)65895-x. [DOI] [PubMed] [Google Scholar]
- O'Brien M. F., McGiffin D. C., Stafford E. G., Gardner M. A., Pohlner P. F., McLachlan G. J., Gall K., Smith S., Murphy E. Allograft aortic valve replacement: long-term comparative clinical analysis of the viable cryopreserved and antibiotic 4 degrees C stored valves. J Card Surg. 1991 Dec;6(4 Suppl):534–543. doi: 10.1111/jocs.1991.6.4s.534. [DOI] [PubMed] [Google Scholar]
- Okita Y., Franciosi G., Matsuki O., Robles A., Ross D. N. Early and late results of aortic root replacement with antibiotic-sterilized aortic homograft. J Thorac Cardiovasc Surg. 1988 Apr;95(4):696–704. [PubMed] [Google Scholar]
- Pochis W. T., Cinquegrani M. P., McManus R. P., Almassi G. H. Periaortic hematoma formation leading to aortic valve failure. A complication of homograft placement for second valve surgery. Chest. 1992 Oct;102(4):1299–1301. doi: 10.1378/chest.102.4.1299. [DOI] [PubMed] [Google Scholar]
- ROSS D. N. Homograft replacement of the aortic valve. Lancet. 1962 Sep 8;2(7254):487–487. doi: 10.1016/s0140-6736(62)90345-8. [DOI] [PubMed] [Google Scholar]
- Ross D. Allograft root replacement for prosthetic endocarditis. J Card Surg. 1990 Mar;5(1):68–72. doi: 10.1111/j.1540-8191.1990.tb00739.x. [DOI] [PubMed] [Google Scholar]
- Sahn D. J., DeMaria A., Kisslo J., Weyman A. Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements. Circulation. 1978 Dec;58(6):1072–1083. doi: 10.1161/01.cir.58.6.1072. [DOI] [PubMed] [Google Scholar]
- Tuna I. C., Orszulak T. A., Schaff H. V., Danielson G. K. Results of homograft aortic valve replacement for active endocarditis. Ann Thorac Surg. 1990 Apr;49(4):619–624. doi: 10.1016/0003-4975(90)90311-s. [DOI] [PubMed] [Google Scholar]
- Virdi I. S., Monro J. L., Ross J. K. Eleven year experience of aortic valve replacement with antibiotic sterilized homograft valves in Southampton. Thorac Cardiovasc Surg. 1986 Oct;34(5):277–282. doi: 10.1055/s-2007-1022154. [DOI] [PubMed] [Google Scholar]
- von Segesser L. K., Oechslin E., Jenni R., Turina M. I. Use of glue to avoid formation of perfused recesses in aortic allograft implantation. Ann Thorac Surg. 1994 Feb;57(2):494–495. doi: 10.1016/0003-4975(94)91034-0. [DOI] [PubMed] [Google Scholar]



