Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1975 Jan;37(1):20–25. doi: 10.1136/hrt.37.1.20

Measurement of stroke volume from pulmonary artery pressure record in man.

A A Zacharoulis, T R Evans, G M Ziady, D J Coltart, J P Shillingford
PMCID: PMC484150  PMID: 803378

Abstract

Stroke volume was determined from the pulmonary artery pressure record by application of the pulse contour method. Pulmonary artery pressure records were obtained in 17 patients using a high fidelity catheter-tip pressure transducer and simultaneous measurements of cardiac output were obtained from indicator dilution curves. The formula used was SV = KP sa (i plus T s/Td) where Psa is the planimetered area beneath the systolic portion of the pulmonary artery pressure curve. Ts and Td are the durations of systole and diastole, and K is a constant. Stroke volume was altered by isometric handgrip exercise and/or pharmacological agents in 15 patients. Serial measurementswere made in 2 patients in acute pulmonary oedema after myocardial infarction. Comparison of a wide range of values of stroke volume by the pulse contour method with those obtained from dye dilution curves showed a good correlation (r plus 0.97, P smaller than 0.001) regression line y = 1.01 times - 0.47. Measurement of stroke volume from the pulmonary artery pressure contour is a technique of potential value in serial haemodynamic monitoring.

Full text

PDF
20

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Alderman E. L., Branzi A., Sanders W., Brown B. W., Harrison D. C. Evaluation of the pulse-contour method of determining stroke volume in man. Circulation. 1972 Sep;46(3):546–558. doi: 10.1161/01.cir.46.3.546. [DOI] [PubMed] [Google Scholar]
  2. Starmer C. F., McHale P. A., Cobb F. R., Greenfield J. C., Jr Evaluation of several methods for computing stroke volume from central aortic pressure. Circ Res. 1973 Aug;33(2):139–148. doi: 10.1161/01.res.33.2.139. [DOI] [PubMed] [Google Scholar]
  3. Stenson R., Crouse L., Harrison D. C. Computer measurement of cardiac output by dye dilution: comparison of computer, Fick, and Dow techniques. Cardiovasc Res. 1972 Jul;6(4):449–456. doi: 10.1093/cvr/6.4.449. [DOI] [PubMed] [Google Scholar]
  4. WARNER H. R., SWAN H. J. C., CONNOLLY D. C., TOMPKINS R. G., WOOD E. H. Quantitation of beat-to-beat changes in stroke volume from the aortic pulse contour in man. J Appl Physiol. 1953 Mar;5(9):495–507. doi: 10.1152/jappl.1953.5.9.495. [DOI] [PubMed] [Google Scholar]
  5. Warner H. R. The role of computers in medical research. JAMA. 1966 Jun 13;196(11):944–949. [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES