Abstract
OBJECTIVES: To assess the value of dobutamine stress echocardiography (DSE) in the prediction of the extent and location of coronary artery stenosis in symptomatic patients with old myocardial infarction and to study the impact of the severity of resting wall motion abnormalities (WMA) on the diagnostic accuracy of the test. PATIENTS: One hundred and thirty two symptomatic patients with old myocardial infarction. METHODS: DSE (up to 40 micrograms/kg/min, with atropine up to 1 mg) was performed in all patients. Ischaemia was defined as new or worsened WMA. For each coronary artery, regional wall motion in the corresponding territory was classified as normal, mildly, moderately, or severely impaired according to the wall motion score index. Significant coronary stenosis was defined as > or = 50% diameter stenosis. RESULTS: A positive DSE for ischaemia occurred in 87 of 111 patients with and three of 21 patients without coronary artery stenosis (sensitivity = 78%; CI 71 to 86, specificity = 86%; CI 79 to 92, accuracy = 80%; CI 73 to 87). The accuracy for the diagnosis of individual coronary stenosis was 69% in the presence of normal wall motion and 74%, 74%, and 61% respectively when there was mild, moderate, and severe WMA in the corresponding territories (P = NS). The sensitivity was higher in presence of mild or moderate WMA (73%) than with normal wall motion (53%) or severe WMA (56%, P < 0.05 in both). In territories subtended by a stenotic artery, the regional wall motion score index was not different with or without ischaemia. CONCLUSION: DSE had a good overall accuracy for the diagnosis of coronary artery stenosis in symptomatic patients with old myocardial infarction. The presence of resting WMA did not limit DSE as a method of eliciting myocardial ischaemia and diagnosing significant coronary artery stenosis in patients with old myocardial infarctions.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- André-Fouet X., Pillot M., Leizorovicz A., Finet G., Gayet C., Milon H. "Non-Q wave," alias "nontransmural," myocardial infarction: a specific entity. Am Heart J. 1989 Apr;117(4):892–902. doi: 10.1016/0002-8703(89)90629-7. [DOI] [PubMed] [Google Scholar]
- Armstrong W. F., O'Donnell J., Ryan T., Feigenbaum H. Effect of prior myocardial infarction and extent and location of coronary disease on accuracy of exercise echocardiography. J Am Coll Cardiol. 1987 Sep;10(3):531–538. doi: 10.1016/s0735-1097(87)80195-x. [DOI] [PubMed] [Google Scholar]
- Arnese M., Fioretti P. M., Cornel J. H., Postma-Tjoa J., Reijs A. E., Roelandt J. R. Akinesis becoming dyskinesis during high-dose dobutamine stress echocardiography: a marker of myocardial ischemia or a mechanical phenomenon? Am J Cardiol. 1994 May 1;73(12):896–899. doi: 10.1016/0002-9149(94)90819-2. [DOI] [PubMed] [Google Scholar]
- Baptista J., Arnese M., Roelandt J. R., Fioretti P., Keane D., Escaned J., Boersma E., di Mario C., Serruys P. W. Quantitative coronary angiography in the estimation of the functional significance of coronary stenosis: correlations with dobutamine-atropine stress test. J Am Coll Cardiol. 1994 May;23(6):1434–1439. doi: 10.1016/0735-1097(94)90388-3. [DOI] [PubMed] [Google Scholar]
- Brown K. A., Weiss R. M., Clements J. P., Wackers F. J. Usefulness of residual ischemic myocardium within prior infarct zone for identifying patients at high risk late after acute myocardial infarction. Am J Cardiol. 1987 Jul 1;60(1):15–19. doi: 10.1016/0002-9149(87)90975-1. [DOI] [PubMed] [Google Scholar]
- Coma-Canella I., Gómez Martínez M. V., Rodrigo F., Castro Beiras J. M. The dobutamine stress test with thallium-201 single-photon emission computed tomography and radionuclide angiography: postinfarction study. J Am Coll Cardiol. 1993 Aug;22(2):399–406. doi: 10.1016/0735-1097(93)90043-z. [DOI] [PubMed] [Google Scholar]
- Coronary heart disease death, nonfatal acute myocardial infarction and other clinical outcomes in the Multiple Risk Factor Intervention Trial. Multiple Risk Factor Intervention Trial Research Group. Am J Cardiol. 1986 Jul 1;58(1):1–13. doi: 10.1016/0002-9149(86)90232-8. [DOI] [PubMed] [Google Scholar]
- Dagianti A., Penco M., Agati L., Sciomer S., Dagianti A., Rosanio S., Fedele F. Stress echocardiography: comparison of exercise, dipyridamole and dobutamine in detecting and predicting the extent of coronary artery disease. J Am Coll Cardiol. 1995 Jul;26(1):18–25. doi: 10.1016/0735-1097(95)00121-f. [DOI] [PubMed] [Google Scholar]
- Feinstein A. R. T. Duckett Jones Memorial Lecture. The Jones criteria and the challenges of clinimetrics. Circulation. 1982 Jul;66(1):1–5. doi: 10.1161/01.cir.66.1.1. [DOI] [PubMed] [Google Scholar]
- Fioretti P. M., Poldermans D., Salustri A., Forster T., Bellotti P., Boersma E., McNeill A. J., el-Said E. S., Roelandt J. R. Atropine increases the accuracy of dobutamine stress echocardiography in patients taking beta-blockers. Eur Heart J. 1994 Mar;15(3):355–360. doi: 10.1093/oxfordjournals.eurheartj.a060503. [DOI] [PubMed] [Google Scholar]
- Marcovitz P. A., Armstrong W. F. Accuracy of dobutamine stress echocardiography in detecting coronary artery disease. Am J Cardiol. 1992 May 15;69(16):1269–1273. doi: 10.1016/0002-9149(92)91219-t. [DOI] [PubMed] [Google Scholar]
- Marwick T., D'Hondt A. M., Baudhuin T., Willemart B., Wijns W., Detry J. M., Melin J. Optimal use of dobutamine stress for the detection and evaluation of coronary artery disease: combination with echocardiography or scintigraphy, or both? J Am Coll Cardiol. 1993 Jul;22(1):159–167. doi: 10.1016/0735-1097(93)90830-t. [DOI] [PubMed] [Google Scholar]
- Proudfit W. J., Bruschke A. V., MacMillan J. P., Williams G. W., Sones F. M., Jr Fifteen year survival study of patients with obstructive coronary artery disease. Circulation. 1983 Nov;68(5):986–997. doi: 10.1161/01.cir.68.5.986. [DOI] [PubMed] [Google Scholar]
- Sawada S. G., Segar D. S., Ryan T., Brown S. E., Dohan A. M., Williams R., Fineberg N. S., Armstrong W. F., Feigenbaum H. Echocardiographic detection of coronary artery disease during dobutamine infusion. Circulation. 1991 May;83(5):1605–1614. doi: 10.1161/01.cir.83.5.1605. [DOI] [PubMed] [Google Scholar]
- Takeuchi M., Araki M., Nakashima Y., Kuroiwa A. The detection of residual ischemia and stenosis in patients with acute myocardial infarction with dobutamine stress echocardiography. J Am Soc Echocardiogr. 1994 May-Jun;7(3 Pt 1):242–252. doi: 10.1016/s0894-7317(14)80394-5. [DOI] [PubMed] [Google Scholar]