Abstract
OBJECTIVE: To study the potential interactions in patients with endocardial permanent pacemakers and non-thoracotomy implantable cardioverter defibrillator (ICD) systems. DESIGN: Case series and cohort study. SETTING: Tertiary referral centre. PATIENTS: Fifteen consecutive patients with both endocardial pacemakers (12 dual chamber and three single chamber) and non-thoracotomy ICD systems. MAIN OUTCOME MEASURES: Detection inhibition of induced ventricular fibrillation; double counting; and pacemaker function after shocks. In the evaluation of detection inhibition, 124 VF inductions were analysed for detection duration compared with induced VF episodes in controls with an ICD but without a pacemaker. RESULTS: Two patients (13%) showed detection inhibition of VF and required pacemaker system change at the time of the ICD implant. With the final lead position, despite frequent pacemaker undersensing of VF, ICD detection of VF was not inhibited during any induction, and neither initial detection nor redetection times for VF were different from controls. Double/triple counting of pacemaker artefact and evoked electrogram was noted in three patients (20%). In two, this was remedied during the implantation procedure, and in the other it was abolished when amiodarone treatment was discontinued. Pacemaker function was affected by ICD discharges in two patients, one who showed postshock atrial undersensing and loss of capture, and another whose pacemaker reverted to VVI mode. CONCLUSIONS: When careful testing is performed at implantation to detect and remedy device interactions, non-thoracotomy ICD treatment and endocardial pacemakers can be used safely in combination.
Full text
PDF





Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Barin E. S., Jones S. M., Ward D. E., Camm A. J., Nathan A. W. The right ventricular outflow tract as an alternative permanent pacing site: long-term follow-up. Pacing Clin Electrophysiol. 1991 Jan;14(1):3–6. doi: 10.1111/j.1540-8159.1991.tb04040.x. [DOI] [PubMed] [Google Scholar]
- Blanck Z., Niazi I., Axtell K., Sra J., Jazayeri M. R., Dhala A., Deshpande S., Akhtar M. Feasibility of concomitant implantation of permanent transvenous pacemaker and defibrillator systems. Am J Cardiol. 1994 Dec 15;74(12):1249–1253. doi: 10.1016/0002-9149(94)90557-6. [DOI] [PubMed] [Google Scholar]
- Brooks R., Garan H., McGovern B. A., Ruskin J. N. Implantation of transvenous nonthoracotomy cardioverter-defibrillator systems in patients with permanent endocardial pacemakers. Am Heart J. 1995 Jan;129(1):45–53. doi: 10.1016/0002-8703(95)90041-1. [DOI] [PubMed] [Google Scholar]
- Calkins H., Brinker J., Veltri E. P., Guarnieri T., Levine J. H. Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators. J Am Coll Cardiol. 1990 Sep;16(3):666–673. doi: 10.1016/0735-1097(90)90358-v. [DOI] [PubMed] [Google Scholar]
- Clemo H. F., Ellenbogen K. A., Belz M. K., Wood M. A., Stambler B. S. Safety of pacemaker implantation in patients with transvenous (nonthoracotomy) implantable cardioverter defibrillators. Pacing Clin Electrophysiol. 1994 Dec;17(12 Pt 1):2285–2291. doi: 10.1111/j.1540-8159.1994.tb02377.x. [DOI] [PubMed] [Google Scholar]
- Cohen A. I., Wish M. H., Fletcher R. D., Miller F. C., McCormick D., Shuck J., Shapira N., Delnegro A. A. The use and interaction of permanent pacemakers and the automatic implantable cardioverter defibrillator. Pacing Clin Electrophysiol. 1988 Jun;11(6 Pt 1):704–711. doi: 10.1111/j.1540-8159.1988.tb06020.x. [DOI] [PubMed] [Google Scholar]
- Epstein A. E., Kay G. N., Plumb V. J., Shepard R. B., Kirklin J. K. Combined automatic implantable cardioverter-defibrillator and pacemaker systems: implantation techniques and follow-up. J Am Coll Cardiol. 1989 Jan;13(1):121–131. doi: 10.1016/0735-1097(89)90559-7. [DOI] [PubMed] [Google Scholar]
- Furman S. Combined automatic implantable cardioverter-defibrillator and pacemaker systems... J Am Coll Cardiol. 1989 Jan;13(1):132–133. doi: 10.1016/0735-1097(89)90560-3. [DOI] [PubMed] [Google Scholar]
- Kim S. G., Furman S., Waspe L. E., Brodman R., Fisher J. D. Unipolar pacer artifacts induced failure of an automatic implantable cardioverter/defibrillator to detect ventricular fibrillation. Am J Cardiol. 1986 Apr 1;57(10):880–881. doi: 10.1016/0002-9149(86)90634-x. [DOI] [PubMed] [Google Scholar]
- Ong L. S., Barold S. S., Lederman M., Falkoff M. D., Heinle R. A. Cephalic vein guide wire technique for implantation of permanent pacemakers. Am Heart J. 1987 Oct;114(4 Pt 1):753–756. doi: 10.1016/0002-8703(87)90785-x. [DOI] [PubMed] [Google Scholar]
- Winkle R. A., Mead R. H., Ruder M. A., Gaudiani V. A., Smith N. A., Buch W. S., Schmidt P., Shipman T. Long-term outcome with the automatic implantable cardioverter-defibrillator. J Am Coll Cardiol. 1989 May;13(6):1353–1361. doi: 10.1016/0735-1097(89)90310-0. [DOI] [PubMed] [Google Scholar]