Abstract
Aims
We sought to evaluate the correlation between PCWP and LAP and to compare transmitral gradients obtained with LAP and PCWP in MS, before and after balloon mitral valvotomy (BMV).
Methods
Consecutive patients with MS for BMV were included in this prospective cohort study. Simultaneous PCWP and LAP were recorded followed by simultaneous left atrium–left ventricular (LA–LV) and pulmonary capillary wedge pressure–left ventricular (PCWP–LV) gradients before and after BMV.
Results
There were 30 patients with a mean age of 41 yrs (males 10 (33.3%), females 20 (66.7%)). There was no significant difference between mean LAP and mean PCWP before BMV (21.3 mmHg and 22.3 mmHg, respectively) or after BMV (15.3 mmHg and 17.3 mmHg, respectively). There was excellent correlation between mean PCWP and mean LAP before BMV (r = 0.95) (p < 0.001) and after BMV (r = 0.85) (p < 0.001). The phasic components of the pressures (a and v waves) of LAP and PCWP also showed good correlation before and after BMV. Further, transmitral gradients assessed by LA–LV and PCWP–LV pressures showed excellent correlation before BMV (r = 0.95) (p < 0.001) and after BMV (r = 0.95) (p < 0.001).
Conclusion
In patients with MS undergoing balloon valvotomy, PCWP shows good correlation with LAP. Transmitral gradients obtained with PCWP and LAP also correlate well after correction of phase lag in PCWP tracing. Hence, PCWP can be used for reliable measurement of transmitral gradient.
Keywords: Pulmonary capillary wedge pressure, Left atrial pressure, Balloon mitral valvotomy
1. Introduction
Simultaneous measurement of left atrial pressure (LAP) and left ventricular diastolic pressure (LVDP) is the ideal method for determination of the mean mitral valve gradient in patients with mitral stenosis (MS). However, many invasive laboratories use pulmonary capillary wedge pressure (PCWP) instead of LAP because of the inherent risks of transseptal catheterization.1, 2 It has remained controversial ever since, with some investigators attesting to the concept that PCWP accurately reflects LAP3, 4 but others disagreeing, particularly in the setting of mitral valve disease or raised pulmonary vascular resistance.5, 6, 7, 8
Two previous studies have argued against the use of PCWP in patients with MS and prosthetic mitral valves, because a clinically significant overestimation of true transmitral gradient may result.9, 10 This was attributed to inherent delay in PCWP traces.10 In a subsequent study, it was observed that time-adjusted PCWP accurately reflects LAP; however, transmitral gradient was overestimated even after correcting the phase lag in PCWP traces.5 Without correction for the delay in PCWP trace, there was 53% overestimation of transmitral gradient. Correction of this delay decreased the error, though some overestimation persisted.11 However, recently in a study by Krishnamurthy et al., it was found that after correction for the phase lag, transmitral gradient obtained using PCWP was comparable to that obtained using LAP both before and after balloon mitral valvotomy (BMV).12
The present study was prompted by the disparities seen in previous studies. Our study aimed at evaluating the correlation between PCWP and LAP in patients with MS in normal sinus rhythm or atrial fibrillation. The transmitral gradients obtained with LAP and that obtained with PCWP were also compared. Assessments were done both before and after BMV.
2. Materials and methods
In this prospective cohort study, we included consecutive patients with MS admitted to a tertiary care hospital for BMV during a period of one year. Exclusion criteria were significant chronic respiratory illness or aortic valve disease.
Baseline data were collected regarding demographic and clinical characteristics, electrocardiogram, chest X-ray manifestations, and echocardiographic features. Procedure was done in fasting state. Through femoral vein access, a 6F Cournand catheter was positioned in the pulmonary artery under fluoroscopic guidance and pulmonary artery pressures were recorded. The catheter was then pushed into the left lower pulmonary artery in each case as far as possible during deep inspiration and PCWP was obtained. For measuring LVDP, a 6F pigtail catheter was placed retrogradely into the left ventricle. Catheter over-damping and under-damping were avoided and the shortest possible transducer connection was used. PCWP was accepted only when: (1) the pressure contour was distinctly different from that recorded in the pulmonary artery on a pullback determination and both the phasic and mean wedge pressures were lower than that of the pulmonary artery; (2) there was fluoroscopic demonstration of wedge position; and (3) there were two separate a and v waves in the tracing.
Transseptal left heart catheterization was performed percutaneously through the right femoral vein using Brockenbrough needle and a transseptal catheter introducer set. An 8F transseptal sheath was placed in the left atrium. Simultaneous PCWP and LAP (mean and phasic) were recorded. Following this, simultaneous LA–LV and PCWP–LV gradients were recorded. Patients underwent BMV by the method described by Inoue et al.13 Similar measurements were repeated after BMV.
To correct the phasic delay in PCWP trace, pressure tracing was manually shifted so that the peak of the v wave of PCWP coincided with the descending limb of the left ventricular pressure tracing. The mean transvalvular pressure gradients were determined from the measured diastolic filling periods after planimetry of three consecutive beats (in patients with sinus rhythm) or 5 consecutive beats (in patients with atrial fibrillation).
Statistical analysis was performed using Statistical Package for Social Science software (SPSS Inc Chicago, Illinois version 18). Qualitative variables, expressed as numbers and percents, were compared by the Chi-square test. A p-value less than 0.05 was considered statistically significant. Correlation was assessed with Pearson's correlation coefficient.
3. Results
There were 30 patients with a mean age of 41 yrs [males 10 (33.3%), females 20 (66.7%)]. Baseline patient characteristics are listed in Table 1. There was no significant difference between mean LAP (21.27 ± 9.1 mmHg) and mean PCWP (22.43 ± 9.5 mmHg) before BMV. Post BMV also, similar result was obtained with a mean LAP (15.3 ± 7.9) and mean PCWP (17.23 ± 7.6). There was good correlation between the mean PCWP and mean LAP before BMV (r = 0.95) (p < 0.001) and after BMV (r = 0.85) (p < 0.001). The phasic components of the pressures of LAP and PCWP also showed good correlation before and after BMV. Comparison of mean LAP, mean PCWP, and phasic components is shown in Table 2. Furthermore, transmitral gradients assessed by LA–LV and PCWP–LV pressures showed excellent correlation before BMV (r = 0.95) (p < 0.001) and after BMV (0.95) (r = p < 0.001). Comparison of mean transmitral gradients obtained with PCWP and LAP components is shown in Table 3. A representative tracing is displayed in Fig. 1.
Table 1.
Baseline characteristics (n = 30).
| Age, yrs, mean (SD) | 41.5 (13.5) |
| Male/female n (%) | 10 (33.3)/20 (66.7) |
| Atrial fibrillation, n (%) | 6 (20) |
| Mitral valve area, cm2, mean (SD) | 0.913 (0.14) |
| Left atrial diameter, mm, mean (SD) | 45.2 (8.07) |
SD: standard deviation.
Table 2.
Comparison of PCWP and LAP.
| LAP (mmHg) | PCWP (mmHg) | Correlation | p value | |
|---|---|---|---|---|
| Before BMV | ||||
| a wave mean (SD) | 20.87 (14.8) | 20.8 (13.8) | 0.94 | <0.001 |
| v wave mean (SD) | 27.5 (12.2) | 27.67 (11.6) | 0.924 | <0.001 |
| Mean (SD) | 21.27 (9.1) | 22.43 (9.5) | 0.958 | <0.001 |
| After BMV | ||||
| a wave | 14.4 (9.7) | 17.27 (10.9) | 0.848 | <0.001 |
| v wave | 21.36 (10) | 21.67 (8.3) | 0.906 | <0.001 |
| Mean | 15.3 (7.9) | 17.23 (7.6) | 0.850 | <0.001 |
BMV: balloon mitral valvotomy; PCWP: pulmonary capillary wedge pressure corrected for phase lag; LAP: left atrial pressure; SD: standard deviation.
Table 3.
Comparison of transmitral gradients assessed by PCWP and LAP.
| LAP–LVDP (mmHg) | PCWP–LVDP (mmHg) | Correlation | p value | |
|---|---|---|---|---|
| Before BMV, MG (SD) | 14.6 (6.7) | 16.46 (6.3) | 0.950 | <0.001 |
| After BMV, MG (SD) | 10.22 (5.3) | 11.50 (5.3) | 0.951 | <0.001 |
BMV: balloon mitral valvotomy; PCWP: pulmonary capillary wedge pressure corrected for phase lag; LAP: left atrial pressure; MG: mean gradient; LVDP: left ventricular diastolic pressure; SD: standard deviation.
Fig. 1.
Representative hemodynamic tracings. (A) Simultaneous left atrial and pulmonary capillary wedge pressure tracings. (B) Simultaneous left atrial and left ventricular pressure tracings. (C) Simultaneous pulmonary capillary wedge and left ventricular pressure tracings.
4. Discussion
The concept of PCWP as a reflection of LAP was introduced half a century ago.14 It has remained controversial ever since, with some investigators attesting to the accuracy of the relation3, 4 but others disagreeing, particularly in the setting of mitral valve disease or raised pulmonary vascular resistance.5, 6, 7, 8
Luchsinger et al.15 investigated 11 patients with mitral valve disease and found that mean PCWP consistently exceeded mean LAP. Other investigators also questioned the accuracy of the relation between PCWP and LAP.16 In a retrospective analysis of 700 cases by Walston and Kendell,17 it was found that correlation between PCWP and LAP was lower in MS than in other disorders. In our study, mean PCWP and mean LAP correlated well both before and after BMV. The correlation was good for the phasic components (a and v waves) also.
Two studies have argued against the use of PCWP in patients with MS and prosthetic mitral valves because a clinically significant overestimation of the true transmitral gradient may result. Hosenpud et al. noted that when LVDP was measured against PCWP rather than transseptal LAP, mean diastolic transmitral gradient was overestimated.9 This difference, later by Shoenfeld et al, was attributed to inherent delay in PCWP traces.10 Subsequently, Lange et al. in a study of 10 patients tried to rectify this delay in PCWP trace. Here, the inherent delay in PCWP trace was compensated by using a time-adjusted PCWP.5 This study concluded that phase-adjusted PCWP accurately reflected LAP. However, transmitral gradient was overestimated even after correcting the phase delay. Hildick-Smith et al.18 found that mean PCWP correlated well with LAP in MS. However, transmitral gradient assessed using PCWP varied significantly from that assessed using LAP due to the phasic delay in PCWP trace and the dampened post v-wave descent. Nishimura et al.11 agreed with these findings and demonstrated that without correction for the delay in PCWP trace, there was 53% overestimation of transmitral gradient. Correction of this delay decreased the error, but still some overestimation persisted.
In contrast, a recent study by Krishnamurthy et al.12 found that after correction for the phase lag, transmitral gradient obtained with PCWP was comparable to that obtained using LAP, both before and after BMV. Another recent study by Nagy et al.19 found that PCWP accurately reflects both normal and elevated LAP. In our study, transmitral gradients obtained using phase lag adjusted PCWP was comparable to that obtained using LAP. This finding in our study agreed with the study by Krishnamurthy et al. We eliminated the phase lag of PCWP by time correction. Our study evaluated gradients both before and after BMV in the whole sample.
There were some limitations in our study. We did not use the ideal method of oximetric confirmation for the catheter wedging, although we relied on other criteria for accepting the wedge position. Earlier studies had shown that discrepancy between adjusted PCWP and LAP may be greater in those with substantial pulmonary hypertension.20 Even though our data demonstrate that adjusted PCWP allows reliable measurement of the transvalvular pressure gradient, this issue of discrepancy with pulmonary hypertension was not addressed in our study. Further studies are needed to demonstrate whether good correlation exists between phase lag adjusted PCWP and LAP in patients with MS and concomitant severe pulmonary hypertension.
5. Conclusion
In patients with MS, PCWP shows good correlation with LAP. Transmitral gradients obtained with phase-adjusted PCWP and LAP also correlate well before and after BMV. Hence, PCWP can be used for reliable measurement of transmitral gradient.
Conflicts of interest
The authors have none to declare.
References
- 1.Grossman W. 3rd ed. Lea & Febiger; Philadelphia: 1986. Cardiac Catheterization and Angiography; pp. 71–75. 145-8. [Google Scholar]
- 2.Conti C.R., Ross R.S. The risks of catheterization (editorial) Am Heart J. 1969;78:289–291. doi: 10.1016/0002-8703(69)90036-2. [DOI] [PubMed] [Google Scholar]
- 3.Ames W.H., Theilen E.O., Ehrenhaft J.L., Culbertson J.W. Study of left atrial pressures in relation to pulmonary capillary pressure waves in patients with mitral stenosis. J Clin Invest. 1952;31:614–619. [Google Scholar]
- 4.Connoly D.C., Kirklin J.W., Wood E.H. The relationship between pulmonary artery wedge pressure and left atrial pressure in man. Circ Res. 1953;2:434–440. doi: 10.1161/01.res.2.5.434. [DOI] [PubMed] [Google Scholar]
- 5.Lange R.A., Moore D.M., Jr., Cigarroa R.G., Hillis L.D. Use of pulmonary capillary wedge pressure to assess severity of mitral stenosis: is true left atrial pressure needed in this condition? J Am Coll Cardiol. 1989;13:825–831. doi: 10.1016/0735-1097(89)90223-4. [DOI] [PubMed] [Google Scholar]
- 6.Ankenney J.L. Further experimental evidence that pulmonary capillary pressures do not reflect cyclic changes in left atrial pressure. Circ Res. 1953;1:58–63. doi: 10.1161/01.res.1.1.58. [DOI] [PubMed] [Google Scholar]
- 7.Haddy F.J., Alden J.F., Ferrin A.L., Hannon D.W., Adams W.L., Baranofsky I.D. An evaluation of wedge pressures in dogs under conditions of normal and elevated pulmonary vascular resistance. Circ Res. 1953;1:157–160. doi: 10.1161/01.res.1.2.157. [DOI] [PubMed] [Google Scholar]
- 8.Murphy J.P. Inaccuracy of wedge pressure as an index of pulmonary capillary pressure. Circulation. 1958;17:199–203. doi: 10.1161/01.cir.17.2.199. [DOI] [PubMed] [Google Scholar]
- 9.Hosenpud J.D., McAnulty J.H., Morton M.J. Overestimation of mitral valve gradients obtained by phasic pulmonary capillary wedge pressure. Catheter Cardiovasc Diagn. 1983;8:283–290. doi: 10.1002/ccd.1810090307. [DOI] [PubMed] [Google Scholar]
- 10.Schoenfeld M.H., Paiacios I.F., Hutter A.M., Jr., Jacoby S.S., Block P.C. Underestimation of prosthetic mitral valve areas: role of transseptal catheterization in avoiding unnecessary repeat mitral valve surgery. J Am Coll Cardiol. 1985;5:1387–1392. doi: 10.1016/s0735-1097(85)80353-3. [DOI] [PubMed] [Google Scholar]
- 11.Nishimura R.A., Rihal C.S., Tajik A.J., Holmes D.R. Accurate measurement of the transmitral gradient in patients with mitral stenosis: a simultaneous catheterization and Doppler echocardiographic study. J Am Coll Cardiol. 1994;24:152–158. doi: 10.1016/0735-1097(94)90556-8. [DOI] [PubMed] [Google Scholar]
- 12.Krishnamurthy K.M., Radhakrishnan S., Shrivastava S. Simultaneous echocardiographic and catheterisation gradients and mitral valve area during balloon mitral valvulolasty. Indian Heart J. 1999;51:410–413. [PubMed] [Google Scholar]
- 13.Inoue K., Owani T., Nakamura T., Kitimura F., Miyamoto N. Clinical application of trans venous mitral commissurotomy by a new balloon catheter. J Thoracic Cardiovasc Surg. 1984;87:394–402. [PubMed] [Google Scholar]
- 14.Hellems H.K., Haynes F.W., Dexter L., Kianey T.D. Pulmonary capillary pressure in animals estimated by venous and arterial catheterization. Am J Physiol. 1948;155:98–105. doi: 10.1152/ajplegacy.1948.155.1.98. [DOI] [PubMed] [Google Scholar]
- 15.Luchsinger P.C., Seipp H.W., Patel D.J. Relationship of pulmonary artery wedge pressure and left atrial pressure in man. Circ Res. 1962;11:315–318. doi: 10.1161/01.res.11.2.315. [DOI] [PubMed] [Google Scholar]
- 16.Verel D., Stentiford N.H. Comparison of left atrial pressure and wedge pulmonary capillary pressure. Br Heart J. 1970;32:99–102. doi: 10.1136/hrt.32.1.99. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Walston A., II, Kendell M.E. Comparison of pulmonary wedge and left atrial pressure in man. Am Heart J. 1973;86:159–164. doi: 10.1016/0002-8703(73)90239-1. [DOI] [PubMed] [Google Scholar]
- 18.Hildick-Smith D.J., Walsh J.T., Shapiro L.M. Pulmonary capillary wedge pressure in mitral stenosis accurately reflects mean left atrial pressure but overestimates transmitral gradient. Am J Cardiol. 2000;85–87:512–515. doi: 10.1016/s0002-9149(99)00785-7. [DOI] [PubMed] [Google Scholar]
- 19.Nagy A.I., Venkateshvaran A., Dash P.K. The pulmonary capillary wedge pressure accurately reflects both normal and elevated left atrial pressure. Am Heart J. 2014;167:876–883. doi: 10.1016/j.ahj.2014.01.012. [DOI] [PubMed] [Google Scholar]
- 20.Levin R.I., Glassman E. Left atrial-pulmonary artery wedge pressure relation: effect of elevated pulmonary vascular resistance. Am J Cardiol. 1985;55:856–857. doi: 10.1016/0002-9149(85)90176-6. [DOI] [PubMed] [Google Scholar]

