Skip to main content
Nuclear Medicine and Molecular Imaging logoLink to Nuclear Medicine and Molecular Imaging
. 2016 Jan 26;50(2):104–111. doi: 10.1007/s13139-015-0392-7

Combination Radioimmunotherapy Approaches and Quantification of Immuno-PET

Jin Su Kim 1,2,3,
PMCID: PMC4870465  PMID: 27275358

Abstract

Monoclonal antibodies (mAbs), which play a prominent role in cancer therapy, can interact with specific antigens on cancer cells, thereby enhancing the patient’s immune response via various mechanisms, or mAbs can act against cell growth factors and, thereby, arrest the proliferation of tumor cells. Radionuclide-labeled mAbs, which are used in radioimmunotherapy (RIT), are effective for cancer treatment because tumor associated-mAbs linked to cytotoxic radionuclides can selectively bind to tumor antigens and release targeted cytotoxic radiation. Immunological positron emission tomography (immuno-PET), which is the combination of PET with mAb, is an attractive option for improving tumor detection and mAb quantification. However, RIT remains a challenge because of the limited delivery of mAb into tumors. The transport and uptake of mAb into tumors is slow and heterogeneous. The tumor microenvironment contributed to the limited delivery of the mAb. During the delivery process of mAb to tumor, mechanical drug resistance such as collagen distribution or physiological drug resistance such as high intestinal pressure or absence of lymphatic vessel would be the limited factor of mAb delivery to the tumor at a potentially lethal mAb concentration. When α-emitter-labeled mAbs were used, deeper penetration of α-emitter-labeled mAb inside tumors was more important because of the short range of the α emitter. Therefore, combination therapy strategies aimed at improving mAb tumor penetration and accumulation would be beneficial for maximizing their therapeutic efficacy against solid tumors.

Keywords: Monoclonal antibody, Radioimmunotherapy, Immuno-PET, Tumor microenvironment

Introduction

Monoclonal antibodies (mAbs), which play a prominent role in cancer therapy, can interact with specific antigens on cancer cells, thereby enhancing the patient’s immune response via various mechanisms, or mAbs can act against cell growth factors and, thereby, arrest the proliferation of tumor cells. Radionuclide-labeled mAbs, which are used in radioimmunotherapy (RIT), are effective for cancer treatment because tumor associated-mAbs linked to cytotoxic radionuclides can selectively bind to tumor antigens and release targeted cytotoxic radiation [13]. Iodine-131 (131I)-labeled mAbs has been widely used in the successful treatment of patients with lymphoma in nuclear medicine [46]. Recently, α-emitter-labeled RIT is considered a promising therapeutic strategy, because α emitters provide high linear energy transfer to tumors within a short range [7].

Although the concept of RIT may appear straightforward, in practice it has been difficult to achieve substantial clinical success, particularly in solid tumors due to the limited delivery of mAb into tumor [8, 9]. Furthermore, limited delivery of mAb would be more problematic in therapy when α-emitter-labeled RIT was performed because of the short range of α particles. In this paper, delivery strategies for mAb in RIT, and the imaging characteristics of some currently and widely used radioisotopes such as iodine-124 (124I), zirconium-89 (89Zr), and copper-64 (64Cu) are discussed. Macro-level and microcellular-level dosimetry strategies are also described.

Immuno-PET

Immunological positron emission tomography (immuno-PET), which is the combination of PET with mAb, is an attractive option for improving tumor detection and mAb quantification. Immuno-PET has advantages over conventional radioimmunoscintigraphy in terms of accurate quantification of the mAb from the images [10, 11]. The radioisotopes most often used for immuno-PET are: 64Cu (half-life [t1/2], 12.7 h), and 124I (t1/2, 4.2 days) [12]. Although 64Cu was widely used for the clinical imaging of mAb [13, 14], t1/2 of 64Cu is too short to prove effective with the slow pharmacokinetic profile of mAb in humans. The accumulation of mAb in tumors is a slow process, as is their clearance from the blood (t1/2, 50–90 h) [10]. Slow process of mAb delivery to tumor was due to limited transport of mAb, which was described in the “limited transport of mAb to tumor” section in detail. Table 1 shows the physical characteristics of 89Zr, 124I and 18F. PET radionuclides with a relatively long t1/2, such as 124I (t1/2, 4.2 days) and 89Zr (t1/2, 78.41 h), would be more suitable for immuno-PET than those with a short t1/2.

Table 1.

Physical characteristics of 89Zr, 124I and 18F

Properties 89Zr 124I 18F
Half-life 78.4 h 4.18 day 109.8 min
Mean β+ energy 0.40 MeV 0.83 MeV 0.25 MeV
Mean β+ range in water 1.23 mm 3.48 mm 0.62 mm
Single γ energy 909 keV (99.9 %)
1,657 keV (0.1 %)
1,713 keV (0.8 %)
602 keV (61 %)
723 keV (10 %)
1,691 keV (11 %)
β+ branching ratio 23 % 23 % 97 %

124I has been used for immuno-PET, but its imaging characteristics are limited in terms of spatial resolution and image quality. In addition, in vivo dehalogenation of 124I is the main limiting factor [15]. The spatial resolution of 124I is poorer than that of 18F, because it has a longer β+ range than that of 18F (β+ range in water, 3.8 and 0.66 mm for 124I and 18F, respectively). Jin Su Kim’s group in Korea Institute of Radiological and Medical Sciences (KIRAMS) reported that the spatial resolution of 124I was reduced by 19 % compared with that of 18F on the ECAT HR+ scanner. The PET image quality with this radionuclide is poor owing to the cascade of γ photons and low β+ branching ratio (β+ branching ratio of 124I, 23 %) [16, 17]. High-energy γ photons (602, 723, and 1691 keV) are emitted in a cascade with the β+ The major interference is caused by γ photons with energy levels of 602 keV because their energy level falls within the standard energy window of most PET scanners, which will detect these photons as additional background noise or interference. In addition, the 602-keV γ photons have a high branching ratio of approximately 61 % and, as a result, the dead time of the system is also increased, while its count-rate performance is reduced [16]. Cascade γ photons contribute to background image noise in 124I-PET and, therefore, this background interference must be corrected to improve the image quality. Moreover, Preylowski et al. [16] reported that the image quality could be improved after correcting the background noise caused by the higher energy γ photons (602 and 732 keV). The correction of higher energy of γ photons referred to as “prompt γ correction” in the study by Preylowski et al. [16], was implemented in the Siemens Biograph mCT scanner. Preylowski et al.’s algorithm calculated the distribution of prompt coincidence using the convolution prompt γ kernel with attenuation correction, and for random coincidences it also corrects acquired data. Kim’s group developed a prompt γ correction method for 124I-PET in a sinogram space [18]. The fraction of prompt γ was derived using comparison of β+ branching ratio corrected sensitivity. Briefly, the difference between branching ratio corrected sensitivity of 124I and that of 18F was a fraction of prompt γ [18]. According to the result, the single γ fraction was 3 % for 350-550 keV, 24 % for 350-650 keV, and 31 % for 350-750 keV. The higher single γ fraction for a wider energy window was due to greater inclusion of 602-keV γ within the energy window. Therefore, background noise count due to higher energy of γ photons would differ from energy window width. According to the Jin Su Kim’s method, “scatter distribution × single γ photon fraction” is the portion of background count due to higher single γ photon which could be calculated using the obtained scatter sinogram and measured branching ratio corrected sensitivity [18]. Recently, Jin Su Kim’s group compared the effect of different filter and reconstruction methods for 124I quantification on Siemens Inveon PET scanner [19, 20].

89Zr (t1/2, 78.41 h) is also an ideal radioisotope for immuno-PET [2123]. However, 89Zr has also poor imaging characteristics because of low spatial resolution and image quality. Jin Su Kim’s group in KIRAMS, Korea, reported that the spatial resolution of 89Zr was approximately 9 % lower than that of 18F was using the Siemens Biograph Truepoint TrueV scanner (4.5 and 4.1 mm for 89Zr and 18F, respectively) [24]. The predicted spatial resolution of 124I was 5.5 mm on the Siemens Biograph Truepoint TrueV scanner [24]. The value of the β+ range was 1.23, 0.62, and 1.23 mm for 89Zr, 18F, and 124I, respectively. The low spatial resolutions of 89Zr and 124I were due to their long β+ ranges. The degradation of the spatial resolution was also observed with animal dedicated PET scanners. According to the report by Disselhorst’s group, the spatial resolution of 89Zr was degraded by 10 % compared with that of 18F on the Siemens Inveon PET scanner (1.99 and 1.81 mm for 89Zr and 18F, respectively) [25]. The β+ branching ratio of 89Zr was 23 %, which is lower than that of 18F, but similar to that of 124I. Furthermore, the low β+ branching ratio of 89Zr degraded the image quality compared with that of 18F [24]. Figure 1 shows the transaxial images of the National Electrical Manufacturers Association (NEMA) IEC phantom for the comparison of image quality between 89Zr and 18F. In addition, 89Zr emitted 909 keV of γ photons, which falls outside the energy window of clinical PET scanners, but the associated higher energy is still likely to cause Compton scattering. Furthermore, there was the possibility that the scattered photons would be included within the energy window, and produce some degree of noise [24]. Another problem associated with the 909-keV energy of γ photons was the radiation hazard, which was crucial for internal dosimetry and required the necessary provision of radiation protection for both patients and workers. Although there were limitations such as poor spatial resolution and image quality of the immuno-PET when 89Zr or 124I was used, they were a suitable match for the t1/2 of the mAb and, therefore, could provide a tool for monitoring the targeting of mAb to tumors.

Fig. 1.

Fig. 1

Transaxial images of NEMA IEC phantom using (a) 89Zr images and (b) 18F. Images were reconstructed using FBP. This figure is reprinted from Lee et al. [24]

Radioimmunotherapy

RIT such as those using 131I tositumomab (Bexxar; GlaxoSmithKline, Philadelphia,PA, USA) [2628], 90Y ibritumomabtiuxetan (Zevalin; Biogen Idec, Cambridge, MA, USA) [29, 30] and 131I rituximab (Rituxan; Genentech, South San Francisco, CA, USA) were used for the treatment of hematological tumors. Recently, 131I tositumomab was withdrawn for commercial reasons [31]. Regarding RIT for solid tumors, trastuzumab (Herceptin; F. Hoffmann-La Roche, Basel, Switzerland), cetuximab (Erbitux; ImClone Systems, New York, USA), bevacizumab (Avastin; Genentech, South San Francisco, CA, USA) and panitumumab (Vectibix; Amgen, Taos, NM, USA) were used for the treatment.

For the RIT, lutetium-177 (177Lu) (t1/2, 6.7 days; Emax, 497 keV; rangemax in water, 2.1 mm), yttrium-90 (90Y) (t1/2, 2.7 days; Emax, 2,270 keV; rangemax in water, 12.0 mm), and 131I (t1/2, 8 days, Emax, 606 keV, rangemax in water, 2.4 mm) were used. 90Y is a pure β emitter, which requires a γ-emitting surrogate (111In) for clinical imaging [32]. Glatting et al. [33] and Lhommel et al. [34] reported the feasibility of 90Y as a PET radionuclide. However, because, the abundance of β+ level of 90Y was extremely low (0.003 %), and Bremsstrahlung photons were emitted during the PET acquisition [35], PET imaging with 90Y was possibly due to inclusion of Bremsstrahlung photons during PET acquisition. The 90Y particle has higher energy and longer particle range, leading to more radioactivity in the tumor cell per peptide molecule and superior crossfire through the tumor, which is especially advantageous in large tumors and tumors with heterogeneous receptor distribution. Furthermore, 177Lu particles have lower energy and smaller particle range than 90Y does, leading to better absorption in small tumors [32, 36, 37]. Frost et al. [32] showed that the mean absorbed dose of 177Lu by the tumor was more than twofold higher than that for 90Y following the administration of the same level of radioactivity.

The use of auger electrons [3840] or α particles was feasible owing to the high linear energy transfer radiation within a short range. Alpha particles such as astatine-211 (211At) (t1/2, 7.2 h), bismuth-213 (213Bi) (t1/2, 46 min), actinium-225 (225Ac) (t1/2, 10 days), bismuth-212 (212Bi) (t1/2, 60 min), radium-233 (233Ra) (t1/2, 11 days), terbium-149 (149Tb) (t1/2, 4 h), and fermium-255 (255Fm) (t1/2, 20 h) [4145] would be possible for RIT. 211At is of particular interest because of its high linear energy transfer (5,869 and 7,450 MeV α particles), biologically relevant t1/2, and absence of α-emitting daughters. Auger electron emitting radionuclides that could be used as theranostic agents are gallium-67 (67Ga), bromine-80m (80mBr), 89Zr, niobium-90 (90Nb), technetium-99m (99mTc), indium-111 (111In), tin-117m (117mSn), antimony-119 (119Sb), iodine-123 (123I), iodine-125 (125I), platinum-195m (195mPt), and thallium-201 (201Tl).

Intranuclear delivery of Auger electron-emitting constructs results in relative biological efficacy similar to that of α emitters but with a comparatively reduced crossfire effect, making them more suitable for single-cell irradiation than the α emitters. Auger electron emitters such as 125I have a high linear energy transfer and short range of emission (<10 μm), making them suitable for treating micrometastases while sparing normal tissues [3840, 46, 47]. In addition, the radiation emitted during the nuclear decay can be used for imaging either using SPECT with γ rays or Bremsstrahlung photons or PET, thereby rendering Auger-electron-emitting radionuclides as ideal theragnosis agents [48, 49]. Kiess’s group at John’s Hopkins University, used a highly specific small molecule targeting the prostate-specific membrane antigen to deliver 125I to prostate cancer cells [46]. Hasegawa’s group at the National Institute of Radiological Science, Japan, reported that 111In trastuzumab modified with nuclear-localizing signal peptides efficiently delivered an Auger electron emitter 111In into the cell nucleus and, therefore, is a promising radiopharmaceutical in Auger electron RIT suitable for targeted killing of HER2-positive cancer cells [39].

Falzone’s group at the University of Oxford, UK evaluated the characteristics of Auger electrons in terms of S values, the effect of cellular geometry and eccentric cell or nucleus arrangements on S values, dose-point kernels (DPKs), and energy deposition on a DNA scale compared with an α emitter, 223Ra. The DPK of 223Ra and the Auger electron emitters showed that with respect to the energy deposited in spheres of DNA dimensions, only the higher-mass-number Auger electron emitters deposited comparable amounts of energy. However, compared with a mono-energetic 5.77-MeV α particle, the major advantage of Auger electron emitters is that they have a range of less than 11 nm [48, 50].

Macro-Level and Microcellular-Level Dosimetry

The absorption of energy from ionizing radiation can cause damage to living tissues, and this effect is used as an advantage in radionuclide therapy. One of the most important factors in the assessment of the effects of radiation on an organ is the amount of radiation energy deposited in that organ. The calculation of radiation energy deposited by internal radionuclides is the focus of internal radiation dosimetry. Currently, whole-body dosimetry was used for RIT, and has proven to be a reliable method for determining the patient-specific maximally tolerated therapeutic radiation dose required to maximize efficacy while minimizing organ and bone marrow toxicity [51, 52]. The Medical Internal Radiation Dosimetry (MIRD) formulation assumed that radioactivity and energy was uniformly distributed and deposited within each organ. This assumption can cause significant errors in the calculated dose as a result of nonpenetrating radiation (e.g., Auger electrons) when the activity was taken up in specific regions or cell types within an organ. Therefore, local radionuclide concentrations and the subsequently absorbed dose can be much higher than average calculations of quantities absorbed by organs might suggest [51]. Dewaraja et al. [53] developed the patient-specific, three-dimensional (3D) method for absorbed dose calculation. Although the mean dose estimates are quite adequate for diagnostic applications, greater accuracy is required for therapeutic applications and patient-specific 3D calculations. With the 3D dosimetry, the minimum and maximum doses, as well as dose nonuniformity can be estimated. Jin Su Kim’s group in KIRAMS, Korea, performed imaging and therapy using 131I trastuzumab and a pinhole collimator attached to a conventional gamma camera for human use in a mouse model. Mouse dosimetry and prediction of human dosimetry could be used to provide data for the safety and efficacy of newly developed therapeutic schemes [54]. Meredith et al. [55] reported the first use of dosimetry in human α emitter labeled RIT with 212Pb TCMC-trastuzumab. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and non-targeted cells for accurate dosimetry when α-emitter-labeled RIT was performed [56]. Recently, a single-particle digital autoradiography named α camera was developed for the quantification of α particle for targeted radionuclide therapy. Miller et al. [56, 57] developed an α camera called the iQID camera, which is a scintillator-based radiation detection system that images and identifies α particle emissions spatially and temporally using CCD-CMOS cameras and high-performance computing hardware. The iQID camera technique was used for the quantitative imaging of 211At activity distributions in cryosections of mouse and dog tissue samples [56]. Figure 2. shows the distribution of 211At 1F5 (anti CD20 mAb) in the mouse kidney. Frost et al. [58] reported the result of using 211At localization and small-scale dosimetry for optimizing the mAb dose for 211At RIT using α-imaging systems.

Fig. 2.

Fig. 2

211At-1F5 (anti-CD20 mAb) micro-biodistribution for the mouse which was acquired using an α camera. This figure was reprinted from Miller et al. [56]

Limited Transport of mAb into Tumor

RIT remains a challenge because of the limited delivery of mAb into tumors. The transport and uptake of mAb into tumors is slow and heterogeneous [59]. Although, a large amount of mAb intravenously injected, very little reaches the tumor and a large portion remains circulating in the plasma or is taken up even in normal tissues, thereby irradiating and killing healthy cells over time [60]. Uptaken and penetrated mAb was not evenly distributed within the tissue. Monoclonal antibodies bind to their targets much faster than they diffuse through tissue [61]. Only cells adjacent to blood vessels was more targeted even in well-vascularized regions [62]. The steps associated with targeting mAb to tumors are blood flow to the tumor, extravasation across the blood vessel wall, diffusion into the tissue, and binding to the target [61]. Blood flow occurs in the order of minutes, while binding is completed in several seconds. While the rates of these processes can significantly affect the distribution of the mAb in the tumor, but they do not all have a major impact on the total amount localized in the tissue [61]. Extravasation across the blood vessel wall is the rate-limiting step in uptake. Monoclonal antibodies are transported into tumors by convection and diffusion. Convection of materials in fluids such as mAb in a tumor occurs by the movement of that liquid. This flow occurs when there is a difference in pressure, which forces the fluid from an area of high pressure to that of low pressure. Diffusion occurs as a result of the random Brownian motion of molecules in a liquid. The distance of mAb diffusion is proportional to the square root of time [59, 6264].

The time required to deliver mAbs to the tumor vasculature can be calculated by measuring the blood flow. The time for blood flow can be calculated as follows

Bloodflowtime=1/Q1Ht

where Q is the flow rate of the blood in the tumor (volume of whole blood per volume of tumor per time), and Ht is the hematocrit. The extravasation rate of mAb is very slow compared with measured flow rates and, therefore, the permeability typically has a greater impact on the uptake [60].

The time it takes for the mAbs to penetrate a specified volume of a tumor is calculated as:

Extravasationtime=V/PS

where P is the permeability and S/V is the blood vessel surface area to tumor volume ratio [60].

Convection within the tissue are small compared with the rate of diffusion and, therefore, diffusive movement mainly drives the interstitial transport. Using Fick’s law, diffusion time is calculated as:

DR2/Dε

where R is the distance the mAb must diffuse, D is the diffusion coefficient between the cells, and ε is the void fraction [60].

Extravasation and diffusion were limiting step for delivery of mAbs. According to the mathematical analysis, estimated permeability in step of extravasation was 0.003 μm/s for mAb and 1 μm/s for FDG and diffusion rate was 10 μm2/s for mAb and 500 μm2/s for FDG [64]. The estimated time-based mathematical analysis for delivering the mAb to the tumor was 10 min for convection, 18 h for extravasation, 24 min for diffusion, and 12 s for binding [59, 60, 64].

Enhancement of mAb Penetration into Tumor

The tumor microenvironment contributed to the limited delivery of the mAb [65]. The limited targeting and insufficient dose delivery of mAb to solid tumor were caused by abnormal structure of tumor vessel, highly fibrotic or desmoplastic tumor, absence of functional lymphatics, and high fluid permeability [59, 6668]. Tumor cells are surrounded by layers of extracellular matrix (ECM) proteins (e.g., collagen, elastin, fibronectin, and laminin), which largely prevents the tumor vasculature from penetrating the tumor nests. Tumor-derived ECM plays an important role in inhibiting the penetration and dispersion of cancer therapeutic agents within tumor masses and has been implicated in the resistance of solid tumors to therapy [69]. Beyer et al. [69] observed extensive tumor ECM and intercellular junctions in patients with breast cancer and in xenograft models [70].

Targeting tumors with mAb-based therapeutics is a complex task that presents multiple kinetic barriers. Monoclonal antibody internalization and clearance inhibit uptake both in solid tumors limited by tumor vascular permeability and in micrometastases limited by diffusion [61, 69]. To improve the efficacy of RIT, binding-site barriers need to be surmounted to enhance the distribution of mAb uniformly in tumors. The binding-site barriers can cause non-uniform distribution of mAb in the tumor microenvironment because radiolabeled mAbs bind primarily to the tumor cells nearest to the vasculature. This hinders the uniform distribution of radiolabeled mAbs throughout the tumor unless the dose of mAbs administered is at a concentration that can saturate all antigens on the tumor cells. Nonuniform microdistribution of mAb leads to a marked difference in individual cell survival across the tumor [71]. Therefore, although RIT was shown to be effective against hematological tumors, solid tumors were less responsive due to insufficient dose delivery and radiation resistance [72]. Numerous solutions such as fractionated dosing [73] and mAb pretargeting methods [74], as well as recombinant immunotoxins [75], were introduced in attempts to improve the efficacy of RIT against solid tumors. Yun’s group at Hanynag University, Korea used ECM-degrading oncolytic adenovirus to achieve a desirable therapeutic outcome in pancreatic cancer [76]. Decorin modulates tumor ECM production and, therefore, has an integral role in the degradation or downregulation of tumor ECM constituents or both. The decorin-based approach would be effective for increasing mAb penetration into solid tumors [69, 77]. Chang H. Paik’s group at NIH, USA used paclitaxel (Taxol) [8] or pulsed high-intensity focused ultrasound to enhance the therapeutic efficacy of RIT against solid tumors [9, 78]. Furthermore, combined RIT strategies could be used to cure solid tumors in patients if the accumulation and penetration of mAb into the tumor microenvironment could be increased, thereby sensitizing more tumor cells to the radiation from the radiolabeled mAb.

Regarding microcellular level imaging of mAb distribution, microcellular level studies by Paik et al. [8, 9] showed the penetration and enhanced accumulation of mAbs in tumors following the modulation of the tumor microenvironment [9, 78]. Although conventional clinical nuclear medicine imaging techniques such as PET and SPECT have been widely used in molecular imaging, they have limited spatial resolution for revealing the intratumoral mAb micro-distribution. Therefore, imaging of fluorescent dye-conjugated mAb distribution would be useful to confirm the micro-distribution of mAbs within tumors.

Conclusion

The tumor microenvironment may play an important role in solid tumor RIT. When α-emitter-labeled mAbs were used, deeper penetration of α-emitter-labeled mAbs inside tumors was more important because of the short range of the α emitter. Moreover, combination therapy strategies aimed at improving mAb tumor penetration and accumulation are crucial and would be beneficial for maximizing their therapeutic efficacy against solid tumors.

Acknowledgments

This work was supported by the Korea Science and Engineering Foundation (KOSEF) (No. 2015001667 [P.I., Joo Hyun Kang]), No. 1711026888 [P.I., Kook-Hyun Yu]), and Heath technology R&D (No HO15C0003 [P.I., JIN SU KIM]).

Compliance with Ethical Standards

Conflict of Interest

Jin Su Kim have no conflict of interests.

Ethical Statement

This article does not contain any studies with human participants or animals performed by any of the authors. The study was approved by an institutional review board or equivalent and has been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments. All subjects in the study gave written informed consent or the institutional review board waived the need to obtain informed consent.

Disclosure

This manuscript has not been published before or is not under consideration for publication anywhere else.

References

  • 1.Erdi AK, Erdi YE, Yorke ED, Wessels BW. Treatment planning for radio-immunotherapy. Phys Med Biol. 1996;41:2009–26. doi: 10.1088/0031-9155/41/10/011. [DOI] [PubMed] [Google Scholar]
  • 2.Allen TM. Ligand-targeted therapeutics in anticancer therapy. Nat Rev Cancer. 2002;2:750–63. doi: 10.1038/nrc903. [DOI] [PubMed] [Google Scholar]
  • 3.Larson SM, Carrasquillo JA, Cheung NK, Press OW. Radioimmunotherapy of human tumours. Nat Rev Cancer. 2015;15:347–60. doi: 10.1038/nrc3925. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Gopal AK, Gooley TA, Rajendran JG, Pagel JM, Fisher DR, Maloney DG, et al. Myeloablative 131I-tositumomab with escalating doses of fludarabine and autologous hematopoietic transplantation for adults age ≥60 years with B cell lymphoma. Biol Blood Marrow Transplant. 2014;206:770–5. doi: 10.1016/j.bbmt.2014.02.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Becker W, Behr T. High dose radioimmunotherapy in relapsed B-cell lymphoma with 131I-rituximab. Ann Hematol. 2001;80(Suppl 3):B130–1. doi: 10.1007/pl00022777. [DOI] [PubMed] [Google Scholar]
  • 6.Kang GW, Kang HJ, Shin DY, Gu HR, Choi HS, Lim SM. Radioimmunotherapy with 131I-rituximab in a patient with diffuse large B-cell lymphoma relapsed after treatment with 90Y-Ibritumomab tiuxetan. Nucl Med Mol Imaging. 2013;47:281–4. doi: 10.1007/s13139-013-0229-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Zalutsky MR, Pozzi OR. Radioimmunotherapy with alpha-particle emitting radionuclides. Q J Nucl Med Mol Imaging. 2004;48:289–96. [PubMed] [Google Scholar]
  • 8.Jang BS, Lee SM, Kim HS, Shin IS, Razjouyan F, Wang S, et al. Combined-modality radioimmunotherapy: synergistic effect of paclitaxel and additive effect of bevacizumab. Nucl Med Biol. 2012;39:472–83. doi: 10.1016/j.nucmedbio.2011.10.020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Wang S, Shin IS, Hancock H, Jang BS, Kim HS, Lee SM, et al. Pulsed high intensity focused ultrasound increases penetration and therapeutic efficacy of monoclonal antibodies in murine xenograft tumors. J Control Release. 2012;20(162):218–24. doi: 10.1016/j.jconrel.2012.06.025. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Boerman OC, Oyen WJ. Immuno PET of cancer: a revival of antibody imaging. J Nucl Med. 2011;52:1171–2. doi: 10.2967/jnumed.111.089771. [DOI] [PubMed] [Google Scholar]
  • 11.van Dongen GA, Visser GW, Lub-de Hooge MN, de Vries EG, Perk LR. Immuno PET: a navigator in monoclonal antibody development and applications. Oncologist. 2007;12:1379–89. doi: 10.1634/theoncologist.12-12-1379. [DOI] [PubMed] [Google Scholar]
  • 12.Deri MA, Zeglis BM, Francesconi LC, Lewis JS. PET imaging with 89Zr: from radiochemistry to the clinic. Nucl Med Biol. 2013;40:3–14. doi: 10.1016/j.nucmedbio.2012.08.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Tamura K, Kurihara H, Yonemori K, Tsuda H, Suzuki J, Kono Y, et al. 64Cu DOTA-trastuzumab PET imaging in patients with HER2-positive breast cancer. J Nucl Med. 2013;54:1869–75. doi: 10.2967/jnumed.112.118612. [DOI] [PubMed] [Google Scholar]
  • 14.Mortimer JE, Bading JR, Colcher DM, Conti PS, Frankel PH, Carroll MI, et al. Functional imaging of human epidermal growth factor receptor 2-positive metastatic breast cancer using 64Cu DOTA-trastuzumab PET. J Nucl Med. 2014;55:23–9. doi: 10.2967/jnumed.113.122630. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Braghirolli AM, Waissmann W, da Silva JB, dos Santos GR. Production of 124I and its applications in nuclear medicine. Appl Radiat Isot. 2014;90:138–48. doi: 10.1016/j.apradiso.2014.03.026. [DOI] [PubMed] [Google Scholar]
  • 16.Preylowski V, Schlogl S, Schoenahl F, Jorg G, Samnick S, Buck AK, et al. Is the image quality of 124I PET impaired by an automatic correction of prompt gammas? PLoS One. 2013;27(8):e71729. doi: 10.1371/journal.pone.0071729. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Lee YS, Kim JS, Kim H-J, Woo S-K, Kim JG, Park JA, et al. Imaging Characteristics of 124I Between 3D and 2D on Siemens ECAT HR PET Scanner. IEEE Trans Nucl Sci. 2013;60:797–801. doi: 10.1109/TNS.2013.2240012. [DOI] [Google Scholar]
  • 18.Kim JS, Yu AR. Determination of single gamma photon fraction of 124I PET. J Instrum. 2015;10(P03006):1–8. [Google Scholar]
  • 19.Yu AR, Kim JS. Effect of filters and reconstruction algorithms on 124I PET in Siemens Inveon PET scanner. J Instrum. 2015;10(P10026):1–12. [Google Scholar]
  • 20.Yu AR, Kim JS, Kang JH, Lim SM. Comparison of reconstruction methods and quantitative accuracy in Siemens Inveon PET scanner. J Instrum. 2015;10(P04001):1–16. [Google Scholar]
  • 21.Vosjan MJ, Perk LR, Visser GW, Budde M, Jurek P, Kiefer GE, et al. Conjugation and radiolabeling of monoclonal antibodies with 89Zr for PET imaging using the bifunctional chelate p-isothiocyanatobenzyl-desferrioxamine. Nat Protoc. 2010;5:739–43. doi: 10.1038/nprot.2010.13. [DOI] [PubMed] [Google Scholar]
  • 22.Borjesson PK, Jauw YW, Boellaard R, de Bree R, Comans EF, Roos JC, et al. Performance of immuno PET with 89Zr chimeric mAb U36 in the detection of lymph node metastases in head and neck cancer patients. Clin Cancer Res. 2006;12:2133–40. doi: 10.1158/1078-0432.CCR-05-2137. [DOI] [PubMed] [Google Scholar]
  • 23.Sugyo A, Tsuji AB, Sudo H, Nagatsu K, Koizumi M, Ukai Y, et al. Evaluation of 89Zr labeled human anti-CD147 mAb as a PET probe in a mouse model of pancreatic cancer. PLoS One. 2013;8:e61230. doi: 10.1371/journal.pone.0061230. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Lee YS, Kim JS, Kim JY, Kim BI, Lim SM, Kim HJ. Spatial resolution and image qualities of 89Zr on Siemens Biograph TruePoint PET/CT. Cancer Biother Radiopharm. 2015;30:27–32. doi: 10.1089/cbr.2014.1709. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Disselhorst JA, Brom M, Laverman P, Slump CH, Boerman OC, Oyen WJ, et al. Image-quality assessment for several positron emitters using the NEMA NU 4-2008 standards in the Siemens Inveon small-animal PET scanner. J Nucl Med. 2010;51:610–7. doi: 10.2967/jnumed.109.068858. [DOI] [PubMed] [Google Scholar]
  • 26.Quackenbush RC, Horner TJ, Williams VC, Giampietro P, Lin TS. Patients with relapsed follicular lymphoma treated with rituximab versus tositumomab and 131I tositumomab. Leuk Lymphoma. 2015;56:779–81. doi: 10.3109/10428194.2014.927461. [DOI] [PubMed] [Google Scholar]
  • 27.Srinivasan A, Mukherji SK. Tositumomab and 131I tositumomab (Bexaar) AJNR Am J Neuroradiol. 2011;32:637–8. doi: 10.3174/ajnr.A2593. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Sjogreen-Gleisner K, Dewaraja YK, Chiesa C, Tennvall J, Linden O, Strand SE, et al. Dosimetry in patients with B-cell lymphoma treated with 90Y ibritumomab tiuxetan or 131I tositumomab. Q J Nucl Med Mol Imaging. 2011;55:126–54. [PubMed] [Google Scholar]
  • 29.Hohloch K, Lankeit HK, Zinzani PL, Scholz CW, Lorsbach M, Windemuth-Kieselbach C, et al. Radioimmunotherapy for first-line and relapse treatment of aggressive B-cell non-Hodgkin lymphoma: an analysis of 215 patients registered in the international RIT-Network. Eur J Nucl Med Mol Imaging. 2014;41:1585–92. doi: 10.1007/s00259-014-2758-y. [DOI] [PubMed] [Google Scholar]
  • 30.Andrade Campos MM, Montes Limon AE, Grasa JM, Lievano P, Baringo T, Giraldo P. RIT with 90Y-ibritumomab tiuxetan in follicular non-Hodgkin lymphoma: evaluation of recent outcomes in a single institution. J Oncol. 2012;2012:412742. doi: 10.1155/2012/412742. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Prasad V. The withdrawal of drugs for commercial reasons: the incomplete story of tositumomab. JAMA Intern Med. 2014;174:1887–8. doi: 10.1001/jamainternmed.2014.5756. [DOI] [PubMed] [Google Scholar]
  • 32.Frost SH, Frayo SL, Miller BW, Orozco JJ, Booth GC, Hylarides MD, et al. Comparative efficacy of 177Lu and 90Y for anti-CD20 pretargeted radioimmunotherapy in murine lymphoma xenograft models. PLoS One. 2015;18(10):e0120561. doi: 10.1371/journal.pone.0120561. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Attarwala AA, Molina-Duran F, Busing KA, Schonberg SO, Bailey DL, Willowson K, et al. Quantitative and qualitative assessment of 90Y PET/CT imaging. PLoS One. 2014;4(9):e110401. doi: 10.1371/journal.pone.0110401. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Lhommel R, Goffette P, Van den Eynde M, Jamar F, Pauwels S, Bilbao JI, et al. 90Y TOF PET scan demonstrates high-resolution biodistribution after liver SIRT. Eur J Nucl Med Mol Imaging. 2009;36:1696. doi: 10.1007/s00259-009-1210-1. [DOI] [PubMed] [Google Scholar]
  • 35.Rong X, Du Y, Frey EC. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to 90Y bremsstrahlung SPECT imaging. Phys Med Biol. 2012;21(57):3711–25. doi: 10.1088/0031-9155/57/12/3711. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.de Jong M, Breeman WA, Valkema R, Bernard BF, Krenning EP. Combination radionuclide therapy using 177Lu and 90Y labeled somatostatin analogs. J Nucl Med. 2005;46(Suppl 1):13S–7. [PubMed] [Google Scholar]
  • 37.Siegel JA, Stabin MG. Absorbed fractions for electrons and beta particles in spheres of various sizes. J Nucl Med. 1994;35:152–6. [PubMed] [Google Scholar]
  • 38.Lu Y, Ndjock N, Mbong G, Liu P, Chan C, Cai Z, et al. Synthesis of polyglutamide-based metal-chelating polymers and their site-specific conjugation to trastuzumab for auger electron radioimmunotherapy. Biomacromolecules. 2014;9(15):2027–37. doi: 10.1021/bm500174p. [DOI] [PubMed] [Google Scholar]
  • 39.Li HK, Morokoshi Y, Daino K, Furukawa T, Kamada T, Saga T, et al. Transcriptomic signatures of auger electron radioimmunotherapy using nuclear targeting 111In-trastuzumab for potential combination therapies. Cancer Biother Radiopharm. 2015;30:349–58. doi: 10.1089/cbr.2015.1882. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Baranowska-Kortylewicz J. Intraperitoneal radioimmunotherapy: Auger electron emitters for solid tumors. Immunotherapy. 2011;3:491–4. doi: 10.2217/imt.11.11. [DOI] [PubMed] [Google Scholar]
  • 41.Pfost B, Seidl C, Autenrieth M, Saur D, Bruchertseifer F, Morgenstern A, et al. Intravesical alpha-radioimmunotherapy with 213Bi anti-EGFR-mAb defeats human bladder carcinoma in xenografted nude mice. J Nucl Med. 2009;50:1700–8. doi: 10.2967/jnumed.109.065961. [DOI] [PubMed] [Google Scholar]
  • 42.Back T, Haraldsson B, Hultborn R, Jensen H, Johansson ME, Lindegren S, et al. Glomerular filtration rate after alpha-radioimmunotherapy with 211At MX35-F(ab’)2: a long-term study of renal function in nude mice. Cancer Biother Radiopharm. 2009;24:649–58. doi: 10.1089/cbr.2009.0628. [DOI] [PubMed] [Google Scholar]
  • 43.Lucignani G. Alpha-particle radioimmunotherapy with 211At and 213Bi. Eur J Nucl Med Mol Imaging. 2008;35:1729–33. doi: 10.1007/s00259-008-0856-4. [DOI] [PubMed] [Google Scholar]
  • 44.Zhang M, Yao Z, Zhang Z, Garmestani K, Talanov VS, Plascjak PS, et al. The anti-CD25 monoclonal antibody 7G7/B6, armed with the alpha-emitter 211At, provides effective radioimmunotherapy for a murine model of leukemia. Cancer Res. 2006;66:8227–32. doi: 10.1158/0008-5472.CAN-06-1189. [DOI] [PubMed] [Google Scholar]
  • 45.Song H, Hobbs RF, Vajravelu R, Huso DL, Esaias C, Apostolidis C, et al. Radioimmunotherapy of breast cancer metastases with alpha-particle emitter 225Ac: comparing efficacy with 213Bi and 90Y. Cancer Res. 2009;69:8941–8. doi: 10.1158/0008-5472.CAN-09-1828. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Kiess AP, Minn I, Chen Y, Hobbs R, Sgouros G, Mease RC, et al. Auger radiopharmaceutical therapy targeting prostate-specific membrane antigen. J Nucl Med. 2015;56:1401–7. doi: 10.2967/jnumed.115.155929. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Gardette M, Viallard C, Paillas S, Guerquin-Kern JL, Papon J, Moins N, et al. Evaluation of two 125I radiolabeled acridine derivatives for Auger-electron radionuclide therapy of melanoma. Investig New Drugs. 2014;32:587–97. doi: 10.1007/s10637-014-0086-5. [DOI] [PubMed] [Google Scholar]
  • 48.Falzone N, Fernandez-Varea JM, Flux G, Vallis KA. Monte Carlo evaluation of auger electron-emitting theranostic radionuclides. J Nucl Med. 2015;56:1441–6. doi: 10.2967/jnumed.114.153502. [DOI] [PubMed] [Google Scholar]
  • 49.Kelkar SS, Reineke TM. Theranostics: combining imaging and therapy. Bioconjug Chem. 2011;19(22):1879–903. doi: 10.1021/bc200151q. [DOI] [PubMed] [Google Scholar]
  • 50.Charlton DE. The range of high LET effects from 125I decays. Radiat Res. 1986;107:163–71. doi: 10.2307/3576804. [DOI] [PubMed] [Google Scholar]
  • 51.Dewaraja YK, Frey EC, Sgouros G, Brill AB, Roberson P, Zanzonico PB, et al. MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy. J Nucl Med. 2012;53:1310–25. doi: 10.2967/jnumed.111.100123. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.Wahl RL. The clinical importance of dosimetry in radioimmunotherapy with tositumomab and 131I tositumomab. Semin Oncol. 2003;30:31–8. doi: 10.1053/sonc.2003.23799. [DOI] [PubMed] [Google Scholar]
  • 53.Dewaraja YK, Wilderman SJ, Ljungberg M, Koral KF, Zasadny K, Kaminiski MS. Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation. J Nucl Med. 2005;46:840–9. [PMC free article] [PubMed] [Google Scholar]
  • 54.Lee YS, Kim JS, Cho KD, Kang JH, Lim SM. Tumor dosimetry for 131I trastuzumab therapy in a Her2+ NCI N87 xenograft mouse model using the Siemens SYMBIA E gamma camera with a pinhole collimator. J Instrum. 2015;10(P07001):1–10. [Google Scholar]
  • 55.Meredith R, Torgue J, Shen S, Fisher DR, Banaga E, Bunch P, et al. Dose escalation and dosimetry of first-in-human alpha radioimmunotherapy with 212Pb TCMC-trastuzumab. J Nucl Med. 2014;55:1636–42. doi: 10.2967/jnumed.114.143842. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Miller BW, Frost SH, Frayo SL, Kenoyer AL, Santos E, Jones JC, et al. Quantitative single-particle digital autoradiography with alpha-particle emitters for targeted radionuclide therapy using the iQID camera. Med Phys. 2015;42:4094–105. doi: 10.1118/1.4921997. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.Miller BW, Gregory SJ, Fuller ES, Barrett HH, Barber HB, Furenlid LR. The iQID camera: an ionizing-radiation quantum imaging detector. Nucl Instrum Methods Phys Res Sect A. 2014;11(767):146–52. doi: 10.1016/j.nima.2014.05.070. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Frost SH, Miller BW, Back TA, Santos EB, Hamlin DK, Knoblaugh SE, et al. Alpha imaging confirmed efficient targeting of CD45-positive cells after 211At radioimmunotherapy for hematopoietic cell transplantation. J Nucl Med. 2015;56:1766–73. doi: 10.2967/jnumed.115.162388. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Thurber GM, Schmidt MM, Wittrup KD. Factors determining antibody distribution in tumors. Trends Pharmacol Sci. 2008;29:57–61. doi: 10.1016/j.tips.2007.11.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60.Thurber GM, Schmidt MM, Wittrup KD. Antibody tumor penetration: transport opposed by systemic and antigen-mediated clearance. Adv Drug Deliv Rev. 2008;60:1421–34. doi: 10.1016/j.addr.2008.04.012. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Thurber GM, Zajic SC, Wittrup KD. Theoretic criteria for antibody penetration into solid tumors and micrometastases. J Nucl Med. 2007;48:995–9. doi: 10.2967/jnumed.106.037069. [DOI] [PubMed] [Google Scholar]
  • 62.Thurber GM, Weissleder R. Quantitating antibody uptake in vivo: conditional dependence on antigen expression levels. Mol Imaging Biol. 2011;13:623–32. doi: 10.1007/s11307-010-0397-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63.Thurber GM, Dane Wittrup K. A mechanistic compartmental model for total antibody uptake in tumors. J Theor Biol. 2012;314:57–68. doi: 10.1016/j.jtbi.2012.08.034. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 64.Thurber GM, Weissleder R. A systems approach for tumor pharmacokinetics. PLoS One. 2011;6:e24696. doi: 10.1371/journal.pone.0024696. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65.Tredan O, Galmarini CM, Patel K, Tannock IF. Drug resistance and the solid tumor microenvironment. J Natl Cancer Inst. 2007;99:1441–54. doi: 10.1093/jnci/djm135. [DOI] [PubMed] [Google Scholar]
  • 66.Jain RK, Stylianopoulos T. Delivering nanomedicine to solid tumors. Nat Rev Clin Oncol. 2010;7:653–64. doi: 10.1038/nrclinonc.2010.139. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 67.Heldin CH, Rubin K, Pietras K, Ostman A. High interstitial fluid pressure—an obstacle in cancer therapy. Nat Rev Cancer. 2004;4:806–13. doi: 10.1038/nrc1456. [DOI] [PubMed] [Google Scholar]
  • 68.Heine M, Freund B, Nielsen P, Jung C, Reimer R, Hohenberg H, et al. High interstitial fluid pressure is associated with low tumour penetration of diagnostic monoclonal antibodies applied for molecular imaging purposes. PLoS One. 2012;7:e36258. doi: 10.1371/journal.pone.0036258. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69.Choi IK, Strauss R, Richter M, Yun CO, Lieber A. Strategies to increase drug penetration in solid tumors. Front Oncol. 2013;26(3):193. doi: 10.3389/fonc.2013.00193. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 70.Beyer I, Li Z, Persson J, Liu Y, van Rensburg R, Yumul R, et al. Controlled extracellular matrix degradation in breast cancer tumors improves therapy by trastuzumab. Mol Ther. 2011;19:479–89. doi: 10.1038/mt.2010.256. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 71.Du Y, Honeychurch J, Glennie M, Johnson P, Illidge T. Microscopic intratumoral dosimetry of radiolabeled antibodies is a critical determinant of successful radioimmunotherapy in B-cell lymphoma. Cancer Res. 2007;67:1335–43. doi: 10.1158/0008-5472.CAN-06-2495. [DOI] [PubMed] [Google Scholar]
  • 72.Jhanwar YS, Divgi C. Current status of therapy of solid tumors. J Nucl Med. 2005;46(Suppl 1):141S–50. [PubMed] [Google Scholar]
  • 73.Ocean AJ, Pennington KL, Guarino MJ, Sheikh A, Bekaii-Saab T, Serafini AN, et al. Fractionated radioimmunotherapy with 90Y clivatuzumab tetraxetan and low-dose gemcitabine is active in advanced pancreatic cancer: a phase 1 trial. Cancer. 2012;118:5497–506. doi: 10.1002/cncr.27592. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 74.Goldenberg DM, Sharkey RM, Paganelli G, Barbet J, Chatal JF. Antibody pretargeting advances cancer radioimmunodetection and radioimmunotherapy. J Clin Oncol. 2006;24:823–34. doi: 10.1200/JCO.2005.03.8471. [DOI] [PubMed] [Google Scholar]
  • 75.Weldon JE, Xiang L, Zhang J, Beers R, Walker DA, Onda M, et al. A recombinant immunotoxin against the tumor-associated antigen mesothelin reengineered for high activity, low off-target toxicity, and reduced antigenicity. Mol Cancer Ther. 2013;12:48–57. doi: 10.1158/1535-7163.MCT-12-0336. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 76.Na Y, Choi JW, Kasala D, Hong J, Oh E, Li Y, et al. Potent antitumor effect of neurotensin receptor-targeted oncolytic adenovirus co-expressing decorin and Wnt antagonist in an orthotopic pancreatic tumor model. J Control Release. 2015;220(Pt B):766–82. doi: 10.1016/j.jconrel.2015.10.015. [DOI] [PubMed] [Google Scholar]
  • 77.Vogel KG, Paulsson M, Heinegard D. Specific inhibition of type I and type II collagen fibrillogenesis by the small proteoglycan of tendon. Biochem J. 1984;223:587–97. doi: 10.1042/bj2230587. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 78.Khaibullina A, Jang BS, Sun H, Le N, Yu S, Frenkel V, et al. Pulsed high-intensity focused ultrasound enhances uptake of radiolabeled monoclonal antibody to human epidermoid tumor in nude mice. J Nucl Med. 2008;49:295–302. doi: 10.2967/jnumed.107.046888. [DOI] [PubMed] [Google Scholar]

Articles from Nuclear Medicine and Molecular Imaging are provided here courtesy of Springer

RESOURCES