Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1967 Jul;29(4):602–607. doi: 10.1136/hrt.29.4.602

Determination of pulmonary blood volume by injection into pulmonary artery and sampling in left atrium.

F K Nakhjavan, V Maranhao, R Son, H Goldberg
PMCID: PMC487839  PMID: 5339519

Full text

PDF
602

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. BASSINGTHWAIGHTE J. B., EDWARDS A. W., WOOD E. H. Areas of dye-dilution curves sampled simultaneously from central and peripheral sites. J Appl Physiol. 1962 Jan;17:91–98. doi: 10.1152/jappl.1962.17.1.91. [DOI] [PubMed] [Google Scholar]
  2. BROCKENBROUGH E. C., BRAUNWALD E., ROSS J., Jr Transseptal left heart catheterization. A review of 450 studies and description of an improved technic. Circulation. 1962 Jan;25:15–21. doi: 10.1161/01.cir.25.1.15. [DOI] [PubMed] [Google Scholar]
  3. DOCK D. S., KRAUS W. L., McGUIRE L. B., HYLAND J. W., HAYNES F. W., DEXTER L. The pulmonary blood volume in man. J Clin Invest. 1961 Feb;40:317–328. doi: 10.1172/JCI104259. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. KOPELMAN H., LEE G. DE J. The intrathoracic blood volume in mitral stenosis and left ventricular failure. Clin Sci. 1951 Aug;10(3):383–403. [PubMed] [Google Scholar]
  5. LEVINSON G. E., FRANK M. J., HELLEMS H. K. THE PULMONARY VASCULAR VOLUME IN MAN. MEASUREMENT FROM ATRIAL DILUTION CURVES. Am Heart J. 1964 Jun;67:734–741. doi: 10.1016/0002-8703(64)90174-7. [DOI] [PubMed] [Google Scholar]
  6. LILIENFIELD L. S., KOVACH R. D. Simplified method for calculating flow, mean circulation time and downslope from indicator-dilution curves. Proc Soc Exp Biol Med. 1956 Apr;91(4):595–598. doi: 10.3181/00379727-91-22341. [DOI] [PubMed] [Google Scholar]
  7. MILNOR W. R., JOSE A. D. Distortion of indicator-dilution curves by sampling systems. J Appl Physiol. 1960 Jan;15:177–180. doi: 10.1152/jappl.1960.15.1.177. [DOI] [PubMed] [Google Scholar]
  8. OPDYKE D. F., SNIFFEN R. E. Estimation of cardiac output by rapidly repeated dye-dilution technic. Proc Soc Exp Biol Med. 1959 Oct-Dec;102:725–728. doi: 10.3181/00379727-102-25377. [DOI] [PubMed] [Google Scholar]
  9. SEKELJ P., BATES D. V., JOHNSON A. L., JEGIER W. Estimation of cardiac output in man by dye dilution method using an automatic computing oximeter. Am Heart J. 1958 Jun;55(6):810–823. doi: 10.1016/0002-8703(58)90098-x. [DOI] [PubMed] [Google Scholar]
  10. Samet P., Bernstein W. H., Lopez A., Levine S. Methodology of true pulmonary blood volume determination. Circulation. 1966 Jun;33(6):847–853. doi: 10.1161/01.cir.33.6.847. [DOI] [PubMed] [Google Scholar]
  11. Taylor S. H., Shillingford J. P. CLINICAL APPLICATIONS OF COOMASSIE BLUE. Br Heart J. 1959 Oct;21(4):497–504. doi: 10.1136/hrt.21.4.497. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES