Abstract
Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivity and specificity of D-dimer for AAD. Non-English language articles and conference abstract were allowed. Intramural hematoma and penetrating aortic ulcer were regarded as AAD. Based on 22 eligible articles consisting of 1140 AAD subjects and 3860 non-AAD subjects, the diagnostic odds ratio was 28.5 (95% CI 17.6–46.3, I2 = 17.4%) and the area under curve was 0.946 (95% CI 0.903–0.994). Based on 833 AAD subjects and 1994 non-AAD subjects constituting 12 studies that used the cutoff value of 500 ng/ml, the sensitivity was 0.952 (95% CI 0.901–0.978), the specificity was 0.604 (95% CI 0.485–0.712), positive likelihood ratio was 2.4 (95% CI 1.8–3.3), and negative likelihood ratio was 0.079 (95% CI 0.036–0.172). Sensitivity analysis using data of three high-quality studies almost replicated these results. In conclusion, D-dimer has very good overall accuracy. D-dimer <500 ng/ml largely decreases the possibility of AAD. D-dimer >500 ng/ml moderately increases the possibility of AAD.
Acute aortic dissection (AAD) is one of the most dangerous emergency diseases1. Clinicians usually rank AAD as the top differential diagnosis for patients who present typical sudden onset severe chest or back pain. However, some AAD cases may present with very vague symptoms such as abdominal discomfort or syncope2. Although some imaging studies, namely enhanced computed tomography (CT), magnetic resonance angiography, transesophageal echocardiogram, and angiography, have high accuracy in diagnosing AAD, it is often difficult to perform these tests as an initial diagnostic test because of high-cost, radiation exposure from unnecessary tests, the limited resources available at a facility, and risks for anaphylaxis and acute kidney injury. Thus, we need a simple laboratory test to rule out AAD3,4.
D-dimer is a typical degradation product of cross-linked fibrin5, whose serum level is known to be a good diagnostic tool for deep venous thrombosis, pulmonary embolism, and AAD. For rule-out purposes, a cut off value should be set for high sensitivity. Based on research in pulmonary embolism, the cutoff value of 500 ng/ml is often chosen to rule out AAD5,6,7,8,9,10.
During the last 10 years, an increasing number of case-control and observational studies have reported the diagnostic accuracy of D-dimer for AAD11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32. In addition, a few systematic reviews and meta-analyses have calculated the pooled sensitivity and specificity using a univariate fixed- or random-model5,6,7,8,9,10,27. However, few original studies were included in these systematic reviews. In addition, the recent meta-analysis methodology for the diagnostic test accuracy strongly recommends the use of the hierarchical model instead of the separate pooling of sensitivity and specificity33,34,35,36. Thus, we conducted this systematic review and meta-analysis to assess the diagnostic accuracy of D-dimer for AAD based on the hierarchical model and a careful study search strategy9.
Methods
Study registration
The protocol was registered at the international prospective register of systematic reviews (PROSPERO) website on number CRD4201503009537. This study followed PRISMA statement and the Cochrane Handbook for Diagnostic Test Accuracy Reviews34,38.
Institutional review board ethical approval was not needed because of the reviewing nature of this study.
Inclusion criteria and study search
We included case-control studies, prospective and retrospective cohort studies that could provide sufficient data concerning both sensitivity and specificity of D-dimer for AAD. Imaging modality as reference test should be clearly indicated in each study. Single- and two-gate studies are customarily termed cohort and case-control studies. Non-English language reports and conference abstracts were allowed.
Study search
In the electronic search, we systematically searched Pubmed, EMBASE, the Cochrane Library advanced search, and Web of Science Core Collection. The search formulas are shown in the e-Appendix 1. References of previously published reviews and those of included original studies were checked through a hand search.
Two investigators independently screened the candidate articles by checking the title and abstract. After independent screening, articles that were still regarded as candidates by at least one investigator were then scrutinized independently through full-text reading. Final inclusion was decided after resolving discrepancies between the two investigators.
Outcome
We considered blood D-dimer level as an index test measured by any method3,4. A cutoff value for D-dimer was set at 500 ng/ml, in accordance with previous meta-analyses6,7,9,27.
To diagnose AAD, the following exams were considered preferable reference tests: angiography, enhanced CT, CT angiography, magnetic resonance imaging, and trans-esophageal echocardiography3,4. Diagnosis by autopsy was also allowed. Any type of AAD according to the DeBakey classification and the Stanford classification were regarded as AAD. Aortic aneurism rupture, aortic aneurism pending rupture, and chronic aortic dissection were not considered as AAD3. Along with classic AAD, we regarded intramural hematoma, and penetrating aortic ulcer as AAD because it is clinically very difficult to distinguish them from classic AAD3.
Data that were extracted by the two investigators were crosschecked. First, we made two by two contingency tables from the number of subjects with true positives/false negatives/false positives/true negatives described in each original study. Then, we assessed diagnostic odds ratio (DOR), area under hierarchical summary receiver operating characteristic (HSROC) curve (AUC) to discover the overall diagnostic accuracy. The summary estimates of the sensitivity, the specificity, the positive likelihood ratio (PLR), the negative likelihood ratio (NLR), the positive predictive value (PPV) and the negative predictive value (NPV) were also assessed33.
Quality assessment for bias and applicability
The two investigators independently evaluated each study by scoring seven domains of A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) evaluation sheet39. Any discrepancies were resolved through discussion. Use of plain CT or trans-thoracic echocardiography led to high applicability concern for reference test. In this review, a “high-quality report” was defined as an original study that had neither high risk of bias nor high applicability concerns in any of the QUADAS-2 domains and that used a cut off value of 500 ng/ml. We used a high-quality report subgroup for sensitivity analyses.
Data synthesis
We used both the HSROC model and bivariate model33,34,35,36. To determine the overall accuracy, we calculated the DOR using the DerSimonian-Laird random-effect model and the AUC using Holling’s proportional hazard models and using data from all studies with any D-dimer cutoff value40,41. A cutoff value of 500 ng/ml was used to estimate the summary estimates of the sensitivity, the specificity, PLR, NLR, PPV, and NPV. We obtained a paired forest plot, HSROC curve, and summary estimates of the sensitivity and the specificity using the bivariate model34. PLR and NLR were obtained using the summary estimate of the sensitivity and the specificity34. We estimated PPV and NPV across the pre-test probabilities in the range of 0–100%.
Software
We drew a paired forest plot using Reviewing Manager ver. 5.3 (Cochrane Collaboration, Oxford, UK). The following commands of the “mada” package of the free software R were used: “madauni” for DOR, “phm” for AUC, and “reitsma” for the HSROC curve and the summary estimates for the sensitivity and the specificity40,41.
Sensitivity analysis
We conducted two subgroup analyses: studies using the D-dimer cutoff value of 500 ng/ml and high-quality reports. The primary outcomes of this systematic review were from the main analysis and the results from the sensitivity analysis were used for judging the robustness of the main outcomes.
Results
Study search and study characteristics
Of 557 articles that met the preliminary criteria, 204, 211, and 120 were excluded through removal of duplication, title/abstract screening, and full-article scrutinizing, respectively (Fig. 1). We finally found 22 eligible articles11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32. Most studies were from Asian and European countries (Table 1). The 22 articles included 14 cohort studies, eight case-control studies, two conference abstracts, and 20 full-length articles. One article was written in German and the others were written in English. The participants included in the studies ranged from 11 to 1236 with a median of 80. The total number of subjects was 5000, which consisted of 1140 AAD cases and 3860 controls. Across 22 studies, the sensitivity ranged from 0.52 to 1 with a median of 0.97 (IQR: 0.93–1.00) and the specificity ranged from 0.25 to 0.98 with a median of 0.64 (IQR: 0.37–0.97) (Fig. 2).
Table 1. Characteristics of included studies.
Author (Year) | Country | Study design | Recruit setting | Reference test | Index test | Cutoff ng/ml | High quality |
---|---|---|---|---|---|---|---|
Akutsu11 | Japan | pCohort | s/o AAD, r/o AMI. CCU | e-CT | Roche, Cardiac d-dimer sysetem | 500 | No |
Eggebrecht12 | Netherlands | Case-control | Control: PE, AMI, non-cardiac chest pain | TEE, Angio, CT, MRI | Dade Behring, D-Dimer Plus | 500 | No |
Ersel13 | Turkey | rCohort | s/o AAD. ED | e-CT | Dade Behring, quantitative immunoturbidimetric assay | 246 | No |
Fan14 | China | pCohort | s/o AAD. Admitted | TTE, TEE, CT, MRI | Tina-quant | 500 | No |
Giachino15 | Italy | pCohort | s/o AAD. ED | e-CT | STA LIATEST D-DI | 500 | Yes |
Gorla16 | Germany | rCohort | Chest pain. Admitted | TTE, TEE, e-CT, MRI, Angio | Innovance D-dimer | 500 | No |
Hazui17 | Japan | Case-control | Control: AMI. Admitted to critical care center | e-CT | Roche, Latex agglutination | 900 | No |
Levcik18 | Czech | rCohort | Acute chest pain. Admitted | CT, TEE, Angio, Autopsy | INNOVANCE D-Dimer assay, Liatest D-DI, Coamatic D-Dimer, D-Dimer plus | 500 | No |
Li19 | China | rCohort, CA | Not specified | e-CT | Not specified | 500 | Yes |
Nazerian20 | Italy | rCohort | s/o AAD. ED | CT-angio | Hemosil D-dimer HS, STA LIATEST D-DI | 500 | Yes |
Ohlmann21 | France | Case-control | Control: s/o AAD but later r/o AAD, Admitted | TEE, CT, MRI | Sta-Liatest D-DI immunoturbidimetric assay | 400 | No |
Okazaki22 | Japan | Case-control | Admitted for cardioembilic stroke | e-CT, plain-CT | LIAS AUTO d-dimer | 8700 | No |
Peng23 | China | pCohort | Chest pain. ED | CT-Angio | ELISA | 2110 | No |
Reeps24 | Germany | Case-control | Control: Chronic progressive type B dissection | CT-Angio, PET/CT | Not specified | 500 | No |
Sakamoto25 | Japan | Case-control | Control: PE/AMI | e-CT | LIAS AUTO d-dimer neo | 5000 | No |
Sbarouni26 | Greece | Case-control | Control: chronic aortic aneurysm, normal subject, Admitted | TTE, TEE, CT | Vidas, D-dimer ELISA | 700 | No |
Shao27 | China | pCohort | Chest/back/abdominal pain. Admitted | TTE, TEE, CT, MRI | Tina-quant D-dimer | 500 | No |
Spinner28 | Germany# | Cohort | Acute chest pain r/o STEMI. ICU | TEE, CT, Angio | Roche, Latex agglutination | 300 | No |
Stanojlovic29 | Serbia | Cohort, CA | Not specified | TTE, TEE, CT | Automated chemical analysis | 500 | No |
Weber30 | Austria | Case-control | Control: ICU case with chest pain r/o AAD | TTE, TEE, CT, MRI, Angio | Tina-quant assay | 500 | No |
Xue31 | China | pCohort | Chest pain, s/o AAD. | TEE, CT, MRI | Sta-Liatest D-DI immunoturbidimetric assay | 400 | No |
Yoshimuta32 | Japan | Cohort | TIA or ischemic stroke w/o chest symptom. ED | e-CT | Sekisui, Latex agglutination | 6900 | No |
<Country> #: written in German language.
<Design> pCohort: prospective cohort. rCohort: retrospective cohort. CC: case-control. CA conference abstract.
<Recruit setting> AAD: acute aortic dissection. AMI: acute myocardial infarction. PE: pulmonary embolism. AAS: Acute aortic syndrome. STEMI: ST elevated myocardial infarction. TIA: transient ischemic attack. ED: emergency department. ICU: intensive care unit. s/o: suspected of. r/o: ruled out. AAD subjects for cases of case-control studies were default and not described.
<Reference test> CT: computed tomography. e-CT: enhanced CT. TTE: trans-thoracic echocardiography. TEE: trans-esophageal echocardiography. Angio: angiography. MRI: magnetic resonance imaging. PET: positron emission tomography.
<High quality> A study that had neither a high risk of bias nor a high concern regarding applicability and that used a cutoff value of 500 ng/ml was regarded as a high quality report.
Nineteen studies had at least one domain of high risk of bias or high applicability concern, the other three had none. These three studies were classified as high-quality reports (Table 1, e-Fig. 1). Frequent causes of the high risk of bias and the high applicability concern were case-control study design, inappropriate subject recruiting, arbitrary selection of D-dimer cutoff value, and potential use of plain CT and trans-thoracic echocardiography as reference test.
Overall diagnostic accuracy
Using data from all 22 studies consisting of 1140 AAD subjects and 3860 non-AAD subjects, DOR was 28.5 (95% confidence interval (95% CI) 17.6–46.3, I2 = 17.4%) and AUC was 0.946 (95% CI 0.903–0.994) (Table 2, Fig. 3A). According to a criterion of Jones et al., AUC in the range of 0.93–0.96 was categorized as “very good” from the categories “excellent,” “very good,” “good,” and “reasonable”42.
Table 2. Summary of diagnostic accuracy by D-dimer for acute aortic dissection.
All studies regardless of the cutoff value | Studies with the cutoff value of 500 ng/ml | High-quality reports | |
---|---|---|---|
Studies | 22 | 12 | 3 |
Acute aortic dissection | 1140 | 833 | 402 |
Controls | 3860 | 1994 | 1079 |
Diagnostic odds ratio | 28.5 (17.6–46.3) I2 = 17.4% | 30.7 (17.0–55.2) I2 = 7.7% | 30.4 (17.2–53.7) I2 = 0% |
AUC | 0.946 (0.903–0.994) | 0.950 (0.847–1.000) | 0.954 (0.909–1.000) |
Sensitivity | Not available | 0.952 (0.901–0.978) | 0.971 (0.919–0.990) |
Specificity | Not available | 0.604 (0.485–0.712) | 0.532 (0.297–0.753) |
Positive likelihood ratio | Not available | 2.4 (1.8–3.3) | 2.1 (1.4–3.9) |
Negative likelihood ratio | Not available | 0.079 (0.036–0.172) | 0.055 (0.018–0.177) |
Brackets indicate 95% confidence interval.
High-quality reports: A study that had neither a high risk of bias nor a high concern regarding applicability and that used a cutoff value of 500 ng/ml was regarded as a high-quality report.
AUC: area under hierarchical summary receiver operating characteristics curve.
Main outcomes concerning diagnostic accuracy are written in italics. The others are results from sensitivity analysis.
According to the first sensitivity analysis using data from 12 studies that used the cutoff value of 500 ng/ml, DOR was 30.7 (95% CI 17.0–55.2, I2 = 7.7%) and AUC was 0.950 (95% CI 0.847–1.000) (Table 2, Fig. 3B). For the second sensitivity analysis, we evaluated three high-quality reports, which revealed DOR of 30.4 (95% CI 17.2–53.7, I2 = 0%) and AUC was 0.954 (95% CI 0.909–1.000) (Table 2, Fig. 3C). These values suggested that overall diagnostic accuracy did not change through sensitivity analyses.
Sensitivity and specificity
Based on 833 AAD patients and 1994 non-AAD participants constituting 12 studies that used the cutoff value of 500 ng/ml, the sensitivity was 0.952 (95% CI 0.901–0.978) and the specificity was 0.604 (95% CI 0.485–0.712) (Table 2, Fig. 3B).
Sensitivity analysis based on the three high-quality reports comprising 1481 subjects suggested that sensitivity was 0.971 (95% CI 0.919–0.990) and specificity was 0.532 (95% CI 0.297–0.753) (Table 2, Fig. 3C, e-Fig. 2). These sensitivity and specificity figures in the sensitivity analysis did not greatly differ from those derived from the 12 studies above.
Positive and negative likelihoods ratios
We estimated PLR and NLR from data of 12 studies that used a cutoff value of 500 ng/ml. This yielded PLR of 2.4 (95% CI 1.8–3.3) and NLR of 0.079 (95% CI 0.036–0.172). According to Grimes et al., PLR in the range of 2–5 represents a small increase of probability when test is positive, and NLR <0.1 represents large decrease of probability when test is negative43.
Sensitivity analysis using data of three high-quality studies almost replicated PLR and NLR.
Positive and negative predictive values
We estimated PPV and NPV across pre-test probability ranging from 0% to 100% (Fig. 4).
Classification of AAD
Three studies presented numbers of patients with classic AAD, intraluminal hematoma, and penetrating aortic ulcer16,20,29. Classic AAD, intraluminal hematoma, and penetrating aortic ulcer constituted 83% (95% CI 73–92%), 13% (95% CI 9–16%), and 5% (95% CI 0–12%), respectively, of broad meaning of AAD (Fig. 5).
Discussion
To our knowledge, the current study is the first systematic review and meta-analysis evaluating the diagnostic test accuracy of D-dimer for AAD using solid methodology and a sufficient number of original studies and subjects (Table 3). This was achieved by a careful study search and the use of a hierarchical model, and sensitivity analyses. Even though many meta-analyses concerning the same topic have been reported, they have had some common flaws: using univariate analysis, evaluation of studies with high risk of bias and with high applicability concern not thoughtfully, using a range of cutoff values collectively to estimate the pooled sensitivity and the pooled specificity, and limited numbers of original studies and subjects. In the current analysis, we confirmed that D-dimer has good sensitivity and moderate specificity using solid methodology when the cutoff value is 500 ng/ml (Table 2). D-dimer appears suitable for AAD and acute aortic syndrome rule-out without diagnostic imaging in patients with sufficiently low pre-test probability (Fig. 4).
Table 3. Summary of systematic reviews and meta-analyses evaluating the diagnostic accuracy of D-dimer for acute aortic dissection.
Author (Year) | Studies | Subjects | Model | Cutoff (ng/ml) | Quality assessment | Sensitivity analysis | Diagnostic odds ratio | AUC | Sensitivity | Specificity |
---|---|---|---|---|---|---|---|---|---|---|
Sodeck10 | 16 | 437 | Random-effect | 100–900# | QUADAS | Done | 21.27 | 0.94 | 0.97 | 0.59 |
Marill7 | 11 | 541 | Fixed-effect | 500 | NA | NA | NA | NA | 0.94 | 0.95 |
Brown50 | 7 | 744 | Not specified | 500 | NA | NA | NA | NA | 0.97 | 0.56 |
Shimony6 | 7 | 744 | Random-effect | 500 | QUADAS | NA | NA | NA | 0.97 | 0.56 |
Shao29 | 9 | 1337 | Random-effect | 500 | NA | NA | NA | 0.88 | 0.89 | 0.68 |
Cui8 | 5 | 743 | Random-effect | 170–5000# | NOQAS | Done | NA | 0.92 | 0.945 | 0.691 |
Asha9 | 4 | 1557 | Random-effect | 400–500# | QUADAS/STARD | NA | NA | NA | 0.980 | 0.419 |
Watanabe | 22 | 5000 | Hierarchical | 246–8700# | QUADAS-2 | Done | 28.5 | 0.946 | NA | NA |
Watanabe | 12 | 2827 | Hierarchical | 500 | QUADAS-2 | Done | 30.7 | 0.950 | 0.952 | 0.604 |
#using a range of cutoff values collectively.
QUADAS: the Quality Assessment of Diagnostic Accuracy Studies.
QUADAS-2: the Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies.
STARD: the Standards for Reporting of Diagnostic Accuracy.
NOQAS: the Newcastle-Ottawa Quality Assessment Scale.
NA: not assessed.
AUC: area under (hierarchical) summary receiver operating characteristics curve.
A case-control study by Weber et al. in 2003 was a milestone in this area30. Until 2003, blood tests had played a very minor role in diagnosis of AAD. Weber et al. measured D-dimer levels of 10 AAD suspected cases, 14 definite AAD cases, and 35 patients who had chest pain that was caused by other causes than AAD. They used a cutoff value of 500 ng/ml because the cutoff value to exclude venous thrombosis in their hospital was 500 ng/ml. With this cutoff value, the sensitivity was 100% and specificity was 68.6% for AAD. Since then, numerous observational studies had re-confirmed the high sensitivity and the moderate specificity of D-dimer for AAD with the same cutoff value. Elevation of the D-dimer level reflects the fibrinolytic activity in responses to thrombosis of the false lumen and activation of the extrinsic pathway of the coagulation cascade with an injured aorta12,30. Among AAD cases, a highly elevated level of D-dimer also reflects the anatomical extent of the dissection30.
Nazerian et al. reported a retrospective cohort study evaluating the largest number of subjects with suspected AAD to assess the diagnostic accuracy of D-dimer for AAD20. They classified suspected AAD cases into three categories based on AAD risk score, score = 0, = 1, and ≥2. As pretest probability that was accessed by the risk score increased, PPV increased and NPV decreased. However, sensitivity and specificity were not greatly differed in all risk score groups. Across all score groups, the sensitivity was 0.983 and the specificity was 0.359. They reported higher sensitivity and lower specificity than our summary estimates of the sensitivity of 0.952 and the specificity of 0.604 (Table 2). This is a typical trade-off between sensitivity and specificity. Nazarian et al. commented that older age and high rate of comorbidities in the observed population contributed to the high D-dimer level, the high sensitivity, and the low specificity20. Recently, an age-adjusted D-dimer cutoff value, which is defined as age ×10 in patients 50 years or older, has been used to rule out pulmonary embolism and deep venous thrombosis, which increases specificity without modifying sensitivity44,45. Application of the age-adjusted D-dimer cutoff for ruling out AAD probably increases the specificity, however, this requires further research.
Classic AAD, intramural hematoma, and penetrating atherosclerotic ulcer constitute the acute aortic syndrome. It is very difficult to distinguish the three diseases from each other, because they have mutually overlapping pathology and symptoms3. Aortic intramural hematoma refers to an aortic wall hematoma not accompanied by an intimal flap. This accounts for approximately 10% of acute aortic syndrome cases (Fig. 5)3,4. Aortic intramural hematoma is caused by the rupture of the vasa vasorum at the aortic wall or microtears in the intima, while the intimal rupture precedes the intramural cleavage for AAD. Intramural hematoma formation frequently occurs in the descending thoracic aorta. It can perforate through the intima and lead to AAD3,4. Atherosclerotic aortic ulcers are also commonly observed in the descending aorta. When progressed deep into the aortic wall, the ulcer can result in intramural hematoma, penetrating ulcer, and aneurysm formation. Older age, hypertension, dyslipidemia, and severe aortic atherosclerosis are common risk factors for AAD, intramural hematoma, and penetrating atherosclerotic ulcer3,4. Given the pathology, it is reasonable for the D-dimer level to be elevated also for intramural hematoma and penetrating atherosclerotic ulcer. Actually, Garla and Stanojlovic reported that D-dimer levels were usually elevated for intramural hematoma and penetrating atherosclerotic ulcer16,29, which slightly lowered the specificity of D-dimer for AAD. Pulmonary embolism, deep venous thrombosis, systemic inflammation, and post-operation situation are also well known cause of D-dimer elevation, which leads to false positive in non-AAD population.
Even though the sensitivity and NPV of D-dimer are very good, D-dimer may overlook AAD46. False negative D-dimer are often observed for a young population, short dissection length, and thrombosed false lumen11,17.
A limitation of the current analysis is that most of the included studies had a high risk of bias or high applicability concerns. While some non-high-quality studies, namely studies by Sakamoto et al. and Shao et al. presented extraordinary low sensitivity (Fig. 2), three high-quality studies reported results compatible with previous reviews (e-Fig. 2)9,10. Anyway, the results of sensitivity analyses focusing on the high-quality report were consistent with those from all studies. Next, we evaluated numerous D-dimer assay methods collectively. Nonetheless, we observed only very weak heterogeneity during DOR evaluation (Table 2). The age dependency of DD is another limitation. We hope future researches will deal with the diagnostic test accuracy using age-adjusted DD cutoff values to predict AAD.
In conclusion, we performed this systematic review and meta-analysis of 22 studies with 5000 subjects to evaluate of the diagnostic test accuracy of D-dimer for AAD using a hierarchical model. DOR of 30.7 and AUC of 0.950 indicated that D-dimer has very good overall accuracy. Sensitivity of 0.952 and NLR of 0.079 meant that D-dimer <500 ng/ml largely decreases the possibility of AAD. Specificity of 0.604 and PPV of 2.4 meant that D-dimer >500 ng/ml moderately increases the possibility of AAD. Sensitivity analyses confirmed the robustness of our results.
Additional Information
How to cite this article: Watanabe, H. et al. Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects. Sci. Rep. 6, 26893; doi: 10.1038/srep26893 (2016).
Supplementary Material
Footnotes
Author Contributions H.W. contributed for study search, quality check, data extraction and drafting. H.N. work for study search, quality check, data extraction and analysis as a principal investigator. Y.S. provided study conception this study. S.M. worked for interpretation of the data as a cardiologist. E.O. contributed as a meta-analysis specialist. T.K. managed the study. All authors reviewed and finally approved the manuscript.
References
- Golledge J. & Eagle K. A. Acute aortic dissection. Lancet 372, 55–66 (2008). [DOI] [PubMed] [Google Scholar]
- Spiliopoulou C., Papadodima S., Kotakidis N. & Koutselinis A. Clinical diagnoses and autopsy findings: a retrospective analysis of 252 cases in Greece. Arch Pathol Lab Med 129, 210–214 (2005). [DOI] [PubMed] [Google Scholar]
- Hiratzka L. F. et al. 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with Thoracic Aortic Disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. Circulation 121, e266–369 (2010). [DOI] [PubMed] [Google Scholar]
- Khan I. A. & Nair C. K. Clinical, diagnostic, and management perspectives of aortic dissection. Chest 122, 311–328 (2002). [DOI] [PubMed] [Google Scholar]
- Perrier A. et al. D-dimer testing for suspected pulmonary embolism in outpatients. Am J Respir Crit Care Med 156, 492–496 (1997). [DOI] [PubMed] [Google Scholar]
- Shimony A., Filion K. B., Mottillo S., Dourian T. & Eisenberg M. J. Meta-analysis of usefulness of d-dimer to diagnose acute aortic dissection. Am J Cardiol 107, 1227–1234 (2011). [DOI] [PubMed] [Google Scholar]
- Marill K. A. Serum D-dimer is a sensitive test for the detection of acute aortic dissection: a pooled meta-analysis. J Emerg Med 34, 367–376 (2008). [DOI] [PubMed] [Google Scholar]
- Cui J. S. et al. D-dimer as a biomarker for acute aortic dissection: a systematic review and meta-analysis. Medicine (Baltimore) 94, e471 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Asha S. E. & Miers J. W. A Systematic Review and Meta-analysis of D-dimer as a Rule-out Test for Suspected Acute Aortic Dissection. Ann Emerg Med 66, 368–378 (2015). [DOI] [PubMed] [Google Scholar]
- Sodeck G. et al. D-dimer in ruling out acute aortic dissection: a systematic review and prospective cohort study. Eur Heart J 28, 3067–3075 (2007). [DOI] [PubMed] [Google Scholar]
- Akutsu K. et al. A rapid bedside D-dimer assay (cardiac D-dimer) for screening of clinically suspected acute aortic dissection. Circ J 69, 397–403 (2005). [DOI] [PubMed] [Google Scholar]
- Eggebrecht H. et al. Value of plasma fibrin D-dimers for detection of acute aortic dissection. J Am Coll Cardiol 44, 804–809 (2004). [DOI] [PubMed] [Google Scholar]
- Ersel M. et al. Can D-dimer testing help emergency department physicians to detect acute aortic dissections? Anadolu Kardiyol Derg 10, 434–439 (2010). [DOI] [PubMed] [Google Scholar]
- Fan Q. K. et al. Evaluation of D-dimer in the diagnosis of suspected aortic dissection. Clin Chem Lab Med 48, 1733–1737 (2010). [DOI] [PubMed] [Google Scholar]
- Giachino F. et al. Rule out of acute aortic dissection with plasma matrix metalloproteinase 8 in the emergency department. Crit Care 17, R33 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gorla R. et al. Accuracy of a diagnostic strategy combining aortic dissection detection risk score and D-dimer levels in patients with suspected acute aortic syndrome. Eur Heart J Acute Cardiovasc Care (2015). [DOI] [PubMed] [Google Scholar]
- Hazui H. et al. Simple and useful tests for discriminating between acute aortic dissection of the ascending aorta and acute myocardial infarction in the emergency setting. Circ J 69, 677–682 (2005). [DOI] [PubMed] [Google Scholar]
- Levcik M., Kettner J., Jabor A. & Kautzner J. Utility of plasma D-dimer levels in the diagnosis of acute aortic dissection. Cor et Vasa 55, e510–e514 (2013). [Google Scholar]
- Li W. et al. The value of D-dimer in acute aortic dissection: The experience of China. Atherosclerosis Supplements 11, 197 (2010). [Google Scholar]
- Nazerian P. et al. Combined use of aortic dissection detection risk score and D-dimer in the diagnostic workup of suspected acute aortic dissection. Int J Cardiol 175, 78–82 (2014). [DOI] [PubMed] [Google Scholar]
- Ohlmann P. et al. Diagnostic and prognostic value of circulating D-Dimers in patients with acute aortic dissection. Crit Care Med 34, 1358–1364 (2006). [DOI] [PubMed] [Google Scholar]
- Okazaki T., Yamamoto Y., Yoda K. & Nagahiro S. The ratio of D-dimer to brain natriuretic peptide may help to differentiate between cerebral infarction with and without acute aortic dissection. J Neurol Sci. 340, 133–138 (2014). [DOI] [PubMed] [Google Scholar]
- Peng W. et al. Potential biomarkers for early diagnosis of acute aortic dissection. Heart & Lung 44, 205–208 (2015). [DOI] [PubMed] [Google Scholar]
- Reeps C. et al. Imaging of acute and chronic aortic dissection by 18F-FDG PET/CT. J Nucl Med 51, 686–691 (2010). [DOI] [PubMed] [Google Scholar]
- Sakamoto K., Yamamoto Y., Okamatsu H. & Okabe M. D-dimer is helpful for differentiating acute aortic dissection and acute pulmonary embolism from acute myocardial infarction. Hellenic J Cardiol 52, 123–127 (2011). [PubMed] [Google Scholar]
- Sbarouni E., Georgiadou P., Marathias A., Geroulanos S. & Kremastinos D. T. D-dimer and BNP levels in acute aortic dissection. Int J Cardiol 122, 170–172 (2007). [DOI] [PubMed] [Google Scholar]
- Shao N. et al. The role of D-dimers in the diagnosis of acute aortic dissection. Mol Biol. Rep. 41, 6397–6403 (2014). [DOI] [PubMed] [Google Scholar]
- Spinner T., Spes C. & Mudra H. Elevated d-dimer at acute chest pain: Pulmonary embolism or aortic dissection? Intensivmedizin und Notfallmedizin 3, 570–574 (2006). [Google Scholar]
- Stanojlovic T. et al. Utility of D-dimer testing in ruling out the diagnosis of acute aortic syndrome. European Heart Journal. Acute Cardiovascular Care 2, 177 (2013). [Google Scholar]
- Weber T. et al. D-dimer in acute aortic dissection. Chest 123, 1375–1378 (2003). [DOI] [PubMed] [Google Scholar]
- Xue C. & Li Y. Value of D-Dimers in patients with acute aortic dissection. J Nanjing Med University 21, 86–88 (2007). [Google Scholar]
- Yoshimuta T. et al. Impact of Elevated D-Dimer on Diagnosis of Acute Aortic Dissection With Isolated Neurological Symptoms in Ischemic Stroke. Circ J 79, 1841–1845 (2015). [DOI] [PubMed] [Google Scholar]
- Petra M., Constantine G., Jonathan D., Roger H. & Yemisi T. Cochrane Handbook for Diagnostic Test Accuracy Reviews: Chapter 10 Analysing and Presenting Results (ver 1.0). 2010. Available at http://dta.cochrane.org/handbook-dta-reviews Accessed on December 25th 2015.
- Leeflang M. M., Deeks J. J., Takwoingi Y. & Macaskill P. Cochrane diagnostic test accuracy reviews. Syst Rev 2, 82 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Leeflang M. M., Deeks J. J., Gatsonis C., Bossuyt P. M. & Group C. D. T. A. W. Systematic reviews of diagnostic test accuracy. Ann Intern Med 149, 889–897 (2008). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Harbord R. M. et al. An empirical comparison of methods for meta-analysis of diagnostic accuracy showed hierarchical models are necessary. J Clin Epidemiol 61, 1095–1103 (2008). [DOI] [PubMed] [Google Scholar]
- Booth A. et al. The nuts and bolts of PROSPERO: an international prospective register of systematic reviews. Syst Rev 1, 2 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Moher D., Liberati A., Tetzlaff J., Altman D. G. & Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339, b2535 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Whiting P. F. et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 155, 529–536 (2011). [DOI] [PubMed] [Google Scholar]
- Doebler P. & Holling H. Meta-analysis of diagnostic accuracy with mada. Available from https://cran.r-project.org/web/packages/mada/vignettes/mada.pdf#search=mada+r+systematic+review+diagnostic+accuracy Accessed on November 5th, 2015.
- Doebler P. Package ‘mada’. Available from: https://cran.r-project.org/web/packages/mada/mada.pdf#search=mada+r Accessed on November 5th, 2015.
- Jones C. M. & Athanasiou T. Summary receiver operating characteristic curve analysis techniques in the evaluation of diagnostic tests. Ann Thorac Surg 79, 16–20 (2005). [DOI] [PubMed] [Google Scholar]
- Grimes D. A. & Schulz K. F. Refining clinical diagnosis with likelihood ratios. Lancet 365, 1500–1505 (2005). [DOI] [PubMed] [Google Scholar]
- Righini M. et al. Age-Adjusted D-Dimer Cutoff Levels to Rule Out Pulmonary Embolism The ADJUST-PE Study. Jama-Journal of the American Medical Association 311, 1117–1124 (2014). [DOI] [PubMed] [Google Scholar]
- Schouten H. J. et al. Diagnostic accuracy of conventional or age adjusted D-dimer cut-off values in older patients with suspected venous thromboembolism: systematic review and meta-analysis. Bmj-British Medical Journal 346 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brown M. D. Can a Negative D-dimer Result Rule Out Acute Aortic Dissection? Ann Emerg Med 58, 375–376 (2011). [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.