Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease

Mingjuan Yang 1,*, Yuehua Ke 1,2,*, Xuesong Wang 1,2,*, Hang Ren 1,*, Wei Liu 1,2,*, Huijun Lu 2,3,*, Wenyi Zhang 1,2, Shiwei Liu 4, Guohui Chang 1,2, Shuguang Tian 1,2, Lihua Wang 2,5, Liuyu Huang 1, Chao Liu 1,2,a, Ruifu Yang 2,6,7,b, Zeliang Chen 1,2,8,c
PMCID: PMC4887875  PMID: 27246147

Abstract

Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5–99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9–100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of <34, which accounted for 95.59% of the samples, was 100%. Discordant samples positive by RT-PCR but negative by EBOV-RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.


The ongoing Ebola virus disease (EVD) outbreak in West Africa is the largest since its first discovery in 19761,2,3. As of September 16, 2015, the World Health Organization reported 28,220 confirmed, probable, and suspected EVD cases and 11,291 deaths in Guinea, Liberia, and Sierra Leone4. EVD is an infectious disease characterized by high fatality and rapid progress to an outcome of death or recovery, with a fatality rate of 50–90%5,6,7. For the ongoing outbreak, the fatality rate for confirmed cases (15,199) is 74.3%. Due to the rapid progression to death and the long time required to obtain laboratory results, rapid diagnosis is extremely important for timely triage and treatment8.

EVD patients normally present with non-specific symptoms, including fever, headache, and vomiting. The symptoms of EVD overlap with those of other diseases prevalent in West Africa, which complicates the clinical diagnosis, management, and treatment of EVD patients. EVD is confirmed by laboratory diagnosis, with real-time RT-PCR being the most commonly used assay. The diagnosis of EVD in West Africa involves the collection of blood and/or swab samples, transportation to the field laboratory, and testing by real-time RT-PCR. The entire process from sample collection to obtaining results takes several hours9.

Suspected EVD patients are triaged at holding centers, while confirmed patients are transferred to treatment centers and EVD-negative individuals are discharged after 2 sequential negative tests. At holding centers, samples from suspected patients are collected and sent to the laboratory for diagnosis confirmation. The run time for the laboratory diagnosis ranges from several hours to several days, which is a long time, considering the rapid progression of EVD. A prolonged stay at a holding center also increases the exposure risk to Ebola virus10.

The dipstick test is the most widely used test for point-of-care (POC) diagnosis. This test does not require an external instrument and can be used by technicians with minimal extra training. Broadhurst et al. recently published an evaluation study of the dipstick test for EVD diagnosis11. Despite positive predictive values (PPVs) of 100%, the sensitivity of the dipstick test is limited to samples with cycle threshold values <26.

Considering this situation, the development of a rapid test with high sensitivity is urgently needed. Here, we report the evaluation of a new nucleic acid (NA)-based test, EBOV-RPA, for rapid and sensitive EVD diagnosis. The EBOV-RPA is based on recombinase polymerase amplification (RPA) technology12,13, which is performed at a constant temperature and has a run time shorter than 15 min. The aim of the study was to assess the test performance of the EBOV-RPA assay.

Results

Of all available, common rapid NA-based methods evaluated, the RPA assay—one of the most rapid and specific, was chosen as the detection method14,15. An EBOV-RPA assay that specifically detects strains circulating in the 2014 outbreak was successfully developed. The RPA assay consistently detected as low as 10 copies per reaction (Fig. S1). A simplified sample treatment procedure that avoids NA extraction was developed (Table S2). With the simplified procedure, the EBOV-RPA assay can be completed in 20 minutes.

The performance evaluation study was carried out in Sierra Leone (Fig. 1). We enrolled 408 patients, of whom 15 were subsequently excluded, leaving 393 to be tested by EBOV-RPA and RT-PCR. Of these 393 patients, 8 were invalid by EBOV-RPA, 2 were invalid by RT-PCR, 5 pending by RT-PCR, and 3 had serious hemolysis; the remaining 375 patients showing valid RPA and RT-PCR results were included in the final analysis (Fig. 1). Of the 361 suspected EVD patients with available demographic information, 241 (66.8%) were from the Western Area Urban District of Sierra Leone, 109 (30.2%) were from the West Area Rural District, and 11 (3.0%) were from other districts (Table 1). The ages of these suspected patients ranged from 0 to 96 years (mean: 30.6, 95% CI: 26.9–34.3), and 166 (52.8%) of them were female. The median symptom onset time after specimen collection was 4.66 days (range: 0–16, 95% CI: 3.86–5.45) in the 248 patients with available data. Of these patients, 278 have recorded symptom information. The most prevalent symptoms included weakness (86.8%), loss of appetite (84.4%), fever (82.2%) and muscle pain (69.0%). A significant proportion of these suspected EVD patients had multiple symptoms: 130 (46.8%) of them had 6–10 symptoms, and 76 (27.3%) had >11 symptoms. Of these patient samples, 144 (58.15%) were collected in <3 days, 83 (33.5%) were collected in 4–7 days, and 21 (8.5%) were collected in over 7 days.

Figure 1. Overview of the EBOV-RPA evaluation study.

Figure 1

Table 1. Demographic characteristics of enrolled suspected EVD patients.

Characteristics No. (%) of Patients
Sex (n = 314)
 Female 166 (52.8)
Age (n = 359), Mean (range, 95% CI) 30.6 (0–96, 26.9–34.3)
 ≤18 101 (28.1)
 18–45 193 (53.8)
 >45 65 (18.1)
District of origin (n = 361)
 Western urban 241 (66.8)
 Western rural 109 (30.2)
 Others 11 (3.0)
Symptom onset to specimen (n = 248), mean (range, 95% CI)
 ≤3 144 (58.1)
 4–7 83 (33.5)
 >7 21 (8.5)
Symptom
 Fever 221 (82.2)
 Vomiting/nausea 177 (66.5)
 Diarrhea 151 (56.8)
 Weakness 230 (86.8%)
 Loss of appetite 221 (84.4%)
 Abdominal pain 167 (64.5%)
 Chest pain 81 (60.4%)
 Muscle pain 185 (69.0%)
 Joint pain 178 (67.7%)
 Headache 160 (61.1%)
 Cough 66 (49.6%)
 Difficult breathing 91 (34.9%)
 Difficult swallowing 88 (34.0%)
 Sore throat 54 (42.2%)
 Jaundice 39 (31.7%)
 Red eye 116 (45.8%)
 Skin rash 37 (14.6%)
 Hiccups 60 (22.6%)
 Sensitive to light 34 (26.6%)
 Coma 22 (16.9%)
 Confused of disoriented 54 (41.9%)
 Unexplained bleeding 7 (4.9%)
Multiple symptom (n = 278)
 1–5 70 (25.2)
 6–10 130 (46.8)
 ≥11 76 (27.3)

After excluding invalid samples or test results, 375 samples were included in the final evaluation analysis. The overall sensitivity was 97% (95% CI: 95.5–99.3) and the specificity was 97% (95% CI: 93.9–100; Table 2). For blood samples, the sensitivity was 97% (95% CI: 95.1–99.4) and the specificity was 97% (95% CI: 93.1–100), and for swab samples, the sensitivity was 98% (95% CI: 94.3–100) and the specificity was 97% (95% CI: 91.6–100). We next analyzed the sensitivity and specificity of the RPA assay for samples with different Ct values. For 255 samples (96.59%) with Ct values <34, the sensitivity for both sample types was 100%. For the 10 samples (3.79%) with Ct values of 34–36, the overall sensitivity was 70%, and the sensitivity was 66.7% for blood samples and 100% for swabs. For 6 samples (2.27%) with Ct values >36, the sensitivity was 33.3% for blood samples and 0% for the only swab sample. For all the 3 Ct ranges, the PPV was 100% (Table 3). ROC analysis showed that the EBOV-RPA assay is highly sensitive and specific; the AUC was 0.9652 (Fig. S4).

Table 2. Overall performance of RPA versus RT-PCR.

Sample type Sensitivity (%, 95% CI) Specificity (%, 95% CI) PPV (%) NPV (%) Positive LR Negative LR
Blood and swabs (n = 375) 264/271 (97, 95.5–99.3) 101/104 (97, 93.9–100) 99 94 33.8 0.03
Blood (n = 288) 213/219 (97, 95.1–99.4) 67/69 (97, 93.1–100) 99 92 33.6 0.03
Swabs (n = 87) 51/52 (98, 94.3–100) 34/35 (97, 91.6–100) 98 97 34.3 0.02

Table 3. Performance of RPA in terms of sample type and different Ct value ranges.

Sample type Ct value range
<34 34–36 >36
Blood and swab
 Percent (%) 96.59 3.78 2.27
 Sensitivity (%) 255/255 (100) 7/10 (70) 2/6 (33.3)
 PPV(%) 100 100 100
Blood
 Sensitivity (%) 205/205 (100) 6/9 (66.7) 2/5 (40.0)
 PPV(%) 100 100 100
Swab
 Sensitivity (%) 50/50 (100) 1/1 (100) 0/1 (0)
 PPV(%) 100 100 100

The Ct value distribution of these tested samples was analyzed, with 134 samples (49.45%) having Ct values <26, 121 (44.65%) with Ct values in range of 26–34, and only 16 (5.9%) with Ct values >34 (Table S3). Viral loads were calculated from Ct values using a standard curve. The viral loads of the tested samples ranged from 103 to 1010 copies/mL. The viral loads of swabs were lower than that of the blood samples (Fig. S2). The mean of the threshold time of EBOV-RPA was significantly shorter than that of RT-PCR (Table S3; 5.53 vs. 37.78 minutes, F = 225.401, p < 0.001), indicating that EBOV-RPA amplification is more rapid than RT-PCR (Fig. S3).

The RPA assay was also used to detect the blinded samples for external quality assessment (EQA), which was sponsored by the WHO. Of the 10 blinded samples, 5 had inactivated EBOV, while the other 5 had EBOV RNA. The EBOV-RPA results were completely consistent with those of RT-PCR (Table S5), and samples with low Ct values in RT-PCR also showed low Ct values by EBOV-RPA. The RPA assay yielded results in 30 min, while RT-PCR yielded results approximately 2 h later. According to the assessment result, our EQA tests were 100% correct and the EBOV-RPA assay was more rapid.

Compared with RT-PCR, EBOV-RPA generated discordant results for a few samples. RNA from the discordant samples positive by RT-PCR, but negative by EBOV-RPA, was re-tested by EBOV-RPA. Of these samples, 1 was positive and the other 6 were still negative. The Ct values of all 5 samples were >34. The discordant samples were also tested with another RT-PCR kit (Ebov-NP) targeting the NP gene. All 10 samples positive by Ebov-GP were also positive by Ebov-NP; however, the 2 samples positive by EBOV-RPA but negative by Ebov-GP were also positive by Ebov-NP (Table 4). This indicated that the 2 samples in question were not false positives.

Table 4. Confirmation of discordant samples between the RT-PCR and EBOV-RPA assays.

Sample type Ebov-GP Ebov-NP EBOV-RPA Sample EBOV-RPA RNA
B 34 33.02 NA 15.94
B 35 33.8 NA NA
B 35.3 34.22 NA NA
B 36.5 35.04 NA NA
S 36.5 35.12 NA NA
B 37.5 36.41 NA NA
B 38.5 37.26 NA NA
B NA 37.68 16.5 ND
B NA 36.42 20.6 ND
S NA NA 12.8 ND

B: blood sample; S: swab sample; Ebov-GP: the kit targeting the EBOV GP gene; Ebov-NP: the kit targeting the EBOV NP gene; EBOV-RPA sample: sample detection by the EBOV-RPA assay; EBOV-RPA RNA: detection of extracted RNA; NA: not available; ND: not detected; “−” not applicable.

Discussion

The time from symptom onset to outcome in EVD is <10 days on average6. However, because of the time required for sampling, transportation, laboratory diagnosis, and obtaining results, the diagnosis and timely treatment of suspected EVD patients is delayed, increasing the risk of exposure to other persons16,17. Mara et al. recently reported field validation of the dipstick immunoassay for EVD. Although a PPV of 100% was reported, the test was only applicable for samples with high virus load11. Indeed, there is a significant proportion of clinical samples with low virus load. The dipstick assay cannot accurately define these samples as negatives. Alternatively, the samples need to be further defined by RT-PCR in a reference laboratory. Therefore, there is a need for a rapid test that can detect EBOV accurately. In the current outbreak, laboratory testing with real-time PCR is widely used in the affected areas. However, the requirements of sophisticated thermocycler and complex sample treatment procedures have limited its applications in point-of-care testing18. Recombinase polymerase amplification (RPA) overcomes the technical difficulties posed by current amplification methods. It does not require thermal denaturation of template and operates at a low and constant temperature, without reliance on expensive thermocycler. In combination with a novel fluorescent probe, it can be monitored with a portable, real-time fluorometer, with portable battery pack. RPA has also been shown to be highly resistant to crude samples in comparison to PCR, suggesting applications in on-the-spot field testing with crude nucleic acid extraction19.

Using RPA technology, we developed and evaluated a new assay that detects the EBOV NA gene. The principle of RPA is similar to that of RT-PCR but is performed under isothermal conditions. Thus, the amplification time is <15 min, or approximately one-fourth that of the most rapid RT-PCR assay. Furthermore, the sensitivity of the RPA assay is comparable to that of RT-PCR. The RPA assay has been successfully used to detect bioterrorism pathogens and many other microorganisms15,20,21. By analyzing the genome sequences of the 2014 outbreak strains, we identified a conserved genomic region as a signature sequence for development of the EBOV-RPA assay, which ensured that the assay could more specifically detect the currently circulating strains. After optimization, the assay could detect as few as 10 copies per reaction. Because NA extraction is time consuming, a simplified sample treatment that avoided the extraction step without compromising sensitivity was successfully developed. This simplified procedure renders the RPA assay feasible for rapid diagnosis.

Sensitivity is essential for a rapid test. The overall sensitivity, specificity, PPV, and NPV of the EBOV-RPA assay for the panel of 375 samples demonstrated suitable performance of the assay for rapid EVD diagnosis. Most importantly, the PPV for all tested samples was 100%, i.e., the samples positive by EBOV-RPA were true positive samples. For samples with Ct values <34 (representing 94.1% of the samples), the sensitivity was 100% for both sample types. Therefore, EBOV-RPA is very accurate for EVD diagnosis. We further analyzed the discordant samples positive by RT-PCR but negative by EBOV-RPA. All 6 false-negative samples identified by EBOV-RPA had Ct values >35, 4 of which were in the gray zone (Ct = 36–40) of the Ebov-GP kit. Compared with RT-PCR, EBOV-RPA generated 3 false positives according to the Ebov-GP kit. However, further confirmation by the Ebov-NP kit showed that 2 of them were actually true positives. This in consistence might be that both EBOV-RPA and Ebov-NP target NP genes of Ebola virus. These results also implied that for the clinical diagnosis of EVD, a 2-target strategy would improve the diagnostic accuracy.

Although the RPA assay was not compared directly with the dipstick assay, both assays were compared with RT-PCR. We evaluated the advantage of RPA by putatively compared with dipstick assay. The RPA assay offers several advantages over the dipstick assay. Firstly, the RPA assay is specific, sensitive and easy to develop over a short period of time. As with real-time PCR, the RPA assay used a primer pair and a probe highly specific for the target sequence22. RPA can detect samples with Ct values up to 32 with 100% sensitivity and is thus 100-fold more sensitive than the dipstick method. A possible reason for the enhanced sensitivity is that the RPA assay targets the NA gene, while the dipstick assay targets an antigen. Secondly, RPA assay results could be quantitatively generated in the form of virus titer levels. For the dipstick assay, the operator reads the result and it can be difficult to define whether a given sample is positive or negative. Lastly, the short run time of the RPA assay is the main advantage over the dipstick assay. While dipstick assay can be used with minimal training and does not require power to get a result, RPA assay can be performed without nucleic acid extraction and monitored by portable fluorometer with battery. These characteristics make RPA of great importance for rapid diagnosis of EVD.

The present study has a limitation. The evaluation study was not performed under real POC conditions, such as Ebola holding centers or treatment centers. However, we performed the tests under environments simulating the POC conditions. We think that the sensitivity and specificity of the RPA assay should not have been affected by the operating site, despite this limitation.

In summary, we evaluated a rapid NA test for rapid diagnosis of EVD. The superior performance of the EBOV-RPA and its comparable performance to RT-PCR indicate that it is also appropriate for laboratory diagnosis. The RPA assay thus shows great potential for POC testing of infectious diseases, particularly emerging infectious diseases.

Methods

Ethics statement

This study was conducted as part of the surveillance and public health response to contain the 2014 EVD outbreak in Sierra Leone. Samples were collected for EVD testing and outbreak surveillance during the EVD outbreak under an agreement between the Sierra Leone and Chinese governments. Treatment was conducted in accordance with the protocols for viral hemorrhagic fever under the urgent interim guidance for case management established by the WHO. The protocol for this study was approved by the Ethics Committee of the Department of Health in Freetown. Written informed consent was given to every patient enrolled prior to the start of this study.

Development of the EBOV-RPA assay

A pair of primers and 1 probe were designed to specifically detect Ebola Zaire viruses including circulating strains from the 2014 EBOV outbreak (Table S1). The sequence spanning the amplification region was synthesized and cloned into the pSQ380-MS2 plasmid to generate pSQMS2-NP. Armored RNA was prepared from pSQMS2-NP. The RT-RPA assay was performed in a 50-μL volume using the TwistAmpTM Exo Kit (TwistDx, Cambridge, UK), 420 nM RPA primer F and R, 120 nM exo-probe, and 14 mM magnesium acetate. All reagents except for the template or sample RNA and magnesium acetate were prepared in a master mix, which was aliquoted into each tube of a 0.2-mL 8-tube strip containing a dried enzyme pellet13. Magnesium acetate was pipetted into the tube lids. Subsequently, 2 μL sample was added to the tubes. The lids were closed, and the magnesium acetate was centrifuged into the tubes using a mini-spin centrifuge. The tubes were immediately used for amplification and detection. Ten-fold serial dilutions of armored RNA standard ranging from 108 to 101 molecules/μL were tested by the EBOV-RPA assay in 8 replicates. The Ct number was plotted against the number of molecules in each tube comprising the standard curve. The lowest concentration of the dilution that could be detected was determined as the detection limit.

EBOV-RPA and RT-PCR reactions

The prepared RPA assay tubes were run on a Tube Scanner device (Qiagen Lake Constance, Stockach, Germany), Mini-8 real-time PCR system (Coyote, Beijing, China), or LightCycler LC96 Real-Time PCR System (Roche, Switzerland). Fluorescence was monitored at 42 °C for 15 min. For the Tube Scanner, the reaction temperature was set at 42 °C. The reaction conditions included a 1-min pre-incubation, followed by fluorescence measurement at intervals of 20 s for 14 min. The results obtained with the Tube Scanner were used to define the threshold time, at which point the fluorescence intensity increased exponentially. For the real-time PCR systems, a real-time PCR-like protocol was used: 1 min of pre-incubation at 42 °C, followed by 30 cycles of 42 °C 10 s and 42 °C for 10 s (fluorescence detection in channel of FAM). The RPA results obtained on the real-time PCR systems were defined in terms of Ct values. The RT-PCR assays, including those obtained with the Ebov-GP and Ebov-NP kits that specifically detect GP and NP respectively, were run on a LightCycler LC96 system essentially as recommended by manufacturer (Puruikang Biotechnology Co., Ltd, Shenzhen, China)23. Briefly, a 25-μl reaction system contained 20 μl reaction solution A, 2 μl reaction solution B, and 3 μl RNA extracts. Cycling conditions consisted of an initial 42 °C step for 5 min and 94 °C for 10 s, followed by 40 cycles of 94 °C for 5 s, 55 °C for 30 s (florescent signal collection, FAM channel), and 25 °C for 10 s.

Simplified sample treatment

Aliquots (10 μL) of the blood or swab samples were mixed with AVL, Trizol, and sample solution (Coyote, Beijing, China) at ratios of 2:1, 1:1, 1:2, and 1:4. The mixtures were heat-treated at 98 °C for 3 min and then centrifuged at 3000 × g for 1 min. The supernatants were diluted 2, 4, 8, 16, and 32-fold and then used in the EBOV-RPA test. The sample treatment resulting in the shortest threshold time was chosen as the simplified sample treatment method.

Evaluation procedure

The EBOV-RPA assay evaluation study was performed at the China-CDC JUI laboratory at Freetown, Sierra Leone. An overview of the evaluation study is depicted in Fig. 1. Sample aliquots were subjected to viral RNA extraction or simplified treatment of heat denaturation. The extracted RNA or treated samples were studied by EBOV-RPA or RT-PCR assays by different staff members. Two other staff members blinded to the assays independently recorded the results, which were not shared with clinicians or used for medical management. RT-PCR results were subsequently recorded. All staff participating in the study followed strict biosafety precautions according to WHO guidelines.

Whole blood or swab samples from suspected EVD patients were sent to the JUI laboratory (JUI lab) for Ebola testing. Several batches of samples were sent to JUI lab for testing each day. Samples received before 1:00 PM were selected for the evaluation study so that the samples could be treated and tested on the same day. Samples from suspected EVD patients who completed a questionnaire form were included. Samples were excluded when not correctly stored, transported, or stored for >48 hours after sampling. Once received, the samples were brought into a BSL-3 mobile laboratory for sample treatment, and sample aliquots were subjected to RNA extraction with QIAamp Viral RNA Mini Kit (Qiagen, Germantown, MD, USA) or simplified treatment as described above. Extracted RNAs were detected by RT-PCR in a BSL-2 laboratory, and simplified treated samples were detected by EBOV-RPA in another simulated point-of-care zone.

Statistical analysis

The test sensitivity is the proportion of all RT-PCR-positive samples that are positive by EBOV-RPA. The test specificity is the proportion of all RT-PCR-negative samples that are also negative by EBOV-RPA. Data analysis was performed using SPSS, version 17.0. Continuous variables were analyzed with one-way ANOVA and Student’s t-test. The chi-squared test was used for categorical independent and paired variables. The cutoff value was determined by performing receiver operating characteristic (ROC) analysis, in which the sensitivity and specificity were calculated as a function of the cutoff value. The value of 1-specificity was plotted against the sensitivity, and the areas under the ROC curves (AUCs) were calculated. p < 0.05 was considered statistically significant.

Additional Information

How to cite this article: Yang, M. et al. Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease. Sci. Rep. 6, 26943; doi: 10.1038/srep26943 (2016).

Supplementary Material

Supplementary Information
srep26943-s1.doc (2.7MB, doc)

Acknowledgments

This work was supported by grants from the China Mega-Project on Infectious Disease Prevention (2013ZX10004-203, 2013ZX10004805-006), the National Natural Science Foundation of China (8155100001), and the Beijing Key Laboratory of POCT for Bioemergency and Clinics (BZ0329). The funding sources had no role in the conception and execution of this project. We thank the government of Sierra Leone, the Sierra Leone Ministry of Health and Sanitation, and the Chinese National Health and Family Planning Commission. We also thank the medical workers and volunteers in Sierra Leone.

The authors declare no competing financial interests.

Author Contributions Z.C., R.Y., C.L. and L.H. conceived of the project; M.Y., Y.K., H.R., X.L. and S.L. participated in developing the RPA assay; Z.C., H.L., X.W. and W.L. performed the clinical sample evaluations; W.Z. contributed to the collection of information; Z.C., S.L. and M.Y. analyzed the data and drafted the manuscript, and R.Y. revised the manuscript; G.C., S.T. and L.W. participated in sample treatment and diagnosis.

07/11/2016

The version of this Article previously published incorrectly listed Mingjuan Yang, and not Chao Liu, Ruifu Yang and Zeliang Chen as corresponding authors. Correspondence and request for materials should be addressed to liuchao9588@sina.com, ruifuyang@gmail.com and zeliangchen@yahoo.com. This has now been corrected in the PDF and HTML version of the paper.

References

  1. Baize S. et al. Emergence of Zaire Ebola virus disease in Guinea. N Engl J Med 371, 1418–1425 (2014). [DOI] [PubMed] [Google Scholar]
  2. Maganga G. D. et al. Ebola virus disease in the Democratic Republic of Congo. The New England journal of medicine 371, 2083–2091 (2014). [DOI] [PubMed] [Google Scholar]
  3. Chertow D. S. et al. Ebola virus disease in West Africa–clinical manifestations and management. The New England journal of medicine 371, 2054–2057 (2014). [DOI] [PubMed] [Google Scholar]
  4. WHO. Ebola situation report-16 September 2015 http://apps.who.int/ebola/ebola-situation-reports-16-september-2015 (2015). [Google Scholar]
  5. Qin E. et al. Clinical Features of Patients With Ebola Virus Disease in Sierra Leone. Clinical infectious diseases 61, 491–495 (2015). [DOI] [PubMed] [Google Scholar]
  6. Schieffelin J. S. et al. Clinical illness and outcomes in patients with Ebola in Sierra Leone. The New England journal of medicine 371, 2092–2100 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Barry M. et al. Clinical predictors of mortality in patients with ebola virus disease. Clinical infectious diseases 60, 1821–1824 (2015). [DOI] [PubMed] [Google Scholar]
  8. Walker N. F. et al. Evaluation of a point-of-care blood test for identification of Ebola virus disease at Ebola holding units, Western Area, Sierra Leone, January to February 2015. Eurosurveillance 20, 1–6 (2015). [DOI] [PubMed] [Google Scholar]
  9. Zhang W. et al. Field Labs in Action for Ebola Control in Sierra Leone. Infectious Diseases and Translational Medicine 1, 2–5 (2015). [Google Scholar]
  10. Kost G. J. et al. Molecular detection and point-of-care testing in Ebola virus disease and other threats: a new global public health framework to stop outbreaks. Expert review of molecular diagnostics 1–15 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Broadhurst M. J. et al. ReEBOV Antigen Rapid Test kit for point-of-care and laboratory-based testing for Ebola virus disease: a field validation study. Lancet 386, 867–874 (2015). [DOI] [PubMed] [Google Scholar]
  12. Euler M. et al. Recombinase polymerase amplification assay for rapid detection of Francisella tularensis. J Clin Microbiol 50, 2234–2238 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Euler M. et al. Recombinase polymerase amplification assay for rapid detection of Rift Valley fever virus. Journal of clinical virology 54, 308–312 (2012). [DOI] [PubMed] [Google Scholar]
  14. Piepenburg O., Williams C. H., Stemple D. L. & Armes N. A. DNA detection using recombination proteins. Plos Biology 4, e204 (2006). [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Euler M. et al. Development of a panel of recombinase polymerase amplification assays for detection of biothreat agents. J Clin Microbiol 51, 1110–1117 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Kaushik A., Tiwari S., Dev Jayant R., Marty A. & Nair M. Towards detection and diagnosis of Ebola virus disease at point-of-care. Biosensors & bioelectronics 75, 254–272 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Matanock A. et al. Ebola virus disease cases among health care workers not working in Ebola treatment units–Liberia, June-August, 2014. MMWR. Morbidity and mortality weekly report 63, 1077–1081 (2014). [PMC free article] [PubMed] [Google Scholar]
  18. Frieden T. R., Damon I., Bell B. P., Kenyon T. & Nichol S. Ebola 2014–new challenges, new global response and responsibility. N Engl J Med 371, 1177–1180 (2014). [DOI] [PubMed] [Google Scholar]
  19. Mekuria T. A., Zhang S. & Eastwell K. C. Rapid and sensitive detection of Little cherry virus 2 using isothermal reverse transcription-recombinase polymerase amplification. J Virol Methods 205C, 24–30 (2014). [DOI] [PubMed] [Google Scholar]
  20. Ren H. et al. Development of a rapid recombinase polymerase amplification assay for detection of Brucella in blood samples. Molecular and cellular probes 30, 122–124 (2016). [DOI] [PubMed] [Google Scholar]
  21. Abd El Wahed A. et al. A portable reverse transcription recombinase polymerase amplification assay for rapid detection of foot-and-mouth disease virus. Plos One 8 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Vasoo S., Stevens J. & Singh K. Rapid antigen tests for diagnosis of pandemic (Swine) influenza A/H1N1. Clinical infectious diseases: an official publication of the Infectious Diseases Society of America 49, 1090–1093 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
  23. Wang G. et al. The evaluation of 7 commercial real-time PCR kits for Zaire ebolavirus using virus-like particle-encapsulated EBOV RNA. Diagnostic microbiology and infectious disease 83, 355–358 (2015). [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information
srep26943-s1.doc (2.7MB, doc)

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group