Abstract
A patient with mild multiple sclerosis died from a ruptured intracranial aneurysm. It was possible to relate abnormalities of somatosensory evoked potentials recorded some months earlier to a plaque involving the root entry zone in the cervical spinal cord which had not resulted in clinical sensory abnormalities.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Jones S. J. Short latency potentials recorded from the neck and scalp following median nerve stimulation in man. Electroencephalogr Clin Neurophysiol. 1977 Dec;43(6):853–863. doi: 10.1016/0013-4694(77)90008-6. [DOI] [PubMed] [Google Scholar]
- Matthews W. B., Beauchamp M., Small D. G. Cervical somato-sensory evoked responses in man. Nature. 1974 Nov 15;252(5480):230–232. doi: 10.1038/252230a0. [DOI] [PubMed] [Google Scholar]
- Small D. G., Matthews W. B., Small M. The cervical somatosensory evoked potential (SEP) in the diagnosis of multiple sclerosis. J Neurol Sci. 1978 Feb;35(2-3):211–224. doi: 10.1016/0022-510x(78)90004-7. [DOI] [PubMed] [Google Scholar]
- Wiederholt W. C. Recovery function of short latency components of surface and depth recorded somatosensory evoked potentials in the cat. Electroencephalogr Clin Neurophysiol. 1978 Aug;45(2):259–267. doi: 10.1016/0013-4694(78)90009-3. [DOI] [PubMed] [Google Scholar]