A data comparison between a traditional and the single-step β-galactosidase assay

Jorrit Schaefer 1, Goran Jovanovic 1, Ioly Kotta-Loizou 1, Martin Buck 1,
PMCID: PMC4908277  PMID: 27331113

Abstract

This article describes reproducibility of a single-step automated β-galactosidase, and the equivalence of its data to the traditional assay (“Experiments in Molecular Genetics” [1]). This was done via a pairwise comparison of both methods using strains with Miller Unit [MU] values ranging from 0 to over 2000. The data presented in this article is associated with the research article entitled “A single-step method for mid to high throughput β-galactosidase assays in Escherichia coli using a microplate reader” [2].

Keywords: LacZ, B-galactosidase, β-Galactosidase, B-Gal, β-Gal, Microplate reader

Specifications Table

Subject area Biology
More specific subject area Enzymatic assays
Type of data Table
How data was acquired FLUOstar Omega Microplate Reader (BMG LABTECH)
Data format Raw/Analysed
Experimental factors None applied
Experimental features β-galactosidase assay
Data source location Imperial College Road, Imperial College, London SW7 2AZ, UK
Data accessibility Data is with this article

Value of the Data

  • Validates a single-step automated assay to measure β-galactosidase activity in E. coli with a microplate reader.

  • Establishes the method provides consistent data, with a coefficient of variation similar to that of the traditional assay.

  • Student׳s t-test demonstrates equivalence of the single-step and the traditional assay data.

1. Data

The data presented in this article is a pairwise comparison of the MU activities of the traditional β-galactosidase assay and a single-step automated method [2]. 4 different strains with MU activities (0–10, 40–70, 500–900, and 1800–2400 respectively) were assayed using both methods.

2. Experimental design, materials and methods

2.1. Cell culture and sample preparation

Samples were grown overnight at 37 °C in LB media. For the traditional assay, samples were treated as described by Miller [1]. For the single-step automated microplate assay, 80 μL of culture was transferred into 96-well Costar® flat bottom microplates (Sigma-Aldrich). 120 μL of a custom mix was added to each well used, including the blank (containing 80 μL LB). The custom mix consists of 60 mM Na2HPO4, 40 mM NaH2PO4, 10 mM KCl, 1 mM MgSO4, 36 mM β-mercaptoethanol, 166 µL/ml T7 lysozyme, 1.1 mg/ml ONPG, 6.7% PopCulture® Reagent. The Costar microtitre plates were then placed in a FLUOstar Omega Microplate Reader (BMG LABTECH).

2.2. Kinetic OD600 and OD420 measurements

The FLUOstar Omega Microplate Reader was set to 30 °C, with OD600 and OD420 readings taken every 60 s for 1 h (20 flashes per well each cycle). Wells were set to shake at 500 rpm (double orbital shaking) between readings to ensure homogenisation of the sample and more efficient lysis. A script to run these parameters on a FLUOstar Omega Microplate Reader can be found in Supplementary Data A.

2.3. MARS Data Analysis

The MARS Data Analysis software package was used to process the OD600 and OD420 data generated by the by FLUOstar Omega Microplate Reader. Miller Units values are expressed as follows:

MillerUnits=1000*(OD420/min)OD600*volume used(ml)=1000*(OD420/min)(OD600*2.5)*0.080=5000*(OD420/min)OD600

The kinetic OD420 readings were converted into the slope of OD420 over time (OD420/min), multiplied by 5000, and adjusted for the initial OD600 reading at the first time point. The obtained MU values were then compared to those of the traditional assay (Table 1). More detailed lab notes on running this assay and subsequent processing in MARS Data Analysis are available in Supplementary Data B.

Table 1.

The single-step automated assay was consistent over multiple orders of magnitude and generated data equivalent to that of the traditional assay. The coefficients of variation of the Miller Unit [MU] measurements using the one-step and the traditional assay were similar for all β-galactosidase expressing strains suggesting that the two methods have comparable precision and reproducibility. Additionally, no statistically significant difference was observed between the single-step and traditional β-galactosidase assay (two-tailed Student׳s t-test assuming unequal variance; P>0.05).

One-step assay
Traditional assay
T-test
[MU] Average Coefficient of variation [MU] Average Coefficient of variation P value
MG1655 ΔlacZ −13 −2 1.1 1.1 0.71
12 1.3
−5 1


 

 

 

 

 

 

 


MG1655 ΔlacZ ΦPpspAlacZ 87 69 0.23 52 42 0.18 0.12
48 35
72 37


 

 

 

 

 

 

 


MG1655 ΔlacZ ΦPpspAlacZ ΔpspA 691 649 0.05 665 676 0.01 0.35
642 677
613 686


 

 

 

 

 

 

 


MC1061 ΔlacZ ΦPpspAlacZ ΔpspA 2985 2600 0.11 2070 2202 0.09 0.17
2464 2473
2351 2062

2.4. Data comparison between the single-step β-galactosidase assay and the traditional assay

See Table 1.

Acknowledgements

This work was supported by BBSRC (BB/J00717X/1) and MRC (MR/M017672/1) project grants.

Footnotes

Transparency document

Supplementary data associated with this article can be found in the online version at http:dx.doi.org/10.1016/j.dib.2016.05.063.

Appendix A

Supplementary data associated with this article can be found in the online version at http:dx.doi.org/10.1016/j.dib.2016.05.063.

Transparency document. Supplementary material

Supplementary material

mmc1.docx (11.6KB, docx)

Appendix A. Supplementary material

Supplementary material

mmc2.zip (4.3KB, zip)

Supplementary material

mmc3.docx (57.4KB, docx)

References

  • 1.Miller J.H. CSH Laboratory Press; Cold Spring Harbor, NY: 1972. Experiments in Molecular Genetics. [Google Scholar]
  • 2.Schaefer J., Jovanovic G., Kotta-Loizou I., Buck M. Single-step method for β-galactosidase assays in Escherichia coli using a 96-well microplate reader. Anal. Biochem. 2016 doi: 10.1016/j.ab.2016.03.017. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary material

mmc1.docx (11.6KB, docx)

Supplementary material

mmc2.zip (4.3KB, zip)

Supplementary material

mmc3.docx (57.4KB, docx)

Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES