Abstract
Electromechanical coupling in electroactive polymers (EAPs) has been widely applied for actuation and is also being increasingly investigated for sensing chemical and mechanical stimuli. EAPs are a unique class of materials, with low-moduli high-strain capabilities and the ability to conform to surfaces of different shapes. These features make them attractive for applications such as wearable sensors and interfacing with soft tissues. Here, we review the major types of EAPs and their sensing mechanisms. These are divided into two classes depending on the main type of charge carrier: ionic EAPs (such as conducting polymers and ionic polymer–metal composites) and electronic EAPs (such as dielectric elastomers, liquid-crystal polymers and piezoelectric polymers). This review is intended to serve as an introduction to the mechanisms of these materials and as a first step in material selection for both researchers and designers of flexible/bendable devices, biocompatible sensors or even robotic tactile sensing units.
Keywords: sensor, electroactive polymer, conducting polymer, dielectric elastomer, liquid-crystal elastomer, piezoelectric polymer
1. Introduction
Electroactive polymers (EAPs) are polymers that undergo shape and/or dimensional change in response to an applied electrical field [1,2]. EAPs are a subset of electroresponsive polymers (ERPs), which exhibit electrically coupled responses in general [3]. The earliest study on EAPs was performed by Roentgen [4] and Sacerdote [5], who were working on the deformation of a dielectric polymer induced by an electric field. EAPs are attractive to people working on electrically driven soft actuators [1,2], as some EAPs such as dielectric elastomers [6,7] can handle much larger strains than their equivalent conventional actuator materials, such as piezoelectric ceramics. EAP artificial muscles are strongly comparable to biological muscle due to their response to electrical stimulation, though their operation mechanism is significantly different [1,8]. Besides actuators, EAPs have revealed their potential in other applications [1,2,8–11] such as sensors, electronic components and energy generators. EAPs are suitable for sensory applications ranging from haptic sensing [10] to blood pressure and pulse rate monitoring [12] and even chemical sensing [13]. This is due to numerous favourable properties: facile fabrication, high mechanical flexibility, customizable electromechanical coupling properties and tailorable geometries [1,2,8–11]. Furthermore, coupling EAPs into micro-electro-mechanical systems (MEMS) has been discussed by both the EAP [14] and MEMS [15] communities.
EAPs can generally be classified into two categories: ionic EAPs and electronic EAPs [1]. The electrical activation of ionic EAPs [1] is due to the migration of ions or molecules (solvents). Some examples of ionic EAPs are conducting polymers (CPs) [16,17] and ionic polymer–metal composites (IPMCs) [18,19]. Electronic EAPs [1] are activated by applied electric fields and Coulomb forces. Dielectric elastomers [20,21], electrostrictive polymers [22], liquid-crystal polymers [23,24] and piezoelectric polymers [25] belong the electronic EAP category.
EAPs comprise a family of promising materials for sensing, but are still new to most researchers working on sensor-related topics. Since there is no material that can cover all sensory requirements, the selection of a material should be made carefully to suit individual requirements [2]. EAPs should certainly be considered complementary to conventional sensing materials, especially in areas where high strains and conformity to soft materials is desired. In this article, we review such materials and aspects of their associated sensing mechanisms. Major categories of ionic and electronic EAPs in sensory technologies are discussed, along with a number of illustrative examples.
2. Ionic electroactive polymers for sensing
2.1. Introduction to ionic electroactive polymers
Ionic EAPs usually work at low voltages (less than 5 V [11] for actuation). Additionally, many materials used in the synthesis of ionic EAPs, such as polypyrrole (PPy) and poly(3,4-ethylenedioxythiophene) (PEDOT) are usually biocompatible. Thus, such EAPs are suitable for applications in biological environments [2]. Ionic EAPs normally require an ion reservoir to operate, so that ions or molecules can be transported within them. Owing to the presence of ions in these EAPs, they share some common features as responsive materials: (i) the stress and/or strain applied to these materials will cause ion migration and perturb the charge distribution; (ii) the properties of ionic transport into electrodes and/or through an electronic separator will influence the overall outcomes in applications such as sensing and actuation. Further discussion on their advantages and disadvantages will be given in table 3. Most ionic EAPs can be further categorized into CPs, IPMCs and polymer gels [1,2]. Carbon nanotubes [26] have recently been added to this group as well [27]. Here, we focus on CPs, IPMCs, carbon nanotubes and their derivatives.
Table 3.
Summary comparing the pros and cons of the major EAPs discussed in this review.
EAPs for sensing |
||
---|---|---|
pros | cons | |
ionic EAPs | ||
conducting polymers | chemical stability, miniaturization, facile fabrication process, low-cost, low-weight, biocompatibility, soft, multiformable (sheet, film, tubular, trilayer), response to mechanical, electrical, chemical and thermal stimulation | insufficient adhesion onto substrate, fragile upon mechanical and thermal loading |
ionic polymer–metal composites | low-weight, biocompatibility, miniaturization, soft, large produced voltage signal, sensitive to large bending deformation, ability to work in wet environments | hysteresis, sensitive to moisture and temperature during operation, operation limited to low temperature due to liquid electrolyte, slow response |
carbon nanotubes | high surface area to volume, high sensitivity, miniaturization, directional mechanical and electrical properties | expensive, slow response, difficult to control intrinsic properties during fabrication |
electronic EAPs | ||
dielectric elastomers | large sensing range, low-cost, light-weight, stability in many working cycles, and capability as self-sensing actuators | defect-sensitive, rare for stress measurement, not sensitive to compression in normal direction, may be affected by temperature |
liquid-crystal elastomers | potential for high strain changes, potential high sensitivity to strain | complex and expensive synthesis and processing of the materials |
piezoelectric polymers | wide bandwidth, fast electromechanical response, relatively low-power requirements, high generative forces | relatively low output performance originating from charge dissipation. Some materials need to be stretched and poled to gain higher output |
2.2. Sensors based on conducting polymers
CPs or intrinsically conducting polymers (ICP) are organic polymers that are electronically conductive with relatively high and reversible ion storage capacity. The mechanisms of both mechanical sensing and actuation are similar and based on the insertion and expulsion of ions into and from the polymer structure—the structure itself being ionically as well as electronically conductive [28]. Depending on external stimuli and the produced output, this kind of material can be used as an actuator or sensor.
Two different configurations have been used for CP-based sensor devices. One is a free-standing film of CPs, which operates in an electrolyte. Another configuration is the trilayer structure, which is made of two CP layers at the top and bottom, with an electrically non-conductive separator layer between them. The separator layer, which is ionically conductive, works as an ion reservoir and also as an electrical insulator. Trilayer sensors with an electrolyte within a separator layer can function in air and do not need an external electrolyte.
2.2.1. Free-standing films of conducting polymers
The mechanochemoelectric effect (which results in ionic and electronic currents produced by mechanical deformation) was observed in a free-standing film (figure 1) of conducting polymer by Takashima and co-workers in 1997 [29]. In this process, mechanically induced charge is converted into electrical energy. This energy is proportional to the magnitude of the applied load and the dimensional change of the film. The efficiency of this conversion was estimated to be less than 0.01%, and the induced voltage was of the order of a few microvolts [29]. It was also shown that this mechanochemoelectric phenomenon is reversible and that the induced charge for all cycles was nearly the same. CPs' ability to measure relatively large strains (10 times larger than typical piezoelectric sensors) and their low mechanical impedance (Young's modulus) makes this kind of sensor potentially useful for multiple applications such as instrumentation to detect strain and force [30]. Additionally, tensile strain can be measured by a free-standing film of CP.
Figure 1.
Schematic of free-standing film of conducting polymer as a linear force sensor before and after applying tension.
There are two hypotheses dealing with the mechanism behind this voltage generation. In one suggested mechanism, if the conducting polymer film or layer is compressed, the mechanical deformation leads to an increase in the concentration of mobile ions relative to the ionic concentration in the external electrolyte. Typically, the mobile ion species is either cationic or anionic, with charge being balanced by the electronic charge on the polymer backbone or by bulky, immobile counter-ions. This concentration difference and the mechanical stress on the mobile ions cause net expulsion of the mobile ions from the polymer structure and generate a voltage difference that is detectable by open circuit measurements [31]. Similarly, increasing mechanical tension in the polymer structure increases the volume of the polymer, leading to a decrease in ion concentration. This causes an influx of mobile ions of one type into the polymer (anions are shown in figure 1), leading to a voltage difference. An alternative theory suggests that ions are inserted or expelled directly as a result of mechanical stress, not due to changes in concentration [30]. This applied mechanical stress can be related to generated voltage by CP sensors as an output.
A linear relationship between generated voltage and applied stress was reported by Shoa et al. [30] for a PPy free-standing film. The generated voltage ΔV is related to applied stress, σ by the following equation: ΔV = αsσ; where the strain to charge ratio for sensing, αs is an empirical linear coefficient. The sensor response is relatively stable in the frequency range 0.1–100 Hz.
Based on the sensing mechanism in CPs, counter-ions play an important role in the conversion of mechanical energy to electrical energy, and vice versa. Madden [32] also predicted the charge generation due to mechanical deformation in CPs. He also mentioned the relationship between voltage polarity (±V) and the type of counter-ion [32].
Ergonomic comfort, elasticity, high thermoresistivity and piezoresistivity of the PPy conducting polymer have attracted some researchers to use it in wearable e-textiles in biomedicine [9] and wearable electronics [33]. Examples include the deposition of a thin layer of PPy on a Lycra/cotton fabric to make a sensitive glove [34], and coating elastomeric fabric to make an intelligent knee sleeve to provide feedback on knee flexion angle [35]. Although the material has several interesting properties in the context of wearable devices, its long response time to reach steady state (in a few minutes) is the major limitation for practical usage [9].
Gas or chemical sensors are another interesting application for CPs, as the absorption of gas molecules leads to a change of electrical conductivity in the polymer matrix. Compared to sensors based on metal oxides, conducting polymer-based chemiresistors have several improved characteristics such as higher sensitivity and shorter response times [36]. The sensitivity of the PPy conducting polymer to ammonia, nitrogen dioxide, carbon dioxide and organic vapours, such as alcohols and ethers has been reported [36–39].
CPs have also been employed in the design and fabrication of biosensors [40]. Facile electro-polymerization, and their potential for miniaturization and functionalization by doping or grafting, make CPs good candidates for use as suitable substrates for DNA sensors [41,42]. Meanwhile, stability, ability to be modified by enzyme to exhibit different analytical characteristics, and electrode protection from fouling and interfering material are some advantages of CPs for electrochemical biosensing applications [43].
Conducting polymer free-standing films can be produced by electrodeposition, as is often done with PPy [44]. Low-temperature deposition produces films with good electrical and mechanical properties [30,44]; these are doped, during growth, with anions. Although anions often constitute the mobile charges, large anions such as dodecylbenzenesulfonate (that are essentially immobile) can be inserted during electrodeposition [45–47], creating cation-transporting sensors. The detected voltage in cation-transporting sensors is in opposite polarity when compared with anion-transporting sensors. Unlike PPy, polyaniline is soluble, and can be cast to create films [29]. In chemical deposition, PEDOT, PPy and polyaniline can also be deposited from the monomer in vapour or liquid phase, in the presence of an oxidizing agent that drives polymerization on or within a substrate [48–50].
2.2.2. Trilayer structure based on conducting polymers
Figure 2 shows a bending trilayer sensor, with the expanded layer being penetrated by mobile ions, while mobile ions are expelled from the contracted layer on the opposing side due to mechanical stress and the increase in ion concentration. Stress effects may also occur in ions in the separator layer. The generated potential difference between two layers can be detected by an open circuit potential measurement, or by detecting a short circuit current. The voltage difference produced is given by the strain to charge ratio multiplied by the applied stress. Typical values of strain to charge ratio are 10−11–10−10 m3 C−1, so that a 1 MPa stress produces voltages between 0.02 and 0.06 mV, and large charges of between 2000 and 6000 C m−3 [30,32]. The charge produced in thin films is large compared with piezopolymers (piezoelectric polymers, which convert pressure to voltage—refer to §3.4).
Figure 2.
Schematic of (a) a bending trilayer sensor. In (b), a trilayer sensor is deflected by a finger, and (c) shows an example of measured open circuit potential generated by brief mechanical stimuli. The direction of the peak (up or down) is related to the direction of mechanical excitation. The magnitude of voltage spikes in this example is approximately 10 mV. Pushing a trilayer to the left generates an upward peak, while pulling the trilayer to the right generates a downward peak, with the positive electrical connection on the (left/right) side. A video about the tri-layer conducting polymer sensor and actuator is available in the electronic supplementary material.
A mechanical bending-type trilayer sensor using PPy as the CP layers was investigated by Wu et al. [31]. They observed millivolt signals in response to millimetre deflection, which generated 1000 C m–3 charge for 1% strain in the PPy film. Sinusoidal voltage output was detected in response to sinusoidal displacement excitation. A linear relationship between induced strain and charge density during bending deformation of the trilayer sensor was observed. They also reported that the strain to charge ratio is the ion-dependent parameter and is different for different ions, and sensor response can be improved by using ions that have larger strain to charge ratio.
Tensile and compressional strain can also be measured by conducting polymer-based sensors in trilayer configurations. PEDOT conducting polymer was used as a mechanical sensor in a trilayer configuration [51]. The output voltage in response to ±2% sinusoidal strain was measured at approximately 0.20 mV, with the same frequency as the input signal. A linear relationship between applied strain and the output voltage (in open circuit potential measurement) was reported.
Interesting results by Otero and his team [52] report the change in consumed electric energy by a trilayer PPy-based device in response to changes in load. It was observed that during the application of a constant current between two PPy electrodes in a trilayer arrangement, there is a linear increase in consumed electrical energy with respect to load. They also reported that this energy drops linearly with respect to increasing temperature. These properties allow this device to be used as a sensor for both mechanical load and temperature. In a similar study, the tactile sensitivity of the trilayer was investigated. The PPy trilayer was used to push an obstacle, and a linear relationship between applied potential and obstacle weight was obtained [53]. The materials' key properties have been extensively characterized by different groups. These properties include sensitivity (the minimum detectible physical signal) [54,55], linearity (linear relationship between input and output) [56], their operation at the micro-scale [55,57] and frequency response [58].
Trilayer structures (figure 3) are formed with porous or ionically conducting material as the substrate, onto which two layers of conducting polymer are applied (top and bottom).
Figure 3.
Schematic of fabrication of conducting polymer-based trilayers (a) CP/Au/PVDF/Au/CP structure, gold is sputtered on the PVDF membrane and then the CP layer is deposited by electrochemical deposition. (b) PEDOT/IPN/PEDOT structure, PEDOT is polymerized inside the IPN film by chemical deposition, which creates a PEDOT penetrated layer at the top and bottom of the IPN film with density gradient of PEDOT towards the surface.
Wu et al. [31] and subsequent papers from Alici and colleagues [56,58,59] employ porous polyvinylidenedifluoride (PVDF) as the substrate, onto which a thin layer of platinum (or gold [59]) is sputtered on each side. PPy films are electrochemically deposited on the metal layers. Microstructures can be produced by creating thin porous layers of PVDF [31,60,61]. An approach that was used by a team at the University of Cergy-Pontoise involved the synthesis of films containing ionically conductive poly(ethylene oxide) (PEO) interpenetrated with an elastomer (nitrile butadiene rubber). The latter affords mechanical stability, imparting high mechanical elasticity and ionic conductivity to the resulting interpenetrating polymer network (IPN) [48,51,62]. The EDOT monomer is deposited onto the substrate surface. Following penetration into the substrate, it is polymerized to create a very robust and ionically conductive trilayer sensor/actuator combination [48,63–65]. Recent work has shown a resonant frequency of 900 Hz in an actuated microstructure [62]. Freedom from delamination is one of the major advantages of PEDOT/IPN/PEDOT trilayer structures for long-term operations (more than 3.5 × 106 cycles).
Trilayers based on CPs deposited on PVDF or PEDOT/IPN/PEDOT trilayers can be swollen with ionic liquids or other salts dissolved in different electrolytes to function in air as a sensor (e.g. 0.1 M LiTFSI in propylene carbonate [66–68]). Stiffness, deflection, current and frequency response are tailored by varying length, width and thickness.
Otero and Cortés fabricated a very simple triple layer sensor; they electrodeposited the PPy film on AISI 304 stainless steel. To control the adherence to the metal, the morphology and the stability, they applied square wave potentials between –0.3 V (2 s) and 0.872 V (8 s). After deposition they taped PPy-deposited film on stainless steel with double-sided plastic tape, and peeled off the film and taped the other side of the tape to new PPy-deposited film and peeled it off again. Finally, they made the PPy/double-sided plastic tape/PPy triple layer sensor [52,53].
2.3. Sensors based on ionic polymer–metal composites
Similar to the CPs, IPMC sensors and actuators also work based on the movement of ions, but with different mechanisms and structures. IPMCs have trilayer structures, involving a combination of ionic polymers and metallic electrodes. IPMCs are reported as both sensors and actuators [10,19,69–71]. Working as sensors, their great sensitivity to physical stimuli such as mechanical force (which can induce bending on the IPMC sensors, figure 4) makes them very attractive [72,73]. Unlike sensors based on CPs, IPMCs are mainly used as mechanical sensors. Therefore, this section mainly focuses on mechanical sensing based on IPMCs.
Figure 4.
Schematic of an IPMC sensor. Application of force leads to bending of the IPMC and expansion (dilution of ions) at the top and contraction (concentrating ions) at the bottom, which causes a concentration gradient. Difference in concentration leads to migration of mobile cations (surrounded by water molecules) towards the diluted section. Owing to change of charge amount carried by cations between electrodes, potential difference is generated between the electrodes. This potential can be measured by open circuit voltage.
In 1970s, Grodzinsky & Melcher [74] demonstrated electromechanical transduction in collagen membranes. They proved experimentally that both mechanical-to-electrical and electrical-to-mechanical transductions are possible in the polyelectrolyte membranes used [74]. IPMC-based vibration sensors were reported by Sadeghipour et al. in 1992 [75]. The output voltage versus applied tip displacement upon bending a cantilevered IPMC was measured by Mojarrad and Shahinpoor [76]. The magnitude and direction of the output voltage were found to be dependent on the magnitude and direction of the forced-induced deformation. Another experiment using IPMC as a mechanical sensor was conducted by Ferrara et al. [77].
IPMC is normally established in a trilayer fashion with the metallic electrode attached on the top and bottom of an ionic polymer layer [78,79]. Ionic polymers are considered polyelectrolytes, formed by a fixed, covalently bound network of immobile ionic repeat charge units (hydrophilic). These are covalently bound to repeat units which are sometimes grafted onto a network of a non-ionic polymer (hydrophobic). The hydrophilic, microstructured network creates porosity, enhancing the charge transport of oppositely charged mobile counter-ions when swollen in the presence of diluent [69] (figure 4). Acidity, or the ion exchange capacity (IEC), of the ionic polymer membrane indicates the capacity for the counter-ions storage; the ion conductivity of the ionic polymer indicates ion mobility across the membrane [69]. IEC and ionic conductivity are the two major characteristics of ionic polymers as sensors and actuators. Both of them depend on the structure of the membrane. Meanwhile, the ionic conductivity is also related to the size and charge of the counter-ions as well as electrolyte type and uptake [80]. However, the tensile modulus usually decreases when ionic conductivity is increased by higher diluent uptake. The main research efforts in this area are to synthesize ionic polymers with higher ionic conductivity (operating in both hydrated and dry conditions), improved stability (chemical and thermal) and enhanced mechanical properties (e.g. strength) [69,81]. DuPont's Nafion [82], Flemion, Aciplex, Aquivion (Hyflon) and other synthesized sulfonated aromatic ionic polymers have been reported as polyelectrolytes for IPMC sensing and/or actuation [69]. A typical ionic polymer consists of perfluorinated alkenes with short side chains terminated by ionic groups (e.g. sulfonic or carboxylic acid groups for cation exchange, or ammonium cations for anion exchange). The volume proportion of polymer backbones determines the mechanical strength of IPMCs: the higher the volume proportion, the higher the mechanical strength. Metallic electrodes can be formed by either chemical reduction (such as electroless plating [83]) or physical deposition (such as sputtering [84]). Metals that have been used successfully as electrodes are platinum [85,86], copper [87], silver [83], palladium [84] and gold [88,89].
The theory behind IPMC mechanical sensing was covered in a handful of review papers [18,69,78,90]. Two methods to measure mechanical deformation have been proposed, as described below.
In the first method, the generated potential difference between electrodes is measured. The IPMC's mechanical sensing properties were explained by the charge imbalance of ion migration by mechanical deformation [19]. When the external force is imposed on the IPMC sensor, due to the stress/strain gradient, shifting of mobile cations becomes possible and they move towards the expanded region to balance the concentration of ions. The gradient of charge along the thickness of the IPMC sensor (figure 4) generates a potential difference which can be detected by a low-power amplifier or open circuit potential measurement [18,91,92]. The hypothesis behind this mechanism of sensing is that the charge density is proportional to the induced strain [93].
In the second measurement method, the surface resistance of the metallic electrode of IPMC is measured. This resistance changes with expansion and contraction of the electrodes. When the electrode is stretched the resistance increases, and compression of the electrode decreases the resistance. In the case of bending IPMCs under applied force or strain, the resistance of one side increases while the other side decreases. This difference between resistances of both surfaces is correlated to the bending curvature and also increases cumulatively. The measured resistance difference between electrodes is used to calculate the radius of curvature, which leads us to find the applied strain. A four-probe system is employed to measure the surface resistance of the electrodes [94,95].
IPMCs can be used for both static and dynamic mechanical sensing. They demonstrate potential in sensing curvature variation for engineering structures [96], fluidic flows [97], force [98] and even the inclination (angle change) of a body [99]. Though the electromechanical coupling properties of IPMCs are found to be influenced by the solvent [100,101] and other conditions such as the humidity of the environment [102], chemical sensing based on IPMCs is rarely explored. Some IPMCs are soft and non-toxic hydrophilic materials, which show great potential for biomedical applications. Multifunctional tactile sensors [103], muscle movement detectors [104], blood pressure, pulse rate and rhythm sensors [12], pressure sensors in human spines [77] and hand prosthetic applications [10] based on IPMCs have been demonstrated.
2.4. Sensors based on carbon nanotubes
Application of voltage to carbon nanotube electrodes immersed in an electrolyte results in charge to the electrodes. This charge is balanced by the counter-ions from the electrolyte. Insertion/expulsion of ions into/from the carbon nanotubes can generate positive and negative strain and enable carbon nanotube electrodes to work as an actuator. Inversely, doping carbon nanotubes with some molecules can produce a potential difference or change the electrical conductivity. Change in nanotube structures or change in electrical conductivity can be sensed and enable carbon nanotubes to be employed as sensors.
Carbon nanotubes (CNTs) have drawn much attention due to their unique properties, including their one-dimensional nature, high stiffness and strength, thermal conductivity, ballistic transport and high surface area [105]. CNTs exhibit actuation and sensing behaviour due to their ability to store both charge and molecules. Storing charge in carbon nanotubes causes change in their length and produces strains of up to 1%. Conversely, charged CNTs in the form of yarns can generate voltage when tensile stress of up to several hundred megapascals is applied [106]. In the case of the force sensor, similar mechanisms to CPs have been suggested for CNT-based sensors. Axial mechanical tension increases the length of the yarns, which leads to radial compaction. This reduction in diameter decreases the available inner surface area for ion interaction and causes expulsion of interior ions. The ion expulsion produces an inward current into the yarns explained by Mirfakhrai et al. [106]. Chemical vapour deposition (CVD), arc-discharge technique and laser ablation are the main methods used in the preparation of the CNT layer [105].
Very large surface-to-volume ratio means the carbon nanotubes have high adsorptive capability: ideal for use in gas or chemical sensors. As the electronic properties of the nanotubes change with atomic structure and chemical doping, they are suitable for sensor miniaturization while maintaining high sensitivity. As shown in figure 5, when the gas molecules are absorbed by the CNT(s) layer and work as dopants, the conductivity of this layer changes, which causes variation in resistance between two Au contacts [105,107,108].
Figure 5.
Schematic of a CNT gas sensor. The CNT layer is used between two electrodes, and the current response to constant applied voltage is measured. Change in resistance of the CNT layer, which causes change in current, shows gas absorption.
CNTs have been employed in electrochemical sensing to enhance sensitivity, especially in biosensing applications [109,110]. Excellent conductivity, absorptivity and biocompatibility are other advantages of CNTs as electrochemical biosensors [110–114].
2.5. Sensors based on other ionic electroactive polymers
Other ionic EAPs, such as hydrogels [2,115,116], have also been studied for sensing applications. The sensitivity of the hydrogels to some physical parameters such as temperature [117], pH [117,118], electrical voltage [119], salt concentration [120] and concentration of organic materials in water [121] make them interesting materials for using in chemical sensor applications and biosensors such as DNA and protein detection [122].
Smart hydrogel or stimuli-responsive hydrogels can change their volume by more than one order of magnitude and reversibly convert chemical energy into mechanical energy [119]. Using hydrogel with different techniques for sensor applications has been reported [40,123]. Swelling the hydrogel, which causes bending of the thin silicon plate to change the output voltage, is one of the demonstrated approaches. Adding a hydrogel layer to the micro-pressure sensor can help to monitor the analyte-dependent swelling of the hydrogel to detect the change in solution. The diffusion-driven mechanism of the hydrogels gives them slow response times, but this can be improved through miniaturization. The response time of such materials is affected by the viscoelastic and hysteresis behaviour of the hydrogel [123].
3. Electronic electroactive polymers for sensing
3.1. Introduction to electronic electroactive polymers
Unlike ionic EAPs, electronic EAPs are free from any electrolyte medium. No ion migration is required for the electromechanical coupling. Therefore, electronic EAPs require a shorter time period for response or relaxation than ionic EAPs: this can be less than 1 ms [11]. Thus, electronic EAPs can also work at higher frequencies than ionic EAPs for dynamic sensing. Dielectric elastomers, electrostrictive polymers, liquid-crystal elastomers (LCEs, typical flexoelectric polymers) and piezoelectric polymers are the main subgroups within electronic EAPs [1,2]. In the following subsections, we will focus on dielectric elastomers, LCEs and piezoelectric polymers as they are more studied in sensory applications.
3.2. Sensors based on dielectric elastomers
A dielectric elastomer (DE) sensor is a type of strain sensor that detects the change of capacitance in a capacitor-like system. In this section, the design and mechanism of DE sensors is briefly introduced, and the benefits and drawbacks are also discussed to help both theoretical understanding and potential application.
DE sensors are based on a system with two compliant electrodes and an intermediate dielectric layer (formed from a long chain polymer with suitable electric permittivity and film thickness). These systems are DE transducers [21,124,125], which include DE actuators [6,126–129], DE sensors [130] and DE generators [131–133].
Development of EAPs based on DE materials can be traced back to Roentgen's work in 1880 [4]. In his experiment, he observed the deformation of a piece of natural rubber when a high electrical field was applied to it. This is the first reported instance of DE actuation. Figure 6a shows the basic concept of DEAs. When a voltage is applied to the two compliant electrodes (black sheets shown in figure 6) at the top and bottom of the elastomer, these two electrodes mutually attract and tend to move towards each other, thus squeezing the elastomer by the electrostatic force (also known as Maxwell stress) and inducing a reduction in thickness. Assuming the elastomer is incompressible with a positive Poisson's ratio, there must be a lateral expansion in the plane normal to the direction of the electrical field. Since the electrodes are compliant, they will expand with the elastomer without electrical disconnection during the deformation process. When the applied voltage is removed, the whole system reverts back to its original state.
Figure 6.
Schematic diagrams show the mechanisms of operation for a DE in (a) actuator and (b) sensor modes. When applying voltage across the actuator, the attracting force between electrodes makes the DE film contract in thickness but expand in lateral directions. When laterally stretching the sensor, the change in capacitance (C to C’) can be correlated to the strain due to stretching.
DE sensors can have a similar basic design to DE transducers (but without the application of high voltage) to detect changes in strain. This is done by measuring the capacitance across the elastomer after deformation by stretching, relaxing or compressing. Figure 6b depicts a typical design of DE sensor. When the system is going through deformation due to applied force, the capacitance created by the electrodes changes with the planar area and the thickness of the system, as described in the following equation: C = ɛ0ɛr A/d; where C is the capacitance, ɛ0 is the vacuum permittivity, ɛr is the relative permittivity of the DE material, A is the overlapping area of the two electrodes on opposite sides of the DE membrane and d is the distance between the two electrodes (also the thickness of the DE film). For example, in figure 6b, if the system is expanded laterally by applying force in the planar direction (stretching), the capacitance will increase from C to C’ since A increases and d decreases. Thus, by measuring the change in capacitance with a capacitance meter or an LCR (inductance (L), capacitance (C) and resistance (R)) meter, the amount of deformation can be calculated [6].
For practical cases, DE sensing may not be as simple as this, since the voltage drop across the electrode, due to resistance and current leakage through the dielectric layer, must be taken into account. Recently, a transmission line model reported by Xu et al. [134–136] considered the full impedance of the circuit. This model can better analyse output signals at higher sensing frequency, and can also be used to achieve local detection within the same film [134–136].
In an ideal DE sensor system the electrodes must satisfy two requirements: (i) they must not over-constrict deformation of the DE layer; and (ii) they must stay in conformal contact with the polymer layer during deformation in order to guarantee conductivity. Disconnection of the electrodes during large deformations can cause malfunctions in the system. Meeting these two requirements, the electrode materials can be carbon powder [137,138], silver paint [139], metallic thin film [139], carbon grease [128,140], CPs [139], carbon nanotubes [141], hydrogel with electrolyte [142,143] or graphene [144], and conductive elastomer-based compounds [138,145]. Among these, carbon grease is recommended for fast prototyping and is most widely used since it retains high conductivity during large strain. It is also cost effective and easy to apply to different DE layers [146]. On the other hand, the selection of DE layers also affects the performance of sensors. Since the measured strain is directly related to the change in capacitance, the permittivity of the DE layer should be as large as possible to maximize sensitivity [21]. So far, the most common DE material used in this type of sensor is silicone rubber due to its fast response and low (viscoelastic) hysteresis [125].
Compared with conventional materials used for sensors that are relatively stiff and may fail at low strains [125], DEs can provide a larger range for strain sensing, since strains of 300% have been reported in DE transducers [147], which allow their use in haptic communications or tactile displays [124,148]. Additionally, the fabrication of DE sensors is simple and affordable, and their low weight and stability over many working cycles show potential for applications in the micro-robotics field and biomedical applications such as orthotics and prosthetics [124,149,150]. By integrating DE actuators and DE sensors, a self-sensing actuator can be established. The self-sensing DE actuator has been designed and investigated extensively [151–158]. Furthermore, numerous studies have reported this by measuring capacitance during actuation to monitor the change in strain [158–161]. This design paves the way for micro-scale actuators, since independent sensing devices are not needed. Inevitably, there are some aspects in which DE sensors can be improved, such as inhomogeneity of the materials, the temperature dependence of the elastomer's properties, and conversion between strain and stress in some DE sensors [21,162]. Solving these technical challenges would lead to even wider commercial applications for DE sensors.
Owing to DE sensors' high robustness, reliability, well-costed and well-understood manufacturing process, they are probably the most successful EAP mechanical sensors with regard to their commercialization—with numerous patents [163,164] based on DE sensors and transducers. This is further shown in companies like Parker [165] and StretchSense [166] that have developed sensors based on dielectric elastomers; these can detect stretching, pressure, bending and shear, as well as changes in strain and temperature. StretchSense have integrated these sensors with Bluetooth, an example of well-established pre-existing technology, showing the ready adaptability and ease-of-use of DE sensors. The readouts from the products of both companies can also be transmitted directly to a users' mobile phone.
It has been mentioned by Böse [167] that sensing in the normal direction might be less efficient, compared with sensing lateral stretching. When a compression force acts perpendicular to the film surface, the DE film behaves nearly incompressibly, resulting in a small deformation and a corresponding increase in the capacitance of the flexible capacitor. To better measure the stress load in the normal direction, a novel design has been recently introduced [167]. The basic principle of this sensor is shown in figure 7. The DE elastomer film is embedded between two profiled surfaces in a sandwich configuration. When the sensor mat is compressed, the profiles penetrate into each other, thereby stretching the DE film. This conversion of pressure load to strain leads to a large increase in the capacitance of the DE film, thus enabling detection of stress in the normal direction.
Figure 7.
Basic principle of a DE pressure sensor with wave profiles. This figure is based on one previously published in [167].
In summary, DE sensors are an additional use of DE transducers. By measuring the capacitance change of a system composed of two compliant electrodes with a DE layer in between, the strain due to an applied force can be measured. It is a good choice due to its high strain and large deformation range measurement, easy fabrication, low-cost, light-weight, repeatability, and also its ability to achieve self-sensing DE actuators in micro-scale applications. Limitations such as inhomogeneity during fabrication also exist. Therefore, proper testing and careful assessment depending on application requirements are necessary when choosing DE sensors as the method to measure strain. Nonetheless, the DE sensor is by far the most successful EAP used so far for mechanical sensing, with well-developed manufacturing techniques and numerous commercial products available in the market.
3.3. Sensors based on liquid-crystal polymers
Liquid-crystal (LC) ‘phases' are intermediate phases between the crystalline state (in which molecules are spatially fixed into a very ordered arrangement) and the liquid state (in which molecules are fully disordered) [168]. There are many types of LC phases, and they are categorized by the type and degree of ordering in the molecules making up the material. Increasing disorder can be caused either by increasing temperature, or by adding small solvent molecules. The type of molecules that form LC phases are usually long, rigid rods, and the anisotropy present at molecular level gives LC phases their unusual behaviour. While the LC material is partially disordered, and so retains the ability to flow (like a liquid), it can also display crystal-like optical properties such as birefringence.
If the anisotropic LC molecules are simply chemically joined together to form a long chain, then this ability to flow is hindered and the material simply becomes crystalline; if, however, they are tethered to a long chain molecule which is quite ‘soft’ (i.e. having a low glass transition temperature) then some ability to flow can be maintained. Furthermore, if some chemical linking points are present between these soft chains, then LC phase changes can cause changes in the bulk dimensions of the material. This type of material is termed an LCE [169,170] and can show some really remarkable shape changes; many can shrink by one-third of their length when heated, but shrinking of up to 80% of the original length of the material has been reported [171].
The schematic in figure 8a shows how such a shrinkage can occur; if the mesogens show orientational alignment across the whole of the material (this is termed a ‘monodomain nematic’), then heating causes an increase in disorder and a shrinking of the material along the LC director. This change is reversible. To make LCEs responsive to electric fields, a small amount of a conducting ‘filler’ material (such as carbon nanotubes or magnetic nanoparticles) can simply be added to the LCE, as shown in figure 8b [24,174]. In this case, an applied electrical potential causes a flow of current, which heats the material. Then, a dimensional change is caused by the same mechanism as described above. Care must be taken in processing these materials; if the filler is added in too high a concentration, the material can become stiff and dimensional change is hindered.
Figure 8.
Schematic diagrams to show LCE actuating and sensing behaviour, where (a) shows how the ordered ‘nematic’ phase becomes isotropic during thermal-induced actuation, with a corresponding contraction along the LC director; and (b) when small magnetic particles are added to the LCE, liquid crystalline order is preserved (particles not drawn to scale). When this material is placed in a rapidly changing electromagnetic field (e.g. inside a solenoid carrying an AC current) the magnetic particles' temperature is raised, causing the same type of contraction as in (a). (c) A ‘cholesteric’ LCE, with a helical variation in the direction of the LC mesogens, changes pitch when force is exerted in the direction of the helicoidal structure; this can lead to the generation of an electric field and is potentially useful in strain sensing [172]. The mechanism by which this field is generated is discussed more fully in [173].
Certain chiral LCs are, however, sensitive to electrical fields even without an added filler. In order for materials to be ferroelectric (i.e. having a permanent electrical polarization in the absence of an external electrical field), they must fulfil certain symmetry requirements; most types of LC phases have very high symmetry and therefore are not candidates for ferroelectric behaviour [175]. However, in 1975 a team of researchers predicted that in the smectic C LC phase (in which the rigid LC mesogens are arranged in layers, but tilted with respect to the layer direction), and if the molecules are chiral, then a spontaneous polarization arises [175]. This prediction was successfully proven experimentally and has since led to considerable research in the field of ferroelectric liquid crystals (FLCs) [176], which have been commercialized in the field of LC displays due to their rapid switching times. When incorporated into a cross-linked matrix (forming an LCE), they can potentially show piezoelectric effects (i.e. the ability to either produce an electrical current when subjected to mechanical stress, or to show a dimensional change in response to an electrical voltage).
When ferroelectric LCs are chemically bound to a soft polymer network, forming an LCE as described above, the material can undergo contraction when exposed to an external electric field [23,177,178]; the strain changes reported were rather low, approximately 4% in response to applied fields of the order of 1 MVm−1 [23]. These materials also tend to be rather soft (with an elastic modulus of the order of MPa), so that, although the applied field causes a strain change, the material is not capable of exerting a large force. Stiffer materials have been fabricated by swelling an LC polymer network to form a gel [179]. These materials have been investigated as electrical actuators (converting electrical signals into a mechanical force) but less extensively for sensing applications. However, some studies on the piezoelectric nature of these materials indicate that surface charges of the order of tens of picocoulombs can be obtained by the application of forces of the order of newtons, and these values are dependent on the temperature at which the procedure is carried out [180].
Strain sensing has also been investigated in the so-called ‘bent-core’ LC polymers. Figure 9 shows schematically how the bending of such a material can lead to an overall change in the electrical polarization, as well as providing an example of a polymerizable bent-core mesogen. As their name suggests, these LCs are rigid mesogenic units that have one bend along their length to form an L-shape; an example is shown in figure 9c. This gives rise to novel behaviours, because they can form chiral phases even when the LC mesogens used to create them are achiral. These materials have promise in the field of piezoelectric sensors: under mechanical bending, currents of tens of nanoamperes can be generated [181,182]. This phenomenon has been termed ‘flexoelectricity’ and has been studied both experimentally and theoretically [184].
Figure 9.
(a) Schematic diagram showing a ‘bent-core’ LC mesogen chemically bound to a polymer network. (b) A bending distortion creates a change in the overall electrical polarization of the material. (c) A typical molecular structure of a polymerizable bent-core mesogen [181–183]. (Online version in colour.)
Piezoelectric effects (which will also be detailed in the next section) have been observed in ‘cholesteric’ LCEs, in which the LC mesogens show helical ordering (and, therefore, chirality). It was predicted theoretically that such cholesteric effects should exist, before experiments showed that piezoelectric voltages of millivolts could be generated [172,173,185]. This type of cholesteric LCE is depicted schematically in figure 8c. An interesting recent study showed that cholesteric LC polymers can be made to change their colour in response to humidity and temperature [186].
In summary, LCEs show considerable potential in mechanical sensing due to their tunability and their capacity to undergo large strain changes. Barriers to commercialization include the complexity and expense of their synthesis. While their use as actuators (in which an external trigger causes them to undergo shape change) has been extensively explored, there is considerable scope to extend their use in generating electrical signals in response to external stimuli.
3.4. Sensors based on piezoelectric polymers
The term ‘piezoelectric’ originates from the Greek word ‘piezo’, which means ‘pressure’, and refers to the propensity of certain materials to generate electrical charges on their surfaces in response to an applied pressure. Conversely, when an electrical potential is applied across the material, mechanical deformation results.
In general, most of the well-known piezoelectric materials are inorganic [187–190] due to their high piezoelectric strain constant (d, the mechanical strain produced by an applied electric field). However, these piezoelectric ceramics require high processing temperatures if thin films with dipole orientation are required. In addition, to gain the highest performance, lead-containing materials, such as lead zirconium titanate (PZT) [191,192], should be used. To counter these drawbacks, polymer piezoelectric materials have been proposed as substitutes. Polymer piezoelectric materials have significant advantages; in addition to their soft elasticity, both the materials and processing equipment required are inexpensive [193–195]. As a result, piezoelectric polymers enable the fabrication of flexible sensors [196–206], energy generators [207–210] and organic-based field-effect transistors [211] for the next generation of smart technology. Furthermore, although piezoelectric polymers have lower piezoelectric strain constants, they present better piezoelectric voltage constants (g, the electric field produced by a mechanical stress) due to the low dielectric permittivity of the polymer, as described in the following equation: g = d/(ɛoɛr); where g is piezoelectric voltage constant, d is piezoelectric strain constant, ɛo is the vacuum permittivity, ɛr and is the relative permittivity of the piezoelectric materials. This indicates that piezoelectric polymers are particularly well suited to sensor applications involving the detection of pressure or human motion [212,213]. Here, we are focusing on the mechanical sensing aspect; however, some piezoelectric polymers can be used in other sensory applications, such as pyrometers, flame and thermal sensors. These sensors will be discussed in a later part of the section.
Figure 10a presents a schematic of a tactile sensor using the piezoelectric polymer polyvinylidene fluoride-trifluoroethylene (P(VDF-TrFE)). The design of a typical piezoelectric tactile sensor is that of a two-plate capacitor with the piezoelectric polymer as the dielectric material, where the applied force induces a charge across the capacitor which is sensed by a voltage or charge amplifier circuit. Figure 10b illustrates typical output voltage characteristics of the piezoelectric polymer tactile sensor under low-frequency vibration (5 Hz) [136]. This device shows an alternating current shaped output signal with a peak voltage 0.3 V under 0.1% s–1 of strain rate. The magnitude and frequency of applied stress should be considered significant since the shape of the output signal is determined by those factors [214].
Figure 10.
(a) Schematic of a P(VDF-TrFE)-based tactile sensor. (b) Output voltage of P(VDF-TrFE)-based tactile sensor when impacted with low-frequency (f = 5 Hz) vibrations using a magnetic shaker. Red circles indicate the deformation states of the piezoelectric polymer film. (c) Schematic drawing of the piezoelectric polymer-based tactile sensor mechanism based on atoms. Structure of PVDF in the all-trans configuration and its dipole moment (P). Red arrows indicate the separation (r) between hydrogen (orange circle) and fluorine (green circle) atoms.
The atomic structure of piezoelectric polymer materials is the most significant factor in understanding the sensing mechanism of piezoelectric polymer tactile sensors. Figure 10c shows the atomic structure and dipole moment (P) of polyvinylidene fluoride (PVDF), which is one of the most cited and widely used piezoelectric polymer materials [193,194] due to its high electromechanical coupling property, approximately 28 pC−1 N [215]. PVDF has a spatially symmetrical arrangement of hydrogen and fluorine atoms along the polymer chain. In this spatial arrangement, the difference between electron preference (electronegativity) of atoms generates polarization in the molecules [216]. P(VDF-TrFE), which is used as a sample tactile sensor (figure 10a), is a copolymer of PVDF, and the additional side group helps the polymer retain an all-trans conformation. Figure 10c depicts the sensing mechanism of the piezoelectric polymer-based tactile sensor. In the case of PVDF, polarization of molecules decreases as a result of applied pressure because the magnitude of polarization is proportional to the distance (r) between hydrogen and fluorine atoms. Positive voltage output occurs when the pressure is released, because the restoration of the film increases the distance between atoms. Other piezoelectric polymers containing atoms giving rise to different dipole arrangements also generate voltages in a similar way.
Although there are commercially available PVDF and P(VDF-TrFE) films for pressure sensors and energy harvesting, owing to their relatively high sensitivity [217] their use is limited to sensing dynamic forces and pressures only. In other words, piezoelectric polymer materials are inappropriate for static measurements. This is because the electrical charge generated in a piezoelectric material under static stress decays over time, depending on the dielectric constants, internal film resistance and conductivities of the connected materials involved [218–225]. Therefore, careful consideration regarding application specifications is necessary when choosing piezoelectric materials for sensors.
Tensile sensors for monitoring various kinds of motions have been researched. Razian et al. developed an in-shoe triaxial pressure transducer with a piezoelectric polymer, for the diagnosis of foot disorders [226]. P(VDF-TrFE)-based sensors can simultaneously measure the vertical and horizontal shear forces under the foot with average sensitivities of 20 pC N–1 and 2.2 pC N–1, respectively. Tanaka et al. [227] developed a haptic finger sensor to evaluate skin conditions using PVDF film. The variance of the signal and dispersion of power spectrum density in frequency domain was translated to give an index of skin roughness and hardness, respectively. As a result, relatively reliable agreement was observed between analysed data and clinical assessment from people with various skin disorders. Tanaka et al. [228] also developed a piezoelectric polymer-based palpation sensor for prostatic cancer and hypertrophy detection. To measure the stiffness of the prostate gland, a PVDF film-based sensor was inserted into the examinee's rectum. The results show that data obtained from the sensor were in good correlation with the doctor's conventional examination. Kim et al. [200] explored a piezoelectric polymer-based sensitized microgripper for micro-assembly and micro-manipulation. The microgripper, incorporating PVDF, presented reliable force feedback with high sensitivity and high signal-to-noise ratio at 1 Hz linear load with a resolution of 39.5 mN V–1. The PVDF-based microgripper sensor can be used to measure gripping forces of the order of micronewtons.
Piezoelectric polymer materials can be used not only for stress sensing, but also for other types of sensor applications, such as heat sensing, since some piezoelectric materials have pyroelectric properties. Pyroelectric materials have temperature-dependent dipole moments. As a result, these materials generate electrical charges on their surfaces in response to thermal energy [229,230]. Lee et al. developed a flexible piezoelectric and pyroelectric hybrid device using P(VDF-TrFE) [231]. This device contained a composite of polydimethyl-siloxane (PDMS) with carbon nanotubes (CNTs) as a stretchable electrode, and grapheme nanosheets as a temperature gradient generator. In use, the magnitude of the applied force and temperature gradient could be found simultaneously from the magnitude of the output voltage of the hybrid device.
In summary, piezoelectric polymer materials are interesting candidates for mechanical force and temperature gradient sensing. The induced strain from applied force or external heat can be measured by analysing a voltage or charge across the piezoelectric material. Piezoelectric polymers, especially PVDF and its copolymers, are widely employed in commercial applications due to their wide bandwidth, fast electromechanical response, high voltage sensitivity, low acoustic and mechanical impedance, high strength and high impact resistance. However, some limitations, such as charge dissipation, should be considered when choosing suitable materials for sensing applications.
4. Concluding remarks and future prospects
We have presented a brief overview of EAPs for sensing by focusing on the materials used and the relevant sensing mechanisms. The main sensing properties of various EAPs discussed are summarized in tables 1–3, which should help evaluate different variants as materials for sensory applications.
Table 2.
Materials selection guide for electronic EAPs.
type of EAPs | typical stimuli sensed | typical sensing range | typical working frequency/response time | typical signal readout | notes | references |
---|---|---|---|---|---|---|
dielectric elastomers | strain | strain: 300% | <50 Hz (potential higher sensing frequency than the current value) | 0–300 nF | used mainly for sensing mechanical strain, commercially established |
[134,147,233] |
liquid-crystal elastomers | compression | compressive strain >0.6 | ∼10 Hz | 10–40 mV | only a few studies have been reported so far | [172,180,181] |
bending | displacement of a few millimetre | 0.3–9 Hz | ∼50 nC m−1 | |||
piezoelectric polymers | pressure | <150 MPa | 0.001–109 Hz | ∼0.013 V N−1 | signal attenuates when measuring static force | [234] |
heat | 20–180°C | n.a. | ∼ 8 V/°K | n.a. |
Table 1.
Materials selection guide for ionic EAPs.
type of EAPs | typical stimuli sensed | typical sensing range | typical working frequency or response time | typical signal readout | notes | references |
---|---|---|---|---|---|---|
conducting polymers | force or displacement | up to few per cent strain | 0.1–100 Hz | —1 MPa stress produces 20–60 µV and 2000–6000 C m−3 —1000 C m−3 for 1% strain —>100 mV change in conductance —a few microampere —0.180 mV (3% strain) |
potential drift due to environment changes. CPs are used in both free-standing and trilayer configurations. | [30–32,36,51,56] |
gas molecules | <10 ppm | few seconds | ||||
ionic polymer–metal composites | displacement (strain) | up to 10% in strain | microseconds to seconds or up to hundreds of hertz | approximately 100 mV (200 N load) | potential drift due to environment changes | [84,232] |
carbon nanotubes | force | up to several hundred MPa | milliseconds | ∼75 nA (200 MPa load) | generally displays sharp current peaks | [105,109] |
gas molecules | ∼0.01 ppm | 2–10 s | few microsecond (NH3 detection) | generally displays high sensitivity |
Similar to other advanced technologies, EAPs will face some challenges before wide-scale deployment becomes a possibility:
(i) EAPs have the potential to be manufactured in various forms ranging from fibres, to films, to fabrics and strips [1,10]. EAPs are also being developed in the field of MEM technology [14,15]. For sensory applications, the continued implantation of sensor devices based on EAPs can improve ease of manufacture, mechanical flexibility and quality of signal output. Nonetheless, sensors for practical use must reach operational parameters reliably. Standards for both research purposes and mass-production are yet to be reached: this is probably due to the diversity of EAPs. There are many factors to consider, such as geometries, chemical compositions of materials, fabrication procedures and electromechanical coupling properties.
(ii) Maintaining the sensor specificity with appropriate packaging methods and materials is a major issue (particularly for ionic EAPs, as many of them need to work in moist conditions) [10]. Potential approaches for packaging or sealing the EAPs to prevent or retard degeneration are still in development [1,235], and have yet to meet industrial requirements.
(iii) Methods for the conveyance of sensory information from sensors to other recipients has yet to be developed, particularly for biomedical applications [236,237]. Recent efforts [238–240] have been made to develop EAPs that are compatible with neuron interfaces. There is hope that the neuron system can be used for communicating sensory information from EAP-based sensors.
Nonetheless, EAPs are attractive materials that will play a significant role in sensor-related technologies in the near future. There can be no doubt that inspiring stories about research and commercialization related to EAP sensors will continue.
Authors' contributions
T.W., M.F., Y.S.C., I.T.L., J.E.M. and N.M.T. wrote the manuscript with input from all the authors. S.K.S., J.D.W.M., S.K.N. and T.W. conceived the initial goal of the review, with the final goal determined by all the authors. S.K.S., J.D.W.M. and S.K.N. supervised the review construction. M.F. and T.W. reviewed the ionic EAPs part; Y.S.C., I.T.L., J.E.M. and N.M.T. contributed the electronic EAPs part. All authors gave final approval for publication.
Competing interests
We have no competing interests.
Funding
S.K.S., T.W., I.T.L., J.E.M. and N.M.T. acknowledge funding through the European Research Council (ERC) grant EMATTER (grant no.: 280078). J.D.W.M. and M.F. acknowledge funding through a Discovery Grant from the Natural Sciences and Engineering Research Council of Canada (NSERC). S.K.N. and Y.S.C. acknowledge funding through an ERC Starting Grant (grant no.: ERC-2014-STG-639526, NANOGEN). T.W. acknowledges scholarship funding from the China Scholarship Council (CSC) and support from the Engineering and Physical Sciences Research Council of the UK (EPSRC) Centre for Doctoral Training in Sensor Technologies and Applications (grant no.: EP/L015889/1). Y.S.C. acknowledges studentship funding from the Cambridge Commonwealth, European & International Trust.
References
- 1.Bar-Cohen Y. (ed.). 2004. Electroactive polymer (EAP) actuators as artificial muscles. Reality, potential, and challenges. Washington, DC: SPIE PRESS. [Google Scholar]
- 2.Carpi F, Smela E (eds). 2009. Biomedical applications of electroactive polymer actuators. Chippenham, UK: John Wiley & Sons, Ltd. [Google Scholar]
- 3.Bharti V, Bar-Cohen Y, Cheng Z-Y, Zhang Q, Madden J (eds). 2006. Electroresponsive polymers and their applications. Boston, MA: MRS. [Google Scholar]
- 4.Roentgen WC. 1880. About the changes in shape and volume of dielectrics caused by electricity. Annu. Phys. Chem. 11, 771–786. ( 10.1002/andp.18802471304) [DOI] [Google Scholar]
- 5.Sacerdote MP. 1899. On the electrical deformation of isotropic dielectric solids. J. Phys. 3 Series, 282–285. [Google Scholar]
- 6.Brochu P, Pei Q. 2010. Advances in dielectric elastomers for actuators and artificial muscles. Macromol. Rapid Commun. 31, 10–36. ( 10.1002/marc.200900425) [DOI] [PubMed] [Google Scholar]
- 7.Rivera RAI, Sanches JMA, Galloway KC, Katzenberg HS, Kothari R, Arthur JV. 2010. Dielectric elastomer fiber transducers. Patent no. US 7834527 B2.
- 8.Bar-Cohen Y. 2004. EAP as artificial muscles: progress and challenges. In Proc. SPIE 5385, Smart structures and materials 2004: electroactive polymer actuators and devices (EAPAD), 27 July, 10. San Diego, CA: SPIE. ( 10.1117/12.538698) [DOI] [Google Scholar]
- 9.Carpi F, De Rossi D. 2005. Electroactive polymer-based devices for e-textiles in biomedicine. IEEE Trans. Inf. Technol. Biomed. 9, 295–318. ( 10.1109/TITB.2005.854514) [DOI] [PubMed] [Google Scholar]
- 10.Biddiss E, Chau T. 2006. Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite. Med. Eng. Phys. 28, 568–578. ( 10.1016/j.medengphy.2005.09.009) [DOI] [PubMed] [Google Scholar]
- 11.Jean-Mistral C, Basrour S, Chaillout J-J. 2010. Comparison of electroactive polymers for energy scavenging applications. Smart Mater. Struct. 19, 085012 ( 10.1088/0964-1726/19/8/085012) [DOI] [Google Scholar]
- 12.Keshavarzi A, Shahinpoor M, Kim KJ, Lantz JW. 1999. Blood pressure, pulse rate, and rhythm measurement using ionic polymer-metal composite sensors. In Smart structures and materials (ed. Bar-Cohen Y.), pp. 369–376. Newport Beach, CA: SPIE. [Google Scholar]
- 13.Riley PJ, Wallace GG. 1991. Intelligent chemical systems based on conductive electroactive polymers. J. Intell. Mater. Syst. Struct. 2, 228–238. ( 10.1177/1045389X9100200207) [DOI] [Google Scholar]
- 14.Shahinpoor M. 2001. Potential applications of electroactive polymer sensors and actuators in MEMS technologies. In Smart materials (eds AR Wilson, H Asanuma), pp. 203–214. SPIE. ( 10.1117/12.424408) [DOI]
- 15.Kornbluh RD, Pelrine R, Prahlad H, Heydt R. 2004. Electroactive polymers: an emerging technology for MEMS. In MEMS/MOEMS components and their applications (eds Janson SW, Henning AK), pp. 13–27. San Jose, CA: SPIE. [Google Scholar]
- 16.Baughman RH. 1996. Conducting polymer artificial muscles. Synth. Met. 78, 339–353. ( 10.1016/0379-6779(96)80158-5) [DOI] [Google Scholar]
- 17.Otero TF, Lopez-Cascales J, Vazquez G, Cortés MT, Borgmann H. 2004. Artificial muscles with tactile sensing. Adv. Mater. 15, 348–351. [Google Scholar]
- 18.Shahinpoor M, Bar-Cohen Y, Simpson JO, Smith J. 1998. Ionic polymer–metal composites (IPMCs) as biomimetic sensors, actuators and artificial muscles—a review. Smart Mater. Struct. 7, R15–R30. ( 10.1088/0964-1726/7/6/001) [DOI] [Google Scholar]
- 19.De Luca V, Digiamberardino P, Di Pasquale G, Graziani S, Pollicino A, Umana E, Xibilia MG. 2013. Ionic electroactive polymer metal composites: fabricating, modeling, and applications of postsilicon smart devices. J. Polym. Sci. Part B Polym. Phys. 51, 699–734. ( 10.1002/polb.23255) [DOI] [Google Scholar]
- 20.Pelrine R, Kornbluh R, Pei Q, Joseph J. 2000. High-speed electrically actuated elastomers with strain greater than 100%. Science 287, 836–839. ( 10.1126/science.287.5454.836) [DOI] [PubMed] [Google Scholar]
- 21.Carpi F, et al. 2015. Standards for dielectric elastomer transducers. Smart Mater. Struct. 24, 105025 ( 10.1088/0964-1726/24/10/105025) [DOI] [Google Scholar]
- 22.Zhang QM, Bharti VXZ. 1998. Giant electrostriction and relaxor ferroelectric behavior in electron-irradiated Poly(vinylidene fluoride-trifluoroethylene) copolymer. Science 280, 2101–2104. ( 10.1126/science.280.5372.2101) [DOI] [PubMed] [Google Scholar]
- 23.Lehmann W, Skupin H, Tolksdorf C, Gebhard E, Zentel R, Krüger P, Lösche M, Kremer F. 2001. Giant lateral electrostriction in ferroelectric liquid-crystalline elastomers. Nature 410, 447–450. ( 10.1038/35068522) [DOI] [PubMed] [Google Scholar]
- 24.Ji Y, Marshall JE, Terentjev EM. 2012. Nanoparticle-liquid crystalline elastomer composites. Polymers 4, 316–340. ( 10.3390/polym4010316) [DOI] [Google Scholar]
- 25.Nalwa HS (ed.).. 1995. Ferroelectric polymers: chemistry, physics, and applications. New York, NY: Marcel Dekker, Inc. [Google Scholar]
- 26.Baughman RH, et al. 1999. Carbon nanotube actuators. Science 284, 1340–1344. ( 10.1126/science.284.5418.1340) [DOI] [PubMed] [Google Scholar]
- 27.Carpi F. 2010. Electromechanically active polymers. Polym. Int. 59, 277–278. ( 10.1002/pi.2790) [DOI] [Google Scholar]
- 28.Zhang X, Li W, Wen W, Wu Y, Wallace G. 2009. Development of electrorheological chip and conducting polymer-based sensor. Front. Mech. Eng. China 4, 393–396. ( 10.1007/s11465-009-0043-8) [DOI] [Google Scholar]
- 29.Takashima W, Uesugi T, Fukui M, Kaneko M, Kaneto K. 1997. Mechanochemoelectrical effect of polyaniline film. Synth. Met. 85, 1395–1396. ( 10.1016/S0379-6779(97)80289-5) [DOI] [Google Scholar]
- 30.Shoa T, Madden JDW, Mirfakhrai T, Alici G, Spinks GM, Wallace GG. 2010. Electromechanical coupling in polypyrrole sensors and actuators. Sensors Actuators, A Phys. 161, 127–133. ( 10.1016/j.sna.2010.04.024) [DOI] [Google Scholar]
- 31.Wu Y, Alici G, Madden JDW, Spinks GM, Wallace GG. 2007. Soft mechanical sensors through reverse actuation in polypyrrole. Adv. Funct. Mater. 17, 3216–3222. ( 10.1002/adfm.200700060) [DOI] [Google Scholar]
- 32.Madden JDW. 2000. Conducting polymer actuators. PhD thesis, Massachusetts Institute of Technology, USA.
- 33.Stoppa M, Chiolerio A. 2014. Wearable electronics and smart textiles: a critical review. Sensors (Switzerland) 14, 11 957–11 992. ( 10.3390/s140711957) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Scilingo EP, Lorussi F, Mazzoldi A, De Rossi D. 2003. Strain-sensing fabrics for wearable kinaesthetic-like systems. IEEE Sens. J. 3, 460–467. ( 10.1109/JSEN.2003.815771) [DOI] [Google Scholar]
- 35.Munro BJ, Campbell TE, Wallace GG, Steele JR. 2008. The intelligent knee sleeve: a wearable biofeedback device. Sensors Actuators B Chem. 131, 541–547. ( 10.1016/j.snb.2007.12.041) [DOI] [Google Scholar]
- 36.Carquigny S, Sanchez J-B, Berger F, Lakard B, Lallemand F. 2009. Ammonia gas sensor based on electrosynthesized polypyrrole films. Talanta 78, 199–206. ( 10.1016/j.talanta.2008.10.056) [DOI] [PubMed] [Google Scholar]
- 37.Hanawa T, Kuwabata S, Hashimoto H, Yoneyama H. 1989. Gas sensitivities of electropolymerized polythiophene films. Synth. Met. 30, 173–181. ( 10.1016/0379-6779(89)90787-X) [DOI] [Google Scholar]
- 38.Ratcliffe NM. 1990. Polypyrrole-based sensor for hydrazine and ammonia. Anal. Chim. Acta 239, 257–262. ( 10.1016/S0003-2670(00)83859-3) [DOI] [Google Scholar]
- 39.Al-Mashat L, Tran HD, Wlodarski W, Kaner RB, Kalantar-zadeh K. 2008. Polypyrrole nanofiber surface acoustic wave gas sensors. Sensors Actuators B Chem. 134, 826–831. ( 10.1016/j.snb.2008.06.030) [DOI] [Google Scholar]
- 40.Zhao Y, Liu B, Pan L, Yu G. 2013. 3D nanostructured conductive polymer hydrogels for high-performance electrochemical devices. Energy Environ. Sci. 6, 2856 ( 10.1039/c3ee40997j) [DOI] [Google Scholar]
- 41.Roget A, Livache T, Billon M. 2001. Reversible oligonucleotide immobilisation based on biotinylated polypyrrole film. Anal. Chim. Acta 449, 45–50. ( 10.1016/S0003-2670(01)01339-3) [DOI] [Google Scholar]
- 42.Billon M, Livache T, Guillerez S. 2004. Biotin/avidin system for the generation of fully renewable DNA sensor based on biotinylated polypyrrole film. Anal. Chim. Acta 515, 271–277. ( 10.1016/j.aca.2004.03.072) [DOI] [Google Scholar]
- 43.Malinauskas A. 2006. Electrochemical sensors based on conducting polymer—polypyrrole. Electrochem. Commun. 51, 6025–6037. ( 10.1016/j.electacta.2005.11.052) [DOI] [Google Scholar]
- 44.Yamaura M, Hagiwara T, Iwata K. 1988. Enhancement of electrical conductivity of Polypyrrole film by stretching: counter ion effect. Synth. Met. 26, 209–224. ( 10.1016/0379-6779(88)90238-X) [DOI] [Google Scholar]
- 45.Smela E. 1999. Microfabrication of PPy microactuators and other conjugated polymer devices. J. Micromech. Microeng. 9, 1–18. ( 10.1088/0960-1317/9/1/001) [DOI] [Google Scholar]
- 46.Wang X, Smela E. 2009. Color and volume change in PPy(DBS). J. Phys. Chem. C 113, 359–368. ( 10.1021/jp802937v) [DOI] [Google Scholar]
- 47.Takashima W, Hayasi K, Kaneto K. 2007. Force detection with Donnan equilibrium in polypyrrole film. Electrochem. commun. 9, 2056–2061. ( 10.1016/j.elecom.2007.05.019) [DOI] [Google Scholar]
- 48.Festin N, Maziz A, Plesse C, Teyssié D, Chevrot C, Vidal F. 2013. Robust solid polymer electrolyte for conducting IPN actuators. Smart Mater. Struct. 22, 104005 ( 10.1088/0964-1726/22/10/104005) [DOI] [Google Scholar]
- 49.Giffney T, Xie M, Sartelet M, Aw KC. 2015. Vapor phase polymerization of PEDOT on silicone rubber as flexible large strain sensor. AIMS Mater. Sci. 2, 414–424. ( 10.3934/matersci.2015.4.414) [DOI] [Google Scholar]
- 50.Bhattacharyya D, Howden RM, Borrelli DC, Gleason KK. 2012. Vapor phase oxidative synthesis of conjugated polymers and applications. J. Polym. Sci. Part B Polym. Phys. 50, 1329–1351. ( 10.1002/polb.23138) [DOI] [Google Scholar]
- 51.Festin N, Plesse C, Pirim P, Chevrot C, Vidal F. 2014. Electro-active interpenetrating polymer networks actuators and strain sensors: fabrication, position control and sensing properties. Sensors Actuators B Chem. 193, 82–88. ( 10.1016/j.snb.2013.11.050) [DOI] [Google Scholar]
- 52.Otero TF, Cortés MT. 2003. A sensing muscle. Sensors Actuators B Chem. 96, 152–156. ( 10.1016/S0925-4005(03)00518-5) [DOI] [Google Scholar]
- 53.Otero TF, Cortés MT. 2003. Artificial muscles with tactile sensitivity. Adv. Mater. 15, 279–282. ( 10.1002/adma.200390066) [DOI] [Google Scholar]
- 54.Chen Y, Li Y, Wang H, Yang M. 2007. Gas sensitivity of a composite of multi-walled carbon nanotubes and polypyrrole prepared by vapor phase polymerization. Carbon N. Y. 45, 357–363. ( 10.1016/j.carbon.2006.09.011) [DOI] [Google Scholar]
- 55.Yang M-Z, Dai C-L, Lu D-H. 2010. Polypyrrole porous micro humidity sensor integrated with a ring oscillator circuit on chip. Sensors 10, 10 095–10 104. ( 10.3390/s101110095) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.John S, Alici G, Spinks G, Madden JDW, Wallace G. 2008. Sensor response of polypyrrole trilayer benders as a function of geometry. In Electroactive polymer actuators and devices (ed. Bar-Cohen Y.), pp. 692721-1–692721-9. San Diego, CA: SPIE. [Google Scholar]
- 57.Lu W, Nguyen TA, Wallace GG. 1998. Protein detection using conducting polymer microarrays. Electroanalysis 10, 1101–1107. ( 10.1002/(SICI)1521-4109(199811)10:16%3C1101::AID-ELAN1101%3E3.0.CO;2-6) [DOI] [Google Scholar]
- 58.Alici G, Spinks GM, Madden JD, Wu Y, Wallace GG. 2008. Response characterization of electroactive polymers as mechanical sensors. IEEE/ASME Trans. Mechatron. 13, 187–196. ( 10.1109/TMECH.2008.918531) [DOI] [Google Scholar]
- 59.John SW, Alici G, Spinks GM, Madden JD, Wallace GG. 2009. Towards fully optimized conducting polymer bending sensors: the effect of geometry. Smart Mater. Struct. 18, 1–8. ( 10.1088/0964-1726/18/8/085007) [DOI] [Google Scholar]
- 60.Alici G, Huynh NN. 2007. Performance quantification of conducting polymer actuators for real applications: a microgripping system. IEEE/ASME Trans. Mechatron. 12, 73–84. ( 10.1109/TMECH.2006.886256) [DOI] [Google Scholar]
- 61.Wu Y, Alici G, Spinks GM, Wallace GG. 2006. Fast trilayer polypyrrole bending actuators for high speed applications. Synth. Met. 156, 1017–1022. ( 10.1016/j.synthmet.2006.06.022) [DOI] [Google Scholar]
- 62.Maziz A, Plesse C, Soyer C, Chevrot C, Teyssié D, Cattan E, Vidal F. 2014. Demonstrating kHz frequency actuation for conducting polymer microactuators. Adv. Funct. Mater. 24, 4851–4859. ( 10.1002/adfm.201400373) [DOI] [Google Scholar]
- 63.Festin N, Plesse C, Chevrot C, Teyssié D, Josselin L, Pirim P, Vidal F. 2011. Actuation and sensing properties of electroactive polymer whiskers. Procedia Comput. Sci. 7, S4–S7. ( 10.1016/j.procs.2012.01.093) [DOI] [Google Scholar]
- 64.Vidal F, et al. 2010. Poly(3,4-ethylenedioxythiophene)-containing semi-interpenetrating polymer networks: a versatile concept for the design of optical or mechanical electroactive devices. Polym. Int. 59, 313–320. ( 10.1002/pi.2772) [DOI] [Google Scholar]
- 65.Khaldi A, Plesse C, Vidal F, Smoukov SK. 2015. Smarter actuator design with complementary and synergetic functions. Adv. Mater. 27, 4418–4422. ( 10.1002/adma.201500209) [DOI] [PubMed] [Google Scholar]
- 66.Price AD, Naguib HE, Amara FB. 2015. Electroactive polymer actuators for active optical components. J. Intell. Mater. Syst. Struct. 26, 2556–2564. ( 10.1177/1045389X14557505) [DOI] [Google Scholar]
- 67.Zheng W, Razal JM, Whitten PG, Ovalle-Robles R, Wallace GG, Baughman RH, Spinks GM. 2011. Artificial muscles based on polypyrrole/carbon nanotube laminates. Adv. Mater. 23, 2966–2970. ( 10.1002/adma.201100512) [DOI] [PubMed] [Google Scholar]
- 68.Goujon LJ, Khaldi A, Maziz A, Plesse C, Nguyen GTM, Aubert PH, Vidal F, Chevrot C, Teyssié D. 2011. Flexible solid polymer electrolytes based on nitrile butadiene rubber/poly(ethylene oxide) interpenetrating polymer networks containing either LiTFSI or EMITFSI. Macromolecules 44, 9683–9691. ( 10.1021/ma201662h) [DOI] [Google Scholar]
- 69.Bahramzadeh Y, Shahinpoor M. 2014. A review of ionic polymeric soft actuators and sensors. Soft Robot. 1, 38–52. ( 10.1089/soro.2013.0006) [DOI] [Google Scholar]
- 70.Kruusamäe K, Punning A, Aabloo A, Asaka K. 2015. Self-sensing ionic polymer actuators: a review. Actuators 4, 17–38. ( 10.3390/act4010017) [DOI] [Google Scholar]
- 71.Vunder V, Punning A, Aabloo A. 2015. Long-term behavior of ionic electroactive polymer actuators in variable humidity conditions. In Proc. SPIE 9430, Electroactive Polymer Actuators and Devices (EAPAD) (ed. Y Bar-Cohen), p. 94300R. SPIE ( 10.1117/12.2084155) [DOI]
- 72.Shahinpoor M, Kim KJ. 2001. Ionic polymer–metal composites: I. Fundamental. Smart Mater. Struct. 10, 819–833. ( 10.1088/0964-1726/10/4/327) [DOI] [Google Scholar]
- 73.Nemat-Nasser S. 2002. Micromechanics of actuation of ionic polymer-metal composites. J. Appl. Phys. 92, 2899–2915. ( 10.1063/1.1495888) [DOI] [Google Scholar]
- 74.Grodzinsky AJ, Melcher JR. 1976. Electromechanical transduction with charged polyelectrolyte membranes. IEEE Trans. Biomed. Eng. BME-23, 421–433. ( 10.1109/TBME.1976.324600) [DOI] [PubMed] [Google Scholar]
- 75.Sadeghipour K, Salomon R, Neogi S. 1992. Development of a novel electrochemically active membrane and ‘smart’ material based vibration sensor/damper. Smart Mater. Struct. 1, 172–179. ( 10.1088/0964-1726/1/2/012) [DOI] [Google Scholar]
- 76.Mojarrad M, Shahinpoor M.. 1997. Ion-exchange-metal composite sensor films. Proc. SPIE 3042, 52–60. ( 10.1117/12.275724) [DOI] [Google Scholar]
- 77.Ferrara L, Shahinpoor M, Kim KJ, Schreyer HB, Keshavarzi A, Benzel E, Lantz JW. 1999. Use of ionic polymer-metal composites (IPMCs) as a pressure transducer in the human spine. Smart Struct. Mater. 1999 Electroact. Polym. Actuators Devices 3669, 394–401. ( 10.1117/12.349704) [DOI] [Google Scholar]
- 78.Tiwari R, Garcia E. 2011. The state of understanding of ionic polymer metal composite architecture: a review. Smart Mater. Struct. 20, 083001 ( 10.1088/0964-1726/20/8/083001) [DOI] [Google Scholar]
- 79.Khaldi A, Elliott JA, Smoukov SK. 2014. Electro-mechanical actuator with muscle memory. J. Mater. Chem. C 2, 8029–8034. ( 10.1039/C4TC00904E) [DOI] [Google Scholar]
- 80.Bennett MD, Leo DJ, Wilkes GL, Beyer FL, Pechar TW. 2006. A model of charge transport and electromechanical transduction in ionic liquid-swollen Nafion membranes. Polymer (Guildf). 47, 6782–6796. ( 10.1016/j.polymer.2006.07.061) [DOI] [Google Scholar]
- 81.Eisenberg A, Kim JS. 1998. Introduction to ionomers. New York, NY: Wiley. [Google Scholar]
- 82.Tant MR, Mauritz KA, Wilkes GL. 1997. Ionomers: synthesis, structure, properties and applications. New York, NY: Springer Netherlands. [Google Scholar]
- 83.Zhang Y, Ma C, Dai L. 2007. Electrode preparation and electro-deformation of ionic polymer-metal composite (IPMC). In Proc. of the 2nd IEEE Int. Conf. on Nano/Micro Engineered and Molecular Systems, IEEE NEMS 2007, pp. 68–71. Bangkok, Thailand: IEEE ( 10.1109/NEMS.2007.352151) [DOI]
- 84.Bhandari B, Lee G-Y, Ahn S-H. 2012. A review on IPMC material as actuators and sensors: fabrications, characteristics and applications. Int. J. Precis. Eng. Manuf. 13, 141–163. ( 10.1007/s12541-012-0020-8) [DOI] [Google Scholar]
- 85.Oguro K. Osaka National Research Institute. Preparation Procedure: Ion-Exchange Polymer Metal Composites (IPMC) Membranes.http://ndeaa.jpl.nasa.gov/nasa-nde/lommas/eap/IPMC_PrepProcedure.htm. (accessed 31 May 2016).
- 86.Chung RJ, Chin TS, Chen LC, Hsieh MF. 2007. Preparation of gradually componential metal electrode on solution-casted Nafion membrane. Biomol. Eng. 24, 434–437. ( 10.1016/j.bioeng.2007.07.003) [DOI] [PubMed] [Google Scholar]
- 87.Johnson T, Amirouche F. 2008. Multiphysics modeling of an IPMC microfluidic control device. Microsyst. Technol. 14, 871–879. ( 10.1007/s00542-008-0603-6) [DOI] [Google Scholar]
- 88.Bonomo C, Negro CD, Fortuna L, Graziani S. 2003. Characterization of IPMC strip sensorial properties: preliminary results. In Proc. 2003 Int. Symp. Circuits Syst. 2003. ISCAS ‘03, vol. 4, IV-816–IV-819. Bangkok, Thailand: IEEE ( 10.1109/ISCAS.2003.1206338) [DOI]
- 89.Bar-cohen Y, Bao X, Sherrit S, Lih S. 2002. Characterization of the electromechanical properties of ionomeric polymer-metal composite (IPMC). In Proc. of the SPIE Smart Structures and Materials Symp., EAPAD Conf. San Diego, CA: SPIE. ( 10.1117/12.475173) [DOI]
- 90.Pugal D, Jung K, Aabloo A, Kim KJ.2010. Ionic polymer-metal composite mechanoelectrical transduction: review and perspectives. Polym. Int. 59, 279–289. (doi:10.1002/pi.2759)
- 91.Nemat-Nasser S, Li JY. 2000. Electromechanical response of ionic polymer-metal composites. J. Appl. Phys. 87, 3321 ( 10.1063/1.372343) [DOI] [Google Scholar]
- 92.Park I-S, Jung K, Kim D, Kim S-M, Kim KJ. 2008. Physical principles of ionic polymer–metal composites as electroactive actuators and sensors. MRS Bull. 33, 190–195. ( 10.1557/mrs2008.44) [DOI] [Google Scholar]
- 93.Farinholt K, Leo DJ. 2004. Modeling of electromechanical charge sensing in ionic polymer transducers. Mech. Mater. 36, 421–433. ( 10.1016/S0167-6636(03)00069-3) [DOI] [Google Scholar]
- 94.Punning A, Kruusmaa M, Aabloo A. 2007. Surface resistance experiments with IPMC sensors and actuators. Sensors Actuators A Phys. 133, 200–209. ( 10.1016/j.sna.2006.03.010) [DOI] [Google Scholar]
- 95.Shen Q, Kim KJ, Wang T. 2014. Electrode of ionic polymer-metal composite sensors: modeling and experimental investigation. J. Appl. Phys. 115, 194902 ( 10.1063/1.4876255) [DOI] [Google Scholar]
- 96.Bahramzadeh Y, Shahinpoor M. 2011. Dynamic curvature sensing employing ionic-polymer–metal composite sensors. Smart Mater. Struct. 20, 094011 ( 10.1088/0964-1726/20/9/094011) [DOI] [Google Scholar]
- 97.Abdulsadda AT, Xiaobo T. 2011. Underwater source localization using an IPMC-based artificial lateral line. In Robot. Autom. (ICRA), 2011 IEEE Int. Conf., pp. 2719–2724. Shanghai, China: IEEE ( 10.1109/icra.2011.5980545) [DOI]
- 98.Bonomo C, Fortuna L, Giannone P, Graziani S, Strazzeri S. 2008. A resonant force sensor based on ionic polymer metal composites. Smart Mater. Struct. 17, 13 ( 10.1088/0964-1726/17/01/015014) [DOI] [Google Scholar]
- 99.Andò B, Bonomo C, Fortuna L, Giannone P, Graziani S, Sparti L, Strazzeri S. 2008. A bio-inspired device to detect equilibrium variations using IPMCs and ferrofluids. Sensors Actuators A Phys. 144, 242–250. ( 10.1016/j.sna.2008.02.005) [DOI] [Google Scholar]
- 100.Nemat-Nasser S, Zamani S, Tor Y. 2006. Effect of solvents on the chemical and physical properties of ionic polymer-metal composites. J. Appl. Phys. 99, 1–17. ( 10.1063/1.2194127) [DOI] [Google Scholar]
- 101.Nemat-Nasser S, Zamani S. 2006. Modeling of electrochemomechanical response of ionic polymer-metal composites with various solvents. J. Appl. Phys. 100, 1–18. ( 10.1063/1.2221505) [DOI] [Google Scholar]
- 102.Shahinpoor M, Kim KJ, Leo DJ. 2003. Ionic polymer-metal composites as multifunctional materials. Polym. Compos. 24, 24–33. ( 10.1002/pc.10002) [DOI] [Google Scholar]
- 103.Bonomo C, Brunetto P, Fortuna L, Giannone P, Graziani S, Strazzeri S. 2008. A tactile sensor for biomedical applications based on IPMCs. IEEE Sens. J. 8, 1486–1493. ( 10.1109/JSEN.2008.920723) [DOI] [Google Scholar]
- 104.Park K, Lee B, Kim HM, Choi KS, Hwang G, Byun GS, Lee HK. 2013. IPMC based biosensor for the detection of biceps brachii muscle movements. Int. J. Electrochem. Sci. 8, 4098–4109. [Google Scholar]
- 105.Wang Y, Yeow JTW. 2009. A review of carbon nanotubes-based gas sensors. J. Sensors 2009, 1–24. ( 10.1155/2009/493904) [DOI] [Google Scholar]
- 106.Mirfakhrai T, Oh JY, Kozlov M, Fang SL, Zhang M, Baughman RH, Madden JD. 2008. Carbon nanotube yarns as high load actuators and sensors. Adv. Sci. Technol. 61, 65–74. ( 10.4028/www.scientific.net/AST.61.65) [DOI] [Google Scholar]
- 107.Anas NS. 2011. Carbon nanotube as a basic material for sensors: a review. In Nanoscience, Engineering and Technology (ICONSET), pp. 212–218. Chennai, India: IEEE ( 10.1109/ICONSET.2011.6167957) [DOI]
- 108.Salehi-khojin A, Khalili-araghi F, Kuroda MA, Lin KKY, Leburton P, Masel RI. 2011. On the sensing mechanism in carbon nanotube chemiresistors. ACS Nano 5, 153–158. [DOI] [PubMed] [Google Scholar]
- 109.Rius FX, Riu J. 2010. Electrochemical sensing based on carbon nanotubes. Trends Anal. Chem. 29, 939–953. ( 10.1016/j.trac.2010.06.006) [DOI] [Google Scholar]
- 110.Jacobs CB, Peairs MJ, Venton BJ. 2010. Review: carbon nanotube based electrochemical sensors for biomolecules. Anal. Chim. Acta 662, 105–127. ( 10.1016/j.aca.2010.01.009) [DOI] [PubMed] [Google Scholar]
- 111.Ahammad AJS, Lee J, Rahman A. 2009. Electrochemical sensors based on carbon nanotubes. Sensors 9, 2289–2319. ( 10.3390/s90402289) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 112.Yang N, Chen X, Ren T, Zhang P, Yang D. 2015. Carbon nanotube based biosensors. Sensors Actuators B Chem. 207, 690–715. ( 10.1016/j.snb.2014.10.040) [DOI] [Google Scholar]
- 113.Boero C, Olivo J, De Micheli G, Carrara S. 2012. New approaches for carbon nanotubes-based biosensors and their application to cell culture monitoring. IEEE Trans. Biomed. Circuits Syst. 6, 479–485. ( 10.1109/TBCAS.2012.2220137) [DOI] [PubMed] [Google Scholar]
- 114.Balasubramanian K, Burghard M. 2006. Biosensors based on carbon nanotubes. Anal. Bioanal. Chem. 385, 452–468. ( 10.1007/s00216-006-0314-8) [DOI] [PubMed] [Google Scholar]
- 115.Dragan ES. 2014. Design and applications of interpenetrating polymer network hydrogels: A review. Chem. Eng. J. 243, 572–590. ( 10.1016/j.cej.2014.01.065) [DOI] [Google Scholar]
- 116.Ullah F, Othman MBH, Javed F, Ahmad Z, Akil HM. 2015. Classification, processing and application of hydrogels: a review. Mater. Sci. Eng. C 57, 414–433. ( 10.1016/j.msec.2015.07.053) [DOI] [PubMed] [Google Scholar]
- 117.Kuckling D, Richter A, Arndt KF. 2003. Temperature and pH-dependent swelling behavior of poly(N-isopropylacrylamide) copolymer hydrogels and their use in flow control. Macromol. Mater. Eng. 288, 144–151. ( 10.1002/mame.200390007) [DOI] [Google Scholar]
- 118.Oktar O, Caglar P, Seitz WR. 2005. Chemical modulation of thermosensitive poly(N-isopropylacrylamide) microsphere swelling: a new strategy for chemical sensing. Sensors Actuators, B Chem. 104, 179–185. ( 10.1016/j.snb.2004.04.033) [DOI] [Google Scholar]
- 119.Richter A, Kuckling D, Howitz S, Gehring T, Arndt KF. 2003. Electronically controllable microvalves based on smart hydrogels: magnitudes and potential applications. J. Microelectromechan. Syst. 12, 748–753. ( 10.1109/JMEMS.2003.817898) [DOI] [Google Scholar]
- 120.Liu X, Zhang X, Cong J, Xu J, Chen K. 2003. Demonstration of etched cladding fiber Bragg grating-based sensors with hydrogel coating. Sensors Actuators B Chem. 96, 468–472. ( 10.1016/S0925-4005(03)00605-1) [DOI] [Google Scholar]
- 121.Arndt K-F, Kuckling D, Richter A. 2000. Application of sensitive hydrogels in flow control. Polym. Adv. Technol. 11, 496–505. ( 10.1002/1099-1581) [DOI] [Google Scholar]
- 122.Bashir R. 2004. BioMEMS: State-of-the-art in detection, opportunities and prospects. Adv. Drug Deliv. Rev. 56, 1565–1586. ( 10.1016/j.addr.2004.03.002) [DOI] [PubMed] [Google Scholar]
- 123.Wolfbeis OS. 2006. Hydrogel sensors and actuators. Springer series on chemical sensors and biosensors. Heidelberg: Springer-Verlag. [Google Scholar]
- 124.Carpi F, Rossi D, De Kornbluh R, Pelrine R, Sommer-Larsen P (eds). 2008. Dielectric elastomers as electromechanical transducers: fundamentals, materials, devices, models and applications of an emerging electroactive polymer technology, 1st edn Amsterdam, Netherlands: Elsevier Science S.A. [Google Scholar]
- 125.Son S, Goulbourne NC. 2010. Dynamic response of tubular dielectric elastomer transducers. Int. J. Solids Struct. 47, 2672–2679. ( 10.1016/j.ijsolstr.2010.05.019) [DOI] [Google Scholar]
- 126.Zupan M, Ashby MF, Fleck NA. 2002. Actuator classification and selection—the development of a database. Adv. Eng. Mater. 4, 933–940. ( 10.1002/adem.200290009) [DOI] [Google Scholar]
- 127.Madden JDW, Vandesteeg NA, Anquetil PA, Madden PGA, Takshi A, Pytel RZ, Lafontaine SR, Wieringa PA, Hunter IW. 2004. Artificial muscle technology: physical principles and naval prospects. IEEE J. Ocean. Eng. 29, 706–728. ( 10.1109/JOE.2004.833135) [DOI] [Google Scholar]
- 128.Pelrine R, Kornbluh R, Joseph J, Heydt R, Pei Q, Chiba S. 2000. High-field deformation of elastomeric dielectrics for actuators. Mater. Sci. Eng. C 11, 89–100. ( 10.1016/S0928-4931(00)00128-4) [DOI] [Google Scholar]
- 129.Mirfakhrai T, Madden JDW, Baughman RH. 2007. Polymer artificial muscles. Mater. Today 10, 30–38. ( 10.1016/S1369-7021(07)70048-2) [DOI] [Google Scholar]
- 130.Böse H, Fuß E, Ehrlich J. 2015. Capacitive sensor mats for pressure detection with high sensitivity. In AMA Conf. 2015, pp. 55–60. Nürnberg: AMA Service GmbH ( 10.5162/sensor2015/A2.2) [DOI]
- 131.Koh SJA, Zhao X, Suo Z. 2009. Maximal energy that can be converted by a dielectric elastomer generator. Appl. Phys. Lett. 94, 262902 ( 10.1063/1.3167773) [DOI] [Google Scholar]
- 132.Peirine R, et al. 2001. Dielectric elastomers: generator mode fundamentals and applications. In Electroactive polymer actuators and devices (ed. Bar-Cohen Y.), pp. 148–156. Newport Beach, CA: SPIE. [Google Scholar]
- 133.Chiba S, Waki M, Kornbluh R, Pelrine R. 2008. Innovative power generators for energy harvesting using electroactive polymer artificial muscles. In Electroactive polymer actuators and devices (ed. Y Bar-Cohen), pp. 692 715–692 719. San Diego, CA: SPIE ( 10.1117/12.778345) [DOI] [Google Scholar]
- 134.Xu D, Michel S, McKay T, O'Brien B, Gisby T, Anderson I. 2015. Sensing frequency design for capacitance feedback of dielectric elastomers. Sensors Actuators A Phys. 232, 195–201. ( 10.1016/j.sna.2015.05.010) [DOI] [Google Scholar]
- 135.Xu D, Tairych A, Anderson IA. 2016. Stretch not flex: programmable rubber keyboard. Smart Mater. Struct. 25, 015012 ( 10.1088/0964-1726/25/1/015012) [DOI] [Google Scholar]
- 136.Xu D, Tairych A, Anderson IA. 2016. Where the rubber meets the hand: unlocking the sensing potential of dielectric elastomers. J. Polym. Sci. Part B Polym. Phys. 54, 465–472. ( 10.1002/polb.23926) [DOI] [Google Scholar]
- 137.Aschwanden M, Niederer D, Stemmer A. 2008. Tunable transmission grating based on dielectric elastomer actuators. Electroact. Polym. Actuators Devices 6927, 1–12. ( 10.1117/12.776100) [DOI] [Google Scholar]
- 138.Carpi F, Salaris C, Rossi D. 2007. Folded dielectric elastomer actuators. Smart Mater. Struct. 16, S300–S305. ( 10.1088/0964-1726/16/2/S15) [DOI] [Google Scholar]
- 139.Rosset S, Shea HR. 2013. Flexible and stretchable electrodes for dielectric elastomer actuators. Appl. Phys. A Mater. Sci. Process. 110, 281–307. ( 10.1007/s00339-012-7402-8) [DOI] [Google Scholar]
- 140.O'Brien BM, Calius EP, Inamura T, Xie SQ, Anderson IA. 2010. Dielectric elastomer switches for smart artificial muscles. Appl. Phys. A Mater. Sci. Process. 100, 385–389. ( 10.1007/s00339-010-5857-z) [DOI] [Google Scholar]
- 141.Yuan W, et al. 2008. Fault-tolerant dielectric elastomer actuators using single-walled carbon nanotube electrodes. Adv. Mater. 20, 621–625. ( 10.1002/adma.200701018) [DOI] [Google Scholar]
- 142.Lin S, Yuk H, Zhang T, Parada GA, Koo H, Yu C, Zhao X. 2015. Stretchable hydrogel electronics and devices. Adv. Mater. 1–9. ( 10.1002/adma.201504152) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 143.Bai Y, Jiang Y, Chen B, Chiang Foo C, Zhou Y, Xiang F, Zhou J, Wang H, Suo Z. 2014. Cyclic performance of viscoelastic dielectric elastomers with solid hydrogel electrodes. Appl. Phys. Lett. 104, 2012–2016. ( 10.1063/1.4865200) [DOI] [Google Scholar]
- 144.Zang J, Cao C, Feng Y, Liu J, Zhao X. 2014. Stretchable and high-performance supercapacitors with crumpled graphene papers. Sci. Rep. 4, 6492 ( 10.1038/srep06492) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 145.Lochmatter P, Kovacs G. 2008. Design and characterization of an active hinge segment based on soft dielectric EAPs. Sensors Actuators A Phys. 141, 577–587. ( 10.1016/j.sna.2007.10.029) [DOI] [Google Scholar]
- 146.Fox JW, Goulbourne NC. 2006. A study on the effect of flexible electrodes and passive layers on the performance of dielectric elastomer membranes. In ASME Int. Mechanical Engineering Congress and Exposition, pp. 425–433. Chicago, IL: ASME ( 10.1115/IMECE2006-15888) [DOI]
- 147.Pelrine R, Kornbluh R, Kofod G. 2000. High-strain actuator materials based on dielectric elastomers. Adv. Mater. 12, 1223–1225. ( 10.1002/1521-4095(200008)12:16%3C1223::AID-ADMA1223%3E3.0.CO;2-2) [DOI] [Google Scholar]
- 148.Araromi O, Poulin A, Rosset S, Favre M, Giazzon M, Martin-Olmos C, Liley M, Shea H. 2015. Thin-film dielectric elastomer sensors to measure the contraction force of smooth muscle cells. In Electroactive polymer actuators and devices (EAPAD) (ed. Bar-Cohen Y.), p. 94300Z. San Diego, CA: SPIE; ( 10.1117/12.2083905) [DOI] [Google Scholar]
- 149.Pei Q, Rosenthal M, Stanford S, Prahlad H, Pelrine R. 2004. Multiple-degrees-of-freedom electroelastomer roll actuators. Smart Mater. Struct. 13, N86–N92. ( 10.1088/0964-1726/13/5/N03) [DOI] [Google Scholar]
- 150.Rosenthal M, Bonwit N, Duncheon C, Heim J. 2007. Applications of dielectric elastomer EPAM sensors. In Electroactive polymer actuators and devices (ed. Y Bar-Cohen), pp. 65241F-1–65241F–7. San Diego, CA: SPIE ( 10.1117/12.715084) [DOI] [Google Scholar]
- 151.Gisby TA, Obrien BM, Anderson IA. 2013. Self sensing feedback for dielectric elastomer actuators. Appl. Phys. Lett. 102, 1–4. ( 10.1063/1.4805352) [DOI] [Google Scholar]
- 152.Rosset S, O'Brien BM, Gisby T, Xu D, Shea HR, Anderson IA. 2013. Self-sensing dielectric elastomer actuators in closed-loop operation. Smart Mater. Struct. 22, 104018 ( 10.1088/0964-1726/22/10/104018) [DOI] [Google Scholar]
- 153.Gisby TA, O'Brien BM, Xie SQ, Calius EP, Anderson IA. 2011. Closed loop control of dielectric elastomer actuators. In Electroactive polymer actuators and devices (EAPAD) (ed. Y Bar-Cohen), pp. 1–9. San Diego, CA: SPIE; ( 10.1117/12.880711) [DOI] [Google Scholar]
- 154.Gisby TA, Xie S, Calius EP, Anderson IA. 2009. Integrated sensing and actuation of muscle-like actuators. In Electroactive polymer actuators and devices (EAPAD) (ed. Y Bar-Cohen), pp. 1–12. San Diego, CA: SPIE ( 10.1117/12.815645) [DOI] [Google Scholar]
- 155.Anderson IA, Gisby TA, McKay TG, O'Brien BM, Calius EP. 2012. Multi-functional dielectric elastomer artificial muscles for soft and smart machines. J. Appl. Phys. 112, 1–20. ( 10.1063/1.4740023) [DOI] [Google Scholar]
- 156.Gisby TA, Xie SQ, Calius EP, Anderson IA. 2010. Leakage current as a predictor of failure in dielectric elastomer actuators. In Electroactive polymer actuators and devices (EAPAD) (ed. Y Bar-Cohen), pp. 1–11. Newport Beach, CA: SPIE ( 10.1117/12.847835) [DOI] [Google Scholar]
- 157.Rizzello G, Naso D, York A, Seelecke S. 2015. Self-sensing in dielectric electro-active polymer actuator using linear-in-parameters online estimation. In Mechatronics (ICM), 2015 IEEE Int. Conf., pp. 300–306. Nagoya, Japan: IEEE ( 10.1109/ICMECH.2015.7083992) [DOI]
- 158.Jung K, Kim KJ, Choi HR. 2008. A self-sensing dielectric elastomer actuator. Sensors Actuators A Phys. 143, 343–351. ( 10.1016/j.sna.2007.10.076) [DOI] [Google Scholar]
- 159.Jung K, Kim KJ, Choi HR. 2008. Self-sensing of dielectric elastomer actuator. In Electroactive polymer actuators and devices (EAPAD) (ed. Y Bar-Cohen), pp. 1–10. San Diego, CA: SPIE ( 10.1117/12.776831) [DOI] [Google Scholar]
- 160.Huu Chuc N, Thuy DV, Park J, Kim D, Koo J, Lee Y, Nam J-D, Choi HR. 2008. A dielectric elastomer actuator with self-sensing capability. In Electroactive polymer actuators and devices (EAPAD) (ed. Y Bar-Cohen), pp. 1–8. San Diego, CA: SPIE ( 10.1117/12.777900) [DOI] [Google Scholar]
- 161.Toth LA, Goldenberg AAA. 2002. Control System design for a dielectric elastomer actuator: the sensory subsystem. In Electroactive polymer actuators and devices (EAPAD) (ed. Y Bar-Cohen), pp. 323–334. San Diego, CA: SPIE ( 10.1117/12.475179) [DOI] [Google Scholar]
- 162.Böse H, Fuß E. 2014. 02_Novel dielectric elastomer sensors for compression load detection. In Electroactive polymer actuators and devices (EAPAD) (ed. Y Bar-Cohen), pp. 905614-1–13. San Diego, CA: SPIE ( 10.1117/12.2045133) [DOI] [Google Scholar]
- 163.Kim KWJ, Jung K. 2010. Self-sensing dielectric actuator system. Patent no. US 20100164324 A1.
- 164.Ni N, Zhang L, Wang Y, Liu F. 2014. High energy concentration dielectric elastomer micro force sensor. Patent no. CN 204043823 U.
- 165.Parker EAP sensors. http://promo.parker.com/promotionsite/eap/us/en/home. (accessed 31 May 2016).
- 166.StretchSense Ltd. Smart, soft, stretchable sensors: how they work. http://stretchsense.com. (accessed 31 May 2016).
- 167.Böse H, Fuß E. 2014. Novel dielectric elastomer sensors for compression load detection. Proc. SPIE 9056, 905614-1–13. ( 10.1117/12.2045133) [DOI] [Google Scholar]
- 168.Collings PJ, Hird M. 1997. Introduction to liquid crystals: chemistry and physics. Boca Raton, FL: CRC Press. [Google Scholar]
- 169.Terentjev EM, Warner M. 2007. Liquid crystal elastomers. Oxford, UK: Oxford University Press. [Google Scholar]
- 170.Küpfer J, Finkelmann H. 1991. Nematic liquid single crystal elastomers. Makromol. Chem. Rapid Comm. 12, 717–726. ( 10.1002/marc.1991.030121211) [DOI] [Google Scholar]
- 171.Clarke SM, Hotta A, Tajbakhsh AR, Terentjev EM. 2002. Effect of cross-linker geometry on dynamic mechanical properties of nematic elastomers. Phys. Rev. E. Stat. Nonlin. Soft Matter Phys. 65, 021804 ( 10.1103/PhysRevE.65.021804) [DOI] [PubMed] [Google Scholar]
- 172.Meier W, Finkelmann H. 1991. Liquid crystal elastomers with piezoelectric properties. MRS Bull. 16, 29–31. ( 10.1557/S0883769400057870) [DOI] [Google Scholar]
- 173.Brand HR. 1989. Electromechanical effects in cholesteric and chiral smectic liquid-crystalline elastomers. Die Makromol. Chemie, Rapid Commun. 10, 441–445. ( 10.1002/marc.1989.030100902) [DOI] [Google Scholar]
- 174.Chambers M, Finkelmann H, Remškar M, Sánchez-Ferrer A, Zalar B, Žumer S. 2009. Liquid crystal elastomer–nanoparticle systems for actuation. J. Mater. Chem. 19, 1524–1531. ( 10.1039/B812423J) [DOI] [Google Scholar]
- 175.Meyer RB, Liebert L, Strzelecki L, Keller P. 1975. Ferroelectric liquid crystals. J. Phys. Lett. 36, 69–71. ( 10.1051/jphyslet:0197500360306900) [DOI] [Google Scholar]
- 176.Lagerwall ST, Dahl I. 2011. Ferroelectric liquid crystals. Mol. Cryst. Liq. Cryst. 114, 151–187. ( 10.1080/00268948408071706) [DOI] [Google Scholar]
- 177.Papadopoulos P, Heinze P, Finkelmann H, Kremer F. 2010. Electromechanical properties of smectic C* liquid crystal elastomers under shear. Macromolecules 43, 6666–6670. ( 10.1021/ma1005028) [DOI] [Google Scholar]
- 178.Na YH, Aburaya Y, Orihara H, Hiraoka K. 2011. Measurement of electrically induced shear strain in a chiral smectic liquid-crystal elastomer. Phys. Rev. E. Stat. Nonlin. Soft Matter Phys. 83, 061709 ( 10.1103/PhysRevE.83.061709) [DOI] [PubMed] [Google Scholar]
- 179.Huang C, Zhang QM, Jákli A. 2003. Nematic anisotropic liquid-crystal gels—self-assembled nanocomposites with high electromechanical response. Adv. Funct. Mater. 13, 525–529. ( 10.1002/adfm.200304322) [DOI] [Google Scholar]
- 180.Brehmer M, Zentel R, Wagenblast G, Siemensmeyer K. 1994. Ferroelectric liquid-crystalline elastomers. Macromol. Chem. Phys. 195, 1891–1904. ( 10.1002/macp.1994.021950601) [DOI] [Google Scholar]
- 181.Harden J, Chambers M, Verduzco R, Luchette P, Gleeson JT, Sprunt S, Jákli A. 2010. Giant flexoelectricity in bent-core nematic liquid crystal elastomers. Appl. Phys. Lett. 96, 102907 ( 10.1063/1.3358391) [DOI] [Google Scholar]
- 182.Verduzco R, et al. 2010. Bent-core liquid crystal elastomers. J. Mater. Chem. 20, 8488 ( 10.1039/c0jm01920h) [DOI] [Google Scholar]
- 183.Meyer RB. 1969. Piezoelectric effects in liquid crystals. Phys. Rev. Lett. 22, 918–921. ( 10.1103/PhysRevLett.22.918) [DOI] [Google Scholar]
- 184.Mohammadi P, Liu LP, Sharma P. 2013. A theory of flexoelectric membranes and effective properties of heterogeneous membranes. J. Appl. Mech. 81, 011007 ( 10.1115/1.4023978) [DOI] [Google Scholar]
- 185.Brand HR, Pleiner H. 1990. Piezoelectricity versus flexoelectricity and electrostriction in cholesteric and chiral smectic liquid-crystalline elastomers. Die Makromol. Chemie, Rapid Commun. 11, 607–612. ( 10.1002/marc.1990.030111203) [DOI] [Google Scholar]
- 186.Herzer N, Guneysu H, Davies DJD, Yildirim D, Vaccaro AR, Broer DJ, Bastiaansen CWM, Schenning APHJ. 2012. Printable optical sensors based on H-bonded supramolecular cholesteric liquid crystal networks. J. Am. Chem. Soc. 134, 7608–7611. ( 10.1021/ja301845n) [DOI] [PubMed] [Google Scholar]
- 187.Wang ZL. 2006. Piezoelectric nanogenerators based on zinc oxide nanowire arrays. Science 312, 242–246. ( 10.1126/science.1124005) [DOI] [PubMed] [Google Scholar]
- 188.Park K-I, et al. 2012. Flexible nanocomposite generator made of BaTiO3 nanoparticles and graphitic carbons. Adv. Mater. 24, 2999–3004. ( 10.1002/adma.201200105) [DOI] [PubMed] [Google Scholar]
- 189.Hu Y, Lin L, Zhang Y, Wang ZL. 2012. Replacing a battery by a nanogenerator with 20 v output. Adv. Mater. 24, 110–114. ( 10.1002/adma.201103727) [DOI] [PubMed] [Google Scholar]
- 190.Pham TT, Lee KY, Lee J-H, Kim K-H, Shin K-S, Gupta MK, Kumar B, Kim S-W. 2013. Reliable operation of a nanogenerator under ultraviolet light via engineering piezoelectric potential. Energy Environ. Sci. 6, 841–846. ( 10.1039/c2ee23980a) [DOI] [Google Scholar]
- 191.Kingon AI, Srinivasan S. 2005. Lead zirconate titanate thin films directly on copper electrodes for ferroelectric, dielectric and piezoelectric applications. Nat. Mater. 4, 233–237. ( 10.1038/nmat1334) [DOI] [Google Scholar]
- 192.Wu JM, Xu C, Zhang Y, Wang ZL. 2012. Lead-free nanogenerator made from single ZnSnO3 microbelt. ACS Nano 6, 4335–4340. ( 10.1021/nn300951d) [DOI] [PubMed] [Google Scholar]
- 193.Crossley S, Kar-Narayan S. 2015. Energy harvesting performance of piezoelectric ceramic and polymer nanowires. Nanotechnology 26, 344001 ( 10.1088/0957-4484/26/34/344001) [DOI] [PubMed] [Google Scholar]
- 194.Crossley S, Whiter RA, Kar-Narayan S. 2014. Polymer-based nanopiezoelectric generators for energy harvesting applications. Mater. Sci. Technol. 30, 1613–1624. ( 10.1179/1743284714Y.0000000605) [DOI] [Google Scholar]
- 195.Lin B, Giurgiutiu V. 2006. Modeling and testing of PZT and PVDF piezoelectric wafer active sensors. Smart Mater. Struct. 15, 1085–1093. ( 10.1088/0964-1726/15/4/022) [DOI] [Google Scholar]
- 196.Kim KN, Chun J, Kim JW, Lee KY, Park J, Kim S, Wang ZL, Baik JM, Al KIMET. 2015. Highly stretchable 2D fabrics for wearable triboelectric nanogenerator under harsh environments. ACS Nano 9, 6394–6400. ( 10.1021/acsnano.5b02010) [DOI] [PubMed] [Google Scholar]
- 197.Li C, Wu PM, Shutter LA, Narayan RK. 2010. Dual-mode operation of flexible piezoelectric polymer diaphragm for intracranial pressure measurement. Appl. Phys. Lett. 96, 5–8. ( 10.1063/1.3299003) [DOI] [Google Scholar]
- 198.Feng GH, Tsai MY. 2010. Acoustic emission sensor with structure-enhanced sensing mechanism based on micro-embossed piezoelectric polymer. Sensors Actuators, A Phys. 162, 100–106. ( 10.1016/j.sna.2010.06.019) [DOI] [Google Scholar]
- 199.Murat Koç I, Akça E. 2013. Design of a piezoelectric based tactile sensor with bio-inspired micro/nano-pillars. Tribol. Int. 59, 321–331. ( 10.1016/j.triboint.2012.06.003) [DOI] [Google Scholar]
- 200.Kim DH, Kim B, Kang H. 2004. Development of a piezoelectric polymer-based sensorized microgripper for microassembly and micromanipulation. Microsyst. Technol. 10, 275–280. ( 10.1007/s00542-003-0330-y) [DOI] [Google Scholar]
- 201.Kärki S, Lekkala J, Kuokkanen H, Halttunen J. 2009. Development of a piezoelectric polymer film sensor for plantar normal and shear stress measurements. Sensors Actuators, A Phys. 154, 57–64. ( 10.1016/j.sna.2009.07.010) [DOI] [Google Scholar]
- 202.Chiu YY, Lin WY, Wang HY, Huang SB, Wu MH. 2013. Development of a piezoelectric polyvinylidene fluoride polymer-based sensor patch for simultaneous heartbeat and respiration monitoring. Sensors Actuators A Phys.189, 328–334 ( 10.1016/j.sna.2012.10.021) [DOI]
- 203.Li C, Wu PM, Lee S, Gorton A, Schulz MJ, Ahn CH. 2008. Flexible dome and bump shape piezoelectric tactile sensors using PVDF-TrFE copolymer. J. Microelectromechan. Syst. 17, 334–341. ( 10.1109/JMEMS.2007.911375) [DOI] [Google Scholar]
- 204.Chen X, Shao J, An N, Li X, Tian H, Xu C, Ding Y. 2015. Self-powered flexible pressure sensors with vertically well-aligned piezoelectric nanowire arrays for monitoring vital signs. J. Mater. Chem. C 3, 11 806–11 814. ( 10.1039/C5TC02173A) [DOI] [Google Scholar]
- 205.Maita F, et al. 2015. Ultraflexible tactile piezoelectric sensor based on low-temperature polycrystalline silicon thin-film transistor technology. IEEE Sens. J. 15, 3819–3826. ( 10.1109/JSEN.2015.2399531) [DOI] [Google Scholar]
- 206.Chang W-Y, Chu C-H, Lin Y-C. 2008. A flexible piezoelectric sensor for microfluidic applications using polyvinylidene fluoride. IEEE Sens. J. 8, 495–500. ( 10.1109/JSEN.2008.918749) [DOI] [Google Scholar]
- 207.Whiter RA, Narayan V, Kar-Narayan S. 2014. A scalable nanogenerator based on self-poled piezoelectric polymer nanowires with high energy conversion efficiency. Adv. Energy Mater. 4, 1400519 ( 10.1002/aenm.201400519) [DOI] [Google Scholar]
- 208.Bauer F. 2010. Relaxor fluorinated polymers: novel applications and recent developments. IEEE Trans. Dielectr. Electr. Insul. 17, 1106–1112. ( 10.1109/TDEI.2010.5539681) [DOI] [Google Scholar]
- 209.Kim KN, Chun J, Chae SA, Ahn CW, Kim IW, Kim S-W, Wang ZL, Baik JM. 2015. Silk fibroin-based biodegradable piezoelectric composite nanogenerators using lead-free ferroelectric nanoparticles. Nano Energy 14, 87–94. ( 10.1016/j.nanoen.2015.01.004) [DOI] [Google Scholar]
- 210.Lee J-H, Yoon H-J, Kim TY, Gupta MK, Lee JH, Seung W, Ryu H, Kim S-W. 2015. Micropatterned P(VDF-TrFE) film-based piezoelectric nanogenerators for highly sensitive self-powered pressure sensors. Adv. Funct. Mater. 25, 3203–3209. ( 10.1002/adfm.201500856) [DOI] [Google Scholar]
- 211.Choi YS, et al. 2013. Control of current hysteresis of networked single-walled carbon nanotube transistors by a ferroelectric polymer gate insulator. Adv. Funct. Mater. 23, 1120–1128. ( 10.1002/adfm.201201170) [DOI] [Google Scholar]
- 212.Lei K-F, Hsieh Y-Z, Chiu Y-Y, Wu M-H. 2015. The structure design of piezoelectric poly(vinylidene fluoride) (PVDF) polymer-based sensor patch for the respiration monitoring under dynamic walking conditions. Sensors 15, 18 801–18 812. ( 10.3390/s150818801) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 213.Tajitsu Y. 2015. Sensing complicated motion of human body using piezoelectric chiral polymer fiber. Ferroelectrics 480, 32–38. ( 10.1080/00150193.2015.1012410) [DOI] [Google Scholar]
- 214.Seminara L, Capurro M, Cirillo P, Cannata G, Valle M. 2011. Electromechanical characterization of piezoelectric PVDF polymer films for tactile sensors in robotics applications. Sensors Actuators A Phys. 169, 49–58. ( 10.1016/j.sna.2011.05.004) [DOI] [Google Scholar]
- 215.Chu B, Zhou X, Ren K, Neese B, Lin M, Wang Q, Bauer F, Zhang QM. 2006. A dielectric polymer with high electric energy density and fast discharge speed. Science 313, 334–336. ( 10.1126/science.1127798) [DOI] [PubMed] [Google Scholar]
- 216.Ramadan KS, Sameoto D, Evoy S. 2014. A review of piezoelectric polymers as functional materials for electromechanical transducers. Smart Mater. Struct. 23, 033001 ( 10.1088/0964-1726/23/3/033001) [DOI] [Google Scholar]
- 217.2013. Piezotech. PVDF and PVDF-TrFE Sensors. http://www.piezotech.fr/fr/2-products-piezoelectric-polymers/news/news-37-pvdf-and-pvdf-trfe-sensors.html. (accessed 31 May 2016).
- 218.Tiwana MI, Redmond SJ, Lovell NH. 2012. A review of tactile sensing technologies with applications in biomedical engineering. Sensors Actuators, A Phys. 179, 17–31. ( 10.1016/j.sna.2012.02.051) [DOI] [Google Scholar]
- 219.Piezotech. Piezoelectric films technical information. http://www.piezotech.fr/image/documents/22-31-32-33-piezotech-piezoelectric-films-leaflet.pdf (accessed 31 May 2016). [Google Scholar]
- 220.Kärki S, Lekkala J. 2012. A lumped-parameter transducer model for piezoelectric and ferroelectret polymers. Meas. J. Int. Meas. Confed. 45, 453–458. ( 10.1016/j.measurement.2011.10.029) [DOI] [Google Scholar]
- 221.Sorichetti PA, Santiago GD. 2014. Modeling thin-film piezoelectric polymer ultrasonic sensors. Rev. Sci. Instrum. 85, 115005, 1–7 ( 10.1063/1.4901966) [DOI] [PubMed] [Google Scholar]
- 222.Di C, Xue S, Tong J, Shi X. 2014. Study on electromechanical characterization of piezoelectric polymer PVDF in low-frequency band. J. Mater. Sci. Mater. Electron. 25, 4735–4742. ( 10.1007/s10854-014-2225-3) [DOI] [Google Scholar]
- 223.González A, García Á, Benavente-Peces C, Pardo L. 2016. Revisiting the characterization of the losses in piezoelectric materials from impedance spectroscopy at resonance. Materials 9, 72 ( 10.3390/ma9020072) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 224.Rajala S, Mettanen M, Tuukkanen S. 2015. Structural and electrical characterization of solution-processed electrodes for piezoelectric polymer film sensors. IEEE Sens. J. 16, 1692–1699. ( 10.1109/JSEN.2015.2504956) [DOI] [Google Scholar]
- 225.Marques SM, Rico P, Carvalho I, Gómez Ribelles JL, Fialho L, Lanceros-Méndez S, Henriques M, Carvalho S. 2016. MC3T3-E1 cell response to Ti1–x Agx and Ag-TiNx electrodes deposited on piezoelectric Poly(vinylidene fluoride) substrates for sensor applications. ACS Appl. Mater. Interfaces 8, 4199–4207. ( 10.1021/acsami.5b11922) [DOI] [PubMed] [Google Scholar]
- 226.Razian MA, Pepper MG. 2003. Design, development, and characteristics of an in-shoe triaxial pressure measurement transducer utilizing a single element of piezoelectric copolymer film. IEEE Trans. Neural Syst. Rehabil. Eng. 11, 288–293. ( 10.1109/TNSRE.2003.818185) [DOI] [PubMed] [Google Scholar]
- 227.Tanaka M, Lévêque JL, Tagami H, Kikuchi K, Chonan S. 2003. The ‘Haptic Finger’- a new device for monitoring skin condition. Skin Res. Technol. 9, 131–136. ( 10.1034/j.1600-0846.2003.00031.x) [DOI] [PubMed] [Google Scholar]
- 228.Tanaka M, Furubayashi M, Tanahashi Y, Chonan S. 2000. Development of an active palpation sensor for detecting prostatic cancer and hypertrophy. Mechatronics, 878 ( 10.1117/12.420885) [DOI] [Google Scholar]
- 229.Castro HF, Lanceros-Méndez S, Rocha JG. 2006. Separation of the pyro- and piezoelectric response of electroactive polymers for sensor applications. Mater. Sci. Forum 514–516, 202–206. ( 10.4028/www.scientific.net/MSF.514-516.202) [DOI] [Google Scholar]
- 230.Frubing P, Kremmer A, Neumann W, Guy IL. 2004. Dielectric relaxation in piezo-, pyro- and ferroelectric polyamide 11. IEEE Trans. Dielectr. Electr. Insul. 11, 271–279. ( 10.1109/TDEI.2004.1285897) [DOI] [Google Scholar]
- 231.Lee JH, et al. 2014. Highly stretchable piezoelectric-pyroelectric hybrid nanogenerator. Adv. Mater. 26, 765–769. ( 10.1002/adma.201303570) [DOI] [PubMed] [Google Scholar]
- 232.Ferrara L, Shahinpoor M, Kim KJ, Schreyer B, Keshavarzi A, Benzel E, Lantz J. 1999. Use of ionic polymer-metal composites (IPMCs) as a pressure transducer in the human spine. In Electroactive polymer actuators and devices (ed. Bar-Cohen Y.), pp. 394–401. Newport Beach, CA: SPIE. [Google Scholar]
- 233.Maffli L, Rosset S, Ghilardi M, Carpi F, Shea H. 2015. Ultrafast all-polymer electrically tunable silicone lenses. Adv. Funct. Mater. 25, 1656–1665. ( 10.1002/adfm.201403942) [DOI] [Google Scholar]
- 234.Measurement Specialties Inc. 1999. Piezo film sensors technical manual. https://www.sparkfun.com/datasheets/Sensors/Flex/MSI-techman.pdf (accessed 31 May 2016).
- 235.Madden JD, Cush RA, Kanigan TS, Brenan CJ, Hunter IW. 1999. Encapsulated polypyrrole actuators. Synth. Met. 105, 61–64. ( 10.1016/S0379-6779(99)00034-X) [DOI] [Google Scholar]
- 236.Otero TF, Cantero I, Villanueva S. 1999. EAP as multifunctional and biomimetic materials. In Electroactive polymer actuators and devices (ed. Bar-cohen Y.), pp. 26–34. Newport Beach, CA: SPIE. [Google Scholar]
- 237.Liu J, et al. 2015. Syringe-injectable electronics. Nat. Nanotechnol. 10, 629–636. ( 10.1038/nnano.2015.115) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 238.Balint R, Cassidy NJ, Cartmell SH. 2014. Conductive polymers: towards a smart biomaterial for tissue engineering. Acta Biomater. 10, 2341–2353. ( 10.1016/j.actbio.2014.02.015) [DOI] [PubMed] [Google Scholar]
- 239.Zhu B, Luo S-C, Zhao H, Lin H-A, Sekine J, Nakao A, Chen C, Yamashita Y, Yu H-H. 2014. Large enhancement in neurite outgrowth on a cell membrane-mimicking conducting polymer. Nat. Commun. 5, 4523 ( 10.1038/ncomms5523) [DOI] [PubMed] [Google Scholar]
- 240.Cullen DK, Patel AR, Doorish JF, Smith DH, Pfister BJ. 2008. Developing a tissue-engineered neural-electrical relay using encapsulated neuronal constructs on conducting polymer fibers. J. Neural Eng. 5, 374–384. ( 10.1088/1741-2560/5/4/002) [DOI] [PubMed] [Google Scholar]