Skip to main content
Acta Veterinaria Scandinavica logoLink to Acta Veterinaria Scandinavica
. 2016 Jun 29;58:44. doi: 10.1186/s13028-016-0224-5

Optimized methods for extracting circulating small RNAs from long-term stored equine samples

Lucia Unger 1, Nathalie Fouché 1, Tosso Leeb 2, Vincent Gerber 1, Alicja Pacholewska 1,2,
PMCID: PMC4928274  PMID: 27356979

Abstract

Circulating miRNAs in body fluids, particularly serum, are promising candidates for future routine biomarker profiling in various pathologic conditions in human and veterinary medicine. However, reliable standardized methods for miRNA extraction from equine serum and fresh or archived whole blood are sorely lacking. We systematically compared various miRNA extraction methods from serum and whole blood after short and long-term storage without addition of RNA stabilizing additives prior to freezing. Time of storage at room temperature prior to freezing did not affect miRNA quality in serum. Furthermore, we showed that miRNA of NGS-sufficient quality can be recovered from blood samples after >10 years of storage at −80 °C. This allows retrospective analyses of miRNAs from archived samples.

Electronic supplementary material

The online version of this article (doi:10.1186/s13028-016-0224-5) contains supplementary material, which is available to authorized users.

Keywords: Horse, Small RNA, microRNA, miRNA, RNA extraction, Serum, EDTA

Findings

Non-coding microRNAs (miRNAs), amongst other small RNAs, play an important role in shaping a cell’s transcriptome profile by regulation of mRNA transcription and/or translation [1] and may thus affect multiple target genes. In human medicine, miRNAs are promising diagnostic and prognostic biomarkers in cancer and other complex diseases [2].

In equine medicine, the knowledge about miRNAs in physiologic and pathologic conditions is still very limited restricted to certain diseases only, and thus warrants further investigation in this species [36].

In contrast to mRNA, miRNA molecules are surprisingly stable—even in tissue samples of compromised quality [7]—which supports the possibility of routine use of miRNA fingerprints as biomarkers in clinical practice. Small RNA extraction methods have been established for model organisms like human and mouse. Still, optimized procedures for circulating miRNA extraction might differ among species and there is little experience with extraction from equine samples [8, 9]. In serum and plasma, extracellular miRNAs are only present in low concentrations and their exact measurements may be affected by interference with DNA, degraded RNA, erythrocyte-derived miRNAs, and blood contaminants like heme and immunoglobulins [10, 11].

For miRNA studies using equine EDTA blood, the use of PAXgene blood RNA tubes in combination with the PAXgene blood RNA extraction kit was recommended [6]. However, particularly for retrospective studies, archived blood samples stored for years without any RNA stabilizing additives may be the only available material. The aim of our study was to compare different methods for the isolation of miRNAs from equine serum, fresh and archived EDTA blood samples.

For miRNA extraction from serum samples we assessed how RNA yield is affected by the performance of three column-based and one column-free method, two different lysis reagents, and the effects of storage time at room temperature (RT), serum input volume, performing a second phenol extraction, and a second column elution. We performed our analysis on serum samples from three horses. As we assessed a large number of different parameters, we did not analyse all possible 576 combinations, but rather chose an incomplete matrix of 60 combinations that allowed us to address each of the six investigated parameters (Additional file 1).

RNA isolation was performed according to the protocols of the four different manufacturers: ZR Whole-Blood RNA MiniPrep, Zymo Reasearch; Direct-zol RNA MiniPrep, Zymo Research; miRNeasy Serum/Plasma Kit, Qiagen), and standard TRIzol method [12]. The kits resulted in comparable miRNA yields that ranged from 0.13 to 0.64 ng RNA/100 μl serum (Table 1). The Direct-zol RNA MiniPrep was the fastest procedure, however, it had the lowest maximum sample loading volume (up to 100 μl). The highest final concentrations of the isolated small RNA were obtained with the miRNeasy and TRIzol methods (up to 138 pg/μl, Table 1). We chose the miRNeasy serum/plasma kit as our preferred method as the column-based purification is less prone to handling errors. The use of TRIzol as lysis buffer in combination with miRNeasy columns revealed similar results in terms of RNA yield as QIAzol, which is recommended by the manufacturer (Wilcoxon signed rank test P = 0.57).

Table 1.

Small RNA extraction kit comparison

Kit Horse ID Serum volume (μl) RNA concentration, Nanodrop (ng/μl) Elution volume (μl) Small RNA concentration, Bioanalyzer (pg/μl) miRNA in small RNA (%) miRNA/100 μl serum (ng)
ZR WB 1 200 1.85 8 89.4 46 0.17
ZR WB 3 200 3.65 8 69.5 63 0.18
Direct-zol 1 100 2.70 50 15.0 86 0.64
Direct-zol 3 100 0.45 50 12.8 53 0.34
miRNeasy 1 200 56.23 12 30.4 72 0.13
miRNeasy 3 200 11.69 12 126.2 77 0.58
TRIzol 1 400 52.98 10 138.5 63 0.22
TRIzol 3 400 138.21 10 127.9 43 0.14

RNA extraction results with different kits used. Due to differences in serum and elution volumes used, the RNA/miRNA concentration is given in RNA per 100μl of serum. RNA was measured with Nanodrop and miRNA with Bioanalyzer. The concentration was not measurable with the Qubit high sensitivity RNA kit. Due to very low concentration, the Nanodrop results should be treated with caution

We next assessed the effect of serum storage times on the performance of the miRNeasy method (Additional File 1). Serum aliquots were stored for 1, 5, or 24 h at RT before freezing at −80 °C. The storage time at RT did not have a significant effect on the RNA yield per 100 μl serum used (Kruskal–Wallis test P = 0.12) (Additional file 1).

To increase the efficiency of the RNA extraction with miRNeasy serum/plasma kit the following procedures were tested: (1) second extraction: by adding 600 μl RNase-free water to the remaining organic phase, and further steps as indicated by the manufacturer; (2) second elution: re-using the first eluate; and (3) increased serum volume: 5× or 10× multiplication of 200 μl serum processed individually for the phase separation and then loaded sequentially on a single column (Additional file 1). The second elution did not show a significant increase in RNA yield (Wilcoxon signed rank test P = 0.07) and after the second extraction RNA was no longer detectable and therefore none of those steps were considered as advantageous. Increased serum volume improved the RNA yield in samples processed with QIAzol, therefore, 1 ml of serum was chosen as the minimum and 2 ml as the optimum volume balancing RNA yield and the time required for the procedure.

To further assess the quality of the small RNA extracted with the optimised procedure we used six serum small RNA samples (36–174 ng) for next generation sequencing on a MiSeq (Additional file 1). Pre-processed sequencing reads in FASTQ format are available at http://www.ebi.ac.uk/ena/data/view/PRJEB10829. Read length distribution revealed a peak within the miRNA range and an even higher peak within the piRNA range (Fig. 1). This was in agreement with a previous study performed on pig serum [9].

Fig. 1.

Fig. 1

Sequencing tag length distribution. The reads length distribution of six serum small RNA libraries is shown. The bars indicate mean number of tags per sample and the error bars indicate standard errors

To corroborate our findings we isolated 120 miRNA samples with the optimized protocol (Additional file 2). The RNA yield ranged from 4 to 876 ng/100 μl serum (mean = 39 ng/100 μl serum). Only two samples showed high level of haemolysis and therefore the effect of haemolysis on serum RNA content [13] could not be investigated in this study.

For the optimization of miRNA extraction from archived EDTA blood samples we compared the PAXgene blood RNA kit with the PAXgene blood miRNA kit that is designed specifically for small RNA enrichment. For this comparison we used six horse EDTA samples stored for 12 weeks, 5 or 11 years (Additional file 3) at −80 °C without addition of RNA stabilizing agents. Before thawing, samples were visually inspected for separation of plasma and red blood cells which was considered to be a sign of prolonged storage at RT prior to freezing. All samples were gently thawed on ice and 2.5 ml was transferred to a PAXgene blood RNA tube and incubated for 16 h as previously described [14]. Samples extracted with both kits did not show significantly different RNA concentration (Wilcoxon signed rank test P = 0.16) whereas the miRNA in small RNA ratio (Agilent 2100 Bioanalyzer) was increased if the PAXgene blood miRNA kit was used (Fig. 2a, b).

Fig. 2.

Fig. 2

RNA quality of equine EDTA blood samples. Amount of miRNA (Bioanalyzer, small RNA chip) derived from the same short-term stored sample extracted with PAXgene blood RNA (a) or miRNA (b) kit. RNA quality (Fragment Analyzer) of long-term stored samples (11 years) with (c) or without (d) phase separation extracted with PAXgene blood RNA kit

We next assessed the effect of (1) storage time and (2) sample handling before freezing on the RNA quality and quantity using the PAXgene blood miRNA kit and EDTA blood samples derived from 25 horses (Additional file 3). Samples of two different sampling periods were compared (11 short-term stored samples: 12 weeks vs. 14 long-term stored samples: 5–11 years): Whereas no significant changes in RNA yield could be identified between samples of the two sampling periods (Wilcoxon rank sum test P = 0.18), the RNA quality was significantly lower in long-term stored samples (Wilcoxon rank sum test P = 6.10e−4). Phase separation in long-term stored samples did not have a significant effect on RNA concentration (Wilcoxon rank sum test P = 0.31), but had a significant effect on RNA quality (Wilcoxon rank sum test P = 1.02e−4) (Fig. 2c, d). In archived samples without visible phase separation (n = 5), the best RNA quality achieved was RQN = 8.3 (sample stored 9 years, Additional file 3).

All 120 serum and 21 EDTA small RNA samples extracted with optimized procedures were successfully converted into single-end libraries and sequenced on an Illumina HiSeq (Additional file 2). The number of sequencing tags after data pre-processing ranged from 7.1 to 16.5 million.

In this study we showed that compared to human an increased volume of equine serum is needed to obtain sufficient amounts of small RNA for sequencing, as in bovine samples [9]. However, using manual extraction only 2 ml of serum is needed, compared to 9 ml for the previously described extraction with the QIAcube robotic system [9]. Similar to [14], we were able to rescue RNA of good quality from some long-term stored equine EDTA blood samples via gentle thawing on ice and transfer to a PAXgene blood RNA tube.

Additional files

13028_2016_224_MOESM1_ESM.xlsx (49.5KB, xlsx)

Additional file 1. RNA extraction from serum. A table in XLSX format with RNA concentration and yield measured with Qubit, miRNA concentration and rRNA contamination measured with Bioanalyzer in samples used for pilot experiments during method optimization. Read numbers of the six samples sequenced are also given.

13028_2016_224_MOESM2_ESM.xlsx (61.4KB, xlsx)

Additional file 2. Serum RNA extraction results from 120 samples. A table in XLSX format with serum absorbances at 414 nm, serum volume used, sample collection year, and RNA concentrations obtained using the optimized procedures and measured with Qubit and Bioanalyzer.

13028_2016_224_MOESM3_ESM.xlsx (13.2KB, xlsx)

Additional file 3. RNA extraction from EDTA. A table in XLSX format with RNA concentration and yield measured with Qubit, miRNA concentration measured with Bioanalyzer, and RNA quality number (RQN) measured by Fragment Analyzer in samples used for pilot experiments during method optimization and with already optimized method.

Authors’ contributions

AP, VG, and TL conceived and designed the experiments. LU, NF, and AP carried out the experiments. LU, NF, and AP analyzed the data. LU, TL, VG, and AP wrote the paper. All authors read and approved the final manuscript.

Acknowledgements

The authors would like to thank all participating horse owners and veterinarians for their support of this study. We would like to thank Simone Lanz and Muriel Fragnière involved in the experimental part of the project, as well as Ghalia Boubaker, Vidhya Jagannathan, and Bart van den Borne for their help. We also appreciate the support of the Next Generation Sequencing Platform of the University of Bern.

Competing interests

The authors declare that they have no competing interests.

Ethics approval

All animal experiments were performed according to the local regulations and with the consent of the horse owners. Sample collection was performed for diagnostics or was approved by the Animal Experimentation Committee of the Canton of Bern, Switzerland (BE33/07, BE58/10 and BE10/13).

Funding

The presented study was funded by Swiss National Science Foundation: Grant No. 31003A-162548/1; and Swiss Institute of Equine Medicine Research.

Abbreviations

EDTA

ethylenediamine tetraacetic acid

miRNA

micro RNA

RT

room temperature, i.e. around 20 °C

Footnotes

Electronic supplementary material

The online version of this article (doi:10.1186/s13028-016-0224-5) contains supplementary material, which is available to authorized users.

Contributor Information

Lucia Unger, Email: lucia.unger@vetsuisse.unibe.ch.

Nathalie Fouché, Email: nathalie.fouche@vetsuisse.unibe.ch.

Tosso Leeb, Email: tosso.leeb@vetsuisse.unibe.ch.

Vincent Gerber, Email: vinzenz.gerber@vetsuisse.unibe.ch.

Alicja Pacholewska, Email: alicja.pacholewska@vetsuisse.unibe.ch.

References

  • 1.Bartel DP. MicroRNAs: genomics, biogenesis, mechanism, and function. Cell. 2004;116:281–297. doi: 10.1016/S0092-8674(04)00045-5. [DOI] [PubMed] [Google Scholar]
  • 2.Liang H, Gong F, Zhang S, Zhang C-Y, Zen K, Chen X. The origin, function, and diagnostic potential of extracellular microRNAs in human body fluids. Wiley Interdiscip Rev RNA. 2014;5:285–300. doi: 10.1002/wrna.1208. [DOI] [PubMed] [Google Scholar]
  • 3.Buechli ME, Lamarre J, Koch TG. MicroRNA-140 expression during chondrogenic differentiation of equine cord blood-derived mesenchymal stromal cells. Stem Cells Dev. 2013;22:1288–1296. doi: 10.1089/scd.2012.0411. [DOI] [PubMed] [Google Scholar]
  • 4.van der Kolk JH, Pacholewska A, Gerber V. The role of microRNAs in equine medicine: a review. Vet Q. 2015;35:88–96. doi: 10.1080/01652176.2015.1021186. [DOI] [PubMed] [Google Scholar]
  • 5.Desjardin C, Vaiman A, Mata X, Legendre R, Laubier J, Kennedy SP, et al. Next-generation sequencing identifies equine cartilage and subchondral bone miRNAs and suggests their involvement in osteochondrosis physiopathology. BMC Genom. 2014;15:798. doi: 10.1186/1471-2164-15-798. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Barrey E, Bonnamy B, Barrey EJ, Mata X, Chaffaux S, Guerin G. Muscular microRNA expressions in healthy and myopathic horses suffering from polysaccharide storage myopathy or recurrent exertional rhabdomyolysis. Equine Vet J. 2010;42:303–310. doi: 10.1111/j.2042-3306.2010.00267.x. [DOI] [PubMed] [Google Scholar]
  • 7.Peiró-Chova L, Peña-Chilet M, López-Guerrero JA, García-Giménez JL, Alonso-Yuste E, Burgues O, et al. High stability of microRNAs in tissue samples of compromised quality. Virchows Arch. 2013;463:765–774. doi: 10.1007/s00428-013-1485-2. [DOI] [PubMed] [Google Scholar]
  • 8.Hammerle-Fickinger A, Riedmaier I, Becker C, Meyer HHD, Pfaffl MW, Ulbrich SE. Validation of extraction methods for total RNA and miRNA from bovine blood prior to quantitative gene expression analyses. Biotechnol Lett. 2009;32:35–44. doi: 10.1007/s10529-009-0130-2. [DOI] [PubMed] [Google Scholar]
  • 9.Spornraft M, Kirchner B, Haase B, Benes V, Pfaffl MW, Riedmaier I. Optimization of extraction of circulating RNAs from plasma—enabling small RNA sequencing. PLoS One. 2014;9:e107259. doi: 10.1371/journal.pone.0107259. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Schwochow D, Serieys LE, Wayne RK, Thalmann O. Efficient recovery of whole blood RNA - a comparison of commercial RNA extraction protocols for high-throughput applications in wildlife species. BMC Biotechnol. 2012;12:33. doi: 10.1186/1472-6750-12-33. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Li X, Mauro M, Williams Z. Comparison of plasma extracellular RNA isolation kits reveals kit-dependent biases. Biotechniques. 2015;59:13–17. doi: 10.2144/000114306. [DOI] [PubMed] [Google Scholar]
  • 12.Chomczynski P, Sacchi N. Single-step method of RNA isolation by acid guanidinium thiocyanate-phenol-chloroform extraction. Anal Biochem. 1987;162:156–159. doi: 10.1016/0003-2697(87)90021-2. [DOI] [PubMed] [Google Scholar]
  • 13.Kirschner MB, Edelman JJB, Kao SCH, Vallely MP, Van Zandwijk N, Reid G. The impact of hemolysis on cell-free microRNA biomarkers. Front Genet. 2013;4:94. doi: 10.3389/fgene.2013.00094. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Beekman JM, Reischl J, Henderson D, Bauer D, Ternes R, Peña C, et al. Recovery of microarray-quality RNA from frozen EDTA blood samples. J Pharmacol Toxicol Methods. 2009;59:44–49. doi: 10.1016/j.vascn.2008.10.003. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

13028_2016_224_MOESM1_ESM.xlsx (49.5KB, xlsx)

Additional file 1. RNA extraction from serum. A table in XLSX format with RNA concentration and yield measured with Qubit, miRNA concentration and rRNA contamination measured with Bioanalyzer in samples used for pilot experiments during method optimization. Read numbers of the six samples sequenced are also given.

13028_2016_224_MOESM2_ESM.xlsx (61.4KB, xlsx)

Additional file 2. Serum RNA extraction results from 120 samples. A table in XLSX format with serum absorbances at 414 nm, serum volume used, sample collection year, and RNA concentrations obtained using the optimized procedures and measured with Qubit and Bioanalyzer.

13028_2016_224_MOESM3_ESM.xlsx (13.2KB, xlsx)

Additional file 3. RNA extraction from EDTA. A table in XLSX format with RNA concentration and yield measured with Qubit, miRNA concentration measured with Bioanalyzer, and RNA quality number (RQN) measured by Fragment Analyzer in samples used for pilot experiments during method optimization and with already optimized method.


Articles from Acta Veterinaria Scandinavica are provided here courtesy of BMC

RESOURCES