Transcatheter Aortic Valve Implantation With or Without Preimplantation Balloon Aortic Valvuloplasty: A Systematic Review and Meta‐Analysis

Rodrigo Bagur 1,2,, Chun Shing Kwok 4,5, Luis Nombela‐Franco 6, Peter F Ludman 7, Mark A de Belder 8, Sandro Sponga 9, Mark Gunning 4, James Nolan 4, Pantelis Diamantouros 1, Patrick J Teefy 1, Bob Kiaii 3,10, Michael W A Chu 3,10, Mamas A Mamas 4,5
PMCID: PMC4937264  PMID: 27412897

Abstract

Background

Preimplantation balloon aortic valvuloplasty (BAV) is considered a routine procedure during transcatheter aortic valve implantation (TAVI) to facilitate prosthesis implantation and expansion; however, it has been speculated that fewer embolic events and/or less hemodynamic instability may occur if TAVI is performed without preimplantation BAV. The aim of this study was to systematically review the clinical outcomes associated with TAVI undertaken without preimplantation BAV.

Methods and Results

We conducted a search of Medline and Embase to identify studies that evaluated patients who underwent TAVI with or without preimplantation BAV for predilation. Pooled analysis and random‐effects meta‐analyses were used to estimate the rate and risk of adverse outcomes. Sixteen studies involving 1395 patients (674 with and 721 without preimplantation BAV) fulfilled the inclusion criteria. Crude device success was achieved in 94% (1311 of 1395), and 30‐day all‐cause mortality occurred in 6% (72 of 1282) of patients. Meta‐analyses evaluating outcomes of strategies with and without preimplantation BAV showed no statistically significant differences in terms of mortality (relative risk [RR] 0.61, 95% CI 0.32–1.14, P=0.12), safety composite end point (RR 0.85, 95% CI 0.62–1.18, P=0.34), moderate to severe paravalvular leaks (RR 0.68, 95% CI 0.23–1.99, P=0.48), need for postdilation (RR 0.86, 95% CI 0.66–1.13, P=0.58), stroke and/or transient ischemic attack (RR 0.72, 95% CI 0.30–1.71, P=0.45), and permanent pacemaker implantation (RR 0.80, 95% CI 0.49–1.30, P=0.37).

Conclusions

Our analysis suggests that TAVI procedures with or without preimplantation BAV were associated with similar outcomes for a number of clinically relevant end points. Further studies including a large number of patients are needed to ascertain the impact of TAVI without preimplantation BAV as a standard practice.

Keywords: aortic stenosis, aortic valve replacement, balloon aortic valvuloplasty, transcutaneous aortic valve implantation, transfemoral aortic valve implantation

Subject Categories: Aortic Valve Replacement/Transcather Aortic Valve Implantation, Catheter-Based Coronary and Valvular Interventions

Introduction

Transcatheter aortic valve implantation (TAVI) is the definitive alternative option for patients with severe symptomatic aortic stenosis that are considered either unsuitable or high risk for surgical aortic valve replacement.1, 2 Preimplantation balloon aortic valvuloplasty (BAV) is a standard procedure during TAVI. Predilation BAV creates fractures of calcified leaflets and increases leaflet flexibility, thereby facilitating delivery of the TAVI catheter across the aortic valve and enhancing prosthesis implantation and expansion within the calcified aortic valve annulus. Importantly, it has been speculated that fewer embolic events and/or less hemodynamic instability may occur if TAVI is performed without preimplantation BAV. Nonetheless, there is also a concern that omitting preimplantation BAV may result in the need for more postimplant BAV postdilation and possible associated complications. Notably, this approach has been proposed only in single‐center studies with relatively small sample sizes; therefore, the benefits of TAVI without preimplantation BAV may be overestimated and subject to significant selection biases. We sought to undertake a systematic review and meta‐analysis to study the clinical outcomes associated with TAVI procedures performed with and without preimplantation BAV to gain insight into optimal practice during TAVI procedures.

Methods

Eligibility Criteria

We included studies that evaluated patients who underwent TAVI with and without preimplantation (procedural) BAV for predilation. Studies included in the meta‐analysis had to be parallel group in design, with one group having TAVI with preimplantation BAV and the other having TAVI without preimplantation BAV. We also included single‐arm studies that evaluated the feasibility of performing TAVI without preimplantation BAV. In terms of outcomes, included studies must have evaluated procedural or device success and ≥1 of the following events: need for postimplantation balloon postdilation, valve embolization, need for a second valve, vascular complications, bleeding, neurological events (stroke or transient ischemic attack), acute kidney injury, permanent pacemaker implantation, significant residual aortic regurgitation or paravalvular leakages (PVLs), and mortality. Early safety end point, if available, was reported in accordance to Valve Academic Research Consortium (VARC‐2) definitions3: all‐cause mortality (at 30 days), all stroke (disabling and nondisabling), life‐threatening bleeding, acute kidney injury stage 2 or 3 (including renal replacement therapy), coronary artery obstruction requiring intervention, major vascular complication, valve‐related dysfunction requiring repeat procedure (BAV, TAVI, or surgical valve replacement). The reporting of outcomes had to include either crude events in each group or any risk or odds estimate (relative risk [RR], hazard ratio, odds ratio) with a 95% CI. There was no restriction based on the design of the study or the duration of follow‐up. We excluded reports in which BAV may have been performed weeks or months before TAVI (so‐called bridge‐to‐TAVI procedure) and isolated case reports, reviews, and editorials.

Search Strategy

We conducted a search of Medline and Embase from conception to September 20, 2015, using OvidSP (Ovid Technologies). The following exact search terms were used: (“transcatheter aortic valve implantation” OR “TAVI” OR “transcatheter aortic valve replacement” OR “TAVR”) AND (“Balloon aortic valvuloplasty”). There was no restriction based on language of study, and abstracts and unpublished studies were included. The references of the included studies and relevant reviews were checked for additional studies. A flow diagram is provided following the Preferred Reporting Items for Systematic reviews and Meta‐Analyses (PRISMA) (Figure 1).

Figure 1.

Figure 1

Flow diagram based on the Preferred Reporting Items for Systematic reviews and Meta‐Analyses (PRISMA). BAV indicates balloon aortic valvuloplasty; TAVI, transcatheter aortic valve implantation.

Institutional review board approval and patient consent were not required because of the nature of this study as a systematic review and meta‐analysis.

Study Selection

Two reviewers (R.B. and C.S.K.) independently checked all titles and abstracts for studies that met the inclusion criteria. The full reports of potentially relevant studies were retrieved, and data were independently extracted on study design, participant characteristics, treatment groups, outcome events, follow‐up, and results. Any discrepancies between reviewers were resolved by consensus after consulting a third reviewer (M.A.M.).

Quality Assessment

Risk of bias was assessed by considering ascertainment of treatment groups, ascertainment of outcomes, loss to follow‐up, and consideration of potential confounders in the data analysis. Publication bias was assessed using funnel plots if there were >10 studies in a meta‐analysis and no evidence of substantial statistical heterogeneity.4

Data Analysis

We used RevMan (version 5.1.7; Nordic Cochrane Centre) to perform random‐effects meta‐analysis using the Mantel–Haenszel method to determine pooled risk ratios for dichotomous data. The I2 statistic was used to assess the consistency among studies, with I2<25% considered low, I2=50% considered moderate, and I2>75% considered high heterogeneity. If data or studies for meta‐analysis were insufficient, we pooled the studies using a weighted average or performed a narrative synthesis of studies that were too heterogeneous to pool. Sensitivity analyses were further performed according to the access site and type of valve for meta‐analysis.

Results

Study Population

A total of 16 studies5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20 including 1395 patients fulfilled the inclusion criteria (Figure 1). The sample size, age, sex, hemodynamic echocardiographic data, predicted operative mortality risk evaluation scores, and some of the baseline characteristics are described in Table 1. Among the studied populations, TAVI was performed without preimplantation BAV in 721 patients and with preimplantation BAV in 674 patients. The mean age was 81.3 years, and 49.6% of participants were female in 14 studies that reported both age and sex.5, 6, 7, 8, 9, 11, 14, 15, 16, 17, 18, 19, 20 The balloon‐expandable Edwards SAPIEN XT or SAPIEN 3 valve was implanted in 10 studies6, 10, 11, 12, 14, 16, 17, 18, 19, 20 including 793 patients, and the self‐expandable Medtronic CoreValve was used in 7 studies5, 7, 8, 9, 13, 15, 17 including 602 patients. One study included both types of bioprostheses.17 Access was transfemoral, exclusively, in 8 studies5, 7, 8, 12, 14, 17, 18, 20; transfemoral, trans‐subclavian, or direct aortic in 4 studies9, 10, 13, 15; transapical in 3 studies6, 11, 16; and transfemoral or transapical access in 1 study.19 There were 4 prospective cohort studies,5, 7, 9, 10 4 cohort studies,6, 8, 13, 17 3 retrospective cohort studies,11, 12, 19 2 case‐matched studies,15, 18 2 case–control studies,14, 20 and 1 propensity‐matched study.16

Table 1.

Characteristics of the Study Population

Study and Year of Publication Without BAV Age Female Mean Gradient AVA (cm2) LVEF EuroSCORE STS‐PROM With BAV Age Female Mean Gradient AVA (cm2) LVEF EuroSCORE STS‐PROM Differences Between Baseline Characteristics
Grube et al5 2011 60 80.1±6.4
53.3%
47.8±15.5
0.66±0.2
NA
23.3±15.2
NA
Wendler et al6 2012 6 82±3
33%
49±5
0.6±0.18
NA
30±12
NA
Mendiz et al7 2013 51 79±8
65%
80±22 (peak)
0.7±0.2
56±10%
20±15
NA
Rück et al8 2013 78 NA NA 19
NA
Fiorina et al9 2014 55 83±7
51%
44±13
0.39±0.1*
49±13%
27±18
10±8*
45 83±8
44%
48±16
0.36±0.1*
49±13%
22±14
7±4*
  1. Indexed AVA, P=0.09

  2. STS score, P=0.03

  3. Prior MI 20% no‐BAV vs 6% in BAV, P=0.05

Davies et al10 2014 12 83±3
50%
56±19 (peak)
0.7±0.2
56±19%
23±12
6±3
Conradi et al11 2014 50 78±8
46%
28±14
0.9±0.4
NA
21±14
8±7
50 81±7
52%
31±17
0.8±0.2
NA
23±13
8±5
Similar
Aggarwal et al12 2014 52 NA NA NA 61 NA NA NA NA
Giustino et al13 2014 73 NA NA NA 133 NA NA NA Similar
Möllmann et al14 2014 26 81.6±6.5
42.3%
36.0±17.3*
0.7±0.2
55%*
24.6±8.7
6.2±2.7
30 82.2±5.4
43.3%
48.5±17.7*
0.6±0.2
60%*
21.4±12.1
6.2±3.1
  1. LVEF 55% (IQR 35.0–60.0%) in non‐BAV vs 60% (IQR 53.8–65.0%) in BAV group, P=0.01

  2. Mean gradient, P=0.01

Kochman et al15 2014 8 78.1±8.4
50%
46.0±14.1
0.58±0.15
38.4%
20±6
NA
16 83.3±3.7
31.3%
55.9±12.0
0.59±0.17
46.8%
19±7
NA
Similar
Kempfert et al16 2015 40 79
30%
42
NA
52%
NA
7.62
40 80
30%
40
NA
51%
NA
7.22
Differences were observed between the no‐BAV and BAV groups before adjustment for variables male sex (52% vs 70%, P=0.05) and stroke (23% vs 7%, P=0.01). The cohorts were similar after propensity score matching.
Islas et al17 2015 79§ 82.4±5.5
65.7%
47.3±14.7
0.6±0.2
56.9±12.5%
18.6±9.8
NA
170 82.8±5.7
64.7%
50.1±17.7
0.7±0.2
58.7±13.4%
17.9±9.6
NA
Similar
Conradi et al18 2015 26 81.3±6.3
61.5%
38±14
0.8±0.2
19% ≤45%
15±13
6±3
26 81.7±5.2
61.4%
42±17
0.7±0.2
15% ≤45%
15±12
5±2
Similar
Wong et al19 2015 50 84.3±6.6
58%
44±13
0.7±0.2
50±14%
NA
8.5±4.6
71 84.4±7.5
46%
51±14
0.7±0.2
49±15%
NA
9.4±5.3
In the transfemoral BAV group, smoking was 42% vs 68% in transapical no‐BAV (P=0.005), peripheral vascular disease was 20% vs 38% in transapical no‐BAV (P=0.03). AV calcification tended to be higher (P=0.07) in the transfemoral BAV vs the transapical no‐BAV group. Conversely, the transapical no‐BAV tended to have more (P=0.06) porcelain aorta than the transfemoral BAV group.
Bijuklic et al20 2015 55 82.9±6.8
47.3%
40.0±12.7
0.71±0.2
53.0±13.8%
21.4±15.1
NA
32 83.8±5.2
56.2%
40.5±13.4
0.71±0.2
57.2±11.9%
23.7±16.0
NA
Similar

Values are expressed as number of patients for no‐BAV (without preimplantation BAV) and BAV (with preimplantation BAV). Values are expressed as mean±SD for age and mean gradient (mm Hg). AV indicates aortic valve; AVA, aortic valve area; BAV, balloon aortic valvuloplasty; IQR, interquartile range; Log‐EuroSCORE, logistic European system for cardiac operative risk evaluation; LVEF, left ventricle ejection fraction; MI, myocardial infarction; NA, not available; STS‐PROM, Society of Thoracic Surgeons Score for Prediction of Mortality.

*Difference was encountered.

Edwards SAPIEN XT, n=51; Medtronic CoreValve, n=28.

Edwards SAPIEN XT, n=115; Medtronic CoreValve, n=55.

§Percentage of patients with LVEF ≤45%.

Study Designs and Quality Assessment

Study design, time frame, country of origin, and quality assessment for included studies are reported in Table 2. Ascertainment of outcomes varied from medical record reviews to prospective evaluation with adjudicated clinical end points. All studies contained reliable data, and there was no loss to follow‐up. Follow‐up of patients varied and included in‐hospital outcomes, clinical visits, echocardiographic assessment, and telephone calls up to 12 months from the date of implant.

Table 2.

Design and Quality Assessment of Included Studies

Study and Year of Publication Design; Dates; Country Ascertainment of Treatment Group Ascertainment of Outcomes Loss to Follow‐up Adjustment for Confounders
Grube et al5 2011 Prospective cohort study; 2009–2010; international Reliable Follow‐up by clinical visits and echocardiography None None, crude results
Wendler et al6 2012 Cohort study; unclear; United Kingdom Reliable Assessment at 30 days None None, crude results
Mendiz et al7 2013 Prospective cohort study; May 2010 to May 2012; Argentina Reliable Follow‐up by clinical visits, echocardiography and telephone calls None None, crude results
Rück et al8 2013 Cohort study; started September 2012; Sweden Reliable Unclear None None, crude results
Fiorina et al9 2014 Prospective cohort study; June 2012 to June 2013; Italy Reliable Follow‐up by clinical visits and echocardiography None None, crude results
Davies et al10 2014 Prospective cohort study; unclear; United Kingdom Reliable Unclear None None, crude results
Conradi et al11 2014 Retrospective cohort study; May 2011 to December 2012; Germany Reliable Clinical end points were adjudicated None, retrospective None, crude results
Aggarwal et al12 2014 Retrospective cohort; March 2012 to April 2014; United Kingdom Reliable Unclear None, retrospective None, crude results
Giustino et al13 2014 Cohort study; November 2007 to September 2013; Italy Reliable Assessment at 30 days and 12 months None None, crude results
Möllmann et al14 2014 Case–control study; unclear; Germany Reliable Assessment at 30 days None None, crude results
Kochman et al15 2014 Case‐matched study; March 2010 to April 2013; Poland Reliable Follow‐up by clinical visits at 30 days, 6 months and 12 months None Case‐matched analysis
Kempfert et al16 2015 Propensity‐matched analysis; March 2012 to July 2013; Germany Reliable Clinical follow‐up at 30 days None Propensity‐matched analysis
Islas et al17 2015 Cohort study; January 2009 to August 2014; Spain Reliable Clinical follow‐up at 30 days None None, crude results
Conradi et al18 2015 Case‐matched study; unclear; Germany Reliable Clinical end points were adjudicated None, retrospective Matched by logistic regression and nearest neighbors
Wong et al19 2015 Retrospective cohort; May 2012 to December 2013; United States Reliable Follow‐up by clinical visits None, retrospective None, crude results
Bijuklic et al20 2015 Case–control study; unclear; Germany Reliable Follow‐up at 30 days None, retrospective None, crude results

Association of Preimplantation BAV Versus No BAV and Outcomes

Device type, access site, procedure‐related outcomes, and follow‐up assessment for all included studies reporting crude rate of events are summarized in Table 3. A pooled analysis reporting crude rates for outcomes of studies with and without preimplantation BAV according to valve type is shown in Table 4. Further separate analyses were performed including only studies of patients undergoing TAVI without preimplantation BAV (Table 5) and with preimplantation BAV (Table 6).

Table 3.

Procedure‐Related and Clinical Outcomes

Study and Year of Publication Type of Valve, Approach Time Frame of Assessment Assessment Definitions Outcomes No‐BAV BAV
Grube et al5 2011 CoreValve, transfemoral 30 days VARC Procedural success 58/60 (96.7) NA
Need for a second valve 1/60 (1.7)
Conversion to surgery 1/60 (1.7)
Postdilation 10/60 (16.7)
Moderate/severe AR 0/60 (0)
Myocardial infarction 0/60 (0)
Stroke/TIA 3/60 (50)
Pacemaker implantation 7/60 (11.7)
Major vascular complication 6/60 (10)
All‐cause mortality 4/60 (6.7)
Wendler et al6 2012 SAPIEN XT, transapical 30 days VARC Procedural success 6/6 (100) NA
Postdilation 0/6 (0)
Moderate/severe AR 0/6 (0)
Trivial or mild AR 3/6 (50)
Acute kidney injury 1/6 (16.7)
All‐cause mortality 0/6 (0)
Mendiz et al7 2013 CoreValve, transfemoral 12 months VARC Device success 48/51 (94.2) NA
Need for bailout BAV predilation# 1/51 (1.96)
Postdilation 16/51 (31.4)
Moderate AR 1/51 (1.96)
Pacemaker implantation 14/49 (28.6)
Major vascular complication 3/51 (5.9)
Cardiac tamponade 1/51 (1.96)
Conversion to surgery 1/51 (1.96)
Stroke 1/51 (1.96)
Combined safety end point 8/51 (15.7)
30‐day mortality 2/51 (3.9)
7‐month (median time) mortality 7/51 (13.7)
Rück et al8 2013 CoreValve, transfemoral In hospital or 30 days Unclear Procedural success 77/78 (98.7) NA
Need for bailout BAV predilation# 1/78 (1.3)
Postdilation 19/78 (24.4)
Need for a second valve 14/78 (17.9)
Moderate AR 11/78 (14.1)
Severe AR 0/78 (0)
Myocardial infarction 0/78 (0)
Stroke 0/78 (0)
Pacemaker implantation 20/78 (25.6)
30‐day mortality 5/78 (6.4)
Fiorina et al9 2014 CoreValve, transfemoral or direct aortic 30 days VARC‐2 Device success 47/55 (85.5)* 29/45 (64.4)
Need for bailout BAV predilation# 1/55 (1.8)
Need for a second valve 2/55 (3.6) 2/45 (4.4)
Moderate or severe PVL 5/55 (9.1) 15/45 (33)**
Postdilation 19/55 (34.5) 23/45 (51.1)
Myocardial infarction 0/55 (0) 0/45 (0)
Stroke 0/55 (0) 0/45 (0)
Acute kidney injury 3/55 (5.5) 1/45 (2.2)
Major vascular complication 2/55 (3.6) 1/45 (2.2)
Minor vascular complication 0/55 (0) 4/45 (8.9)
Major bleeding 3/55 (5.5) 1/45 (2.2)
Pacemaker implantation 3/55 (5.5) 7/45 (15.6)
Safety end point 8/55 (14.5) 4/45 (8.9)
All‐cause mortality 1/55 (1.8) 2/45 (4.4)
Davies et al10 2014 SAPIEN XT, transfemoral or direct aortic Unclear Unclear Device success 12/12 (100) NA
Bleeding needing transfusion 0/12 (0)
Stroke 1/12 (8.3)
Pacemaker implantation 0/12 (0)
All‐cause mortality 0/12 (0)
Conradi et al11 2014 SAPIEN XT, transapical 30 days VARC‐2 Device success 47/50 (94) 43/50 (86)
Postdilation 4/50 (8) 2/50 (4)
Need for a second valve 1/50 (2) 1/50 (2)
Conversion to surgery 1/50 (2) 0/50 (0)
Stroke 1/50 (2) 3/50 (6)
Myocardial infarction 0/50 (0) 0/50 (0)
Major bleeding 1/50 (2) 1/50 (2)
Major access site complications 1/50 (2) 1/50 (2)
Acute kidney injury 1/50 (2) 2/50 (4)
Pacemaker implantation 5/50 (10) 4/50 (8)
Early safety end point 7/50 (14) 12/50 (24)
All‐cause mortality 2/50 (4) 5/50 (10)
Aggarwal et al12 2014 SAPIEN XT and SAPIEN 3
Transfemoral
NA VARC‐2 Device success 50/52 (96.1) 60/61 (98.3)
Moderate or severe AR 3/52 (5.8) 3/61 (4.9)
Postdilation 2/52 (4.0) 2/61 (3.4)
Procedural safety 18/52 (34.6) 31/61 (50.8)
Giustino et al13 2014 CoreValve, transfemoral, direct aortic, or subclavian 30 days and 12 months VARC‐2 Device success 73/73 (100) 133/133 (100)
Cardiac tamponade 6/73 (8.2)§ 3/133 (2.3)
Moderate AR needing postdilation 36/73 (49.3)§§ 47/133 (35.6)
Acute kidney injury 14/73 (19.4) 43/133 (32.3)
30‐day all‐cause mortality 4/73 (5.5) 4/133 (3.0)
30‐day cardiovascular mortality 4/73 (5.5) 2/133 (1.5)
Long‐term all‐cause mortality 17/73 (23.3) 24/133 (17.8)
Long‐term cardiovascular mortality 13/73 (17.6) 18/133 (13.3)
Möllmann et al14 2014 SAPIEN XT, transfemoral In hospital and 30 days VARC‐2 Procedural success 26/26 (100) 30/30 (100)
Postdilation 3/26 (11.5) 3/30 (10)
Cardiac tamponade 1/26 (3.8) 0/30 (0)
Moderate PVL 0/26 (0) 0/30 (0)
Major vascular complication 2/26 (7.7) 0/30 (0)
Pacemaker implantation 2/26 (7.7) 0/30 (0)
Acute kidney injury 1/26 (3.8) 0/30 (0)
30‐day mortality 0/26 (0) 3/30 (10)
Kochman et al15 2014 CoreValve, transfemoral or subclavian 12 months VARC‐2 Device success 8/8 (100) 15/16 (93.8)
Postdilation 3/8 (37.5) 2/16 (12.5)
Life‐threatening bleeding 1/8 (12.5) 0/16 (0)
Major vascular complication 2/8 (25) 6/16 (37.5)
Minor vascular complication 5/8 (62.5) 12/16 (75)
Pacemaker implantation 2/8 (25) 4/16 (25)
Myocardial infarction 0/8 (0) 1/16 (6)
Stroke 0/8 (0) 0/16 (0)
In‐hospital mortality 0/8 (0) 1/16 (6)
12‐month mortality 1/8 (12.5) 2/16 (12.5)
Kempfert et al16 2015 SAPIEN XT, transapical 30 days Unclear Device success 40/40 (100) 40/40 (100)
Need for a second valve 1/40 (2.5) 1/40 (2.5)
Postdilation 4/40 (10) 6/40 (15)
Mild or more residual PVL 4/40 (10) 3/40 (7.5)
Stroke 0/40 (0) 0/40 (0)
TIA 3/40 (7.5) 3/40 (7.5)
Pacemaker implantation 1/40 (2.5) 2/40 (5)
30‐day mortality 1/40 (2.5) 3/40 (7.5)
Islas et al17 2015 SAPIEN XT (n=166) and CoreValve (n=83), transfemoral 30 days VARC‐2 Procedural success 73 (92.3) 153 (90.1)
Need for a second valve 3 (3.8) 9 (5.3)
Conversion to surgery 2 (2.3) 9 (5.3)
Postdilation 14 (17.7) 32 (18.8)
Mild or more residual PVL 3 (3.8) 6 (3.5)
Stroke 1 (1.2) 3 (1.7)
Pacemaker implantation 5 (6.3) 24 (14.1)
30‐day mortality 2 (2.5) 20 (11.8)∫∫
Conradi et al18 2015 SAPIEN XT and SAPIEN 3, transfemoral 30 days VARC‐2 Device success 25/26 (96.2) 24/26 (92.3)
Need for a second valve 1/26 (3.8) 1/26 (3.8)
Annular rupture 0/26 (0) 1/26 (3.8)
Postdilation 0/26 (0) 3/26 (11.5)
Myocardial infarction 0/26 (0) 0/26 (0)
Stroke 1/26 (3.8) 2/26 (7.7)
Major or life‐threatening bleeding 2/26 (7.7) 2/26 (7.7)
Major access site complications 2/26 (7.7) 3/26 (11.5)
Acute kidney injury 3/26 (11.5) 0/26 (0)
Pacemaker implantation 4/26 (15.4) 4/26 (15.4)
30‐day mortality 2/26 (7.7) 2/26 (7.7)
Early safety 4/26 (15.4) 5/26 (19.2)
Wong et al19 2015 SAPIEN and SAPIEN XT, transfemoral or transapical 30 days VARC‐2 Device success 47/50 (94) 63/71 (88.7)
Valve embolization 1/50 (2) 0/71 (0)
Annular rupture 0/50 (0) 1/71 (1.4)
Postdilation 15/50 (30) 24/71 (34)
Myocardial infarction 0/50 (0) 0/71 (0)
Stroke 0/50 (0) 2/71 (2.8)
Bleeding complications 4/50 (8.0) 2/71 (2.8)
Vascular complications 2/50 (4) 2/71 (2.8)
Transfusions 28/50 (56) 17/71 (23.9)
Acute kidney injury 3/50 (6) 2/71 (2.8)
Pacemaker implantation 5/50 (10) 4/71 (5.6)
30‐day all‐cause mortality 4/50 (8) 3/71 (4.2)
Cardiac mortality 3/50 (6) 3/71 (4.2)
Composite safety 7/50 (14) 7/71 (9.9)
Bijuklic et al20 2015 SAPIEN XT and SAPIEN 3, transapical 30 days VARC‐2 Device success 54/55 (98.2) 30/32 (93.5)
Postdilation 3/55 (5.5) 1/32 (3.1)
Moderate PVL 1/55 (1.8) 2/32 (6.5)
Myocardial infarction 0/55 (0) 0/32 (0)
Stroke 3/58 (5.2) 1/33 (3.0)
30‐day all‐cause mortality 0/55 (0) 2/32 (2.8)

Values are expressed as the occurrence of an event or sample size and (%). VARC‐2 definitions: Device success indicates absence of procedural mortality, correct positioning of a single prosthetic heart valve into the proper anatomical position, intended performance of the prosthetic heart valve (no prosthesis–patient mismatch and mean aortic valve gradient <20 mm Hg or peak velocity <3 m/s and no moderate or severe prosthetic valve regurgitation). Early safety at 30 days indicates all‐cause mortality (at 30 days), all stroke (disabling and nondisabling), life‐threatening bleeding, acute kidney injury stage 2 or 3 (including renal replacement therapy), coronary artery obstruction requiring intervention, major vascular complication, valve‐related dysfunction requiring repeat procedure (BAV, TAVI or surgical aortic replacement). AR indicates aortic regurgitation; BAV, balloon aortic valvuloplasty; NA, not available; PVL, paravalvular leakage; TIA, transient ischemic attack; VARC‐2, Valve Academic Research Consortium.

#Bailout BAV predilation due to difficulties in crossing the aortic valve.

*P=0.014, **P=0.02, P=0.09, § P=0.078, §§ P=0.056, &ddagger; P=0.049.

Median time of 429 days.

P<0.001, P=0.03, ∫∫ P=0.018.

Table 4.

Pooled Analysis for Adverse Outcomes Without and With Preimplantation BVA According to Valve Type

Outcome Studies Cumulative % Studies Edwards SAPIEN XT or SAPIEN 3 % Studies Medtronic CoreValve %
Device success 16 1311/1395 94 10 823/876 94 6 488/519 94
Postdilation 14 210/1177 18 9 118/864 14 5 92/313 29
Need for second valve 7 37/719 5 4 18/481 4 3 19/238 8
Conversion to surgery 4 14/460 3 2 12/349 3 2 2/111 2
Moderate or severe AR/PVL 9 124/757 16 4 9/262 3 5 115/495 23
Mild AR/PVL 3 19/335 6 3 19/335 6 NA NA NA
Stroke/TIA 12 28/1014 3 7 24/701 3 5 4/313 1
Myocardial infarction 8 1/622 0.2 4 0/360 0 4 1/262 0.4
Major or life‐threatening bleeding 6 17/409 4 4 12/285 4 2 5/124 4
Annulus rupture 2 2/173 1 2 2/173 1 NA NA NA
Cardiac tamponade 3 11/313 4 1 1/56 2 2 10/257 4
Acute kidney injury 7 74/641 12 5 13/335 4 2 61/306 20
Pacemaker implantation 12 117/983 12 7 60/670 9 5 57/313 18
Major vascular complications 6 26/412 6 2 6/177 3 4 20/235 9
Minor vascular complications 2 21/124 17 NA NA NA 2 21/124 17
Safety composite end point 6 111/537 21 4 91/386 24 2 20/151 13
Mortality 15 72/1282 6 9 49/763 6 6 23/519 4

AR indicates aortic regurgitation; BAV, balloon aortic valvuloplasty; NA, not available; PVL, paravalvular leakage; TIA, transient ischemic attack.

Table 5.

Analysis for Adverse Outcomes Without Preimplantation BAV According to Valve Type

Outcome Studies Cumulative % Studies Edwards SAPIEN XT or SAPIEN 3 % Studies Medtronic CoreValve %
Device success 16 691/721 96 10 380/396 96 6 311/325 96
Postdilation 14 112/636 18 9 45/384 12 5 67/252 27
Need for second valve 7 23/388 6 4 6/195 3 3 17/193 9
Conversion to surgery 4 5/240 2 2 3/129 2 2 2/111 2
Moderate or severe AR/PVL 9 57/456 13 4 4/139 3 5 53/317 17
Mild AR/PVL 3 10/125 8 3 10/125 8 NA NA NA
Stroke/TIA 12 14/564 2 7 10/312 3 5 4/252 2
Myocardial infarction 8 0/382 0 4 0/181 0 4 0/201 0
Major or life‐threatening bleeding 6 11/201 5 4 7/138 5 2 4/63 6
Annulus rupture 2 0/76 0 2 0/76 0 NA NA NA
Cardiac tamponade 3 8/150 5 1 1/26 4 2 7/124 2
Acute kidney injury 7 26/286 9 5 9/158 6 2 17/128 13
Pacemaker implantation 12 68/535 13 7 22/283 8 5 46/252 18
Major vascular complications 6 17/250 7 2 4/76 5 4 13/174 7
Minor vascular complications 2 5/63 8 NA NA NA 2 5/63 8
Safety composite end point 6 52/284 18 4 36/178 20 2 16/106 15
Mortality 15 27/669 4 9 11/344 3 6 16/325 5

AR indicates aortic regurgitation; BAV, balloon aortic valvuloplasty; NA, not available; PVL, paravalvular leakage; TIA, transient ischemic attack.

Table 6.

Analysis for Adverse Outcomes With Preimplantation BAV According to Valve Type

Outcome Studies Cumulative % Studies Edwards SAPIEN XT or SAPIEN 3 % Studies Medtronic CoreValve %
Device success 11 620/674 92 8 443/480 92 3 177/194 91
Postdilation 10 98/541 18 8 73/480 15 2 25/61 41
Need for second valve 5 14/331 4 4 12/286 4 1 2/45 4
Conversion to surgery 2 9/220 4 2 9/220 4 NA NA NA
Moderate or severe AR/PVL 5 67/301 22 3 5/123 4 2 62/178 35
Mild AR/PVL 2 9/210 4 2 9/210 4 NA NA NA
Stroke/TIA 8 14/450 3 6 14/389 4 2 0/61 0
Myocardial infarction 6 1/240 0.4 4 0/179 0 2 1/61 2
Major or life‐threatening bleeding 5 6/208 3 3 5/147 3 2 1/61 2
Annulus rupture 2 2/97 2 2 2/97 2 NA NA NA
Cardiac tamponade 2 3/163 2 1 0/30 0 1 3/133 2
Acute kidney injury 6 48/355 14 4 4/177 2 2 44/178 25
Pacemaker implantation 8 49/448 11 6 38/387 10 2 11/61 18
Major vascular complications 4 9/162 6 2 2/101 2 2 7/61 6
Minor vascular complications 2 16/61 26 NA NA NA 2 16/61 26
Safety composite end point 5 59/253 23 4 55/208 26 1 4/45 9
Mortality 10 45/613 7 7 38/419 9 3 7/194 4

AR indicates aortic regurgitation; BAV, balloon aortic valvuloplasty; NA, not available; PVL, paravalvular leakage; TIA, transient ischemic attack.

In‐Hospital and 30‐Day Outcomes

Crude device success rate was reported in all studies5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20 and achieved in 94% (1311 of 1395) of patients without differences between valve types. Crude all‐cause mortality at 30 days was reported in 15 studies5, 6, 7, 8, 9, 10, 11, 13, 14, 15, 16, 17, 18, 19, 20 and occurred in 6% (72 of 1282) of patients. The safety composite end point was reported in 6 studies7, 9, 11, 12, 18, 19 and occurred in 21% (111 of 537) of patients. The crude incidence of residual moderate or severe aortic regurgitation or PVL was reported in 9 studies5, 6, 7, 8, 9, 12, 13, 14 and occurred in 16% (124 of 757) of patients. In this regard, 4 studies used the balloon‐expandable valve6, 12, 14, 20 with a 3% rate (9 of 262 patients), and 5 studies used the self‐expandable valve5, 7, 8, 9, 13 with a 23% rate (115 of 495 patients). Of note, the need for postimplantation postdilation was reported in 145, 6, 7, 8, 9, 11, 12, 13, 14, 15, 16, 17, 18, 19 studies and occurred in 18% (210 of 1177) of patients; 9 studies used the balloon‐expandable valve6, 11, 12, 13, 14, 16, 17, 18, 19 with a 14% rate (118 of 864 patients), and 6 studies used the self‐expandable valve5, 7, 8, 9, 13, 15 with a 29% rate (92 of 313 patients). The crude cerebrovascular events, including stroke or transient ischemic attack, were reported in 12 studies5, 7, 8, 9, 10, 11, 15, 16, 17, 18, 19, 20 and occurred in 3% (28/1014) of patients; 7 studies used the balloon‐expandable valve10, 11, 16, 17, 18, 19, 20 with a 3% rate (24 of 701 patients), and 5 studies used the self‐expandable valve5, 7, 8, 9, 15 with a 1% rate (4 of 313 patients). The need for permanent pacemaker implantation was reported in 12 studies5, 7, 8, 9, 10, 11, 14, 15, 16, 17, 18, 19 and occurred in 12% (117 of 983) of patients; 7 studies used the balloon‐expandable valve10, 11, 14, 16, 17, 18, 19 with a 9% rate (60 of 670 patients), and 5 studies used the self‐expandable valve5, 7, 8, 9, 15 with an 18% rate (57 of 313 patients).

Importantly, meta‐analyses evaluating outcomes using strategies with and without preimplantation BAV showed no statistically significant differences. Notably, device success (RR 1.02, 95% CI 0.98–1.06, P=0.24), mortality (RR 0.61, 95% CI 0.32–1.14, P=0.12), safety composite end point (RR 0.85, 95% CI 0.62–1.18, P=0.34), moderate to severe PVL (RR 0.68, 95% CI 0.23–1.99, P=0.48), need for postimplantation postdilation (RR 0.86, 95% CI 0.66–1.13, P=0.28), stroke or transient ischemic attack (RR 0.72, 95% CI 0.30–1.71, P=0.45), permanent pacemaker implantation (RR 0.80, 95% CI 0.49–1.30, P=0.37), or acute kidney injury (RR 1.10, 95% CI 0.49–2.45, P=0.82). The remaining outcomes are shown in Tables 4, 5 through 6.

Sensitivity Analysis

We conducted a sensitivity analysis for clinical outcomes with and without preimplantation BAV according to the different access sites, comparing the transfemoral with transapical and transfemoral or any other access including the direct aortic and trans‐subclavian routes (Table 7, Figures 2, 3 through 4). Those who underwent TAVI without preimplantation BAV and with the transfemoral or any other access were marginally associated with more cardiac tamponade (RR 3.61, 95% CI 1.04–12.56, P=0.04). Studies including the transfemoral access only were associated with higher mortality among patients who underwent TAVI with preimplantation BAV (RR 0.30, 95% CI 0.11–0.82, P=0.02); however, this difference disappeared when analyzed as a whole access‐site sample (RR 0.61, 95% CI 0.32–1.14, P=0.12).

Table 7.

Sensitivity Analysis With Risk of Outcomes Without or With Preimplantation BAV According to Access Site

Outcome or Subgroup Studies Patients Relative Risk (95% CI)
Device success 11 1188 1.02 (0.98–1.06)
Transfemoral 5 557 1.01 (0.97–1.04)
Transapical 2 180 1.04 (0.90–1.19)
Transfemoral or any other access 4 451 1.09 (0.87–1.36)
Postdilation 10 982 0.86 (0.66–1.13)
Transfemoral 5 557 0.95 (0.58–1.56)
Transapical 2 180 0.99 (0.35–2.78)
Transfemoral or any other access 3 245 0.87 (0.53–1.43)
Need for a second valve 5 581 0.82 (0.34–1.98)
Transfemoral 2 301 0.76 (0.24–2.42)
Transapical 2 180 1.00 (0.14–6.94)
Transfemoral or any other access 1 100 0.82 (0.12–5.58)
Conversion to surgery 2 349 0.69 (0.16–2.89)
Transfemoral 1 249 0.48 (0.11–2.16)
Transapical 1 100 3.00 (0.13–71.92)
Moderate or severe AR/PVL 4 506 0.68 (0.23–1.99)
Transfemoral 2 200 0.77 (0.21–2.82)
Transfemoral or any other access 2 306 0.65 (0.13–3.39)
Mild AR/PVL 2 329 1.19 (0.44–3.19)
Transfemoral 1 249 1.08 (0.28–4.19)
Transapical 1 80 1.33 (0.32–5.58)
Stroke/TIA 6 689 0.72 (0.30–1.71)
Transfemoral 3 388 0.87 (0.24–3.23)
Transapical 2 180 0.70 (0.20–2.49)
Transfemoral or any other access 1 121 0.28 (0.01–5.76)
Myocardial infarction 1 24 0.63 (0.03–13.93)
Transfemoral or any other access 1 24 0.63 (0.03–13.93)
Major or life‐threatening bleeding 5 397 1.98 (0.76–5.18)
Transfemoral 1 52 1.00 (0.15–6.57)
Transapical 1 100 1.00 (0.06–15.55)
Transfemoral or any other access 3 245 3.03 (0.89–10.28)
Annulus rupture 2 173 0.40 (0.04–3.72)
Transfemoral 1 52 0.33 (0.01–7.82)
Transfemoral or any other access 1 121 0.47 (0.02–11.32)
Cardiac tamponade 2 262 3.61 (1.04–12.56)
Transfemoral 1 56 3.44 (0.15–81.09)
Transfemoral or any other access 1 206 3.64 (0.94–14.14)
Acute kidney injury 6 635 1.10 (0.49–2.45)
Transfemoral 2 108 5.05 (0.59–43.03)
Transapical 1 100 0.50 (0.05–5.34)
Transfemoral or any other access 3 427 0.98 (0.37–2.58)
Pacemaker implantation 8 782 0.80 (0.49–1.30)
Transfemoral 3 357 0.79 (0.29–2.17)
Transapical 2 180 1.02 (0.34–3.09)
Transfemoral or any other access 3 245 0.85 (0.32–2.25)
Major vascular complications 4 301 1.15 (0.45–2.99)
Transfemoral 1 56 5.74 (0.29–114.41)
Transfemoral or any other access 3 245 0.96 (0.35–2.63)
Minor vascular complications 2 124 0.38 (0.03–4.92)
Transfemoral or any other access 2 124 0.38 (0.03–4.92)
Safety composite end point 4 434 0.85 (0.62–1.18)
Transfemoral 1 113 0.68 (0.44–1.07)
Transapical 1 100 0.58 (0.25–1.36)
Transfemoral or any other access 2 221 1.02 (0.66–1.58)
Mortality 10 1075 0.61 (0.32–1.14)
Transfemoral 4 357 0.30 (0.11–0.82)
Transapical 2 180 0.38 (0.10–1.37)
Transfemoral or any other access 4 451 1.38 (0.58–3.32)

Any other access, trans‐subclavian or direct aortic. AR indicates aortic regurgitation; BAV, balloon aortic valvuloplasty; PVL, paravalvular leakage; TIA, transient ischemic attack.

Figure 2.

Figure 2

Meta‐analyses evaluating (A) device success, (B) mortality, (C) safety composite end point, (D) need for a second valve, (E) postdilation, and (F) major or life‐threatening bleeding for patients with and without preimplantation BAV, according to access site. BAV indicates balloon aortic valvuloplasty; M‐H, Mantel–Haenszel.

Figure 3.

Figure 3

Meta‐analyses evaluating the risk of (A) annulus rupture, (B) cardiac tamponade, (C) conversion to surgery, (D) major vascular complications, (E) stroke or transient ischemic attack, and (F) acute kidney injury for patients with and without preimplantation BAV, according to access site. BAV indicates balloon aortic valvuloplasty; M‐H, Mantel–Haenszel.

Figure 4.

Figure 4

Meta‐analyses evaluating the risk of (A) moderate to severe paravalvular leakage, (B) pacemaker implantation, (C) minor vascular compilations, and (D) myocardial infarction for patients with and without preimplantation BAV, according to access site. BAV indicates balloon aortic valvuloplasty; M‐H, Mantel–Haenszel.

We also performed sensitivity analysis according to valve type (Table 8, Figures 5, 6 through 7). The self‐expandable valve tended to be associated with more cardiac tamponade (RR 3.64, 95% CI 0.94–14.14, P=0.06) when the procedure was performed without preimplantation BAV and became significant when analyzed with the whole sample for type of valve (RR 3.61, 95% CI 1.04–12.56, P=0.04).

Table 8.

Sensitivity Analysis With Risk of Outcomes Without or With Preimplantation BAV According to Valve Type

Outcome or Subgroup Studies Patients Relative Risk (95% CI)
Device success 10 1101 1.02 (0.98–1.07)
SAPIEN 7 609 1.01 (0.98–1.04)
CoreValve 3 330 1.11 (0.69–1.78)
Postdilation 9 733 0.84 (0.62–1.14)
SAPIEN 7 609 0.92 (0.60–1.40)
CoreValve 2 124 1.17 (0.28–4.82)
Need for a second valve 4 332 0.92 (0.27–3.12)
SAPIEN 3 232 1.00 (0.21–4.84)
CoreValve 1 100 0.82 (0.12–5.58)
Conversion to surgery 1 100 3.00 (0.13–71.92)
SAPIEN 1 100 3.00 (0.13–71.92)
Moderate or severe AR/PVL 4 506 0.68 (0.23–1.99)
SAPIEN 2 200 0.77 (0.21–2.82)
CoreValve 2 306 0.65 (0.13–3.39)
Mild AR/PVL 1 80 1.33 (0.32–5.58)
SAPIEN 1 80 1.33 (0.32–5.58)
Stroke/TIA 5 440 0.72 (0.28–1.84)
SAPIEN 5 440 0.72 (0.28–1.84)
Myocardial infarction 1 24 0.63 (0.03–13.93)
CoreValve 1 24 0.63 (0.03–13.93)
Major or life‐threatening bleeding 5 397 1.98 (0.76–5.18)
SAPIEN 3 273 1.63 (0.52–5.06)
CoreValve 2 124 3.27 (0.53–19.93)
Annulus rupture 2 173 0.40 (0.04–3.72)
SAPIEN 2 173 0.40 (0.04–3.72)
Cardiac tamponade 2 262 3.61 (1.04–12.56)
SAPIEN 1 56 3.44 (0.15–81.09)
CoreValve 1 206 3.64 (0.94–14.14)
Acute kidney injury 6 635 1.10 (0.49–2.45)
SAPIEN 4 329 1.93 (0.60–6.27)
CoreValve 2 306 0.79 (0.26–2.41)
Pacemaker implantation 7 533 0.98 (0.56–1.72)
SAPIEN 5 409 1.30 (0.66–2.57)
CoreValve 2 124 0.56 (0.20–1.56)
Major vascular complications 4 301 1.15 (0.45–2.99)
SAPIEN 2 177 2.14 (0.42–10.80)
CoreValve 2 124 0.83 (0.26–2.70)
Minor vascular complications 2 124 0.38 (0.03–4.92)
CoreValve 2 124 0.38 (0.03–4.92)
Safety composite end point 4 434 0.85 (0.62–1.18)
SAPIEN 3 334 0.79 (0.52–1.20)
CoreValve 1 100 1.64 (0.53–5.08)
Mortality 9 826 0.78 (0.41–1.48)
SAPIEN 6 496 0.52 (0.28–1.40)
CoreValve 3 330 1.15 (0.38–3.47)

SAPIEN includes SAPIEN XT and SAPIEN 3 valves. AR indicates aortic regurgitation; BAV, balloon aortic valvuloplasty; PVL, paravalvular leakage; TIA, transient ischemic attack.

Figure 5.

Figure 5

Meta‐analyses evaluating (A) device success, (B) mortality, (C) safety composite end point, (D) need for a second valve, (E) postdilation, and (F) major or life‐threatening bleeding for patients with and without preimplantation BAV, according to valve type. BAV indicates balloon aortic valvuloplasty; M‐H, Mantel–Haenszel.

Figure 6.

Figure 6

Meta‐analyses evaluating the risk of (A) cardiac tamponade, (B) annulus rupture, (C) conversion to surgery, (D) stroke or transient ischemic attack, (E) major vascular complications, and (F) acute kidney injury for patients with and without preimplantation BAV, according to valve type. BAV indicates balloon aortic valvuloplasty; M‐H, Mantel–Haenszel.

Figure 7.

Figure 7

Meta‐analyses evaluating the risk of (A) moderate to severe paravalvular leakage, (B) pacemaker implantation, (C) minor vascular compilations, and (D) myocardial infarction for patients with and without preimplantation BAV, according to valve type. BAV indicates balloon aortic valvuloplasty; M‐H, Mantel–Haenszel.

No significant differences were found between the different access sites and valve types among the remaining analyzed variables. Importantly, neither the access site nor the valve type affected device success rate, safety composite end point, or mortality (Tables 7 and 8).

Discussion

The results of this meta‐analysis show no significant differences between patients undergoing TAVI either with or without preimplantation BAV with respect to mortality, neurological events, permanent pacemaker implantation, or improvement in device success (including repeat procedure, significant residual PVL or aortic regurgitation, and the need for postimplantation postdilation).

Rationale and Adjunctive Utilities of Preimplantation BAV During TAVI

The pathophysiology of aortic stenosis and calcification make it reasonable to hypothesize that crossing the heavily calcified valve by the transapical antegrade approach would not require predilation.6, 11, 16, 19 In contrast, in transfemoral or other retrograde procedures, preimplantation BAV remains important to ensure smooth crossing of the TAVI delivery system.

Notably, our results show more cardiac tamponade without BAV, although one may be cautious in interpreting results based on only 2 studies.13, 14 Forceful pushing of the device and movement of the stiff wire inside the ventricle might cause this issue. Importantly, even if the valve is successfully crossed with the TAVI system, failure to fully expand the transcatheter valve may translate into hemodynamic instability due to leaflet incompetence, significant PVL, valve migration, or further need for postdilation with inherent risk of valve migration.5, 9, 21 In fact, some studies reported the need for bailout BAV predilation when TAVI was initially planned without preimplantation BAV.7, 8, 9, 21 Moreover, a partial balloon‐tip inflation technique was reported to facilitate crossing of the aortic valve.10, 12

Coronary ostia <10 to 11 mm from the aortic annulus represent a hazard for coronary obstruction,22, 23 especially in narrow, tubular, or porcelain aortic roots exhibiting longitudinal remodeling.22, 24 In these cases, simultaneous aortogram at the time of BAV is helpful to assess the behavior of the heavily calcified aortic leaflets, especially the left leaflet toward the left main coronary artery.9, 22 Finally, performing preimplantation BAV also allows confirmation of reliable pacing‐wire capture. In the case of capture failure, albeit rare, it is preferable to deal with this issue during BAV rather than during balloon‐expandable valve deployment.

Residual Aortic Regurgitation and PVL

It is well known that the incidence of PVL is associated with worse short‐ and long‐term outcomes.25, 26, 27 Our results show a higher pooled incidence of PVL with the self‐expanding valve compared with the balloon‐expandable valve, and these percentages remained much higher even if analyzing groups with and without preimplantation BAV separately. Indeed, these results are in line with previously reported evidence.27, 28 Interestingly, Fiorina and colleagues9 reported lower incidence of moderate to severe PVL without preimplantation BAV; however, hemodynamics were not statistically different between the 2 strategies, as assessed by aortic regurgitation index, likely due to low incidence of severe PVL. It is quite provocative to suggest that performing TAVI without preimplantation BAV may reduce PVL, mostly using the self‐expandable valve because of its delivery mechanism, composed of a self‐expanding nitinol frame. Regarding the balloon‐expandable bioprosthesis, PVL reduction might have been related to better understanding of valve sizing (and slight oversizing) that progressed along the same learning curve and led to confidence in direct implantation. In addition, some studies included the SAPIEN 3 bioprosthesis, which includes a specific anti‐PVL sealing design.

Need for Postimplantation Postdilation

According to our results, the self‐expanding valve was associated with a crude 2‐fold greater need for postdilation. Importantly, postimplantation postdilation can also cause device migration and thus increase PVL9 as well as the risk for annular rupture with postdilation than with predilation. Although avoiding BAV minimizes manipulation of the severely calcified aortic annulus or native valve, it must be balanced with the potential need for more postdilation to correct a significant residual PVL. Furthermore, the impact of postdilation on the long‐term valve outcome remains unknown.

Aortic Valve Calcification Assessment to Plan TAVI Without Preimplantation BAV

The degree and distribution of aortic valve calcification and annular morphology has been correlated with postprocedural PVL.29, 30, 31, 32 Moreover, the location and/or asymmetry of this calcification, more often located at the noncoronary cusp and/or device landing zone, is more important than the total calcium load.20, 29, 31 Interestingly, Mollmann and colleagues14 showed no differences in the extent of valve calcification, as assessed by Agatston score, among patients treated with the 2 strategies. In addition, they found no correlation between the aortic valve area and load of calcification with the duration of the procedure, fluoroscopy time, radiation dose, or contrast amount. Similarly, Fiorina et al9 found no correlation between residual PVL and the degree of calcification in the device landing zone among those who received TAVI without preimplantation BAV. Of note, the authors also reported that among patients who received preimplantation BAV, bigger prosthesis size indicated higher incidence of significant PVL, although that relationship was not observed in patients in which TAVI was undertaken without preimplantation BAV.9

Islas and colleagues17 reported favorable and unfavorable features relevant to the decision to perform TAVI without preimplantation BAV using 3‐dimentional transesophageal echocardiography. Notably, unfavorable features included heavy or severe aortic valve calcification, defined as leaflet thickness >5 mm with large nodules and diffuse calcification of the aortic annulus; an asymmetric and bulky calcification distribution; valve area <0.4 cm2 with an eccentric and/or irregular orifice; moderately or severely restricted mobility; presence of calcification nodules at the left ventricle outflow tract or close to coronary ostia; and moderate aortic regurgitation. In this regard, Bijuklic et al20 also reported that in cases of severe asymmetric aortic valve calcification or a tight aortic effective orifice area (planimetry ≤0.5 cm2), as assessed by intraprocedural transesophageal echocardiography, preimplantation BAV was performed even if the newest generation lower profile Edwards SAPIEN 3 valve was available.

Neurological Events

It has been hypothesized that TAVI without preimplantation BAV may be associated with fewer embolic events, especially fewer cerebrovascular accidents. Strikingly, relatively low stroke rates have been reported with the 2 strategies and the 2 TAVI devices. The different technique by which the balloon‐expandable valve is deployed, more often oversized, compared with the self‐expandable valve (less aggressive expansion technique) may explain the higher potential for calcific embolization. In this regard, the new‐generation balloon‐expandable Edwards SAPIEN 3 valve requires less overexpansion compared with the SAPIEN XT; however, most of the analyzed studies failed to support avoiding a preimplantation BAV strategy with reduced neurological complications. Moreover, Aggarwal and colleagues12 reported no differences between groups in terms of embolic load based on transcranial Doppler, including number in solid, gaseous, or total emboli (P>0.05 for all). In addition, Bijuklic et al20 showed no difference in terms of silent embolic events assessed by diffusion‐weighted cerebral magnetic resonance. Interestingly, a large volume was observed among those undergoing TAVI without preimplantation BAV. Importantly, the authors reported that 4 patients experienced stroke, 3 of them without preimplantation BAV and 1 patient with preimplantation BAV. Nonetheless, because of the exclusion criteria stated in the methodology, these patients were excluded from analysis because of a clinically apparent stroke within 3 days after TAVI.20

Potential Benefits of TAVI Without Preimplantation BAV

Preimplantation BAV might be poorly tolerated by certain patients. The time between BAV predilation and TAVI is a particularly crucial period, especially in patients with preexisting severe left ventricular systolic dysfunction and/or pulmonary hypertension. Moreover, the temporary interruption in ventricular output during rapid ventricular pacing and BAV outflow occlusion itself can result in hemodynamic compromise. Furthermore, significant aortic regurgitation following BAV can precipitate clinically important instability, even in patients with normal left ventricular function; this hemodynamic deterioration can be sudden, profound, and not entirely predictable. The special subset of patients presenting with and/or prone to hemodynamic instability can experience multiorgan hypoperfusion, mainly cerebral and renal; therefore, avoiding a rapid pacing run for BAV may prevent an unnecessary period of hypotension in certain cases.

Alternatively, it is logical that performing TAVI without preimplantation BAV is associated with a reduction in contrast volume,6, 11, 14, 18, 20 fluoroscopy time,12, 16, 18 radiation dose,14 or total procedural time.6, 17, 20 The clinical impact of these differences is uncertain.

Limitations

The present study has several limitations. The main limitation lies with the small number of patients within each study and the nonrandomized nature of the included studies that may introduce selection bias. Importantly, the decision of whether or not to predilate was made at the discretion of the TAVI team operator and may relate to the complexity of the valve anatomy and the operator's perception of successful valve delivery; therefore, it is possible that BAV was undertaken in more complex and challenging cases, subjecting comparison of outcomes to selection bias. In addition, patient‐level data were not available for this analysis, precluding more robust adjustment for any differences in clinical or anatomical variables. Nevertheless, in studies that reported clinical demographics and anatomical features of the patients, these variables were relatively well matched in both BAV/non‐BAV studied cohorts. Notably, many of the studies included in this analysis lacked data on whether patients had hemodynamic compromise and/or poor left ventricle function necessitating BAV prior to the index TAVI procedure (bridge to TAVI). Finally, patients exhibiting major comorbidities and clinically uncertain benefit from TAVI may have been offered BAV as a potential bridge or palliation due to an adverse profile, with subsequent definitive treatment (TAVI) offered after substantial improvement.

Conclusion

Our analysis suggests that TAVI procedures with or without preimplantation BAV were associated with similar outcomes for a number of clinically relevant end points. Further studies including large number of patients are needed to ascertain the impact of TAVI without preimplantation BAV as a standard practice. Meanwhile, our findings provide real‐world data that may contribute to the current practice of TAVI operators and influence future perspectives. Notably, a simplified procedure can be safely performed and achieve comparable results.

Sources of Funding

Supported in part by a Program of Experimental Medicine (POEM) Research Award, Department of Medicine, Western University.

Disclosures

None.

(J Am Heart Assoc. 2016;5:e003191 doi: 10.1161/JAHA.115.003191)

References

  • 1. Mack MJ, Leon MB, Smith CR, Miller DC, Moses JW, Tuzcu EM, Webb JG, Douglas PS, Anderson WN, Blackstone EH, Kodali SK, Makkar RR, Fontana GP, Kapadia S, Bavaria J, Hahn RT, Thourani VH, Babaliaros V, Pichard A, Herrmann HC, Brown DL, Williams M, Akin J, Davidson MJ, Svensson LG; PARTNER 1 trial investigators . 5‐year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet. 2015;385:2477–2484. [DOI] [PubMed] [Google Scholar]
  • 2. Kapadia SR, Leon MB, Makkar RR, Tuzcu EM, Svensson LG, Kodali S, Webb JG, Mack MJ, Douglas PS, Thourani VH, Babaliaros VC, Herrmann HC, Szeto WY, Pichard AD, Williams MR, Fontana GP, Miller DC, Anderson WN, Akin JJ, Davidson MJ, Smith CR; PARTNER 1 trial investigators . 5‐year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet. 2015;385:2485–2491. [DOI] [PubMed] [Google Scholar]
  • 3. Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodes‐Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium‐2 consensus document. J Am Coll Cardiol. 2012;60:1438–1454. [DOI] [PubMed] [Google Scholar]
  • 4. Ioannidis JP, Trikalinos TA. The appropriateness of asymmetry tests for publication bias in meta‐analyses: a large survey. CMAJ. 2007;176:1091–1096. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Grube E, Naber C, Abizaid A, Sousa E, Mendiz O, Lemos P, Kalil Filho R, Mangione J, Buellesfeld L. Feasibility of transcatheter aortic valve implantation without balloon pre‐dilation: a pilot study. JACC Cardiovasc Interv. 2011;4:751–757. [DOI] [PubMed] [Google Scholar]
  • 6. Wendler O, Dworakowski R, Monaghan M, MacCarthy PA. Direct transapical aortic valve implantation: a modified transcatheter approach avoiding balloon predilatation. Eur J Cardiothorac Surg. 2012;42:734–736. [DOI] [PubMed] [Google Scholar]
  • 7. Mendiz OA, Fraguas H, Lev GA, Valdivieso LR, Favaloro RR. Transcatheter aortic valve implantation without balloon predilation: a single‐center pilot experience. Catheter Cardiovasc Interv. 2013;82:292–297. [DOI] [PubMed] [Google Scholar]
  • 8. Rück A, Yamasaki K, Meduri C, Settergren M. Safe and feasible: 78 consecutive cases of TAVI without predilatation. EuroIntervention. 2013; London Valves Abstracts. Available at: http://www.pcronline.com/eurointervention/AbstractsLondon2013_issue/2023/. Accessed May 26, 2016. [Google Scholar]
  • 9. Fiorina C, Maffeo D, Curello S, Lipartiti F, Chizzola G, D'Aloia A, Adamo M, Mastropierro R, Gavazzi E, Ciccarese C, Chiari E, Ettori F. Direct transcatheter aortic valve implantation with self‐expandable bioprosthesis: feasibility and safety. Cardiovasc Revasc Med. 2014;15:200–203. [DOI] [PubMed] [Google Scholar]
  • 10. Davies WR, Bapat VN, Hancock JE, Young CP, Redwood SR, Thomas MR. Direct TAVI using a balloon‐expandable system: a novel technique to eliminate pre‐deployment balloon aortic valvuloplasty. EuroIntervention. 2014;10:248–252. [DOI] [PubMed] [Google Scholar]
  • 11. Conradi L, Seiffert M, Schirmer J, Koschyk D, Blankenberg S, Reichenspurner H, Diemert P, Treede H. Transapical transcatheter aortic valve implantation without prior balloon aortic valvuloplasty: feasible and safe. Eur J Cardiothorac Surg. 2014;46:61–66. [DOI] [PubMed] [Google Scholar]
  • 12. Aggarwal SK, Delahunty N, Early S, Ako E, Cheang M‐H, Reinthaler M, Tamimi AN, Wong B, Roberts N, Yap J, Ozkor M. Balloon‐expandable transcatheter aortic valves can be effectively and safely implanted transfemorally without balloon valvuloplasty. J Am Coll Cardiol. 2014;64(11_S):B222. doi: 10.1016/j.jacc.2014.1007.1833. [DOI] [PubMed] [Google Scholar]
  • 13. Giustino G, Montorfano M, Latib A, Panoulas VF, Chieffo A, Spatuzza P, Fuertes Ferre G, Agricola E, Spagnolo P, Covello RD, Alfieri O, Colombo A. To predilate or to not predilate in transcatheter aortic valve implantation? Single‐center experience with self‐expandable corevalve revalving system. J Am Coll Cardiol. 2014;64(11_S):853. doi: 10.1016/j.jacc.2014.1007.1815. [Google Scholar]
  • 14. Mollmann H, Kim WK, Kempfert J, Blumenstein J, Liebetrau C, Nef H, Van Linden A, Walther T, Hamm C. Transfemoral aortic valve implantation of Edwards SAPIEN XT without predilatation is feasible. Clin Cardiol. 2014;37:667–671. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Kochman J, Koltowski L, Huczek Z, Scislo P, Bakon L, Wilimski R, Rymuza B, Opolski G. Direct transcatheter aortic valve implantation—one‐year outcome of a case control study. Postepy Kardiol Interwencyjnej. 2014;10:250–257. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Kempfert J, Meyer A, Kim WK, van Linden A, Arsalan M, Blumenstein J, Mollmann H, Walther T. First experience without pre‐ballooning in transapical aortic valve implantation: a propensity score‐matched analysis. Eur J Cardiothorac Surg. 2015;47:31–38. [DOI] [PubMed] [Google Scholar]
  • 17. Islas F, Almeria C, Garcia‐Fernandez E, Jimenez P, Nombela‐Franco L, Olmos C, Marcos‐Alberca P, Cuadrado A, Fernandez‐Ortiz A, Macaya C, Perez de Isla L. Usefulness of echocardiographic criteria for transcatheter aortic valve implantation without balloon predilation: a single‐center experience. J Am Soc Echocardiogr. 2015;28:423–429. [DOI] [PubMed] [Google Scholar]
  • 18. Conradi L, Schaefer A, Seiffert M, Schirmer J, Schaefer U, Schon G, Blankenberg S, Reichenspurner H, Treede H, Diemert P. Transfemoral TAVI without pre‐dilatation using balloon‐expandable devices: a case‐matched analysis. Clin Res Cardiol. 2015;104:735–742. [DOI] [PubMed] [Google Scholar]
  • 19. Wong SC, Pawar S, Minutello RM, Horn EM, Skubas NJ, Devereux RB, Salemi A. Device success and 30‐day clinical outcome in patients undergoing preimplant valvuloplasty in transfemoral versus omitting valvuloplasty in transapical transcatheter aortic valve replacement. J Thorac Cardiovasc Surg. 2015;150:1111–1117. [DOI] [PubMed] [Google Scholar]
  • 20. Bijuklic K, Haselbach T, Witt J, Krause K, Hansen L, Gehrckens R, Riess FC, Schofer J. Increased risk of cerebral embolization after implantation of a balloon‐expandable aortic valve without prior balloon valvuloplasty. JACC Cardiovasc Interv. 2015;8:1608–1613. [DOI] [PubMed] [Google Scholar]
  • 21. Chan PH, Mario CD, Moat N. Transcatheter aortic valve implantation without balloon predilatation: not always feasible. Catheter Cardiovasc Interv. 2013;82:328–332. [DOI] [PubMed] [Google Scholar]
  • 22. Kapadia SR, Svensson L, Tuzcu EM. Successful percutaneous management of left main trunk occlusion during percutaneous aortic valve replacement. Catheter Cardiovasc Interv. 2009;73:966–972. [DOI] [PubMed] [Google Scholar]
  • 23. Bagur R, Dumont E, Doyle D, Larose E, Lemieux J, Bergeron S, Bilodeau S, Bertrand OF, De Larochellière R, Rodés‐Cabau J. Coronary ostia stenosis after transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2010;3:253–255. [DOI] [PubMed] [Google Scholar]
  • 24. Akhtar M, Tuzcu EM, Kapadia SR, Svensson LG, Greenberg RK, Roselli EE, Halliburton S, Kurra V, Schoenhagen P, Sola S. Aortic root morphology in patients undergoing percutaneous aortic valve replacement: evidence of aortic root remodeling. J Thorac Cardiovasc Surg. 2009;137:950–956. [DOI] [PubMed] [Google Scholar]
  • 25. Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G, Klugmann S, Bedogni F, Maisano F, Marzocchi A, Poli A, Antoniucci D, Napodano M, De Carlo M, Fiorina C, Ussia GP. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation. 2011;123:299–308. [DOI] [PubMed] [Google Scholar]
  • 26. Abdel‐Wahab M, Zahn R, Horack M, Gerckens U, Schuler G, Sievert H, Eggebrecht H, Senges J, Richardt G. Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart. 2011;97:899–906. [DOI] [PubMed] [Google Scholar]
  • 27. Moat NE, Ludman P, de Belder MA, Bridgewater B, Cunningham AD, Young CP, Thomas M, Kovac J, Spyt T, Maccarthy PA, Wendler O, Hildick‐Smith D, Davies SW, Trivedi U, Blackman DJ, Levy RD, Brecker SJ, Baumbach A, Daniel T, Gray H, Mullen MJ. Long‐term outcomes after transcatheter aortic valve implantation in high‐risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry. J Am Coll Cardiol. 2011;58:2130–2138. [DOI] [PubMed] [Google Scholar]
  • 28. Abdel‐Wahab M, Mehilli J, Frerker C, Neumann FJ, Kurz T, Tolg R, Zachow D, Guerra E, Massberg S, Schafer U, El‐Mawardy M, Richardt G; Investigators C . Comparison of balloon‐expandable vs self‐expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA. 2014;311:1503–1514. [DOI] [PubMed] [Google Scholar]
  • 29. John D, Buellesfeld L, Yuecel S, Mueller R, Latsios G, Beucher H, Gerckens U, Grube E. Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self‐expanding CoreValve prosthesis. JACC Cardiovasc Interv. 2010;3:233–243. [DOI] [PubMed] [Google Scholar]
  • 30. Koos R, Mahnken AH, Dohmen G, Brehmer K, Gunther RW, Autschbach R, Marx N, Hoffmann R. Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol. 2011;150:142–145. [DOI] [PubMed] [Google Scholar]
  • 31. Ewe SH, Ng AC, Schuijf JD, van der Kley F, Colli A, Palmen M, de Weger A, Marsan NA, Holman ER, de Roos A, Schalij MJ, Bax JJ, Delgado V. Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation. Am J Cardiol. 2011;108:1470–1477. [DOI] [PubMed] [Google Scholar]
  • 32. Buellesfeld L, Stortecky S, Heg D, Gloekler S, Meier B, Wenaweser P, Windecker S. Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement. EuroIntervention. 2014;10:732–738. [DOI] [PubMed] [Google Scholar]