Abstract
The generation of aerosols and the contamination of surfaces arising from the use of a number of special purpose centrifuges have been measured. Except when sealed containers were used all the equipment tested generated airborne particles and contaminated surrounding surfaces. The magnitude of this contamination was shown to be associated with several factors, and it could be considerably reduced by the use of sealed containers, and by fitting air filters. The significance of these findings and their application are discussed.
Full text
PDF









Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bryan F. L., Ayres J. C., Kraft A. A. Salmonellae associated with further-processed turkey products. Appl Microbiol. 1968 Jan;16(1):1–9. doi: 10.1128/am.16.1.1-9.1968. [DOI] [PMC free article] [PubMed] [Google Scholar]
- CHATIGNY M. A. Protection against infection in the microbiological laboratory: devices and procedures. Adv Appl Microbiol. 1961;3:131–192. doi: 10.1016/s0065-2164(08)70509-4. [DOI] [PubMed] [Google Scholar]
- Howie J. W., Collins C. H. The Howie Code for preventing infection in clinical laboratories: comments on some general criticisms and specific complaints. Br Med J. 1980 Apr 19;280(6221):1071–1074. doi: 10.1136/bmj.280.6221.1071. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lauer J. L., VanDrunen N. A., Washburn J. W., Balfour H. H., Jr Transmission of hepatitis B virus in clinical laboratory areas. J Infect Dis. 1979 Oct;140(4):513–516. doi: 10.1093/infdis/140.4.513. [DOI] [PubMed] [Google Scholar]
- Newsom S. W., Matthews J. A microbiological survey of automated biochemical machines. J Clin Pathol. 1980 Jun;33(6):566–570. doi: 10.1136/jcp.33.6.566. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Petersen N. J., Bond W. W., Favero M. S. Air sampling for hepatitis B surface antigen in a dental operatory. J Am Dent Assoc. 1979 Sep;99(3):465–467. doi: 10.14219/jada.archive.1979.0326. [DOI] [PubMed] [Google Scholar]
- Stern E. L., Johnson J. W., Vesley D., Halbert M. M., Lawrence B. S., Williams L. E., Blume P. Aerosol production associated with clinical laboratory procedures. Am J Clin Pathol. 1974 Nov;62(5):591–600. doi: 10.1093/ajcp/62.5.591. [DOI] [PubMed] [Google Scholar]
- WEDUM A. G. Bacteriological safety. Am J Public Health Nations Health. 1953 Nov;43(11):1428–1437. doi: 10.2105/ajph.43.11.1428. [DOI] [PMC free article] [PubMed] [Google Scholar]