Skip to main content
Journal of Neurology, Neurosurgery, and Psychiatry logoLink to Journal of Neurology, Neurosurgery, and Psychiatry
. 1973 Aug;36(4):514–522. doi: 10.1136/jnnp.36.4.514

Measurement of extradural pressure and its relationship to other intracranial pressures

An experimental and clinical study

N J Coroneos 1,2, D G McDowall 1,2, R M Gibson 1,2, V W A Pickerodt 1,2, N P Keaney 1,2
PMCID: PMC494403  PMID: 4731325

Abstract

Disadvantages associated with the use of ventricular catheters for the prolonged measurement of intracranial pressure have resulted in the search for an alternative technique. Measurement of pressure from the extradural space is one such possibility, but widespread acceptance of this procedure has been limited by the technical difficulties associated with this measurement and lack of information on the relationship between cerebrospinal fluid and extradural pressures. A study to investigate this relationship and to develop a simple and effective technique for measuring extradural pressure is described.

Full text

PDF
514

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Coe J. E., Nelson W. J., Rudenberg F. H., Garza R. Technique for continuous intracranial pressure recording. Technical note. J Neurosurg. 1967 Oct;27(4):370–375. doi: 10.3171/jns.1967.27.4.0370. [DOI] [PubMed] [Google Scholar]
  2. HOPPENSTEIN R. A DEVICE FOR MEASURING INTRACRANIAL PRESSURE. Lancet. 1965 Jan 9;1(7376):90–91. doi: 10.1016/s0140-6736(65)91668-5. [DOI] [PubMed] [Google Scholar]
  3. Jacobson S. A., Rothballer A. B. Prolonged measurement of experimental intracranial pressure using a subminiature absolute pressure transducer. J Neurosurg. 1967 Jun;26(6):603–608. doi: 10.3171/jns.1967.26.6.0603. [DOI] [PubMed] [Google Scholar]
  4. Johnston I. H., Johnston J. A., Jennett B. Intracranial-pressure changes following head injury. Lancet. 1970 Aug 29;2(7670):433–436. doi: 10.1016/s0140-6736(70)90054-1. [DOI] [PubMed] [Google Scholar]
  5. LANGFITT T. W., WEINSTEIN J. D., KASSELL N. F., GAGLIARDI L. J. TRANSMISSION OF INCREASED INTRACRANIAL PRESSURE. II. WITHIN THE SUPRATENTORIAL SPACE. J Neurosurg. 1964 Nov;21:998–1005. doi: 10.3171/jns.1964.21.11.0998. [DOI] [PubMed] [Google Scholar]
  6. Lundberg N. Monitoring of intracranial pressure. Proc R Soc Med. 1972 Jan;65(1):19–22. doi: 10.1177/003591577206500108. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Lundberg N., Troupp H., Lorin H. Continuous recording of the ventricular-fluid pressure in patients with severe acute traumatic brain injury. A preliminary report. J Neurosurg. 1965 Jun;22(6):581–590. doi: 10.3171/jns.1965.22.6.0581. [DOI] [PubMed] [Google Scholar]
  8. Nornes H., Magnaes B. Supratentorial epidural pressure recorded during posterior fossa surgery. J Neurosurg. 1971 Nov;35(5):541–549. doi: 10.3171/jns.1971.35.5.0541. [DOI] [PubMed] [Google Scholar]
  9. Nornes H., Serck-Hanssen F. Miniature transducer for intracranial pressure monitoring in man. Acta Neurol Scand. 1970;46(2):203–214. doi: 10.1111/j.1600-0404.1970.tb05616.x. [DOI] [PubMed] [Google Scholar]
  10. Numoto M., Slater J. P., Donaghy R. M. An implantable switch for monitoring intracranial pressure. Lancet. 1966 Mar 5;1(7436):528–528. doi: 10.1016/s0140-6736(66)91531-5. [DOI] [PubMed] [Google Scholar]
  11. Richardson A., Hide T. A., Eversden I. D. Long-term continuous intracranial-pressure monitoring by means of a modified subdural pressure transducer. Lancet. 1970 Oct 3;2(7675):687–690. doi: 10.1016/s0140-6736(70)91960-4. [DOI] [PubMed] [Google Scholar]
  12. Schettini A., McKay L., Majors R., Mahig J., Nevis A. H. Experimental approach for monitoring surface brain pressure. J Neurosurg. 1971 Jan;34(1):38–47. doi: 10.3171/jns.1971.34.1.0038. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Neurology, Neurosurgery, and Psychiatry are provided here courtesy of BMJ Publishing Group

RESOURCES