Abstract
Artefacts which occur during the processing of small biopsy specimens can cause sufficient tissue distortion to impair interpretation and can be a considerable source of nuisance. Triangular artefacts were noted in renal and liver biopsy specimens which were caused by foam sponges in embedding cassettes. Scanning electron microscopic examination of the sponges showed they comprised a mesh of scimitar-shaped rigid spikes which closely match the artefacts seen in the tissues.
Full text
PDF

Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Kepes J. J., Oswald O. Tissue artefacts caused by sponge in embedding cassettes. Am J Surg Pathol. 1991 Aug;15(8):810–812. doi: 10.1097/00000478-199108000-00013. [DOI] [PubMed] [Google Scholar]
- Landas S. K., Bromley C. M. Sponge artifact in biopsy specimens. Arch Pathol Lab Med. 1990 Dec;114(12):1285–1287. [PubMed] [Google Scholar]