Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 1982 Oct;35(10):1138–1141. doi: 10.1136/jcp.35.10.1138

Detection of antibodies to tetanus toxoid: comparison of a direct haemagglutination method with a radioimmunoassay.

A S Wang, G F Burns, I J Kronborg, I R Mackay
PMCID: PMC497898  PMID: 7130423

Abstract

Two methods of detecting antibodies to tetanus toxoid were compared, a radioimmunoassay (RIA) employing radiolabelled staphylococcal protein A and a direct haemagglutination (HA) method employing sheep erythrocytes coupled to tetanus toxoid with chromic chloride. These were shown to have a similarly high specificity with the HA method showing slightly higher sensitivity. Haemagglutination offers several additional advantages in terms of simplicity, low cost and less requirement for specialised equipment. The assays were also used to demonstrate a transient IgM response after repeated booster injections with absorbed toxin given to seropositive individuals, and these antibodies were found to be protective in biological tests.

Full text

PDF
1138

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Barr A., Dow B. C., Watson W. C., Hunter E. Detection and quantitation of tetanus antitoxin in blood donations. J Clin Pathol. 1975 Dec;28(12):969–971. doi: 10.1136/jcp.28.12.969. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Burns G. F., Pike B. L. Spontaneous reverse haemolytic plaque formation. I. Technical aspects of the protein A assay. J Immunol Methods. 1981;41(3):269–277. doi: 10.1016/0022-1759(81)90190-3. [DOI] [PubMed] [Google Scholar]
  3. Hernandez R., Just M., Bürgin-Wolff A. Immunoglobulin classes of human antitoxin after tetanus vaccination studied by immunofluorescence with agarose bound tetanus toxoid. Z Immunitatsforsch Exp Klin Immunol. 1973 Jun;145(4):376–384. [PubMed] [Google Scholar]
  4. Ling N. R., Bishop S., Jefferis Use of antibody-coated red cells for the sensitive detection of antigen and in rosette tests for cells bearing surface immunoglobulins. J Immunol Methods. 1977;15(3):279–289. doi: 10.1016/0022-1759(77)90065-5. [DOI] [PubMed] [Google Scholar]
  5. Repetti C. F., Gill T. J., 3rd Radioimmunoassay of IgM and IgG antitetanus toxoid antibody. J Immunol Methods. 1980;37(2):153–163. doi: 10.1016/0022-1759(80)90200-8. [DOI] [PubMed] [Google Scholar]
  6. Salonen E. M., Vaheri A. Immobilization of viral and mycoplasma antigens and of immunoglobulins on polystyrene surface for immunoassays. J Immunol Methods. 1979;30(3):209–218. doi: 10.1016/0022-1759(79)90095-4. [DOI] [PubMed] [Google Scholar]
  7. Stevens R. H., Saxon A. Differential synthesis of IgM and IgA anti-tetanus toxoid antibody in vitro following in vivo booster immunization of humans. Cell Immunol. 1979 Jun;45(1):142–150. doi: 10.1016/0008-8749(79)90369-1. [DOI] [PubMed] [Google Scholar]
  8. Zurawski V. R., Jr, Haber E., Black P. H. Production of antibody to tetanus toxoid by continuous human lymphoblastoid cell lines. Science. 1978 Mar 31;199(4336):1439–1441. doi: 10.1126/science.204013. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group