Table 5.

Simulated Change in Red Cell Collection, Hb Deferrals, and Donor Iron Depletion Under Modified Policies1

SimID Hgb cutoff Donation interval Red Cell
Components
Donated2
Hb
Deferrals2
% of Red Cell Donation
Visits with3
Female Male Female Male Ferr<12 Ferr<26
Baseline
(cv)
12.5 12.5 8 8 2,112,497
0.04%
160,924
0.02%
13.1%
0.02%
34.0%
0.01%
Δ to Baseline simulation % RC Visits Ferr< 12 or 26
Sim 1
Sim 2
Sim 3
12.5 12.5 12 12 −7.7% −4.9% 11.6% 31.9%
12.5 12.5 16 12 −9.5% −9.1% 11.0% 31.0%
12.5 12.5 16 16 −13.3% −9.3% 10.8% 30.7%
Sim 4
Sim 5
Sim 6
12.0 13.0 8 8 3.5% −27% 13.8% 35.2%
12.5 13.0 8 8 −1.1% 5.4% 13.1% 34.0%
12.5 13.5 8 8 −4.0% 21% 13.1% 34.1%
Sim 7
Sim 8
Sim 9
Sim 10
12.0 13.0 12 12 −4.8% −31% 12.1% 32.8%
12.5 13.5 12 12 −10.0% 13% 11.6% 32.1%
12.0 13.0 16 12 −7.3% −32% 11.3% 31.7%
12.5 13.5 16 12 −11.8% 8.7% 11.0% 31.1%

Shaded cells represent conditions altered from baseline (status quo) scenario

1

Standard error estimates and approximations were calculated for each cell based on 38 simulations for each level of the parameters. All standard error estimates were less than .32%.