. 1998 Apr;51(4):275–279. doi: 10.1136/jcp.51.4.275

The importance of "like to like" ISI calibrations with freeze dried plasmas. European Concerted Action on Anticoagulation.

L Poller 1, A M van den Besselaar 1, J Jespersen 1, A Tripodi 1, D Houghton 1
PMCID: PMC500669  PMID: 9659238

Abstract

AIM: To assess reliability of like to like and cross species calibrations using two types of certified freeze dried plasma calibrants--artificially depleted of vitamin K clotting factors, and from coumarin treated patients. METHODS: Six ECAA national control laboratories provided certified values for the freeze dried plasmas in terms of the human plain international reference preparation (IRP) (BCT/441) with the manual prothrombin time technique. Eight other ECAA national laboratories determined international sensitivity index (ISI) values in full fresh plasma same species and cross species WHO calibrations against a low ISI human IRP (BCT/441) of the ECAA low ISI human thromboplastin and high ISI ECAA rabbit thromboplastin. Parallel calibrations were performed using the certified values. RESULTS: Calibrations on fresh plasmas of the human ECAA reference thromboplastin (stated ISI = 0.95) gave ISI of 0.957 against the human IRP and 1.66 against the rabbit IRP. The ECAA rabbit (stated ISI = 1.67) gave an identical value on the fresh plasma calibration v the human IRP. With freeze dried depleted plasmas certified in terms of the human IRP, the ISI of the ECAA human was 1.01, but the ECAA rabbit (stated ISI = 1.67) gave a low ISI of 1.47. The freeze dried coumarin plasmas gave an ISI of 0.943 for the ECAA human but only 1.493 for the ECAA rabbit. CONCLUSIONS: Fresh plasmas give reliable ISI when calibrating thromboplastins in same species and cross species calibrations. Freeze dried plasmas certified in terms of a single IRP, whether artificially depleted or of coumarin plasma origin, cannot be used for calibration of dissimilar thromboplastins.

Full text

PDF
275

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Clarke K., Taberner D. A., Thomson J. M., Morris J. A., Poller L. Assessment of value of calibrated lyophilised plasmas to determine International Sensitivity Index for coagulometers. J Clin Pathol. 1992 Jan;45(1):58–60. doi: 10.1136/jcp.45.1.58. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Hermans J., van den Besselaar A. M., Loeliger E. A., van der Velde E. A. A collaborative calibration study of reference materials for thromboplastins. Thromb Haemost. 1983 Oct 31;50(3):712–717. [PubMed] [Google Scholar]
  3. Poller L., Barrowcliffe T. W., van den Besselaar A. M., Jespersen J., Tripodi A., Houghton D. European Concerted Action on Anticoagulation (ECAA)-the multicentre calibration of rabbit and human ECAA reference thromboplastins. Steering Committee. Thromb Haemost. 1996 Dec;76(6):977–982. [PubMed] [Google Scholar]
  4. Poller L., Barrowcliffe T. W., van den Besselaar A. M., Jespersen J., Tripodi A., Houghton D. Minimum lyophilized plasma requirement for ISI calibration. European Concerted Action on Anticoagulation. Am J Clin Pathol. 1998 Feb;109(2):196–204. doi: 10.1093/ajcp/109.2.196. [DOI] [PubMed] [Google Scholar]
  5. Poller L., Thomson J. M., Taberner D. A., Clarke D. K. The correction of coagulometer effects on international normalized ratios: a multicentre evaluation. Br J Haematol. 1994 Jan;86(1):112–117. doi: 10.1111/j.1365-2141.1994.tb03260.x. [DOI] [PubMed] [Google Scholar]
  6. Poller L., Triplett D. A., Hirsh J., Carroll J., Clarke K. A comparison of lyophilized artificially depleted plasmas and lyophilized plasmas from patients receiving warfarin in correcting for coagulometer effects on international normalized ratios. Am J Clin Pathol. 1995 Mar;103(3):366–371. doi: 10.1093/ajcp/103.3.366. [DOI] [PubMed] [Google Scholar]
  7. Tripodi A., Chantarangkul V., Braga M., Poller L., ten Cate J. W., van den Besselaar A. M., Mannucci P. M. Results of a multicenter study assessing the status of standardization of a recombinant thromboplastin for the control of oral anticoagulant therapy. Thromb Haemost. 1994 Aug;72(2):261–267. [PubMed] [Google Scholar]
  8. Tripodi A., Poller L., van den Besselaar A. M., Mannucci P. M. A proposed scheme for calibration of international reference preparations of thromboplastin for the prothrombin time. On behalf of the Subcommittee on Control of Anticoagulation. Thromb Haemost. 1995 Nov;74(5):1368–1369. [PubMed] [Google Scholar]
  9. van den Besselaar A. M. Use of lyophilized calibration plasmas and control blood for international normalized ratio calculation in external quality assessment of the prothrombin time. Am J Clin Pathol. 1994 Jul;102(1):123–127. doi: 10.1093/ajcp/102.1.123. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group

RESOURCES