Abstract
The postvoid residual volume (PVR) is a common urodynamic parameter used to quantify the severity of lower urinary tract dysfunction. However, the serial cystometrograms that are typically used to assess bladder function in animal models make measuring PVR very difficult. Current approaches are to either remove PVR after each void to measure it, which is disruptive to the bladder, or to neglect the unknown contribution to PVR from ureter flow, which results in inaccurate estimates. We propose a procedure to estimate PVR during a serial cystometrogram that requires only a single measurement, rather than measuring after each void. Moreover, this measurement can occur at the end of the experiment such that it does not affect the bladder during data collection. We mathematically express PVR for all voids during a serial cystometrogram using a linear recurrence equation and use this equation to build an estimation procedure for PVR. Using in vivo measurements in urethane anesthetized rats and computer simulations we show that the estimation procedure is at least as accurate in determining PVR as the traditional method of measuring PVR after each void. Furthermore, we demonstrate the adverse effects of repeated PVR measurements in a common animal model of cystitis. Using the proposed procedure can increase the efficiency and accuracy of determining PVR for a serial cystometrogram and is less disruptive to the system under study. This, in turn, allows the calculation of other urodynamic parameters that are critical for research studies, including voiding efficiency and bladder capacity.
Keywords: voiding efficiency, urodynamics, underactive bladder, rat, ureter, recurrence equation
the postvoid residual volume (PVR) is one of many common urodynamic measures obtained from in vivo cystometric animal studies used to describe bladder filling phase and voiding dynamics. PVR is also used to assess urinary retention and other urinary tract dysfunctions in animal models. In a clinical setting, PVR, along with other urodynamic measures, is used to help assess and manage patients with a variety of lower urinary tract symptoms (1–3, 7, 13, 14). When expressed as a fraction of bladder capacity, PVR quantifies how efficiently the lower urinary tract expels the bladder contents during a void. Voiding efficiency (VE) is commonly used to determine the effectiveness of bladder emptying (8, 10, 15, 17) and is written as
| (1) |
where Vv is the volume voided and Vr is the PVR. VE is the fraction of total bladder volume expelled during the void and is bounded between zero and one. Therefore, VE is intrinsically normalized to each animal's bladder capacity, which makes it an ideal metric to evaluate bladder function in a heterogeneous population or across differing experimental conditions. Furthermore, PVR allows one to calculate the starting and ending volumes of each voiding event. This is critical information needed to determine the bladder volume as a function of the measured bladder pressure throughout the filling process, which can then be used to estimate bladder tension and compare cystometrograms through time (4, 18).
Unfortunately, PVR is difficult to measure directly in animal experiments. It is common in animal studies to perform a serial cystometrogram by inserting a catheter through the dome of the bladder and continuously infusing fluid to observe lower urinary tract function over repeated voiding events (11). This approach is useful for quantitative descriptions of bladder function and increasing statistical power, but it is difficult to obtain the PVR of each void in the series. During a serial cystometrogram, volume enters the bladder through the catheter, but concurrently volume enters via the ureters at an unknown rate. Therefore, measuring the voided volume alone is insufficient to determine the PVR. To handle this problem the experimenter is forced to choose among three unsatisfactory options. The first is to remove the PVR after each void to measure it, which is undesirable because removing the PVR does not correspond to the natural physiological conditions the experiment is designed to study. The second is to neglect the unknown renal contribution to bladder volume, which results in a systematic underestimation of PVR. The third is simply to forego any measurement of PVR and all the parameters whose calculation requires PVR.
To address the difficulties in measuring PVR during serial cystometrograms, we propose a procedure that estimates all residual volumes in the series using only a single measurement of PVR. Moreover, this single measurement is obtained at the end of the experiment, such that it does not interfere with the system during data collection. We derive the procedure from a mass balance approach and establish its accuracy by comparing traditional measurements with those obtained using the proposed estimation procedure in both in vivo rat experiments and in computer simulations.
METHODS
All animal care and procedures were reviewed and approved by the Institutional Animal Care and Use Committee at Duke University. Female Sprague-Dawley rats (0.267 ± 0.015 kg, mean ± SD, n = 7) were initially anesthetized with 3% isoflurane, followed by two subcutaneous injections of urethane totaling 1.2 g/kg (dissolved as 0.2 mg/ml in 0.9% saline solution). A catheter (PE50) with a heat-flared tip was inserted into the bladder dome and secured with suture. The animal lay supine on a heated water blanket to maintain body temperature. Heart rate and blood oxygenation were monitored with a pulse oximeter on the hindpaw. Following the experiment the animal was killed with an intraperitoneal injection of 500 mg of Euthasol.
Room temperature 0.9% saline solution was infused via syringe pump into the bladder until a void occurred. Once the void was completed the pump was stopped and PVR was measured by withdrawing the bladder volume manually through the catheter using a 1-ml Luer Lock syringe. Following this measurement, the residual volume was slowly reinserted into the bladder using the same syringe. Voided volume was then measured and the pump was restarted. In three animals, following serial cystometrograms and data collection, the ureters were clamped. The bladder was emptied and a known amount of fluid was inserted into the bladder. A second experimenter, blinded to the volume, attempted to withdraw and measure the bladder contents. A total of 65 such measurements were performed, and the standard deviation of the difference between the inserted and measured volumes was used to determine the expected error in PVR (see left edge of the white rectangle in Fig. 2A) and ξ(Vr) (see Table 2). In two animals the serial cystometrogram protocol could not be completed successfully because the bladder contracted, generating voiding, on reinsertion of the residual, and all data from these animals were excluded from analysis.
Fig. 2.
Simulations comparing accuracy of VE calculations using the estimation procedure and standard measurements. A: heatmap of the loss in accuracy, L (Eq. 3), when estimating rather than measuring VE. Negative L (orange) indicates parameter combinations where the estimation procedure outperformed standard measurements. The white rectangle encloses the region where the true vales of σ(V̇u) and ξ(Vr) for the experiments conducted in Fig. 1 are likely to be located. Simulation parameters are listed in Table 2. B–D: the effects of varying a parameter from the nominal values used to generate the plot in A. Each line represents the L = 0 equivalence frontier for the listed parameter change, and the black line is the equivalence frontier from A. Parameters examined were the number of voids in the serial cystometrogram (N), the residual volume (Vr), and the amount of noise corrupting the measurements of the voided volume [ξ(Vr)]. The gray region corresponds to the white rectangle in A. Values of L for A–D were determined by averaging across 100 repetitions of the simulated serial cystometrogram at each parameter combination.
Table 2.
Nominal cystometry simulation parameters
| Parameter Name | Symbol | Value |
|---|---|---|
| Ureter flow rate | V̇u | 0.20 ml/h |
| Ureter flow rate SD | σ(V̇u) | Variable ml/h |
| Residual volume | Vr | 0.10 ml |
| Residual volume | σ(Vr) | 0.04 ml |
| Residual measurement noise | ξ(Vr) | Variable ml |
| Intervoid interval | ti | 8 min |
| Intervoid interval SD | σ(ti) | 1 min |
| Infusion rate | V̇i | 4 ml/h |
| Void measurement noise | ξ(Vv) | 0.005 ml |
| Number of consecutive trials | N | 10 |
The parameters V̇u, Vr, and σ(Vr) were the averages of measured values from the trials shown in Fig. 1. The voided volume, Vv, is omitted from table 1 because it is determined by specifying the other parameters in the simulation. We assumed that ti was known exactly. tu Was equal to ti for all simulations.
A second series of experiments were conducted to test the effects of invasive PVR measurements on urodynamic outcomes. Fifteen animals were surgically prepared as described above (0.275 ± 0.014 kg). In these animals we infused acetic acid dissolved to 0.25% concentration in 0.9% saline solution at room temperature as an acute model of cystitis. In addition, we recorded external urethral sphincter electromyographic activity using fine platinum iridium wire electrodes placed near the urethra, and we applied Vaseline to the skin near the meatus to prevent cutaneous irritation by the acetic acid. The bladder was filled continuously at 2.5 ml/h for four to six voiding cycles following surgery to allow the urinary tract to acclimate. In all animals we performed four separate serial cystometrograms of seven voids each at a fill rate of 2.5 ml/h, separated by 20-min quiet periods without filling (see Fig. 3A). Within each of the four serial cystometrograms, we obtained the PVR for all voids in one of two ways: 1 stopping the infusion pump after each void and withdrawing (and not replacing) the bladder contents through the suprapubic catheter, or 2 only measuring the last PVR directly and using our estimation procedure to determine the other PVRs in the serial cystometrogram. The estimation and measurement procedures were alternated for each serial cystometrogram in the crossover design, and the measurement type of the first block was randomized (see Fig. 3A). One of the 15 animals exhibited extreme sensitivity to acetic acid and voided immediately when the infusion pump was started. Data could not be collected for this animal and it was excluded from all analysis.
Fig. 3.

Comparison of traditional measurement method to the proposed estimation procedure to calculate PVR during a serial cystometrogram with 0.25% acetic acid. A: following catheter implantation, 4–6 fill and void cycles were performed in each animal to allow recovery of normal voiding. Four blocks of serial cystometrograms were performed containing seven voids each. Each block was alternated between invasive measurement of PVR, by withdrawing volume through the catheter, and the noninvasive estimation procedure. A 20-min period where no filling occurred elapsed between each serial cystometrogram. The 14 animals were equally distributed between sequences 1 and 2. B: the coefficient of variation of bladder capacity is significantly higher when removing PVR for direct measurement than with the noninvasive estimation procedure. C: 95% confidence intervals over the difference in bladder capacity when using the direct measurement or estimation procedure for measuring PVR. The data show many more significant changes in bladder capacity than would be expected by chance.
Software to perform Vr and ureter flow rate estimation is provided in the Supplemental Material (MATLAB 2015a and Microsoft Excel 2013; Supplemental Material for this article is available online at the Journal website). Statistical analysis, including repeated-measures ANOVA, was done using the statistics toolbox (MATLAB 2015a). Boxplot edges mark the 25th and 75th percentiles of the data, the centerline shows the median value, and whiskers extend to cover the central 99.3% of normally distributed data. Data points are superimposed over the boxplot with horizontal jitter for clarity.
RESULTS
We describe a procedure to estimate postvoid residual (PVR) for a serial cystometrogram without the need to measure multiple residual volumes. We first present an overview of the procedure, describe how to use the method, and highlight its limitations. A full mathematical derivation is provided in appendix 1. We then evaluate the effectiveness of the procedure using an in vivo experiment and quantify its accuracy using numerical simulations. In an additional set of in vivo studies, we compare the biological impact of our proposed procedure to that of traditional measurements.
Overview of the estimation procedure.
During serial cystometry, volume is infused into the bladder from a catheter and, simultaneously, volume enters the bladder through the ureters. During a void, the bladder contracts to expel a portion of the accumulated volume through the urethra and retains the rest as a residual volume. This description accounts for the entirety of the volume passing through the bladder during a serial cystometrogram, and we express these relations in Eq. 2.
| (2) |
The equation states that, for any void in the serial cystometrogram, the postvoid residual volume (Vr) plus the voided volume (Vv) must equal the volume entering the bladder through the ureters (Vu) plus the volume infused through the catheter (Vi) plus the residual volume from the previous void in the series [Vr(previous)]. Generally, the experimenter will know Vi because it is under their control and will know Vv because it is easy to measure accurately and noninvasively.
We are interested in the value of Vr after each void; however, Eq. 2 cannot be solved for Vr (in terms of known quantities) because Vu is unknown. There are two common approaches to this problem. The first method is to neglect Vu (assume it is zero; Refs. 5, 9, 19), which results in an underestimate of Vr. The second method is to remove Vr after each void to measure it directly (6, 12, 16). However, this can irritate the bladder and is a departure from the physiological conditions that the experiment aims to study (i.e., PVR normally remains in the bladder after voiding). Our proposed estimation procedure allows us to compute Vr without removing bladder volume during a serial cystometrogram, which we explain in the remainder of this section.
Equation 2 allows us to express Vr for each void as the net accrual of bladder volume from the previous void. Meaning, Vr for the last void is the difference between the incoming and outgoing volume of the last void plus the second to last residual. Likewise, the second to last residual is the net volume of the second to last void plus the third to last residual. This recursion continues until we reach the first void in the series. Therefore, the only unknown quantities in this recursive expression for the last residual volume are the last residual itself [Vr(last)], the initial bladder volume that cannot be expressed in terms of a previous void [Vr(1st)], and the volume contribution from the ureters (Vu).
However, when the catheter is initially inserted into the bladder all of the fluid can be withdrawn through the catheter or pushed out by gently expressing the bladder. This will set the initial bladder volume to zero, and eliminate Vr(1st) as an unknown. Additionally, once the serial cystometrogram is over and the experiment completed, the final residual volume can be measured without interfering with subsequent trials. Therefore, the only remaining unknown is the volume contribution from the ureters. If we assume that volume enters the bladder via the ureters at an unknown rate that is the same throughout the serial cystometrogram, we can use this recursive form of Eq. 2 to solve for the constant unknown ureter flow rate. Finally, using this estimate of the ureter contribution [and the fact that we know Vr(last) and Vr(1st) = 0], we can use Eq. 2 to compute all of the residual volumes throughout the serial cystometrogram.
Thus this estimation procedure allows us to compute the residual volumes of each void in a serial cystometrogram without measuring them explicitly and without neglecting the volume contribution from the ureters. Below, we also discuss the accuracy of assuming a constant ureter flow rate, quantify the loss of accuracy if this assumption is not true, and provide approaches without this assumption. A practical user's guide to implementing this procedure is provided in appendix 4.
Comparison of estimation with experimental measurements.
To assess the similarity of PVR values obtained from the proposed estimation procedure and traditional PVR measurements we performed six serial cystometrogram experiments in five rats. The bladder was filled through a suprapubic catheter until a void occurred. Voided volume and PVR were measured and PVR was subsequently reinserted into the bladder, allowing us to measure PVR after each void and also to emulate an experiment where PVR was not removed from the bladder for measurement. As outlined in the description of the estimation procedure, we used the final measured PVR in the serial cystometrogram to estimate all other PVR in the series (Eqs. 7 and 8, appendix 1). We then used either the estimated or measured PVR to compute voiding efficiency (VE, Eq. 1), which is a within animal normalized metric that allowed us to compare results across animals with different bladder capacities. There was close agreement between the estimated and measured VEs (Fig. 1). The magnitude of the difference between estimated and measured VEs for the serial cystometrograms in Fig. 1 was 0.037 ± 0.014. Parameters for each serial cystometrogram are listed in Table 1.
Fig. 1.
The proposed estimation procedure produced voiding efficiency (VE) estimates that were similar to the VEs measured during serial cystometrograms in anesthetized rats. A–F: the estimated (dashed blue) and measured (solid orange) VEs are shown for each voiding event in the serial cystometrogram. The estimation procedure was performed using the measurement of the last Vr in the series. Parameters for each serial cystometrogram are given in Table 1.
Table 1.
Cystometrogram parameters
| Fig. 1 | Rat ID | Infusion Time, min | Bladder Capacity, ml | Infusion Rate, ml/h |
|---|---|---|---|---|
| A | 1 | 7.60 ± 1.69 | 0.56 ± 0.09 | 4 |
| B | 2 | 7.32 ± 3.33 | 0.28 ± 0.08 | 1.85 |
| C | 3 | 5.88 ± 1.90 | 0.36 ± 0.10 | 3 |
| D | 6 | 4.18 ± 2.54 | 0.26 ± 0.06 | 2 |
| E | 7 | 4.47 ± 1.62 | 0.35 ± 0.07 | 2 |
| F | 7 | 9.58 ± 13.6 | 0.34 ± 0.10 | 2 ± 1 |
Data are means ± SE and correspond to Fig. 1, A–F.
Determining estimation accuracy using computer simulations.
It is not possible to determine the accuracy of the traditional method of measuring VE or our estimation procedure from the data presented in Fig. 1; it is only possible to show the difference between the values because the true VE for each void is obscured by measurement noise in PVR (Vr) and the voided volume (Vv). Therefore, we performed a computer simulation of serial cystometrograms to quantify the accuracy of the estimation procedure and traditional measurements in a case where the true VE was known. We performed the simulation as a set of successive volume balances defined by Eq. 2 (and therefore, we did not explicitly model bladder pressure). The value of each parameter was drawn from a normal distribution (if variability was added) with mean and standard deviation listed in Table 2 (simulations deviate from these nominal values as indicated in Fig. 2).
To evaluate the difference in accuracy between the proposed procedure for estimating VE and measuring VE in the traditional way, Gaussian noise was applied to the true values of Vv and Vr (Table 2, ξ). We used these noise-corrupted values to calculate VE using both the traditional measurement method and the new estimation procedure to emulate experimental conditions. The accuracy loss, L, of using the estimate rather than measuring VE for a full serial cystometrogram of N voids was expressed with the following metric
| (3) |
where VE(k) is the true voiding efficiency for the kth void, VEe and VEm are the estimated and measured voiding efficiency, respectively, and |.| is the absolute value.
The accuracy loss, L, as a function of the variability in ureter flow rate, σ(V̇u), and noise in the residual volume measurement, ξ(Vr), is plotted in Fig. 2A. The vertical axis can be interpreted as the degree to which the assumption of constant ureter flow rate is violated, because σ(V̇u) is the variability of V̇u across voiding events, and as expected, L increased with σ(V̇u).
The left edge of the overlaid white rectangle corresponds to the expected value of ξ(Vr) based on experimental measurements (−0.01 ± 0.05 ml, see methods). This value is likely to be an underestimate of ξ(Vr) because measurements were performed by an expert in vivo experimentalist (12 yr of experience) with the rat supine and the bladder exposed; typical measurement conditions would be more difficult. The top edge of the white rectangle is the expected value of σ(V̇u) calculated from the experimental measurements (Fig. 1, A–F). Meaning, the ureter flow rate was calculated algebraically from the measurements of each Vr, Vv, and infused volume using Eq. 2, and the standard deviation was computed. The resulting value is likely an overestimate of σ(V̇u) because V̇u was computed for each void using noisy measurements, which artificially inflate σ(V̇u). Therefore, the rectangle enclosed by the two white lines is the region where we expect the true values σ(V̇u) and ξ(Vr) for our in vivo experiments shown in Fig. 1.
The black region of Fig. 2A, where L is approximately zero, represents a frontier of equivalence between the estimation and measurement methods for calculating VE. To the right of the black band (the equivalence frontier) L is negative, indicating that, remarkably, the estimation method is more accurate than the measurements. This occurs because when computing all VE(k) in a serial cystometrogram using measurements, every calculation incorporates a different Vr(k), which all have associated uncertainty. When estimating VE(k) with Eqs. 7 and8, only one residual measurement is used, Vr(k=N), and the calculation is performed using the far less uncertain Vv(k), and the very precise V̇i(k), ti(k), and tu(k).
The effects on the equivalence frontier of varying key parameters are shown in Fig. 2, B–D, where each line represents the equivalence frontier for the noted parameter change. The estimation method is more accurate for smaller numbers of serial voids, because VE is estimated recurrently and error is propagated through the estimates of all Vr(k) (Fig. 2B). For small residual volumes, the estimation method becomes less accurate relative to standard measurements (Fig. 2C). This occurs because when adding measurement variability to small residuals in the simulation, the resulting Vr may be negative, and when this occurred we set Vr to zero. This effectively reduced σ(Vr) for small Vr, which is more beneficial for the direct measurement method than the estimation method. This effect was also present in experimental measurements where a negative Vr is never recorded. In practice, this non-negativity constraint causes measurements of low Vr to have lower σ(Vu), because it limits the degree of underestimation of Vr. Finally, the effects of changing ξ(Vv) are shown in Fig. 2D. There is far less uncertainty in measuring Vv than Vr because all expelled volume can be readily collected. Therefore, we set the nominal value of ξ(Vv) to 0.005 ml, which is the margin of error for our measurement device (a 1-ml syringe with 0.01 ml demarcations). The simulation indicates that the equivalence frontier is very robust to increases in ξ(Vv) because both the estimation and the measurement methods incorporate all Vv(k) to compute VE.
The effect of residual volume measurement in an acetic acid model of cystitis.
In an additional set of experiments we performed four blocks of serial cystometrograms with 0.25% acetic acid and alternated between traditional invasive measurements of PVR and our estimation procedure in each block (Fig. 3A). The animals were pseudorandomly assigned to a measurement sequence such that there were an equal number in each group. We focused our analysis on bladder capacity because it is the most critical and commonly investigated urodynamic outcome in cystitis and computing bladder capacity in a serial cystometrogram requires knowledge of PVR.
The direct measurement method increased the void-by-void variation in bladder capacity. A paired t-test revealed a significant increase in the variability of bladder capacity within each animal when removing PVR for measurement (Fig. 3B, P = 0.026) compared with the estimation procedure. Variation in bladder capacity was quantified using the coefficient of variation (CV) because overall bladder capacity varied substantially between animals (0.25 ± 0.17 ml) and the CV normalizes variation to the mean. This increase in variability is likely to be an artifact of the direct measurement method, and may be caused by irritation associated with repeatedly removing PVR for measurement.
A repeated-measures ANOVA with sequence as a between subject factor and PVR measurement type as a within subjects factor failed to detect a significant effect of sequence on bladder capacity [F(1,12) = 2.54, P = 0.14]. This indicates that the order in which the measurement types were implemented did not affect bladder capacity. No significant effect of measurement type on bladder capacity was detected [F(1,12) = 1.38, P = 0.26] and no interaction was detected between sequence and measurement type (P = 0.57).
Although no difference in bladder capacity was found between the measurement types when grouping all animals, there were many individual experiments where there were large significant differences in bladder capacity. In 12 of 14 animals bladder capacity was lower when using the direct measurement method, with 7 of those animals having differences significant at the α = 0.05 level. Figuare 3C shows 95% confidence intervals of the difference in bladder capacity between the measurement types for each animal. Nine of 14 animals showed a significant difference in bladder capacity (in either direction) between the two measurement types, whereas if there were no effect of measurement type on bladder capacity we would expect only 1 in 20 animals to show significance at this level. The ANOVA failed to detect an overall difference between measurement types because one animal displayed a very large effect in the opposite direction of the trend (5th from the left, Fig. 3C). For example, if that animal were removed as an outlier, the ANOVA detects a significant effect of measurement type (P = 0.02). Due to interanimal variation, a much larger study is required to determine if the two animals that showed lower bladder capacity during the estimation procedure are the result of natural variation, are outliers, or represent a subpopulation of animals that consistently respond in this way.
PVR errors caused by neglecting ureter inflow.
An alternate approach to estimate PVR and bladder capacity is to neglect the contribution of filling from the ureters. If the only source of bladder filling were the experimenter-infused volume, then PVR could be calculated algebraically using measurements of the voided volume (Eq. 2). However, because the volume entering from the ureters is nonzero, neglecting it will result in errors in PVR and bladder capacity estimates.
We empirically determined the magnitude of error caused by neglecting ureter flow by comparing the bladder capacity in the acetic acid trials obtained using our estimation procedure with what would have been obtained had we neglected the ureter flow (setting V̇u = 0). The error, as a percent of bladder capacity, is plotted in Fig. 4A, where each point is the error averaged over all voids in one acetic acid serial cystometrogram. We restricted this analysis to blocks where the estimation method was used because when neglecting ureter flow to compute PVR no volume would be removed from the bladder. A student's t-test rejected the hypothesis that the error caused by neglecting ureter flow was zero (P < 10−5).
Fig. 4.

Errors in estimation of bladder capacity caused by neglecting ureter flow. A: the error as a percentage of bladder capacity caused by neglecting ureter flow for the estimation procedure blocks in the acetic acid experiments. B: bladder volume as a function of time as calculated using the estimation procedure (dashed) and by algebraic computation neglecting ureter flow (solid). These examples show the accumulation of underestimation error through time. C: theoretical heatmap (Eq. 4) of the error (as a percentage of bladder capacity) incurred when computing PVR by neglecting ureter flow, as a function of time and ureter flow rate. Median experimental values from the acetic acid serial cystometrograms are overlaid as the black circles, and the white curve is the 10% error isocline.
In Fig. 4B we show the amount of volume in the bladder through time, as obtained using our estimation procedure (blue dashed) and from neglecting ureter flow (green solid) for three examples. These traces show that neglecting ureter flow results in an underestimation of PVR that compounds through time as the total neglected volume continues to grow. Moreover, as error accumulates from neglecting ureter flow, estimates of bladder volume become negative because there is insufficient catheter infusion to account for all the measured voided volume.
More generally, we can compute the error in estimating bladder capacity caused by neglecting ureter flow for any given void (for a constant ureter flow rate) as the difference between total volume passing through the bladder and the infused volume,
| (4) |
where V̇i is the infusion rate, V̇u is the ureter flow rate, and t is the elapsed time of the entire serial cystometrogram (not the time since the previous void). Equation 4 states that the bladder capacity estimation error increases the longer the serial cystometrogram lasts and the larger the ureter flow rate. The error as a percentage of bladder capacity is shown as a function of time and ureter flow rate in Fig. 4C using Eq. 4. The black circles denote the median ureter flow rates and times for the acetic acid serial cystometrograms, indicating 5.9% error at the time of the first void and a 41% error at the seventh. This plot illustrates the high levels of error caused by neglecting the volume entering via the ureters. To maintain an estimation error of <10% of the bladder capacity when neglecting ureter flow, the serial cystometrogram time and ureter flow rate combination must lie to the left of the white curve.
DISCUSSION
We developed and validated a procedure to estimate postvoid residual volumes (and thereby also voiding efficiency and bladder capacity) for a serial cystometrogram that requires only a single measurement of residual volume at the end of the series. Our method shows excellent agreement with the experiment (Fig. 1), and simulations demonstrate that, for common experimental parameters, our estimation will be at least as accurate as traditional measurements that require removing fluid from the bladder after each void to determine the postvoid residual (Fig. 2). appendix 4 includes a practical user's guide on how to implement the estimation procedure, and the Supplemental Material contains a template to perform the basic calculations in Excel as well as MATLAB code to run the more sophisticated estimations described in appendixes 1–3.
The value of our estimation procedure is that it outperforms the alternative methods for obtaining PVR. The first alternative is to neglect ureter flow to compute PVR. However, we demonstrated that this results in high levels of error, especially for longer cystometrograms (Fig. 4). The second alternative is to remove the PVR after each void for measurement. In addition to forcing each void cycle to start from zero volume and collapsing the bladder when withdrawing the PVR (neither of which are physiological), we showed that this method causes increased variability of bladder capacity (in an in vivo cystitis model, Fig. 3B) compared with our noninvasive procedure. Furthermore, our estimation procedure is more accurate than either alternative method under typical experimental conditions (Fig. 2A and Fig. 4C).
Our estimation procedure is a versatile method that can accommodate all ranges of VE, PVR, voided volume, ureter flow rates, infused volumes, serial cystometrogram lengths, and multiple or repeated measurements. For example, Fig. 1F shows a serial cystometrogram in which the bladder infusion rate was a random variable that changed with each fill in the series. The flexibility of this procedure makes it suitable for many types of experiments.
Our estimation procedure also provides a way to measure PVR (and by extension VE and bladder capacity) in chronic animal experiments, which is currently not possible. When an animal is first instrumented for a chronic study, the bladder can be catheterized via the urethra and drained. Thereafter, the time and volume of each void can be recorded using a metabolic cage. Periodically, the animal could be externally catheterized, and the residual volume removed and measured. This would constitute a set of serial cystometrograms, and the data required to estimate PVR for all intervening voids would be available. Similarly, our procedure is also effective for acute unanesthetized animal experiments because it requires only volume and time measurements to produce the estimates of PVR. Conscious animals tend to have smaller PVR; however, our simulations show that for the range of physiological parameters in healthy anesthetized rats, a PVR reduction of 50% results in an accuracy loss of at most ∼2% (less with lower measurement noise, lower flow rate variability, or larger PVR) relative to measuring PVR directly (Fig. 2C). Therefore, this estimation procedure is also suitable for unanesthetized animal studies and other conditions with smaller PVR.
The primary limitation of the method is the assumption that the ureter flow is constant; however, our proposed method performs well in experiments (Fig. 1) and simulations (Fig. 2) with typical levels of ureter flow variability. If there is reason to believe that the ureter flow will vary substantially throughout the course of the experiment, the serial cystometrogram can be broken up into shorter segments where the within-segment variability in ureter flow rate is low. Alternatively, using an extension of the estimation procedure, additional measurements of Vr can be incorporated into the V̇u estimate to increase the accuracy of Vr estimates (Eq. 10, appendix 2). The increase in accuracy as more measurements are incorporated plateaus quickly (Fig. 5), and one additional measurement is likely to be sufficient to improve accuracy to acceptable levels in these cases. Finally, it is possible to solve Eq. 7 for V̇u(k) without assuming a constant flow (see appendix 3); however, this introduces substantial complexities. Because the estimation method functions well with the constant flow assumption across a very wide range of experimental parameters, it may not be necessary to introduce this more sophisticated procedure.
Fig. 5.

The difference in estimated and measured VE for each voiding event was recalculated for each combination of k measurements of Vr used in the estimation procedure (horizontal axis) and averaged to produce the average (thick trace) and standard deviation (gray patch) of the difference. Therefore, the number of differences averaged for each point is n!/[k!(n − k)!], where n is the total number of voiding events in the serial cystometrogram. The red “x” denotes the value when using the last measured residual in the series to estimate VE, as shown in Fig. 1, A–F. A–F corresponds to Fig. 1, A–F.
GRANTS
This work was funded by National Institutes of Health Grants F32-DK-098904 and R01-NS-050514.
DISCLOSURES
No conflicts of interest, financial or otherwise, are declared by the author(s).
AUTHOR CONTRIBUTIONS
Z.C.D. and W.M.G. conception and design of research; Z.C.D. performed experiments; Z.C.D. analyzed data; Z.C.D. interpreted results of experiments; Z.C.D. prepared figures; Z.C.D. drafted manuscript; Z.C.D. and W.M.G. edited and revised manuscript; Z.C.D. and W.M.G. approved final version of manuscript.
Supplementary Material
ACKNOWLEDGMENTS
We thank veteran experimentalist Christopher Langdale for assistance with the residual volume measurements and Dr. Eric Kirshenbaum for clinical perspectives.
Appendix 1
Complete derivation of the PVR estimation method.
The bladder is an input/output system where the law of conservation of mass applies (equivalent to conservation of volume under the physiological range of pressures and temperatures). The volume balance of the bladder for the kth void in a serial cystometrogram (where the residual volume after each void is not removed) can be stated as a first order linear recurrence equation
| (5) |
where Vr is the residual volume, Vv is the voided volume, V̇i is the rate (denoted with the overdot) of volume infusion through the bladder catheter, ti is the duration of the infusion, V̇u is the rate of the ureters, and tu is the duration of ureter flow. Superscripts denote the index of the void and are in parentheses to emphasize that they are not exponents. It is important to note that tu(k) and ti(k) need not be equal. The term tu(k) represents the total time between voided volume measurements because the ureters contribute volume throughout the fill and void. The ti(k) is the total amount of time the infusion pump is on and thereby accounts for periods when pump may be off during a void or measurement of a residual.
By recursively substituting the expression for Vr(k−1) into the volume balance for Vr(k) (Eq. 5) we obtain the nonrecursive expression for the residual volume of any void, n, in a series of voids
| (6) |
We wish to use this expression to compute any arbitrary residual volume. Equation 6 includes tu(k) and Vv(k) that are easily measured, and the terms V̇i(k) and ti(k) that are typically known, independent experimental variables. Furthermore, Vr(0) can be set to zero (or any other known value) at the start of the serial cystometrogram.
V̇u(k) and Vr(n) are the last remaining unknowns in Eq. 6. The V ˙u(k) terms are challenging to account for because they are not in the experimenter's control and cannot be measured in a noninvasive way during each cystometrogram. To estimate the V̇u(k) terms we begin by assuming that ureter flow rate is a constant unknown quantity [i.e., V̇u(k) = V̇u] throughout each serial cystometrogram, the accuracy of which has been investigated above (Fig. 2). We then measure the residual volume once following the last void, N, in the serial cystometrogram (the residual can actually be measured after any void, but we recommend the final void so that the act of measuring has the least impact on the results of future cystometrograms). Because Vr(n) in Eq. 6 does not depend on any other Vr in the serial cystometrogram [except the known Vr(0)], we can solve for V̇u when n = N by substituting in the measured value of Vr(n=N). Using the assumption that V̇u is constant, the solution is written as
| (7) |
| (8) |
Finally, we achieve the goal of computing all PVRs in the series: the solution for V̇u from Eq. 8 is substituted back into Eq. 6 (eliminating the final unknown), thus allowing the calculation of any Vr(n) in the serial cystometrogram.
A useful additional step in estimating VE is to include the constraint that all estimated Vr(n) must be nonnegative. Negative residuals can be caused by underestimating the ureter inflow and occurred rarely in some permutations of our experimental data when voiding efficiencies were very high (Fig. 1). In these cases, we use the smallest V̇u such that Vr(n) ≥ 0 for all k in the seires. Although this procedure requires only a single measurement of Vr to estimate PVR for all trials, combining multiple measurements of Vr can slightly improve the accuracy of the V̇u estimate. An extension of our estimation procedure that can optimally incorporate multiple measurements of Vr is presented in appendix 2.
Appendix 2
Estimation of PVR with multiple measurements of residual volume.
Our estimation procedure can determine Vr of all voids in a serial cystometrogram using a single measurement of Vr. However, if Vr is measured (and reinserted into the bladder) after multiple voids in the series, these measurements can be combined to increase the estimation accuracy of the ureter flow rate, V̇u, thereby increasing the accuracy of each estimated Vr and VE.
The extended estimation procedure uses the method of weighted least squares (WLS), and is outlined below. If m residual measurements are obtained from voids a ∈ {a1, a2, …, am} we can construct the matrix form of Eq. 7 containing all residual measurements
| (9) |
where the arrows represent vector quantities. The WLS solution for V̇u
| (10) |
where is the connonical diagonal weight matrix with elements equal to the inverse variance of the measurement noise of each Vr(k), and the T superscript denotes the transpose operation. If each Vr(k) has a different uncertainty (e.g., the measurements taken in the middle of the experiment are noisier than the final measurement when the bladder can be exposed), and variance (or relative variance) of the noise is known, then Eq. 10 is the optimal solution for V̇u. WLS can also be used in the case where the noise variances are not known, in which case the weight matrix is set to the identity matrix. This solution supports any number of measurements. The software in the Supplemental Material is capable of handling multiple residual measurements for serial cystometrograms by using Eq. 10.
In our in vivo experiments, we found that incorporating multiple measurements has a relatively small effect on our estimates of VE (Fig. 5). To quantify this effect we plotted the average magnitude of the difference between the estimated and measured VE for the experiment data shown in Fig. 1, as a function of the number of measurements used to estimate VE (thick black lines in Fig. 5). Furthermore, we obtained a distribution of averages by repeating the estimation process using all combinations of any given number of Vr measurements for each serial cystometrogram (gray patches in Fig. 5). The data indicate only small improvements when incorporating additional measurements, which levels off quickly after two measurements. In all cases, the discrepancy between measurement and estimate decreased monotonically as more measurements were incorporated into the estimate.
All estimations shown in Fig. 1 were obtained using only the measurement of the final residual in the series; the average magnitude of the difference between the estimated and measured VE in Fig. 1 are shown as the “x”s in Fig. 5. As expected by random chance, some estimates using the final Vr measurement (Fig. 5, A–F) show better than average (F), worse than average (B), or are at the average (C) agreement with the measurements.
Appendix 3
Relaxing the constant ureter flow constraint on PVR estimation.
A potential drawback of Eq. 8, the calculation of V̇u(k), is the assumption of a constant ureter flow rate for each cystometrogram in the series, V̇u(k) = V̇u. As a matter of practice, however, we demonstrated both experimentally (Fig. 1) and theoretically (Fig. 2) that the estimation procedure is at least as accurate as measuring VE directly for typical ureter flow rate variability. Nevertheless, it is possible to solve for V̇u(k) without assuming it is constant. The main challenge with this case is that when solving for the N different V̇u(k), there are fewer measurements than ureter flow rates, which admits an infinite number of possible solutions. One solution among these must be chosen, and there are no guarantees that a given solution will be more accurate than the constant solution in Eq. 8.
For variable V̇u(k) the problem can be reformulated as follows. For any arbitrary number of measurements of Vr (repeated measures on the same cystometrogram or measurements on different cystometrograms)
| (11) |
where the vector contains the m residual measurements, the superscript is the index of the voiding event in the series (following the convention in the main text), and N is the total number of cystometrograms in the series. Equation 7 can then be conveniently expressed in matrix form as
| (12) |
Each column in the (N by m)tu matrix is constructed by concatenating all values of tu(k) up to cystometrogram ai, followed by (N − ai) zeroes. In this form, Eq. 12 can be solved readily for all V̇u(k) (where each element is potentially different, and therefore, a constant ureter flow rate is not enforced) with the same procedure used to solve Eq. 9. The software supplied in the Supplemental Material is also able to compute this solution.
If m < N, that is, if there are fewer measurements than there are cystometrograms (which is almost certain to be the case), Eq. 12 is underdetermined. This results in the so-called minimum norm solution for , and there will be no weight matrix as in Eq. 10. The minimum norm solution has very little to do with the physiological realities of the ureter flow rate, and we should not expect this solution to outperform the solution constrained to constant ureter flow.
Future work may expand Eq. 12 to include a regularization term that constrains the solution. Potential regularization candidates include the magnitude of the standard deviation of . This constraint would favor solutions with less overall ureter flow variations, which is reasonable because we observe relatively low variations throughout serial cystometrograms. Another possibility is to use the vector magnitude of the successive differences in . This would not penalize overall variability but rather would penalize large changes in flow rates for adjacent cystometrograms. This may be a more realistic constraint if, for instance, ureter flow rate is slowly declining throughout a long serial cystometrogram. Such regularized solutions will perform better the more that is known (and can be incorporated into the regularization) about the structure of ureter flow variability. Regardless of the regularization, we expect only modest gains over the procedure presented in the main text because it was demonstrated to be quite accurate for typical experimental conditions.
Appendix 4
Practical usage guide to implement the estimation procedure.
To implement the PVR estimation procedure, we created a data table for each serial cystometrogram (SCMG). The table has four columns: 1) the infused volumetric flow rate into the bladder, 2) measured voided volume, 3) the amount of time the infusion pump was running, and 4) the time between voids (i.e., the duration ureters added volume to the bladder since the last measurement). Place data from each voiding cycle in the SCMG in successive rows in the table. Lastly, record the measured residual volume of the final void cycle in the SCMG.
We illustrate how to build the data table and compute the intervoid interval (ureter time) and the amount of time the infusion pump was running (flow time) in Table A1, based on the synthetic SCMG example in Fig. A1. After the data table is constructed, the basic estimation method (Eq. 8), and subsequent calculation of residual volume, is performed automatically using the template Excel spreadsheet provided in the Supplemental Material. The template file, DataExample.xlsx sheet 2 labeled “Excel Calculation,” contains properly formatted data used in Fig. 1 and the implementation of the equations needed to calculate PVR. The user is responsible for ensuring consistent units.
Table A1.
Example formatted SCMG data table
| Flow Rate, ml/s | Voided Volume, ml | Flow Time, s | Ureter Time, s |
|---|---|---|---|
| x1 | v1 | t2-t1 | t3-t0 |
| x2 | v2 | t5-t4 | t5-t3 |
| x3 | v3 | t6-t5 | t6-t5 |
| x4 | v4 | t7-t6 | t8-t6 |
Conceptual example of formatting data from the synthetic four-void serial cystometrogram (SCMG) in Fig. 6.
Fig. A1.
Schematic of a synthetic four-void serial cystometrogram (SCMG) illustrating how data are formatted for the estimation procedure (not real data). The SCMG is initiated when the bladder is completely emptied at t0. Infusion of volume into the bladder begins at t1. The infusion pump is stopped just prior to the first voiding event at time t2, and following the completion of the void the voided volume (v1) is measured at t3. (This is done as an example and, in general, infusion need not be stopped.) Therefore, the total amount of time the ureters spend contributing volume to the bladder for the first void cycle is t3-t0, whereas the total amount of time spent infusing volume into the bladder is only t2-t1 because the pump is not active for the entire duration of the voiding cycle. Note that there are no limitations on the time between emptying the bladder and starting the infusion pump, and experimental preparations can continue long after the initial emptying, if needed. Should the animal void after emptying but before the start of the first infusion trial, treat it as the first void cycle in the SCMG with an infusion rate of zero, and record the voiding time and volume in the data table as normal. The ureter flow time for the second voiding cycle is the span of time between the end of void 1 and void 2, t5-t3. The infusion pump is left running for voiding cycles 2 and 3 of the SCMG, and because the pump is active for the entire duration of the third voiding cycle the ureter and flow times are equal. The residual bladder volume is measured following the final void in the SCMG. The infusion pump is turned off at t7 so that no new volume is infused into the bladder as the residual is being removed for measurement at t8. The infusion flow rate into the bladder is x1, x2, x3, and x4 and the voided volumes are v1, v2, v3, and v4 for void cycles 1 through 4, respectively. Data from this example SCMG are compiled into Table A1. and formatted for use in the estimation procedure software.
The more sophisticated ureter flow estimations described in appendexes 1–3, such as including nonnegativity constraints on PVR, optimal integration of multiple PVR measurements (Eq. 10), or ureter flow estimation without the constant flow assumption (Eq. 12), cannot be performed in Excel. The MATLAB code in the Supplemental Material will import a formatted Excel data table, accept an input indicating which method to use, and perform the computations. The Supplemental Material contains an Excel file formatted for use with the MATLAB code (DataExample.xlsx, sheet 1 labeled “Data”), as well as a script to run these computations and reproduce Fig. 1A (main.m). Documentation for the MATLAB code is provided in the Supplemental Material.
REFERENCES
- 1.Abrams P. Bladder outlet obstruction index, bladder contractility index and bladder voiding efficiency: three simple indices to define bladder voiding function. BJU Int 84: 14–15, 1999. [DOI] [PubMed] [Google Scholar]
- 2.Asimakopoulos AD, De Nunzio C, Kocjancic E, Tubaro A, Rosier PF, Finazzi-Agro E. Measurement of post void residual urine. Neurourol Urodyn 35: 55–57, 2016. [DOI] [PubMed] [Google Scholar]
- 3.Collins CW, Winters JC; American Urological Association; Society of Urodynamics Female Pelvic Medicine and Urogenital Reconstruction. AUA/SUFU adult urodynamics guideline a clinical review. Urol Clin North Am 41: 353–362, 2014. [DOI] [PubMed] [Google Scholar]
- 4.Coolsaet B. Bladder compliance and detrusor activity during the collection phase. Neurourol Urodyn 4: 263–273, 1985. [Google Scholar]
- 5.Gonzalez EJ, Girard BM, Vizzard MA. Expression and function of transforming growth factor-beta isoforms and cognate receptors in the rat urinary bladder following cyclophosphamide-induced cystitis. Am J Physiol Renal Physiol 305: F1265–F1276, 2013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Haga N, Aikawa K, Shishido K, Takahashi N, Yanagida T, Yamaguchi O. Effect of long-term oxybutynin administration on c-fos expression in spinal neurons: inhibition of antimuscarinics on bladder afferents in conscious rats. Urology 73: 200–204, 2009. [DOI] [PubMed] [Google Scholar]
- 7.Kleeman S, Goldwasser S, Vassallo B, Karram M. Predicting postoperative voiding efficiency after operation for incontinence and prolapse. Am J Obstet Gynecol 187: 49–52, 2002. [DOI] [PubMed] [Google Scholar]
- 8.Kuo HC. Will suburothelial injection of small dose of botulinum A toxin have similar therapeutic effects and less adverse events for refractory detrusor overactivity? Urology 68: 993–997, 2006. [DOI] [PubMed] [Google Scholar]
- 9.Lee KS, Na YG, Dean-McKinney T, Klausner AP, Tuttle JB, Steers WD. Alterations in voiding frequency and cystometry in the clomipramine induced model of endogenous depression and reversal with fluoxetine. J Urol 170: 2067–2071, 2003. [DOI] [PubMed] [Google Scholar]
- 10.Lee WC, Chuang YC, Chiang PH, Chien CT, Yu HJ, Wu CC. Pathophysiological studies of overactive bladder and bladder motor dysfunction in a rat model of metabolic syndrome. J Urol 186: 318–325, 2011. [DOI] [PubMed] [Google Scholar]
- 11.Maggi CA, Santicioli P, Meli A. The nonstop transvesical cystometrogram in urethane-anesthetized rats–a simple procedure for quantitative studies on the various phases of urinary-bladder voiding cycle. J Pharmacol Methods 15: 157–167, 1986. [DOI] [PubMed] [Google Scholar]
- 12.OConnor LT, Vaughan ED, Felsen D. In vivo cystometric evaluation of progressive bladder outlet obstruction in rats. J Urol 158: 631–635, 1997. [PubMed] [Google Scholar]
- 13.Osman NI, Chapple CR, Abrams P, Dmochowski R, Haab F, Nitti V, Koelbl H, van Kerrebroeck P, Wein AJ. Detrusor underactivity and the underactive bladder: a new clinical entity? A review of current terminology, definitions, epidemiology, aetiology, and diagnosis. Eur Urol 65: 389–398, 2014. [DOI] [PubMed] [Google Scholar]
- 14.Paick JS, Ku JH, Shin JW, Yang JH, Kim SW. alpha-Blocker monotherapy in the treatment of nocturia in men with lower urinary tract symptoms: a prospective study of response prediction. BJU Int 97: 1017–1023, 2006. [DOI] [PubMed] [Google Scholar]
- 15.Peng CW, Chen JJ, Cheng CL, Grill WM. Improved bladder emptying in urinary retention by electrical stimulation of pudendal afferents. J Neural Eng 5: 144–154, 2008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Peng CW, Chen JJ, Cheng CL, Grill WM. Role of pudendal afferents in voiding efficiency in the rat. Am J Physiol Regul Integr Comp Physiol 294: R660–R672, 2008. [DOI] [PubMed] [Google Scholar]
- 17.Sekido N, Jyoraku A, Okada H, Wakamatsu D, Matsuya H, Nishiyama H. A novel animal model of underactive bladder: analysis of lower urinary tract function in a rat lumbar canal stenosis model. Neurourol Urodyn 31: 1190–1196, 2012. [DOI] [PubMed] [Google Scholar]
- 18.van Mastrigt R, Coolsaet BL, van Duyl WA. Passive properties of the urinary bladder in the collection phase. Med Biol Eng Comput 16: 471–482, 1978. [DOI] [PubMed] [Google Scholar]
- 19.Zhao WX, Aboushwareb T, Turner C, Mathis C, Bennett C, Sonntag WE, Andersson KE, Christ G. Impaired bladder function in aging male rats. J Urol 184: 378–385, 2010. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.



