AIM: To assess the effect of the use of bar code readers and programmable keypads for entry of specimen details and results in two microbiology laboratories. METHODS: The solutions selected in each laboratory are described. The benefits resulting from the implementation were measured in two ways. The speed of data entry and error reduction were measured by observation. A questionnaire was completed by users of bar codes. RESULTS: There were savings in time and in reduced data entry errors. Average time to enter a report by keyboard was 21.1 s v 14.1 s for bar coded results entry. There were no observed errors with the bar code readers but 55 errors with keystroke entries. The laboratory staff of all grades found the system fast, easy to use, and less stressful than conventional keyboard entry. CONCLUSIONS: Indirect time savings should accrue from the observed reduction in incorrectly entered data. Any microbiology laboratory seeking to improve the accuracy and efficiency of data entry into their laboratory information systems should consider the adoption of this technology which can be readily interfaced to existing terminals.

Full text

PDF
54

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Aller R. D., DeWitt C. Cytology result entry without using the keyboard. Acta Cytol. 1994 Sep-Oct;38(5):739–741. [PubMed] [Google Scholar]
  2. Aller R. D., Friedman W. Rapid accurate entry of microbiology results. Arch Pathol Lab Med. 1996 Jan;120(1):57–61. [PubMed] [Google Scholar]
  3. O'Hara S. P., Athersuch R. Speech recognition and direct data entry in clinical microbiology. Br J Biomed Sci. 1996 Sep;53(3):209–213. [PubMed] [Google Scholar]
  4. Smith J. E., Meyer G. E. Organizational approach to implementing bar-code technology in a university hospital. Am J Hosp Pharm. 1987 Mar;44(3):572–573. [PubMed] [Google Scholar]
  5. Tilzer L. L., Jones R. W. Use of bar code labels on collection tubes for specimen management in the clinical laboratory. Arch Pathol Lab Med. 1988 Dec;112(12):1200–1202. [PubMed] [Google Scholar]
  6. Willard K. E., Shanholtzer C. J. User interface reengineering. Innovative applications of bar coding in a clinical microbiology laboratory. Arch Pathol Lab Med. 1995 Aug;119(8):706–712. [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group